# Implant Surface Decontamination in Peri-implantitis: an evidence-based reader

HANS KOREA CO.,Ltd. — https://www.nitibrush.com/articles/literature-index/ — Reader Rev. 0 · 2026-11-28 — 819 entries, updated 2026-11-28. This file holds every chapter of the reader as text (the tables of entries are on the web pages and in the JSON/CSV data). Each quotation is the paper's own conclusion from its abstract, unchanged; the DOI link leads to the publisher's page. Not a ranking.


---

# 3. Titanium and nickel-titanium brushes

Chapter 3 of an evidence-based reader on implant surface decontamination in peri-implantitis: 127 entries on titanium and nickel-titanium brushes — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/titanium-brush/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about titanium brushes and NiTi brushes on the implant surface?

**Key facts — Titanium and nickel-titanium brushes**

- Entries in this chapter: 127 of 819 (2012–2026): RCT 16 · clinical study 17 · case report/series 17 · systematic review 9 · consensus 1 · review 5 · in vitro 48 · animal study 4 · not classified 10
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Rokaya D et al. 2020](https://doi.org/10.1055/s-0040-1715779) (293); [Louropoulou A et al. 2014](https://doi.org/10.1111/clr.12224) (153)
- Products named by the authors: TiBrush (8), i-Brush (6), Air-Flow (5), Perio-Flow (4), Ti-Brush (4), NiTiBrush (1), Labrida BioClean (1), BioClean (1), NiTi Brush (1), R-Brush (1)
- Manufacturers named by the authors: Straumann (7), EMS (7), Dentium (3), Biolase (3), Zimmer Biomet (3), Hu-Friedy (3), Neobiotech (2), Nobel Biocare (2), Dentsply (2), Sirona (2)
- Chemical agents used alongside: saline (23), hydrogen peroxide (19), chlorhexidine (19), tetracycline (11), citric acid (9), antibiotics (systemic) (7), amoxicillin (4), sodium hypochlorite (3)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (46), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (39), [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) (33), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (32)
- Entries naming the NiTi Brush: 36 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Rotary brushes with metal bristles — commercially pure titanium or a nickel-titanium alloy — mounted in a low-speed handpiece and run over the exposed threads of the implant to remove biofilm, calculus and granulation-tissue remnants, in most reports during surgical access with saline irrigation. The papers write "titanium brush", "Ti-brush", "rotary titanium brush", "rotating titanium brush", "NiTi brush" or a product name; this reader keeps each author's wording and does not merge the instruments of different manufacturers into one.


### Mechanism and use, as the papers describe it

Park et al. describe the instrument as a rotating brush with titanium bristles, introduced for debridement of the implant surface when peri-implant osseous defects occur.[1] The publications in this chapter write "rotating titanium brush", "round titanium brush" or "tufted brush with titanium bristles", and "rotating nickel-titanium brush", "Ni-Ti brush" or "Ti-Ni alloy brush" where the bristles are a nickel-titanium alloy.[2,3,4,5,6,7] Where a product is named, the abstracts give TiBrush, Ti-Brush, i-Brush, R-Brush, PeriBrush, NiTiBrush Nano or NiTi Brush; most clinical abstracts name none.[8,9,10,11,12,13]

In the clinical entries the brush is applied during surgical access, after flap elevation and removal of granulation tissue, to the exposed implant surface, usually before a reconstructive or resective step.[14,15,16,17,18] Wohlfahrt et al. introduced it in 2012 for a narrow, deep defect in which access for other instruments was described as difficult, and later case reports describe its use at retrograde lesions and at implant surfaces exposed in the maxillary sinus.[19,20,21] A smaller group of entries places the brush in non-surgical or supportive settings: Parashis et al. combined ultrasonic tips and rotating titanium brushes in a non-surgical protocol, Sbricoli et al. tested it in a model of closed instrumentation, and Sirinirund et al. examined it among supportive-therapy instruments.[22,23,24]


### Reported operating conditions

Few abstracts state a speed; Park et al. ran the brush at 300 rpm under irrigation for 40 s in total.[1] Laboratory application times range from 30 s per specimen, through 60 s and 90 s, to 2 min, and two studies simulated repeated maintenance with 20 strokes (40 s) and 100 strokes (200 s).[25,26,11,27,28,24,29] Clinically, Park et al. recorded a mean decontamination time of 3 min 1 s with brushes against 5 min 27 s for implantoplasty.[13] Chemical agents used with the brush include 3% hydrogen peroxide, 0.05% or 0.2% chlorhexidine, 40% citric acid, 5.25% sodium hypochlorite, 0.2% chlorhexidine with 1% sodium hypochlorite, and tetracycline or doxycycline slurries in saline; other entries combined it with photodynamic therapy, a diode laser or electrolytic cleaning.[16,10,30,31,32,33,34,35,36,37,38]


### Effects on the implant surface reported in laboratory studies

Reports on roughness diverge.[39] Park et al., John et al., Toma et al., Lollobrigida et al. and Charbel Anka et al. saw scratch lines or altered morphology under SEM but no significant change in roughness parameters, whereas Cha et al. reported that round and tufted titanium brushes flattened the thread profile of SLA implants, Alabbad et al. reported scratches, flattening and loose titanium particles after three of four rotary brushes, Bayrak et al. and Khalilzadeh et al. reported smoother surfaces, and Hu et al. and Lang et al. reported increased roughness.[1,2,8,40,41,3,11,31,42,43,29] Ravidà et al. placed titanium brushes among instruments that induced significant surface alterations and peak flattening, while Louropoulou et al. reported positive cleaning results for rotating titanium brushes on SLA surfaces.[44,45] Kotsakis et al. observed reduced corrosion resistance and increased titanium dissolution over 30 days after brushing, and Kao et al. measured a mean released particle size of 1.05 µm for the brush, with brush wear as an additional source.[25,46]

The laboratory models in this chapter that measured residual contamination after brushing report it: Ichioka et al. found the brush and air-polishing removed more biofilm than gauze without complete removal, Luengo et al. found the brush most effective where intraosseous walls were present, Sanz-Martín et al. found thread geometry governed access, and Khalilzadeh et al. and Meto et al. reported smaller bacterial reductions than their comparators.[47,48,49,42,27] Cell studies are mixed: Brunello et al. recorded the highest SaOS-2 viability on discs treated with a NiTi brush and stored in saline, Toma et al. and Sousa et al. found osteoblast markers or biocompatibility maintained after TiBrush treatment, whereas Jazaeri et al., Kotsakis et al. and Furtsev et al. reported reduced fibroblast viability, reduced osteoconductivity or loss of stem-cell attachment on brushed surfaces.[12,50,33,51,25,7]


### Position in treatment protocols

In some randomised trials the brush is the sole mechanical decontamination step: Park et al. compared rotating titanium brushes with implantoplasty and reported non-inferiority at 12 months, Toma et al. compared a titanium brush with plastic curettes and an air-abrasive device, and Regidor et al. used a rotating titanium brush alone in the control arm and reported no added benefit from adjunctive electrolytic cleaning.[13,15,38] Baima et al. concluded that titanium brushes and implantoplasty showed favourable results as single decontamination methods, while no method showed clear evidence of superiority over others.[52]

More often the brush is one element of a combined protocol: de Tapia et al. added it to hydrogen peroxide and plastic ultrasonic tips in regenerative surgery and reported a larger pocket-depth reduction at 12 months, with no significant difference at 5 years; Jepsen et al. used brushes and hydrogen peroxide before grafting; Schwarz et al. used it with implantoplasty and augmentation; Monje et al. combined it with the electrolytic method.[14,53,16,17,54] Systematic reviews describe this adjunctive role: Ramanauskaite et al. found one trial in which the brush reduced bleeding more than air polishing or control instrumentation and one in which it added nothing to implantoplasty with mechanical and chemical cleaning, Pappolla Sessa et al. found favourable results in surgical protocols without inter-group superiority, and the IADR consensus noted a positive effect on radiographic defect level when hydrogen peroxide but not rotary titanium brushes was the adjunct.[55,56,57] In dog studies, Almohandes et al. and Viganò et al. found no difference between brushing and saline or gauze controls.[58,59]


### Limitations and open questions as stated by the authors

Review authors note that conclusions rest on few trials and that larger randomised trials with longer follow-up are needed.[60,56,55,53] Laboratory authors caution that ink removal is not equivalent to biofilm decontamination, that surface changes and titanium release after brushing need evaluation, and that the clinical impact of in vitro results requires clarification.[26,9,25,39,45]


