What does the literature report about rubber-cup polishing with paste or pumice on implant surfaces?
Key facts — Rubber cups and polishing paste
- Entries in this chapter
- 11 of 819 (2014–2026): clinical study 1 · case report/series 1 · systematic review 2 · review 3 · in vitro 4
- Most cited
- Louropoulou A et al. 2014 (153); Park JB et al. 2015 (58); Cafiero C et al. 2017 (26)
- Products named by the authors
- none named in the abstracts or open-access full texts read
- Manufacturers named by the authors
- EMS (1), Hu-Friedy (1), Komet (1), Straumann (1)
- Chemical agents used alongside
- chlorhexidine (3), citric acid (1), photosensitizer dye (1), saline (1), povidone-iodine (1)
- Often studied together with
- Air-polishing and air-abrasive devices (10), Ultrasonic, sonic and piezoelectric instruments (8), Curettes and hand instruments (7), Chemical and antiseptic agents (4)
What it is
Rotary rubber cups or prophylaxis brushes with a polishing paste or pumice, as used in supportive care and in some laboratory comparisons of instrument effects on titanium surfaces.
Mechanism and use, as the papers describe it
Rubber-cup polishing appears in the entries as one of the mechanical techniques for debridement of implants, listed with scaling, air-powder abrasion and brushing.1 Cafiero et al. describe a rotary rubber cup or brush carrying an abrasive paste, either zirconium-containing or perlite-derived, applied to the smooth collar of tissue-level implants, and Pujarern et al. applied prophy paste with a rubber cup to titanium and other prosthetic materials.2,3 The setting is supportive care rather than surgery: Mariani et al. provided professional implant cleaning with rubber cups at three-monthly recalls after treatment of mucositis, and the reviews place rubber cups among instruments for removing plaque and calculus from the supra- and submucosal part of the implant.4,5,6
Reported operating conditions
The abstracts give the paste rather than speed or pressure: zirconium-containing and perlite-derived pastes with cups or brushes, a commercial prophy paste, and an unspecified abrasive paste.2,3,7 Kister et al. measured the pressure applied during instrumentation online and tested rubber cups alongside silicone polishers on anatase-coated discs.8
Effects on the implant surface reported in laboratory studies
Cafiero et al. measured Ra 0.33 µm and Rz 2.43 µm after a rubber cup with zirconium paste and Ra 0.28 µm and Rz 2.02 µm with perlite paste on implant collars, the highest values among eight procedures, but none increased roughness significantly.2 Pujarern et al., by contrast, found significantly higher roughness on titanium and on lithium disilicate after prophy paste with a rubber cup.3 Kister et al. found that rubber cups left anatase nanocoatings intact while silicone polishers smoothed them and abolished their photocatalytic function.8 Yen Nee et al. summarised that rubber cups left titanium surfaces unchanged or smoother.6 On cleaning, Louropoulou et al. found rubber cups ineffective on contaminated titanium in their systematic review, whereas Chen et al. cite a report of greater biofilm reduction with rubber-cup polishing and abrasive paste than with glycine air abrasion.9,7 Valeriani et al. note that roughness after decontamination changes without a consistent pattern across in vitro studies.10
Position in treatment protocols
Rubber cups are described as a maintenance instrument used at recall visits and as one of the non-metallic options for routine debridement, not as a decontamination step in surgical peri-implantitis protocols.4,5,6 Kister et al. suggest rubber cups with polishing paste, air-flow devices and plastic-tipped instruments for nanocoated surfaces.8
Limitations and open questions as stated by the authors
Louropoulou et al. note that the laboratory studies were too heterogeneous for quantitative analysis and that their clinical impact requires clarification, Pujarern et al. and Curylofo-Zotti et al. call for further studies, and Valeriani et al. suggest clinical trials to link surface alterations to outcomes.9,3,5,10
Sources cited in this description (10)
- Park JB et al. (2015). Effects of titanium brush on machined and sand-blasted/acid-etched titanium disc using confocal microscopy and contact profilometry. Clin Oral Implants Res. doi:10.1111/clr.12302 · in vitro
- Cafiero C et al. (2017). Implant surface roughness alterations induced by different prophylactic procedures: an in vitro study. Clin Oral Implants Res. doi:10.1111/clr.12849 · in vitro
- Pujarern P et al. (2026). Surface Roughness Assessment of Implant Prosthetic Components Treated by Dental Ultrasonic and Polishing Instruments. Eur J Dent. doi:10.1055/s-0046-1818622 · in vitro
- Giulia Maria Mariani et al. (2020). One-year clinical outcomes following non-surgical treatment of peri-implant mucositis with adjunctive diode laser application Minerva Dental and Oral Science. doi:10.23736/s0026-4970.20.04340-x · clinical study
- Fabiana Almeida Curylofo‐Zotti et al. (2014). instrumentation of dental implants: a literature review RSBO. doi:10.21726/rsbo.v10i1.900 · review
- Yen Nee W et al. (2022). Effects on the Titanium Implant Surface by Different Hygiene Instrumentations: A Narrative Review. Cureus. doi:10.7759/cureus.30884 · review
- Chen A et al. (2023). A Review of Bacterial Colonization on Dental Implants With Various Hygiene Instruments. Cureus. doi:10.7759/cureus.47483 · review
- Kister F et al. (2017). Peri-implantitis cleaning instrumentation influences the integrity of photoactive nanocoatings. Dent Mater. doi:10.1016/j.dental.2016.10.002 · in vitro
- Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. Clin Oral Implants Res. doi:10.1111/clr.12224 · systematic review
- Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. Clin Oral Implants Res. doi:10.1111/clr.70077 · systematic review
The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.