### Sources cited in this description (60)

1. Park JB et al. (2015). Effects of titanium brush on machined and sand-blasted/acid-etched titanium disc using confocal microscopy and contact profilometry. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12302 · in vitro
2. John G et al. (2014). Rotating titanium brush for plaque removal from rough titanium surfaces--an in vitro study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12147 · in vitro
3. Cha JK et al. (2019). The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13446 · in vitro
4. Lee J et al. (2022). A Case Report of a 2-Year Follow-Up of Minimally Invasive Surgery in Peri-Implantitis: Peri-Implant Excisional Procedure and Access Surgery. *J Oral Implantol*. https://doi.org/10.1563/aaid-joi-D-20-00344 · case report/series
5. Ichioka Y et al. (2022). Mechanical removal of biofilm on titanium discs: An in vitro study. *J Biomed Mater Res B Appl Biomater*. https://doi.org/10.1002/jbm.b.34978 · in vitro
6. Conserva E et al. (2019). Evaluation of Biological Response of STRO-1/c-Kit Enriched Human Dental Pulp Stem Cells to Titanium Surfaces Treated with Two Different Cleaning Systems. *Int J Mol Sci*. https://doi.org/10.3390/ijms20081868 · not classified
7. Furtsev TV et al. (2023). Laser Cleaning Improves Stem Cell Adhesion on the Dental Implant Surface during Peri-Implantitis Treatment. *Dent J (Basel)*. https://doi.org/10.3390/dj11020030 · not classified
8. Toma S et al. (2018). In Vitro Comparison of the Efficacy of Peri-Implantitis Treatments on the Removal and Recolonization of Streptococcus gordonii Biofilm on Titanium Disks. *Materials (Basel)*. https://doi.org/10.3390/ma11122484 · in vitro
9. Assunção MA et al. (2023). Dental Implant Surface Decontamination and Surface Change of an Electrolytic Method versus Mechanical Approaches: A Pilot In Vitro Study. *J Clin Med*. https://doi.org/10.3390/jcm12041703 · in vitro
10. Alotaibi M et al. (2019). The effect of a decontamination protocol on contaminated titanium dental implant surfaces with different surface topography in edentulous patients. *Acta Odontol Scand*. https://doi.org/10.1080/00016357.2018.1504986 · clinical study
11. Alabbad M et al. (2025). Effect of mechanical instrumentation on titanium implant surface properties. *Dent Mater*. https://doi.org/10.1016/j.dental.2024.12.014 · in vitro
12. Brunello G et al. (2025). The Effect of NiTi Brush, Polishing Brush, and Chemical Agent on the Dental Implant Surface Morphology and Cytocompatibility. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.13417 · in vitro
13. Park SH et al. (2026). Implantoplasty vs. Rotating Titanium Brushes in the Surgical Treatment of Peri-Implantitis: A 1-Year Randomised Controlled Clinical Trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.70056 · RCT
14. de Tapia B et al. (2019). The adjunctive effect of a titanium brush in implant surface decontamination at peri-implantitis surgical regenerative interventions: A randomized controlled clinical trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13095 · RCT
15. Toma S et al. (2019). Clinical Evaluation of Three Surgical Modalities in the Treatment of Peri-Implantitis: A Randomized Controlled Clinical Trial. *J Clin Med*. https://doi.org/10.3390/jcm8070966 · RCT
16. Jepsen K et al. (2016). Reconstruction of Peri-implant Osseous Defects: A Multicenter Randomized Trial. *J Dent Res*. https://doi.org/10.1177/0022034515610056 · RCT
17. Schwarz F et al. (2023). Effectiveness of modified and control protocols for the surgical therapy of combined peri-implantitis-related defects. A retrospective analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14057 · clinical study
18. An YZ et al. (2017). Surgical Treatment of Severe Peri-Implantitis Using a Round Titanium Brush for Implant Surface Decontamination: A Case Report With Clinical Reentry. *J Oral Implantol*. https://doi.org/10.1563/aaid-joi-D-16-00163 · case report/series
19. Johan Caspar Wohlfahrt et al. (2012). Mechanical Debridement of a Peri‐Implant Osseous Defect With a Novel Titanium Brush and Reconstruction With Porous Titanium Granules: A Case Report With Reentry Surgery *Clinical Advances in Periodontics*. https://doi.org/10.1902/cap.2012.110062 · case report/series
20. Dae‐Young Kang (2025). Reconstructive Approach for Treatment of Retrograde Peri-implantitis in Mandibular Canine Region: A Case Report *Journal of implantology and applied sciences*. https://doi.org/10.32542/implantology.2025010 · case report/series
21. Park WB et al. (2025). Intrasinus Decontamination for Maxillary Sinus Infection Related to the Apically Exposed Implant in the Sinus: A Report of Two Cases. *J Oral Implantol*. https://doi.org/10.1563/aaid-joi-D-24-00224 · case report/series
22. Parashis AO et al. (2026). Long Term Outcomes of Non-Surgical Treatment of Peri-Implantitis: A Retrospective Case Series. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11688 · case report/series
23. Sbricoli L et al. (2025). Comparison of Non-Surgical Methods for Implant Surface Treatment in Simulated Bone Resorption Patterns: An In Vitro Study. *J Clin Med*. https://doi.org/10.3390/jcm14207244 · in vitro
24. Sirinirund B et al. (2019). Effects of Mechanical Instrumentation with Commercially Available Instruments Used in Supportive Peri-implant Therapy: An In Vitro Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.7409 · in vitro
25. Kotsakis GA et al. (2021). Effect of implant cleaning on titanium particle dissolution and cytocompatibility. *J Periodontol*. https://doi.org/10.1002/JPER.20-0186 · in vitro
26. Nicastro A et al. (2026). Comparison of Glycine Air Polishing and a Rotary Titanium Brush for the Removal of a Surrogate Surface Marker from Implants in Class Ib and IIIb Peri-Implant Defects: An In Vitro Study. *J Clin Med*. https://doi.org/10.3390/jcm15228771 · in vitro
27. Aida Meto et al. (2019). Differential Efficacy of Two Dental Implant Decontamination Techniques in Reducing Microbial Biofilm and Re-Growth onto Titanium Disks In Vitro *Applied Sciences*. https://doi.org/10.3390/app9153191 · in vitro
28. Ince Kuka G et al. (2025). Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces. *J Vis Exp*. https://doi.org/10.3791/69521 · in vitro
29. Lang MS et al. (2016). Cell Attachment Following Instrumentation with Titanium and Plastic Instruments, Diode Laser, and Titanium Brush on Titanium, Titanium-Zirconium, and Zirconia Surfaces. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.4440 · in vitro
30. Radu Bolun et al. (2024). Mechanical modification of the implant surface as an adjunctive measure during surgical treatment of peri-implantitis *Journal of Stomatological Medicine*. https://doi.org/10.53530/1857-1328.24.1.09 · clinical study
31. Bayrak M et al. (2022). Influence of Clinical Decontamination Techniques on the Surface Characteristics of SLA Titanium Implant. *Nanomaterials (Basel)*. https://doi.org/10.3390/nano12244481 · in vitro
32. Lollobrigida M et al. (2022). Efficacy of Combined Mechanical and Chemical Decontamination Treatments on Smooth and Rough Titanium Surfaces and Their Effects on Osteoconduction: An Ex Vivo Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.9105 · in vitro
33. Sousa V et al. (2022). The Effect of Microcosm Biofilm Decontamination on Surface Topography, Chemistry, and Biocompatibility Dynamics of Implant Titanium Surfaces. *Int J Mol Sci*. https://doi.org/10.3390/ijms231710033 · in vitro
34. Neely AL et al. (2020). Successful Management of Peri-Implantitis Using a Titanium Brush and a Doxycycline-Saline Slurry for Surface Detoxification With Guided Bone Regeneration: A 5-Year Follow-Up. *Clin Adv Periodontics*. https://doi.org/10.1002/cap.10085 · case report/series
35. Badarudhin BBK et al. (2026). Three-year follow-up of a peri-implantitis case managed by titanium brush and tetracycline slurry for surface decontamination with guided bone regeneration. *J Indian Soc Periodontol*. https://doi.org/10.4103/jisp.jisp_395_24 · case report/series
36. Pier Paolo Poli et al. (2016). Peri-Implant Mucositis and Peri-Implantitis: A Current Understanding of Their Diagnosis, Clinical Implications, and a Report of Treatment Using a Combined Therapy Approach *Journal of Oral Implantology*. https://doi.org/10.1563/aaid-joi-d-16-00082 · not classified
37. Karimi MR et al. (2021). Efficacy of titanium brush, 915 nm diode laser, citric acid for eradication of Staphylococcus aureus from implant surfaces. *BMC Oral Health*. https://doi.org/10.1186/s12903-021-01997-z · in vitro
38. Regidor E et al. (2026). Adjunctive Electrolytic Implant Surface Decontamination in the Reconstructive Surgical Treatment of Peri-Implantitis-A Randomized Clinical Trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70152 · RCT
39. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
40. Lollobrigida M et al. (2020). The Prevention of Implant Surface Alterations in the Treatment of Peri-Implantitis: Comparison of Three Different Mechanical and Physical Treatments. *Int J Environ Res Public Health*. https://doi.org/10.3390/ijerph17082624 · in vitro
41. Charbel Anka et al. (2025). In vitro evaluation of implant surface alteration following different decontamination methods *Discover Medicine*. https://doi.org/10.1007/s44337-025-00477-5 · in vitro
42. Khalilzadeh S et al. (2025). Laboratory Investigation of the Effect of Three Decontamination Methods on Surface Alterations of Dental Implants : *Galen Med J*. https://doi.org/10.31661/gmj.vi.3864 · in vitro
43. Hu J et al. (2020). The impact of surface alteration on epithelial tissue attachment after the mechanical cleaning of titanium or zirconia surface. *J Oral Rehabil*. https://doi.org/10.1111/joor.12920 · in vitro
44. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
45. Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12224 · systematic review
46. Kao A et al. (2024). Quantity and Size of Titanium Particles Released from Different Mechanical Decontamination Procedures on Titanium Discs: An In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj12050123 · in vitro
47. Ichioka Y et al. (2023). Decontamination of biofilm-contaminated implant surfaces: An in vitro evaluation. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14136 · in vitro
48. Luengo F et al. (2022). In vitro effect of different implant decontamination methods in three intraosseous defect configurations. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13991 · in vitro
49. Sanz-Martín I et al. (2021). Significance of implant design on the efficacy of different peri-implantitis decontamination protocols. *Clin Oral Investig*. https://doi.org/10.1007/s00784-020-03681-y · in vitro
50. Toma S et al. (2016). In vitro evaluation of peri-implantitis treatment modalities on Saos-2osteoblasts. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12686 · in vitro
51. Jazaeri MS et al. (2026). Biofilm removal capacity and titanium surface integrity in non-abrasive versus abrasive peri-implantitis cleaning interventions. *J Periodontol*. https://doi.org/10.1002/jper.11371 · in vitro
52. Baima G et al. (2022). Surface decontamination protocols for surgical treatment of peri-implantitis: A systematic review with meta-analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13992 · systematic review
53. de Tapia B et al. (2025). Peri-implantitis reconstructive treatment implementing a titanium brush: 5-year extension results from a randomized clinical trial. *J Periodontol*. https://doi.org/10.1002/JPER.24-0673 · RCT
54. Monje A et al. (2025). Recombinant human platelet-derived growth factor-BB-mediated reconstructive therapy of advanced peri-implantitis bone defects: A case series. *Int J Oral Implantol (Berl)*. https://pubmed.ncbi.nlm.nih.gov/40047362/ · case report/series
55. Ramanauskaite A et al. (2023). Photo/mechanical and physical implant surface decontamination approaches in conjunction with surgical peri-implantitis treatment: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13783 · systematic review
56. Pappolla Sessa C et al. (2025). Mucositis and Peri-Implant Disease Treatment with Chitosan and Titanium Brushes: A Systematic Review. *J Clin Med*. https://doi.org/10.3390/jcm14238306 · systematic review
57. Ganesan SM et al. (2026). Biomaterials for resolution of peri-implantitis: Consensus report of Workgroup 2 of the IADR Implantology Research Group Best Evidence Consensus Symposium on Peri-Implant Disease and Its Treatment. *J Periodontol*. https://doi.org/10.1002/JPER.24-0432 · consensus
58. Almohandes A et al. (2022). Surgical treatment of experimental peri-implantitis using mechanical and chemical decontamination procedures: A pre-clinical in vivo study. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13607 · animal study
59. Viganò P et al. (2019). Use of TiBrush for surface decontamination at peri-implantitis sites in dogs: Radiographic and histological outcomes. *J Investig Clin Dent*. https://doi.org/10.1111/jicd.12378 · animal study
60. González FJ et al. (2021). Adjuvant Effect of Titanium Brushes in Peri-Implant Surgical Treatment: A Systematic Review. *Dent J (Basel)*. https://doi.org/10.3390/dj9080084 · systematic review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## "Titanium brush" — a generic term; "NiTi Brush" — one manufacturer's instrument

In this literature **"titanium brush"** is a generic term. It covers every rotary brush with titanium or titanium-alloy bristles, from several manufacturers, and the papers also write "Ti-brush", "rotary titanium brush" or "rotating titanium brush" for the same class. **"NiTi Brush"** is the name of one specific instrument — HANS Korea's brush with nickel-titanium bristles, introduced in 2010, the first of the class — and when a paper writes it, or writes "HANS Korea", the instrument is identified.

The two usages overlap in a way a reader has to know: **many papers write "titanium brush" in the title, abstract and text and identify the instrument as HANS Korea's NiTi Brush only in brackets, in a footnote or in the Methods section**. Read from the abstract alone, such a paper looks like a study of an anonymous titanium brush; read in full, it is a study of the NiTi Brush. On the [Published studies](https://www.nitibrush.com/articles/) page, ${FIG.titaniumBrushNamed} of the ${FIG.publications} publications that identify the NiTi Brush (${FIG.titaniumBrushNamedClinical} of the ${FIG.clinical} clinical studies) are of this kind, with the instrument quotation shown for each.