What the randomised clinical trials concluded
No randomised trial in the index names this method.
What the systematic reviews and meta-analyses concluded
2 systematic reviews or meta-analyses mention this method; most cover several methods at once (the synthesis chapter lists all of them).
The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.
— Valeriani L et al. 2026, Clin Oral Implants Res; cited 3.The available data suggest that the air abrasive may remove plaque effectively from machined, SLA and TPS titanium surfaces. Positive results were also observed for rotating titanium brushes on SLA surfaces and ultrasonic scalers with non-metal tip on polished and SLA surfaces. However, the clinical impact of these findings requires further clarification.
— Louropoulou A et al. 2014, Clin Oral Implants Res; cited 153.
Guideline and consensus mentions
Neither of the two consensus reports in the index names this method in its abstract.
Clinical studies and case reports
1 non-randomised clinical study and 1 case report or series.
Based on the present results, the adjunct use of diode laser showed little but not statistically significant additional benefits in the treatment of peri-implant mucositis after an observation period of one year.
— Giulia Maria Mariani et al. 2020, Minerva Dental and Oral Science; cited 24.
Laboratory and animal findings
4 in vitro / ex vivo and 0 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.
From this study, air polishing devices should be used with caution with titanium, PEEK, and zirconia; Prophy paste should be used with caution with titanium and lithium disilicate; and P5 scaler should be used with caution with zirconia. Further studies are required to study the clinical outcomes.
— Pujarern P et al. 2026, Eur J Dent; cited 1.All tested procedures did not increase implant surface roughness significantly. Treatment with an air-powder abrasive system at high-pressure setting resulted in a smoothening of the implant collar surface.
— Cafiero C et al. 2017, Clin Oral Implants Res; cited 26.The integrity of functional nanocoatings depends on the applied instrumentation. Air flow device, rubber cup with polishing paste and plastic tipped instruments prevent damage on these nanosurfaces and may be preferably used when decontaminating anatase and other nanocoatings in a clinical setting.
— Kister F et al. 2017, Dent Mater; cited 13.This study showed that the treatment with the titanium brush did not significantly change the roughness parameters, including Sa and Sz, in both MA and SA surfaces. Correlations between confocal microscopy and surface profilometry showed high correlation with a Pearson correlation coefficient of 0.98.
— Park JB et al. 2015, Clin Oral Implants Res; cited 58.
Parameters as stated in the abstracts
The abstracts in this chapter state no numeric operating parameter (speed, power, time, pressure, concentration); such details are in the papers' Methods sections.
One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.
Products and manufacturers named
Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.
Manufacturers: EMS (1), Hu-Friedy (1), Komet (1), Straumann (1).
Availability of named products, as far as public company information shows
Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.
- TiBrush (Straumann) — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.
Chemical agents used alongside
Agents named in the same papers (5 different): chlorhexidine (3), citric acid (1), photosensitizer dye (1), saline (1), povidone-iodine (1). Chapter 13 collects the chemical literature.
Limitations of this chapter
- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the how this reader is made page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.
Entries in this chapter (11)
Related chapters
- 4. Air-polishing and air-abrasive devices
- 8. Ultrasonic, sonic and piezoelectric instruments
- 9. Curettes and hand instruments
- 13. Chemical and antiseptic agents
- 14. Synthesis — what the systematic reviews and consensus reports conclude
- 17. All entries — the searchable table
This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to chapter 15. Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).