How this reader handles the names, entry by entry:

- **36 entries name the NiTi Brush or HANS Korea** — in the abstract, in the open-access full text, or in the text or footnote of the paper as verified on the Published studies page. They are listed below with the place where the name appears, and again in [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/).
- **21 entries name another product or manufacturer** (TiBrush (7), EMS (6), Straumann (6), i-Brush (5), Air-Flow (5), Ti-Brush (4), Biolase (3), Zimmer Biomet (3), Perio-Flow (3), Hu-Friedy (3), Nobel Biocare (2), Dentium (2)). The name is shown exactly as written, and results obtained with that instrument are not transferred to the NiTi Brush or to any other brush.
- **70 entries write "titanium brush" and name no product or manufacturer anywhere this reader could read**. They are listed as titanium-brush studies without attribution; some of them may concern the NiTi Brush, some another brush, and the reader does not guess. They are not counted among the NiTi Brush entries.
- Where an abstract says "titanium brush" and the full text says "NiTi Brush (HANS Korea)", the entry carries both: the generic term in the title and the specific name marked "(full text)".


### Entries of this chapter that identify the NiTi Brush (36)

- [Regidor E et al. 2026](https://doi.org/10.1111/clr.70152), Clin Oral Implants Res (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Jazaeri MS et al. 2026](https://doi.org/10.1002/jper.11371), J Periodontol (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Monje A et al. 2026](https://doi.org/10.1111/cid.70144), Clin Implant Dent Relat Res (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Parma-Benfenati S et al. 2026](https://doi.org/10.1002/cap.10359), Clin Adv Periodontics (case report/series) — named in: text or footnote of the paper, verified on the Published studies page.
- [Soliman OH et al. 2026](https://doi.org/10.23805/JO.2026.764), J Osseointegr (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Zhou W et al. 2026](https://doi.org/10.1111/jcpe.70115), J Clin Periodontol (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Alabbad M et al. 2025](https://doi.org/10.1016/j.dental.2024.12.014), Dent Mater (in vitro) — named in: abstract (NiTiBrush).
- [Brunello G et al. 2025](https://doi.org/10.1111/cid.13417), Clin Implant Dent Relat Res (in vitro) — named in: abstract (NiTi Brush).
- [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med (systematic review) — named in: text or footnote of the paper, verified on the Published studies page.
- [Alibegovic L et al. 2025](https://doi.org/10.1111/clr.14393), Clin Oral Implants Res (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Dionigi C et al. 2025](https://doi.org/10.1038/s43856-025-00756-3), Commun Med (Lond) (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683), J Periodontol (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Monje A et al. 2025](https://doi.org/10.1111/cid.70075), Clin Implant Dent Relat Res (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Monje A et al. 2025](https://doi.org/10.11607/prd.7151), Int J Periodontics Restorative Dent (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Tagliaferri N et al. 2024](https://doi.org/10.3390/nano14050392), Nanomaterials (Basel) (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Kao A et al. 2024](https://doi.org/10.3390/dj12050123), Dent J (Basel) (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Walaa Babgi et al. 2024](https://doi.org/10.54940/ms75920247), Journal of Umm Al-Qura University for Medical Sciences (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Kotsakis GA et al. 2024](https://doi.org/10.1038/s41529-024-00514-1), Npj Mater Degrad (not classified) — named in: text or footnote of the paper, verified on the Published studies page.
- [Panes C et al. 2024](https://doi.org/10.3390/bioengineering11040397), Bioengineering (Basel) (animal study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Ichioka Y et al. 2023](https://doi.org/10.1111/clr.14136), Clin Oral Implants Res (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Schwarz F et al. 2023](https://doi.org/10.1111/clr.14057), Clin Oral Implants Res (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Liu X et al. 2023](https://doi.org/10.3390/ijms241411431), Int J Mol Sci (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Arthur Brincat et al. 2023](https://doi.org/10.3390/app13127224), Applied Sciences (case report/series) — named in: text or footnote of the paper, verified on the Published studies page.
- [Monje A et al. 2023](https://doi.org/10.1002/JPER.22-0511), J Periodontol (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Monje A et al. 2023](https://doi.org/10.1111/cid.13244), Clin Implant Dent Relat Res (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Regidor E et al. 2023](https://doi.org/10.1111/jcpe.13796), J Clin Periodontol (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Regidor E et al. 2023](https://www.nitibrush.com/articles/), Perio Clín (review) — named in: text or footnote of the paper, verified on the Published studies page.
- [Ichioka Y et al. 2022](https://doi.org/10.1002/jbm.b.34978), J Biomed Mater Res B Appl Biomater (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Derks J et al. 2022](https://doi.org/10.1111/clr.13972), Clin Oral Implants Res (RCT) — named in: text or footnote of the paper, verified on the Published studies page.
- [Monje A et al. 2022](https://doi.org/10.1002/JPER.21-0103), J Periodontol (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Galarraga-Vinueza ME et al. 2020](https://doi.org/10.1111/jcpe.13335), J Clin Periodontol (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Hiroyasu K 2018](https://ir.tdc.ac.jp/irucaa/bitstream/10130/4541/1/10_33.pdf), J Jpn Soc Oral Exam (not classified) — named in: text or footnote of the paper, verified on the Published studies page.
- [Seul‐Kee Kim et al. 2016](https://doi.org/10.21851/obr.40.1.201603.9), Oral Biology Research (in vitro) — named in: text or footnote of the paper, verified on the Published studies page.
- [Kusek ER 2015](https://doi.org/10.4172/2161-1122.1000348), Dentistry (clinical study) — named in: text or footnote of the paper, verified on the Published studies page.
- [Narendrakumar K 2015](https://etheses.bham.ac.uk/id/eprint/5677/), PhD thesis, University of Birmingham (not classified) — named in: text or footnote of the paper, verified on the Published studies page.
- [Suzuki A et al. 2014](https://doi.org/10.11237/jsoi.27.370), J Jpn Soc Oral Implantol (not classified) — named in: text or footnote of the paper, verified on the Published studies page.


### How the 36 publications that identify the NiTi Brush word the instrument

The [Published studies](https://www.nitibrush.com/articles/) page quotes, for each of its publications, the sentence in which the paper names the instrument. Read together, the quotations show the naming practice this chapter describes. Grouped by wording (the quotation is the paper's, shortened where long):


### (a) Write "titanium brush" (or "titanium NiTibrush") and identify HANS Korea / NiTi Brush in the same sentence, bracket or footnote — 15

- [Derks J et al. 2022](https://doi.org/10.1111/clr.13972), Clin Oral Implants Res — “a rotating titanium brush (Nano NiTi Brush, HANS KOREA CO. Ltd) used at ≤1200 rpm under continuous irrigation”
- [Alibegovic L et al. 2025](https://doi.org/10.1111/clr.14393), Clin Oral Implants Res — “a rotating titanium brush (Nano NiTi Brush, HANS KOREA CO. Ltd) under irrigation with saline”
- [Regidor E et al. 2023](https://doi.org/10.1111/jcpe.13796), J Clin Periodontol — “a rotating titanium brush (Nano NiTi Brush, HANS KOREA CO. Ltd, Goyang, South Korea) at ≤1200 rpm under continuous irrigation with saline”
- [Regidor E et al. 2026](https://doi.org/10.1111/clr.70152), Clin Oral Implants Res · 37 — “a rotating titanium brush (Nano NiTi Brush, Hans Korea, Goyang, South Korea) was used at ≤ 1200 rpm under continuous irrigation with saline”
- [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683), J Periodontol · 96(10):1126-1137 — “the exposed threads of the implants were brushed with a titanium brush (NiTi Brush Pocket, HANS KOREA Co. Ltd., Goyang, South Korea)”
- [Soliman OH et al. 2026](https://doi.org/10.23805/JO.2026.764), J Osseointegr · 18(3):102-107 — “mechanical debridement of the implant surface with titanium brushes (NiTi-brush, Hans Korea Co Ltd) under copious sterile saline irrigation", in both groups.”
- [Schwarz F et al. 2023](https://doi.org/10.1111/clr.14057), Clin Oral Implants Res — “a titanium brush (Hans Korea Co.,Ltd., Gyeonggi-do, Korea)”
- [Brincat A et al. 2023](https://doi.org/10.3390/app13127224), Appl Sci · 13(12):7224 — “Mechanical decontamination was completed using titanium NiTibrushes (ICT Micro and ICT Nano, Hans Korea® Gyeonggi-do, South Korea)”
- [Galarraga-Vinueza ME et al. 2020](https://doi.org/10.1111/jcpe.13335), J Clin Periodontol — “a titanium brush (Hans Korea Co., Ltd.)”
- [Babgi W et al. 2024](https://doi.org/10.54940/ms75920247), Umm Al-Qura University, Makkah, Saudi Arabia — “a titanium brush attached to a low-speed handpiece (HANS Korea Co., Ltd., NiTi Brush Omega, Korea)”
- [Zhou W et al. 2026](https://doi.org/10.1111/jcpe.70115), J Clin Periodontol · 53(5):658-680 — “After removal of granulation tissues with a curette, implant surfaces were decontaminated using a titanium brush (Hans Korea Co. Ltd.)”
- [Parma-Benfenati S et al. 2026](https://doi.org/10.1002/cap.10359), Clin Adv Periodontics · 16(3):477-484 — “final mechanical debridement was performed with a titanium brush (NiTi Brush, HANS Korea Co., Ltd.)”
- [Dionigi C et al. 2025](https://doi.org/10.1038/s43856-025-00756-3), Commun Med — “implant surfaces at peri-implantitis sites decontaminated with titanium curettes and "a rotating titanium brush (Nano NiTi Brush, HANS KOREA CO. Ltd)”
- [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med · 14:8306 — “Figure 1 shows a titanium brush (POCKET® model, Hans Korea, Seoul, Republic of Korea).”
- [Regidor E et al. 2023](https://www.nitibrush.com/articles/), Perio Clín · (27):21-38 — “Figure 1, implant surface decontamination methods: "Titanium brushes ICT Nano® & Micro® (Hans Korea)". I.C.T. (Implant Cleaning Technique) is the former name of the NiTi Brush.”


### (b) Write チタンブラシ ("titanium brush" in Japanese) and identify HANS Korea — 2

- [Suzuki A et al. 2014](https://doi.org/10.11237/jsoi.27.370), J Jpn Soc Oral Implantol · 27(3):370-376 — “「0.09 mm ニッケルチタンワイヤーのチタンブラシ（I.C.T., Hans Korea 社製）」 — a titanium brush of 0.09 mm nickel-titanium wire (I.C.T., made by Hans Korea), used at 3,000 rpm without irrigation (translation by HANS Korea). I.C.T. (Implant …”
- [Hiroyasu K 2018](https://www.nitibrush.com/articles/), J Jpn Soc Oral Exam · 10(1):33–38 (review, in Japanese) — “Text: 「骨外へ露出したラフサーフェイス部分をチタンブラシ等で研磨し、スムースサーフェイスへと改質し…（図８）」 — the rough surface exposed outside the bone is polished with a titanium brush or similar and converted to a smooth surface (Figure 8) (translation); Figure 8, …”


### (c) Write "titanium brush" or "titanium fibers" and name Salvin Dental Specialties, the US distributor of the HANS Korea-made RotoBrush — 4

- [Panes C et al. 2024](https://doi.org/10.3390/bioengineering11040397), Bioengineering · 11(4):397 — “the biofilm-contaminated cap was decontaminated by mechanical brushing treatment with titanium fibers (RotoBrush-Titanium, SALVIN, Charlotte, NC, USA)". Salvin Dental Specialties (Charlotte, NC) is HANS Korea's …”
- [Kotsakis GA et al. 2024](https://doi.org/10.1038/s41529-024-00514-1), npj Mater Degrad · 8:98 — “abrasive titanium brush (Ti-brush)" applied for 30 s at 300 rpm with a surgical implant motor; "the information of titanium brush used: Salvin RotoBrush-Titanium® Thread Cleaning Brush For Wide Area-Short". Salvin …”
- [Jazaeri MS et al. 2026](https://doi.org/10.1002/jper.11371), J Periodontol · 97(3):498-510 — “titanium brush" (abstract); "Brush treatment was evaluated using a NiTi brush powered by a surgical motor and applied for 15 s at each side of the disk at a speed of 1200 rpm", footnote "RotoBrush-Titanium Thread …”
- [Kusek ER 2015](https://doi.org/10.4172/2161-1122.1000348), Dentistry · 5(12):1000348 — “The surface of the implant is cleaned with titanium brush (Salvin Dental Specialities Inc. Charlotte, NC)". Salvin Dental Specialties (Charlotte, NC) is HANS Korea's distributor in the United States; its RotoBrush …”


### (d) Write "NiTi brush" or "nickel-titanium brush" with HANS Korea, without the generic term — 15

- [Monje A et al. 2023](https://doi.org/10.1002/JPER.22-0511), J Periodontol — “NiTi brushes (Hans Korea Co., Gyeonggi-do, Korea) for about 2–3 min at 600 rpm.”
- [Monje A et al. 2025](https://doi.org/10.1111/cid.70075), Clin Implant Dent Relat Res · 27(4) — “NiTi brushes (Hans Korea Co., Gyeonggi-do, Korea) at 600 rpm for approximately 2–3 min”
- [Monje A et al. 2024](https://doi.org/10.11607/prd.7151), Int J Periodontics Restorative Dent — “NiTi brushes (Hans Korea Co., Gyeonggi-do, Korea) for about 2–3 minutes at 600 rpm.”
- [Monje A et al. 2026](https://doi.org/10.1111/cid.70144), Clin Implant Dent Relat Res · 28 — “NiTi brushes (Hans Korea Co., Gyeonggi-do, Korea) at 600 rpm for approximately 2–3 min", in both groups.”
- [Monje A et al. 2025](https://www.nitibrush.com/articles/), Int J Oral Implantol · 18(1):47–57 — “NiTi brushes (Hans Korea, Gyenonggi-do, South Korea) for approximately 2 to 3 minutes at 600 rpm”
- [Monje A et al. 2021](https://doi.org/10.1002/JPER.21-0103), J Periodontol — “NiTi brushes (Hans Korea Co., Gyeonggi-do, Korea).”
- [Monje A et al. 2023](https://doi.org/10.1111/cid.13244), Clin Implant Dent Relat Res — “NiTi brushes (Hans Korea Co., Gyeonggi-do, Korea).”
- [Brunello G et al. 2025](https://doi.org/10.1111/cid.13417), Clin Implant Dent Relat Res · 27:e13417 — “NiTi Brush (NANO, HANS KOREA).”
- [Kao A et al. 2024](https://doi.org/10.3390/dj12050123), Dent J · 12(5):123 — “NiTi Brush Omega, Hans Korea, Gyeonggi-do, Republic of Korea”
- [Ichioka Y et al. 2022](https://doi.org/10.1002/jbm.b.34978), J Biomed Mater Res B Appl Biomater · 110(5):1044-1055 — “a rotating nickel-titanium brush (NiTi brush, Nano model, HANS Korea, South Korea) was used at a rotation speed of 1200 rpm under irrigation with saline”
- [Ichioka Y et al. 2023](https://doi.org/10.1111/clr.14136), Clin Oral Implants Res · 34(10):1058-1072 — “The rotating nickel-TiB (NiTi brush, HANS Korea) was used at a rotational speed of 1200 rpm under constant irrigation with saline”
- [Kim SK et al. 2016](https://doi.org/10.21851/obr.40.1.201603.9), Oral Biol Res · 40(1):9-15 — “ICB (I.C.T.®, HANS, Seoul, Korea) treatment … used until the RBM or SLA surface was removed with the rotatory instrument at 800 rpm". I.C.T. (Implant Cleaning Technique) is the former name of the NiTi Brush.”
- [Liu X et al. 2023](https://doi.org/10.3390/ijms241411431), Int J Mol Sci · 24(14):11431 — “mechanically debrided using two different NiTi brushes in a sequence (NiTi brush, Nano and Pocket, HANS Korea, Seoul, Republic of Korea). The debridement was performed at a speed of 800 rpm for 40 s with each brush …”
- [Tagliaferri N et al. 2024](https://doi.org/10.3390/nano14050392), Nanomaterials · 14(5):392 — “nickel–titanium brushes (I.C.T. Brush micro, Hans Korea Co. Ltd., Gyeonggi-do, Korea/De Ore, Verona, Italy) … used at 400 rpm and 600 rpm, respectively, for two sequential rounds of 45 s each". I.C.T. (Implant Cleaning …”
- [Narendrakumar K 2015](https://www.nitibrush.com/articles/), PhD thesis, University of Birmingham · Appendix I, pp. 227-228 — “The NiTi brush is intended to remove biological materials from the implant surface (Hans Korea, Korea).”

The counts are read from the quotations on the Published studies page at each build. Groups (a), (b) and (c) together — 21 of the 36 publications — are the publications that write the generic term, in English or Japanese, and identify the HANS Korea instrument; this is the figure the website states as "21 of the 36 publications (12 of the 19 clinical studies)". Publications outside the 34 that write "titanium brush" and name the maker are added to the list only after the full text has been verified.


## Published clinical evidence by named brush, as the papers report it

For each rotary brush that the papers of this index name, the table counts the entries that identify it (by product or manufacturer name in the abstract or open-access full text, or by the full text as read for the reading notes) and lists the studies in patients. The reading notes give, for each product, the patients, implants, follow-up and the role the brush played in the protocol, each with its source. Nothing here ranks the products: in most trials the brush is a step common to all arms, and no entry of this index compares brushes of different manufacturers with each other. A trial in which two products were used appears in both rows, each with the role that product played.

| Product (as named) · manufacturer | Entries naming it, by study type | Studies in patients |
|---|---|---|
| **NiTi Brush** — HANS Korea, Republic of Korea (also sold as Salvin RotoBrush-Titanium in the United States; former name I.C.T., supplied in Italy by De Ore) | 36: RCT 9 · clinical study 9 · case report/series 2 · systematic review 1 · review 1 · in vitro 9 · animal study 1 · not classified 4 | 20 (listed below with the role of the brush) |
| **i-Brush / R-Brush** — NeoBiotech, Republic of Korea | 9: RCT 3 · clinical study 1 · in vitro 5 | 4 (listed below with the role of the brush) |
| **TN Brush** — Dentium, Republic of Korea | 1: RCT 1 | 1 (listed below with the role of the brush) |
| **Titanium Brush Set** — MegaGen, Republic of Korea | 1: in vitro 1 | none in this index |
| **TiBrush / Ti-Brush** — Straumann, Switzerland (see the availability note above) | 12: RCT 3 · case report/series 1 · in vitro 6 · animal study 2 | 4 (listed below with the role of the brush) |
| **PeriBrush** — Tigran Technologies AB, Sweden (see the availability note above) | 1: clinical study 1 | 1 (listed below with the role of the brush) |


### Studies in patients and the role of the brush, product by product

For each study in patients, what the brush was in the design: common to all arms (the trial compared something else), a randomised arm (the brush itself was compared), used in one arm only, additionally used in some implants, one protocol applied to all patients, or a follow-up of an earlier trial. Only a randomised arm tests the brush; in every other role the figures belong to the whole protocol.


### NiTi Brush: 20 studies in patients

- [Regidor E et al. 2026](https://doi.org/10.1111/clr.70152) (RCT) — control arm: the brush alone was the control, compared with the brush plus electrolytic cleaning
- [Monje A et al. 2026](https://doi.org/10.1111/cid.70144) (RCT) — common to both groups; the trial compared the extent of implantoplasty
- [Parma-Benfenati S et al. 2026](https://doi.org/10.1002/cap.10359) (case report/series) — single case, one protocol
- [Soliman OH et al. 2026](https://doi.org/10.23805/JO.2026.764) (clinical study) — common to both groups; the trial compared two reconstructive materials
- [Zhou W et al. 2026](https://doi.org/10.1111/jcpe.70115) (clinical study) — used in all four surgical protocols of the retrospective cohort
- [Alibegovic L et al. 2025](https://doi.org/10.1111/clr.14393) (RCT) — common to both arms (3-year follow-up of the Derks 2022 trial)
- [Dionigi C et al. 2025](https://doi.org/10.1038/s43856-025-00756-3) (clinical study) — used at the treated sites; a tissue study, not a treatment comparison
- [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683) (RCT) — used in the flap-surgery arm only; the trial compared flap surgery with diode-laser therapy
- [Monje A et al. 2025](https://doi.org/10.1111/cid.70075) (RCT) — common to both arms; the trial compared electrolytic cleaning with hydrogen peroxide after brushing
- [Monje A et al. 2025](https://doi.org/10.11607/prd.7151) (clinical study) — common to both arms (single-centre analysis of the same trial)
- [Walaa Babgi et al. 2024](https://doi.org/10.54940/ms75920247) (clinical study) — case report, one protocol
- [Schwarz F et al. 2023](https://doi.org/10.1111/clr.14057) (clinical study) — used in all protocols of the retrospective cohort
- [Arthur Brincat et al. 2023](https://doi.org/10.3390/app13127224) (case report/series) — case series, one protocol
- [Monje A et al. 2023](https://doi.org/10.1002/JPER.22-0511) (RCT) — common to both arms; the trial compared a barrier membrane with none
- [Monje A et al. 2023](https://doi.org/10.1111/cid.13244) (RCT) — common to both arms (secondary analysis of the same trial)
- [Regidor E et al. 2023](https://doi.org/10.1111/jcpe.13796) (RCT) — common to both arms; the trial compared a resorbable membrane with none
- [Derks J et al. 2022](https://doi.org/10.1111/clr.13972) (RCT) — common to both arms; the trial compared a bone substitute with none
- [Monje A et al. 2022](https://doi.org/10.1002/JPER.21-0103) (clinical study) — one protocol (implantoplasty with brushing) in all patients
- [Galarraga-Vinueza ME et al. 2020](https://doi.org/10.1111/jcpe.13335) (clinical study) — one protocol in all patients (pilot)
- [Kusek ER 2015](https://doi.org/10.4172/2161-1122.1000348) (clinical study) — clinical technique report, one protocol


### i-Brush / R-Brush: 4 studies in patients

- [Park SH et al. 2026](https://doi.org/10.1111/jcpe.70056) (RCT) — additionally used in some implants of the brush arm after removal of a screw-retained prosthesis (R-Brush); the basic instrument of that arm was the Dentium TN Brush, and the implants with the R-Brush are not counted separately
- [Hwang S et al. 2023](https://doi.org/10.1186/s12903-023-02981-5) (clinical study) — part of the protocol in all patients of the retrospective cohort (i-Brush, identified in the full text)
- [Rakašević D et al. 2023](https://doi.org/10.3390/jfb14030149) (RCT) — common to both arms (R-Brush); the trial compared a bone substitute with and without hyaluronic acid
- [Toma S et al. 2019](https://doi.org/10.3390/jcm8070966) (RCT) — named in the paper; the brush arm of this trial used the Ti-Brush


### TN Brush: 1 study in patients

- [Park SH et al. 2026](https://doi.org/10.1111/jcpe.70056) (RCT) — randomised test arm: the TN Brush was the basic instrument of the brush arm (versus implantoplasty, non-inferiority design); in implants whose screw-retained prosthesis was removed, the NeoBiotech R-Brush was additionally used, so the arm is not the TN Brush alone


### TiBrush / Ti-Brush: 4 studies in patients

- [de Tapia B et al. 2025](https://doi.org/10.1002/JPER.24-0673) (RCT) — 5-year follow-up of the same trial (17 patients)
- [Sgarbanti C et al. 2023](https://doi.org/10.1155/2023/6624249) (case report/series) — single case, one protocol
- [de Tapia B et al. 2019](https://doi.org/10.1111/jcpe.13095) (RCT) — randomised test arm: brush added to hydrogen peroxide and ultrasonic decontamination, versus the same without the brush
- [Toma S et al. 2019](https://doi.org/10.3390/jcm8070966) (RCT) — randomised arm: brush versus plastic curettes versus air-abrasive device


### PeriBrush: 1 study in patients

- [Alotaibi M et al. 2019](https://doi.org/10.1080/00016357.2018.1504986) (clinical study) — one protocol applied to all implant pieces worn by six patients


### Reading notes by product


### NiTi Brush — HANS Korea, Republic of Korea (also sold as Salvin RotoBrush-Titanium in the United States; former name I.C.T., supplied in Italy by De Ore)

The entries that identify this instrument are the 36 publications of the Published studies page, listed there with the sentence in which each paper names it; 19 are studies in patients.[1,2]

The largest trial is a multicentre randomised trial of reconstructive surgery in 138 patients with 147 implants in six centres, 12 months, in which a rotating titanium brush was the mechanical decontamination step in both arms; the same cohort was reported again at 3 years.[1,3]

A retrospective cohort of 223 patients with 406 implants treated with four surgical protocols between 2018 and 2023, mean follow-up about 30.8 months, used the brush in all protocols.[2]

In most trials the brush is a step common to all arms, so the trials compare other measures (bone substitutes, membranes, implantoplasty extent, adjunctive electrolytic or chemical decontamination); in one trial the brush alone was the control arm against brush plus electrolytic cleaning, and one case report follows a treated implant for 10 years.[4,5,6,7]

The two most recent laboratory entries, performed with the Salvin-labelled brush, report surface oxide damage and lower fibroblast viability after abrasive brushing compared with non-contact methods.[8,9]


### i-Brush / R-Brush — NeoBiotech, Republic of Korea

A retrospective survival analysis of 89 patients with 227 implants treated for peri-implantitis reports the outcome by initial bone loss; the protocol included curettes, laser, antimicrobials and a titanium brush, and the review of the full text identifies the brush as the i-Brush, so the paper documents clinical use rather than an effect of the brush alone.[10]

A randomised pilot trial of reconstructive therapy in 13 patients with 19 implants, 6 months, compared a bovine bone substitute with or without hyaluronic acid; the R-Brush was used in both arms, so the trial does not compare brushes.[11]

In the 30-patient randomised trial of the TN Brush, the R-Brush was additionally used in some implants after removal of a screw-retained prosthesis, without a separate count for those implants.[12]

Laboratory entries compare the R-Brush and i-Brush with an electrolytic method and an erythritol jet on inoculated implants, and the i-Brush with three other rotary brushes on SLA discs.[13,14]


### TN Brush — Dentium, Republic of Korea

A single-centre randomised trial with a non-inferiority design enrolled 30 patients with 30 implants, 12 months, comparing surface decontamination with rotating titanium brushes against implantoplasty; the review of the full text identifies the brush as the TN Brush.[12]

At 12 months the composite outcome was reached in 6 of 15 implants in the brush group and 4 of 15 in the implantoplasty group; probing depth decreased by 3.6 ± 1.5 mm and 3.3 ± 1.2 mm respectively, and the authors concluded non-inferiority of the brush procedure.[12]


### Titanium Brush Set — MegaGen, Republic of Korea

The entry that names this manufacturer is a laboratory study of hygiene instrumentation on 20 implant fixtures in four groups, the brush group comprising five fixtures, assessing surface change; it reports no patients or follow-up.[15]

No entry of this index reports a clinical study in patients in which this product is identified; the absence of a retrieved study is not evidence that none exists.[15]


### TiBrush / Ti-Brush — Straumann, Switzerland

A randomised double-blind trial of regenerative surgery in 30 patients, 15 per group, 12 months, added a titanium brush to decontamination with 3% hydrogen peroxide and plastic ultrasonic tips; the brush group showed a larger reduction of probing depth at the deepest site, and the same cohort was re-examined at 5 years with 17 patients available.[16,17]

A randomised parallel-group trial in 47 patients compared plastic curettes (15 patients, 25 implants), an air-abrasive device (16 patients, 22 implants) and the Ti-Brush (16 patients, 23 implants) over 6 months, and reported a greater reduction of gingival index and probing depth in the brush group.[18]

A case report describes the treatment of an implant periapical lesion with the TiBrush and guided bone regeneration, and laboratory entries compare the brush with an air-abrasive device and ultrasonic tips on biofilm removal and osteoblast response.[19,20,21]


### PeriBrush — Tigran Technologies AB, Sweden

The entry that names this product attached 24 implant pieces of two surface types to the dentures of six patients for 30 days and then applied a decontamination protocol of PeriBrush and 3% hydrogen peroxide; complete decontamination was achieved on 5 of the 24 pieces.[22]


### Sources cited in this section (22)

1. Derks J et al. (2022). Reconstructive surgical therapy of peri-implantitis: A multicenter randomized controlled clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13972 · RCT
2. Zhou W et al. (2026). Treatment Outcome of Surgical Protocols for Peri-Implantitis: A Retrospective Cohort Study in a Specialised University Centre. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.70115 · clinical study
3. Alibegovic L et al. (2025). Bone Substitute Material in the Surgical Therapy of Peri-Implantitis-3-Year Outcomes of a Randomized Controlled Trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14393 · RCT
4. Monje A et al. (2025). Surface Decontamination on the Reconstructive Therapy of Peri-Implantitis: A Multicenter Randomized Clinical Trial. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.70075 · RCT
5. Monje A et al. (2026). Extent of Implantoplasty in the Combined Surgical Therapy of Peri-Implantitis: A Quasi-Randomized Clinical Trial. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.70144 · RCT
6. Regidor E et al. (2026). Adjunctive Electrolytic Implant Surface Decontamination in the Reconstructive Surgical Treatment of Peri-Implantitis-A Randomized Clinical Trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70152 · RCT
7. Parma-Benfenati S et al. (2026). Bone stability after regenerative peri-implantitis treatment: A 10-year follow-up case study. *Clin Adv Periodontics*. https://doi.org/10.1002/cap.10359 · case report/series
8. Kotsakis GA et al. (2024). Dynamic assessment of titanium surface oxides following mechanical damage reveals only partial passivation under inflammatory conditions. *Npj Mater Degrad*. https://doi.org/10.1038/s41529-024-00514-1 · not classified
9. Jazaeri MS et al. (2026). Biofilm removal capacity and titanium surface integrity in non-abrasive versus abrasive peri-implantitis cleaning interventions. *J Periodontol*. https://doi.org/10.1002/jper.11371 · in vitro
10. Hwang S et al. (2023). Survival analysis of implants after surgical treatment of peri-implantitis based on bone loss severity and surgical technique: a retrospective study. *BMC Oral Health*. https://doi.org/10.1186/s12903-023-02981-5 · clinical study
11. Rakašević D et al. (2023). Reconstructive Peri-Implantitis Therapy by Using Bovine Bone Substitute with or without Hyaluronic Acid: A Randomized Clinical Controlled Pilot Study. *J Funct Biomater*. https://doi.org/10.3390/jfb14030149 · RCT
12. Park SH et al. (2026). Implantoplasty vs. Rotating Titanium Brushes in the Surgical Treatment of Peri-Implantitis: A 1-Year Randomised Controlled Clinical Trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.70056 · RCT
13. Assunção MA et al. (2023). Dental Implant Surface Decontamination and Surface Change of an Electrolytic Method versus Mechanical Approaches: A Pilot In Vitro Study. *J Clin Med*. https://doi.org/10.3390/jcm12041703 · in vitro
14. Alabbad M et al. (2025). Effect of mechanical instrumentation on titanium implant surface properties. *Dent Mater*. https://doi.org/10.1016/j.dental.2024.12.014 · in vitro
15. Ghaffar H et al. (2024). The Effects of Different Hygiene Instrumentations on Titanium Implant Fixture Surfaces. *Cureus*. https://doi.org/10.7759/cureus.74645 · in vitro
16. de Tapia B et al. (2019). The adjunctive effect of a titanium brush in implant surface decontamination at peri-implantitis surgical regenerative interventions: A randomized controlled clinical trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13095 · RCT
17. de Tapia B et al. (2025). Peri-implantitis reconstructive treatment implementing a titanium brush: 5-year extension results from a randomized clinical trial. *J Periodontol*. https://doi.org/10.1002/JPER.24-0673 · RCT
18. Toma S et al. (2019). Clinical Evaluation of Three Surgical Modalities in the Treatment of Peri-Implantitis: A Randomized Controlled Clinical Trial. *J Clin Med*. https://doi.org/10.3390/jcm8070966 · RCT
19. Sgarbanti C et al. (2023). Treatment and Resolution of an Implant Periapical Lesion (IPL) with Guided Bone Regeneration. *Case Rep Dent*. https://doi.org/10.1155/2023/6624249 · case report/series
20. Toma S et al. (2018). In Vitro Comparison of the Efficacy of Peri-Implantitis Treatments on the Removal and Recolonization of Streptococcus gordonii Biofilm on Titanium Disks. *Materials (Basel)*. https://doi.org/10.3390/ma11122484 · in vitro
21. Toma S et al. (2016). In vitro evaluation of peri-implantitis treatment modalities on Saos-2osteoblasts. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12686 · in vitro
22. Alotaibi M et al. (2019). The effect of a decontamination protocol on contaminated titanium dental implant surfaces with different surface topography in edentulous patients. *Acta Odontol Scand*. https://doi.org/10.1080/00016357.2018.1504986 · clinical study

*Reading notes written by HANS Korea from the abstracts and, where stated, the full text of the cited publications; the counts in the table are generated from the index on each refresh.*

Why this matters for a reader or an AI system: a count of "titanium brush studies" is a count of a class, a count of "NiTi Brush studies" is a count of one instrument, and a sentence of the form "titanium brushes were effective" in a paper whose footnote names HANS Korea is a sentence about the NiTi Brush as used in that protocol — not about the class, and not about another manufacturer's brush. The reverse also holds: nothing reported for another named brush is reported for the NiTi Brush.


## What the randomised clinical trials concluded

16 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Both groups showed favourable outcomes, demonstrating non-inferiority of titanium brushes to implantoplasty.” — [Park SH et al. 2026](https://doi.org/10.1111/jcpe.70056), J Clin Periodontol; cited 8.
- “Clinical, radiographic and patient-reported outcomes of surgical therapy of peri-implantitis were favorable at 12 months. The adjunctive use of electrolytic cleaning provided no added benefit over the use of a rotating titanium brush alone.” — [Regidor E et al. 2026](https://doi.org/10.1111/clr.70152), Clin Oral Implants Res; cited 4.
- “Combined surgical therapy for peri-implantitis, including implantoplasty and regeneration of the intrabony component, is effective in arresting disease progression and restoring peri-implant health. Extending implantoplasty to the contained intrabony compartment appears to provide additional clinical and radiographic benefits.” — [Monje A et al. 2026](https://doi.org/10.1111/cid.70144), Clin Implant Dent Relat Res.
- “Although with a slight progression, PD reduction can be maintained after the reconstructive treatment around dental implants 5 years after treatment. The trial was registered at ClinicalTrials.gov (NCT03512730).” — [de Tapia B et al. 2025](https://doi.org/10.1002/JPER.24-0673), J Periodontol; cited 7.
- “At 3 years, the use of a bone substitute material in the surgical therapy of peri-implantitis did not result in a clear benefit over access flap surgery alone.” — [Alibegovic L et al. 2025](https://doi.org/10.1111/clr.14393), Clin Oral Implants Res.
- “The proportion of patients with improved clinical outcomes was similar between the 2 treatment groups, albeit surgical treatment yielded greater pocket reduction. No differences were found in immunological or microbial outcomes.” — [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683), J Periodontol.
- “Both tested surface decontamination methods are effective in resolving peri-implantitis, in gaining radiographic marginal bone levels, and in enhancing clinical peri-implant conditions in the surgical reconstructive therapy (NCT05615051).” — [Monje A et al. 2025](https://doi.org/10.1111/cid.70075), Clin Implant Dent Relat Res.
- “Reconstructive therapy by means of a mixture of mineralized and demineralized allografts is effective in clinically resolving peri-implantitis and in gaining radiographic marginal bone level. The addition of a barrier membrane to reconstructive therapy of peri-implantitis does not seem to enhance the outcomes of contained bone defects (NCT05282667).” — [Monje A et al. 2023](https://doi.org/10.1002/JPER.22-0511), J Periodontol.
- “Baseline DA of peri-implantitis intrabony components predicts radiographic bone gain in reconstructive therapy (NCT05282667-this clinical trial was not registered prior to participant recruitment and randomization).” — [Monje A et al. 2023](https://doi.org/10.1111/cid.13244), Clin Implant Dent Relat Res.
- “Short-term outcomes suggested that BBS merged with HA could improve clinical and radiographic outcomes in peri-implantitis reconstructive therapy.” — [Rakašević D et al. 2023](https://doi.org/10.3390/jfb14030149), J Funct Biomater.

6 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

9 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.
- “Several mechanical/physical instrumentation procedures including curettes, ultrasonics, lasers, rotating brushes and air-polishing are documented; however, a beneficial effect over oral hygiene instructions alone or superiority over other procedures could not be demonstrated. Moreover, it remains unclear whether combinations of different procedures or their repetition over time may provide additional benefits.” — [Verket A et al. 2023](https://doi.org/10.1111/jcpe.13789), J Clin Periodontol; cited 62.
- “Owing to the limited available data, clinical efficacy of photo/mechanical and physical implant surface decontamination in conjunction with surgical peri-implantitis therapy is inconclusive. However, titanium brushes may be beneficial in reducing signs of inflammation.” — [Ramanauskaite A et al. 2023](https://doi.org/10.1111/jcpe.13783), J Clin Periodontol; cited 44.
- “The standardized mean difference with a 95% confidence interval of the studied parameters was estimated using the random effect model; however, statistical differences were not detected between air polishing and comparative modalities in the treatment of peri-implantitis.” — [Bi J et al. 2023](https://doi.org/10.1563/aaid-joi-D-23-00114), J Oral Implantol; cited 7.
- “No single decontamination method demonstrated clear evidence of superiority compared to the others. Systemic antibiotics, but not Er:Yag laser, may provide short-term clinical benefits in terms of treatment success (CRD42020182303).” — [Baima G et al. 2022](https://doi.org/10.1111/clr.13992), Clin Oral Implants Res; cited 122.
- “titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.” — [González FJ et al. 2021](https://doi.org/10.3390/dj9080084), Dent J (Basel); cited 18.

1 further systematic review entry of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

- “Current evidence suggests that incorporating reconstructive biomaterials into surgical treatment may not definitively enhance the likelihood of peri-implantitis disease resolution. However, this lack of effect may be due to other factors such as implant surface treatments which may also affect clinical outcomes.” — [Ganesan SM et al. 2026](https://doi.org/10.1002/JPER.24-0432), J Periodontol; cited 4.


### The German S3 guideline (AWMF 083-023, version 2.0, December 2022)

The German clinical practice guideline on the treatment of peri-implant infections, issued by the German Society of Implantology (DGI) and the German Society of Dental, Oral and Craniomandibular Sciences (DGZMK) at the S3 level, version 2.0 of 2 December 2022 and valid until December 2027, is not indexed in PubMed and is therefore not an entry of this index; it is cited here from its published long version.[1]

Recommendation 18 (new in 2022), for non-reconstructive surgical therapy, reads: "Alternative Verfahren zur Implantatoberflächendekontamination sollten bei der nicht-rekonstruktiven chirurgischen Therapie der Periimplantitis zum Einsatz kommen. Evidenz liegt vor für die Verwendung einer Titanbürste sowie Glycinpulver basierten Air-Polishings" — alternative procedures for implant-surface decontamination should be used in non-reconstructive surgical therapy; evidence exists for the use of a titanium brush and of glycine-powder air-polishing (translation); grade B, strong consensus (35/0/0), level of evidence Ia.[1]

The background text for that recommendation reports, from a 6-month randomised trial, a greater reduction of bleeding on probing and probing depth with a titanium brush or glycine air-polishing than with plastic curettes, a significant improvement of the marginal bone level with the brush, and treatment success by the composite criteria in a minority of implants in every group (plastic curettes 22%, air-polishing 33%, titanium brush 33%).[1,2]

Recommendation 20 (new in 2022), for combined surgical therapy, reads: "Auf den adjuvanten Einsatz einer Titanbürste oder den alternativen Einsatz eines Er:YAG Lasers zur Implantatoberflächendekontamination kann bei der kombinierten chirurgischen Therapie der Periimplantitis verzichtet werden" — the adjuvant use of a titanium brush, or the alternative use of an Er:YAG laser, for implant-surface decontamination can be dispensed with in combined surgical therapy (translation); grade 0, strong consensus (29/0/0), level of evidence Ib, on the basis of a randomised trial in which adding a titanium brush to ultrasonic and hydrogen-peroxide decontamination gave a significantly larger probing-depth reduction but a comparable reduction of bleeding at one year.[1,3]

Recommendation 19, for reconstructive surgical therapy, concerns ozone therapy and the carbon-dioxide laser and does not mention brushes; in non-surgical therapy of peri-implant mucositis the guideline reports no additional effect of a chitosan brush over conventional biofilm removal.[1,4]

The guideline names no product and no manufacturer. The two randomised trials it cites for the titanium brush were performed with the Straumann TiBrush (Ti-Brush); according to public company information checked on 28 November 2026, the Straumann Switzerland online shop presents the Labrida BioClean brush as replacing that product, an end of sale in every country not being confirmed (see the availability note above).[2,3,1]

The guideline does not cite the studies in which the NiTi Brush is identified; the studies in patients of the titanium brushes that the papers name, including those currently offered, are listed product by product in the section above.[1]


### Sources cited for the guideline (4)

1. DGI, DGZMK et al. (2022). Die Behandlung periimplantärer Infektionen an Zahnimplantaten — S3-Leitlinie, Langfassung, Version 2.0 (2 December 2022, valid until December 2027) *AWMF-Registernummer 083-023*. https://register.awmf.org/de/leitlinien/detail/083-023 · consensus
2. Toma S et al. (2019). Clinical Evaluation of Three Surgical Modalities in the Treatment of Peri-Implantitis: A Randomized Controlled Clinical Trial. *J Clin Med*. https://doi.org/10.3390/jcm8070966 · RCT
3. de Tapia B et al. (2019). The adjunctive effect of a titanium brush in implant surface decontamination at peri-implantitis surgical regenerative interventions: A randomized controlled clinical trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13095 · RCT
4. Wohlfahrt JC et al. (2019). Treatment of peri-implant mucositis with a chitosan brush-A pilot randomized clinical trial. *Int J Dent Hyg*. https://doi.org/10.1111/idh.12381 · RCT


## Clinical studies and case reports

17 non-randomised clinical studies and 17 case reports or series.

- “Three months after surgery, ISQ values increased to 84, and radiographic evaluation demonstrated absence of the periapical lesion, allowing for successful restoration and long-term stability at one- and two-year follow-ups.” — [Ahmed Ameen Al-Obaidi 2026](https://doi.org/10.1563/aaid-joi-d-26-00143), Journal of Oral Implantology; cited 0.
- “(no abstract)” — [Soliman OH et al. 2026](https://doi.org/10.23805/JO.2026.764), J Osseointegr.
- “Surgical peri-implantitis outcome was associated with systemic antibiotic, surgeon, molar site, overdenture, baseline suppuration and PD.” — [Zhou W et al. 2026](https://doi.org/10.1111/jcpe.70115), J Clin Periodontol.
- “The present results indicate that titanium micro-particles are commonly found in tissues surrounding dental implants and are not associated with the occurrence of peri-implantitis.” — [Dionigi C et al. 2025](https://doi.org/10.1038/s43856-025-00756-3), Commun Med (Lond).
- “EM combined with mechanical instrumentation results in a safe and effective surface decontamination modality in the reconstructive therapy of peri-implantitis. This strategy resulted in a disease resolution rate of ~91%.” — [Monje A et al. 2025](https://doi.org/10.11607/prd.7151), Int J Periodontics Restorative Dent.
- “Implantoplasty is more suitable for lateral areas. Implant surface polishing is indicated at implant sites where no bone regeneration is expected.” — [Radu Bolun et al. 2024](https://doi.org/10.53530/1857-1328.24.1.09), Journal of Stomatological Medicine; cited 0.

11 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

48 in vitro / ex vivo and 4 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “Non-abrasive waterjet cleaning is a superior method for the clinical treatment of peri-implantitis biofilms versus mechanical abrasive cleaning while maintaining titanium implant surface properties necessary for reintegration with peri-implant tissue.” — [Jazaeri MS et al. 2026](https://doi.org/10.1002/jper.11371), J Periodontol; cited 2.
- “Er:YAG best preserved SLA microtopography but exhibited a lower debridement efficacy (3.27 ± 0.83) than mechanical methods. No method resulted in a pristine surface.” — [Yurdakul B et al. 2026](https://doi.org/10.3390/nano16120703), Nanomaterials (Basel); cited 1.
- “In this surrogate-marker model, the relative performance of the two instruments depended on defect morphology. The interaction rests on the combination of a higher value for air polishing and a lower, more variable one for the brush in class IIIb defects, and it is not robust to the omission of the three lowest brush values.” — [Nicastro A et al. 2026](https://doi.org/10.3390/jcm15228771), J Clin Med; cited 0.
- “Contact angle measurements indicated enhanced wettability in IB, PIB, and NiTiB groups (p < 0.05), while the LB group exhibited values comparable to the control (p > 0.05). Mechanical decontamination of implant surfaces utilising rotary brushes can alter implant surface properties.” — [Alabbad M et al. 2025](https://doi.org/10.1016/j.dental.2024.12.014), Dent Mater; cited 6.
- “None of the investigated protocols compromised the cytocompatibility of the titanium dental implant surface. The best results were registered in the NITI group when the samples were stored in saline. Future studies should confirm the effectiveness of the proposed methods in removing bacterial biofilm from contaminated implant surfaces.” — [Brunello G et al. 2025](https://doi.org/10.1111/cid.13417), Clin Implant Dent Relat Res; cited 4.
- “Maintaining surface roughness while eliminating biofilms is crucial for the successful regeneration of implants with peri-implantitis. These three techniques have been shown to preserve surface roughness, making them viable options for use without any concerns.” — [Charbel Anka et al. 2025](https://doi.org/10.1007/s44337-025-00477-5), Discover Medicine; cited 2.

42 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “No significant differences were observed in the different bone neoformation parameters between the groups that did not receive bone grafts (p > 0.05). In this experimental model, the presence of peri-implantitis microcosms was not a determining factor in the bone volume parameter, both in the groups that received regenerative treatment and in those that did not.” — [Panes C et al. 2024](https://doi.org/10.3390/bioengineering11040397), Bioengineering (Basel).
- “It is concluded that decontamination procedures including citric acid gel or rotating titanium brush did not improve outcomes following surgical treatment of experimental peri-implantitis. Results were, however, influenced by the implant surface characteristics.” — [Almohandes A et al. 2022](https://doi.org/10.1111/jcpe.13607), J Clin Periodontol; cited 13.
- “Mechanical implant surface decontamination performed with a rotatory titanium brush resulted in a marginal bone level gain, yielding a low content of inflammatory infiltrate close to the marginal bone.” — [Viganò P et al. 2019](https://doi.org/10.1111/jicd.12378), J Investig Clin Dent; cited 18.
- “Resolution of peri-implantitis after access surgery and decontamination of peri-implant surfaces with TiBrush(™) with or without sodium hypochlorite is possible. However, the concomitant use of sodium hypochlorite has minor effect on treatment outcomes.” — [Carral C et al. 2016](https://doi.org/10.1111/jcpe.12566), J Clin Periodontol; cited 42.


## Parameters as stated in the abstracts

- “Each disc was treated for 60 seconds with the respective rotary brush according to the manufacturer's instructions.” — [Alabbad M et al. 2025](https://doi.org/10.1016/j.dental.2024.12.014) (in vitro).
- “Surface decontamination was performed for 2 min by the same examiner using one of the following devices: titanium brush (TiB), chitosan brush (ChB), or titanium curette (TiC).” — [Ince Kuka G et al. 2025](https://doi.org/10.3791/69521) (in vitro).
- “These were classified into four groups: untreated/control fixtures (n=5); fixtures treated with airflow using sodium bicarbonate powder (n=5); fixtures treated with an Er, Cr: YSGG laser system at 1.5 W power and a laser pulse of 30 Hz (n=5); and fixtures treated with titanium brush operating between 300 to 1000 rpm (n=5).” — [Ghaffar H et al. 2024](https://doi.org/10.7759/cureus.74645) (in vitro).
- “These were treated with TiBrushes (TiB), combination of TiB and photodynamic therapy (PDT), combination of TiB and 0.2%CHX/1%NaClO, plus or minus Ultraviolet-C (UV-C) radiation.” — [Sousa V et al. 2022](https://doi.org/10.3390/ijms231710033) (in vitro).
- “Diode laser, Ti brush, and Ti curette treatments were performed on the Grade 4 Ti discs, with/without treatment with 3% H2O2 solution or 0.2% CHX.” — [Bayrak M et al. 2022](https://doi.org/10.3390/nano12244481) (in vitro).
- “Acid-etched Ti discs were inoculated with human peri-implant plaque biofilms and mechanical antimicrobial interventions were applied on the Ti-bound biofilms for 30 seconds each: (1) rotary nylon brush; (2) Ti brush; (3) water-jet on high and (4) low, and compared to sterile, untreated and Chlorhexidine-treated controls.” — [Kotsakis GA et al. 2021](https://doi.org/10.1002/JPER.20-0186) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **TiBrush** — 8 entries
- **i-Brush** — 6 entries
- **Air-Flow** — 5 entries
- **Perio-Flow** — 4 entries
- **Ti-Brush** — 4 entries
- **NiTiBrush** — 1 entry
- **Labrida BioClean** — 1 entry
- **BioClean** — 1 entry
- **NiTi Brush** — 1 entry
- **R-Brush** — 1 entry
- **PerioFlow** — 1 entry
- **Waterlase** — 1 entry
- **Piezon** — 1 entry
- **PeriBrush** — 1 entry
- **Cavitron** — 1 entry
- **Vector** — 1 entry

Manufacturers: Straumann (7), EMS (7), Dentium (3), Biolase (3), Zimmer Biomet (3), Hu-Friedy (3), Neobiotech (2), Nobel Biocare (2), Dentsply (2), Sirona (2), Labrida (1), MegaGen (1), NeoBiotech (1), BioHorizons (1), Sweden & Martina (1), NSK (1), Camlog (1), Satelec (1), Komet (1), KaVo (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.
- **PeriBrush (Tigran Technologies AB)** — The Swedish company register lists Tigran Technologies AB (org. no. 556596-4417) with bankruptcy proceedings concluded on 29 September 2023 (status 'Konkurs avslutad'); a distributor page still presents the brand. Whether the PeriBrush is currently manufactured, stocked or supplied by a successor could not be confirmed from public information. Checked 2026-11-28; source: Ratsit company record for Tigran Technologies AB; Humanus Dental brand page.


## Chemical agents used alongside

Agents named in the same papers (16 different): saline (23), hydrogen peroxide (19), chlorhexidine (19), tetracycline (11), citric acid (9), antibiotics (systemic) (7), amoxicillin (4), sodium hypochlorite (3), EDTA (3), photosensitizer dye (3), minocycline (2), povidone-iodine (2), sterile water (2), phosphoric acid / etching gel (2), doxycycline (2), metronidazole (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (127)

The 127 entries of this chapter are too many for this page to stay readable in one request; they are listed in the [table of all entries, filtered on this method](https://www.nitibrush.com/articles/literature-index/all-entries/#method=titanium-niti-brush), and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [2. How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/)
- Next: [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)


---

# 4. Air-polishing and air-abrasive devices

Chapter 4 of an evidence-based reader on implant surface decontamination in peri-implantitis: 219 entries on air-polishing and air-abrasive devices — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/air-polishing/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about air-polishing (glycine, erythritol and other powders) on the implant surface?

**Key facts — Air-polishing and air-abrasive devices**

- Entries in this chapter: 219 of 819 (2000–2026): RCT 27 · clinical study 15 · case report/series 15 · systematic review 22 · review 23 · in vitro 102 · animal study 3 · not classified 12
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Figuero E et al. 2014](https://doi.org/10.1111/prd.12049) (521); [Bassetti M et al. 2014](https://doi.org/10.1111/clr.12155) (312)
- Products named by the authors: Air-Flow (15), Piezon (9), AIRFLOW (7), Perio-Flow (5), i-Brush (4), PerioFlow (3), TiBrush (3), Ti-Brush (3), GalvoSurge (2), Waterlase (2)
- Manufacturers named by the authors: EMS (31), Straumann (13), Hu-Friedy (7), Geistlich (6), KaVo (6), Nobel Biocare (6), Zimmer Biomet (4), Dentsply (4), Sirona (4), Biolase (3)
- Chemical agents used alongside: chlorhexidine (45), saline (44), hydrogen peroxide (20), citric acid (17), amoxicillin (12), tetracycline (10), antibiotics (systemic) (9), sterile water (9)
- Often studied together with: [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) (84), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (81), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (61), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (55)
- Entries naming the NiTi Brush: 6 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

A stream of compressed air, water and a powder (glycine, erythritol, sodium bicarbonate, calcium carbonate, trehalose and others are reported) directed at the implant surface through a nozzle, either non-surgically into the pocket with a subgingival tip or during surgery on the exposed surface. Powder type, grain size, pressure, distance and time differ between studies and are listed here as each abstract states them.


### Mechanism and use, as the papers describe it

Air-polishing, also written as air-powder abrasion, air abrasion or air powder water-jet technology in the publications in this chapter, delivers a powder in a stream of compressed air and water from a handpiece or nozzle onto the implant surface.[1,2] Kottmann et al. assumed that the bacterial reduction they measured with Perioflow was largely due to the mechanical effect of the air and water stream.[3] Powders named in the abstracts include glycine, erythritol, sodium bicarbonate, calcium carbonate, trehalose, tagatose, hydroxyapatite and calcium phosphate powders, and erythritol with chlorhexidine.[4,2,5,6,7]

In the non-surgical setting the powder is applied submarginally through a nozzle for sub-mucosal use, either as the only instrumentation or after curettes or ultrasonic tips.[8,9,10] In the surgical setting the exposed surface is treated after flap elevation with a supramucosal or a submucosal handpiece, and Stavropoulos et al. reported in a laboratory simulation that the handpiece type mattered according to defect configuration.[11,12] Product names in the abstracts include Perio-Flow, Air-Flow Perio, AIRFLOW Master Piezon, Cavitron JET Plus and PROPHYflex 3.[13,14,15,16,17]


### Reported operating conditions

Particle sizes stated in the abstracts are 40 µm for sodium bicarbonate and 14 µm for erythritol in one study, 65 µm and 40 µm sodium bicarbonate in another, and 40 µm bicarbonate in two further studies.[18,19,20,21] Air pressure is given as 25 to 55 psi by Wei et al., who found that higher pressure improved cleaning and increased surface change with a plateau effect, and as 2.4 bar with a water flow of 41.5 ml/min by Tastepe et al.[22,23] Tastepe et al. identified air pressure as the factor with the strongest effect on the cleaned area and reported that cleaning fell significantly when the nozzle was not moved.[1] Power settings are reported as 25% and 50%, and as power 5 and power 10.[24,11]

Working distance is stated as 5 mm in one disc study and as 3 mm and 6 mm in another.[20,24] Application times range from 5 s or 15 s per implant sextant, through 10 s, 45 s and 60 s per implant, to 120 s and 2 to 3 minutes per implant in defect models.[25,26,27,28,8,29] Mensi et al. and Bertl et al. reported less residue with the longer time in their ranges.[27,25]


### Effects on the implant surface reported in laboratory studies

A 2019 systematic review of in vitro studies considered air abrasion almost safe for the surface, particularly on non-modified surfaces, while noting that harder powders such as sodium bicarbonate tended to damage the surface more than glycine.[30] Matsubara et al. found that sodium bicarbonate was the only powder that significantly increased roughness at the collar and threads, whereas glycine and erythritol produced no significant change.[28] Wei et al. reported rounding of surface projections with all three powders tested and described a trade-off between cleaning and surface change.[22] Several disc and implant studies reported no or minimal topographic change after glycine or erythritol powders.[31,32,33] A 2026 systematic review of quantitative in vitro studies concluded that no universally safe tool for maintaining surface integrity could be identified.[34]

Powder remnants are reported: calcium phosphate particles embedded in the surface, more silicon after an erythritol-based than a glycine-based powder, and air-powder abrasive listed among methods leaving material remnants in the AAP/AO systematic review.[6,35,36] No laboratory protocol achieved complete removal of ink or biofilm, and apically facing threads and narrow defects retained the most residue.[26,37,25] Cell studies report 85% osteoblast-like cell coverage after erythritol air-polishing of biofilm-covered discs, while two studies found that no mechanical method returned cytocompatibility to pristine levels.[38,39,40] Strandstrem et al. reported dose-dependent cytotoxicity of all tested abrasives on human mesenchymal stromal cells, with erythritol highly cytotoxic in their assay.[41]


### Position in treatment protocols

In non-surgical trials air-polishing has been used alone and as an adjunct to curette or ultrasonic instrumentation.[9,42,10] Cosgarea et al. identified one RCT with a significant BOP reduction after air-polishing compared with control, Verket et al. found no difference between glycine air-polishing and ultrasonic cleaning in peri-implant mucositis, and Bi et al. detected no statistical differences between air polishing and comparative modalities in peri-implantitis.[43,44,45] Glycine air-polishing with titanium curettes also served as the baseline debridement in both arms of trials testing adjunctive photodynamic therapy.[46]

In surgical protocols air-polishing has been the surface step before autogenous bone grafting, a comparator to saline-soaked gauze, a comparator to implantoplasty, and one of three mechanical arms alongside plastic curettes and a titanium brush.[12,47,48,13] Ramanauskaite et al. concluded from two RCTs that glycine or erythritol air polishing did not improve BOP reduction compared with the control instrumentation in surgery.[49] Sodium bicarbonate air-powder abrasion has also been combined with chemical agents in ex vivo trials on implants explanted at open-flap surgery.[50,51]


### Limitations and open questions as stated by the authors

Authors of systematic reviews describe the clinical evidence as limited by few controlled studies and high heterogeneity, and call for longer follow-up and larger RCTs.[43,52] Treatment success remained low in several trials, at 19.2% of implants after erythritol air polishing or saline in resective surgery and 12% to 18% after adjunctive erythritol air-polishing or Er:YAG laser.[47,53] Selimović et al. reported added pain and discomfort with erythritol air-polishing, particularly in female patients, without added clinical benefit.[10] Subcutaneous emphysema is reported: one case associated with erythritol air-polishing in a pilot RCT, nine cases attributed to air-powder abrasive devices in a review with case, and a case of facial emphysema after open-flap air-powder abrasive debridement.[53,54,17] In the laboratory, authors caution that ink removal is not equivalent to biofilm decontamination and that the main drawback of air abrasion seems to be its limitation in restoring biocompatibility.[55,30]


### Sources cited in this description (55)

1. Tastepe CS et al. (2017). Parameters That Improve Cleaning Efficiency of Subgingival Air Polishing on Titanium Implant Surfaces: An In Vitro Study. *J Periodontol*. https://doi.org/10.1902/jop.2016.160270 · in vitro
2. Christian R. Hatz et al. (2022). An Umbrella Review on Low-Abrasive Air Powder Water Jet Technology in Periodontitis and Peri-Implantitis Patients *Applied Sciences*. https://doi.org/10.3390/app12147203 · review
3. Kottmann L et al. (2023). Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study. *Int J Implant Dent*. https://doi.org/10.1186/s40729-023-00469-z · in vitro
4. Tran C et al. (2023). Influence of eight debridement techniques on three different titanium surfaces: A laboratory study. *Int J Dent Hyg*. https://doi.org/10.1111/idh.12616 · in vitro
5. Di Tinco R et al. (2021). Evaluation of Antimicrobial Effect of Air-Polishing Treatments and Their Influence on Human Dental Pulp Stem Cells Seeded on Titanium Disks. *Int J Mol Sci*. https://doi.org/10.3390/ijms22020865 · in vitro
6. Tastepe CS et al. (2013). Cleaning and modification of intraorally contaminated titanium discs with calcium phosphate powder abrasive treatment. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2012.02536.x · in vitro
7. Drago L et al. (2014). Biofilm removal and antimicrobial activity of two different air-polishing powders: an in vitro study. *J Periodontol*. https://doi.org/10.1902/jop.2014.140134 · in vitro
8. Ronay V et al. (2017). In vitro cleaning potential of three implant debridement methods. Simulation of the non-surgical approach. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12773 · in vitro
9. Shiai Dai et al. (2026). Non-surgical treatment of peri-implantitis with submarginal erythritol air-polishing in severe periodontitis patients: a randomized controlled trial *BMC Oral Health*. https://doi.org/10.1186/s12903-026-07721-z · RCT
10. Armin Selimović et al. (2023). Non-surgical treatment of peri-implantitis with and without erythritol air-polishing a 12-month randomized controlled trial *BMC Oral Health*. https://doi.org/10.1186/s12903-023-02973-5 · RCT
11. Stavropoulos A et al. (2025). Factors Affecting the Efficacy of Airflowing in Cleaning Implant Surfaces in a Surgical Peri-Implantitis Treatment Simulation-A Laboratory Study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14464 · in vitro
12. Behneke A et al. (2000). Treatment of peri-implantitis defects with autogenous bone grafts: six-month to 3-year results of a prospective study in 17 patients. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/10697947/ · clinical study
13. Toma S et al. (2019). Clinical Evaluation of Three Surgical Modalities in the Treatment of Peri-Implantitis: A Randomized Controlled Clinical Trial. *J Clin Med*. https://doi.org/10.3390/jcm8070966 · RCT
14. Al Ghazal L et al. (2017). Comparison of two different techniques used for the maintenance of peri-implant soft tissue health: a pilot randomized clinical trial. *Acta Odontol Scand*. https://doi.org/10.1080/00016357.2017.1352101 · RCT
15. Özay F et al. (2026). Effect of Implant Surface Decontamination Procedures on Surface Morphology-In Vitro Study. *J Funct Biomater*. https://doi.org/10.3390/jfb17040166 · in vitro
16. Quintero DG et al. (2017). Air-Abrasive Disinfection of Implant Surfaces in a Simulated Model of Periimplantitis. *Implant Dent*. https://doi.org/10.1097/ID.0000000000000597 · in vitro
17. La Monaca G et al. (2021). Subcutaneous Facial Emphysema Following Open-Flap Air-Powder Abrasive Debridement for Peri-Implantitis: A Case Report and an Overview. *Int J Environ Res Public Health*. https://doi.org/10.3390/ijerph182413286 · case report/series
18. Pujarern P et al. (2024). Efficacy of Biofilm Removal on the Dental Implant Surface by Sodium Bicarbonate and Erythritol Powder Airflow System. *Eur J Dent*. https://doi.org/10.1055/s-0044-1779424 · in vitro
19. Samy Francis et al. (2023). Microbiological and Physical Changes Produced by Different Air–Powders on Contaminated Titanium Implant Surfaces: An In Vitro Pilot Study *Applied Sciences*. https://doi.org/10.3390/app13031301 · in vitro
20. Aida Meto et al. (2019). Differential Efficacy of Two Dental Implant Decontamination Techniques in Reducing Microbial Biofilm and Re-Growth onto Titanium Disks In Vitro *Applied Sciences*. https://doi.org/10.3390/app9153191 · in vitro
21. Conserva E et al. (2019). Evaluation of Biological Response of STRO-1/c-Kit Enriched Human Dental Pulp Stem Cells to Titanium Surfaces Treated with Two Different Cleaning Systems. *Int J Mol Sci*. https://doi.org/10.3390/ijms20081868 · not classified
22. Wei MCT et al. (2017). Effectiveness of implant surface debridement using particle beams at differing air pressures. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.74 · in vitro
23. Tastepe CS et al. (2018). Cleaning effect of osteoconductive powder abrasive treatment on explanted human implants and biofilm-coated titanium discs. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.100 · in vitro
24. Leung K et al. (2022). Decontamination of multispecies oral biofilm from rough implant surface by airflow with glycine. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.507 · in vitro
25. Kristina Bertl et al. (2025). Efficacy of Air Powder Water‐Jet Devices in Cleaning Implant Surfaces in a Non‐Surgical Peri‐Implantitis Treatment Simulation—A Laboratory Study *Clinical Oral Implants Research*. https://doi.org/10.1111/clr.14452 · in vitro
26. Sahrmann P et al. (2013). Cleaning potential of glycine air-flow application in an in vitro peri-implantitis model. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2012.02445.x · in vitro
27. Mensi M et al. (2020). Comparison between four different implant surface debridement methods: an in-vitro experimental study. *Minerva Stomatol*. https://doi.org/10.23736/S0026-4970.20.04342-3 · in vitro
28. Matsubara VH et al. (2020). Cleaning potential of different air abrasive powders and their impact on implant surface roughness. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.12875 · in vitro
29. Ozgu I et al. (2025). Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness. *J Vis Exp*. https://doi.org/10.3791/67778 · in vitro
30. Moharrami M et al. (2019). Effects of air abrasive decontamination on titanium surfaces: A systematic review of in vitro studies. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.12747 · systematic review
31. Tuchscheerer V et al. (2021). In vitro surgical and non-surgical air-polishing efficacy for implant surface decontamination in three different defect configurations. *Clin Oral Investig*. https://doi.org/10.1007/s00784-020-03476-1 · in vitro
32. Hui WL et al. (2021). Novel technique using cold atmospheric plasma coupled with air-polishing for the treatment of titanium discs grown with biofilm: An in-vitro study. *Dent Mater*. https://doi.org/10.1016/j.dental.2020.11.027 · in vitro
33. Cha JK et al. (2019). The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13446 · in vitro
34. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
35. Мелькумян Тимур Владимирович et al. (2022). Air Abrasion of Titanium Dental Implants with Water-Soluble Powders: An In Vitro Study *International Journal of Biomedicine*. https://doi.org/10.21103/article12(3)_oa15 · in vitro
36. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
37. Steiger-Ronay V et al. (2017). Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy. *BMC Oral Health*. https://doi.org/10.1186/s12903-017-0428-8 · in vitro
38. Matthes R et al. (2017). Osteoblast growth, after cleaning of biofilm-covered titanium discs with air-polishing and cold plasma. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12720 · in vitro
39. Jin SH et al. (2019). Decontamination methods to restore the biocompatibility of contaminated titanium surfaces. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2019.49.3.193 · in vitro
40. Ichioka Y et al. (2022). Mechanical removal of biofilm on titanium discs: An in vitro study. *J Biomed Mater Res B Appl Biomater*. https://doi.org/10.1002/jbm.b.34978 · in vitro
41. Elena B. Strandstrem et al. (2026). The effect of antiseptics and abrasives used for the treatment of peri-implantitis on the viability of multipotent human mesenchymal stromal cells in vitro *Genes and Cells*. https://doi.org/10.17816/gc704179 · in vitro
42. Nihal Eraydin et al. (2026). Efficacy of different nonsurgical treatments for peri-implantitis: a multi-arm randomized controlled clinical trial *Scientific Reports*. https://doi.org/10.1038/s41598-026-50332-5 · RCT
43. Cosgarea R et al. (2023). Efficacy of mechanical/physical approaches for implant surface decontamination in non-surgical submarginal instrumentation of peri-implantitis. A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13762 · systematic review
44. Verket A et al. (2023). Non-surgical therapy of peri-implant mucositis-Mechanical/physical approaches: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13789 · systematic review
45. Bi J et al. (2023). Effect of Air Polishing on the Treatment of Peri-Implant Diseases: A Systematic Review and Meta-Analysis. *J Oral Implantol*. https://doi.org/10.1563/aaid-joi-D-23-00114 · systematic review
46. Schär D et al. (2013). Anti-infective therapy of peri-implantitis with adjunctive local drug delivery or photodynamic therapy: six-month outcomes of a prospective randomized clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2012.02494.x · RCT
47. Hentenaar DFM et al. (2022). Erythritol air polishing in the surgical treatment of peri-implantitis: A randomized controlled trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13881 · RCT
48. Jérôme Frédéric Lasserre et al. (2020). Implantoplasty Versus Glycine Air Abrasion for the Surgical Treatment of Peri-implantitis: A Randomized Clinical Trial *The International Journal of Oral & Maxillofacial Implants*. https://doi.org/10.11607/jomi.6677 · RCT
49. Ramanauskaite A et al. (2023). Photo/mechanical and physical implant surface decontamination approaches in conjunction with surgical peri-implantitis treatment: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13783 · systematic review
50. Pranno N et al. (2021). Comparison of the effects of air-powder abrasion, chemical decontamination, or their combination in open-flap surface decontamination of implants failed for peri-implantitis: an ex vivo study. *Clin Oral Investig*. https://doi.org/10.1007/s00784-020-03578-w · RCT
51. La Monaca G et al. (2023). Effects of an amino acid buffered hypochlorite solution as an adjunctive to air-powder abrasion in open-flap surface decontamination of implants failed for peri-implantitis: an ex vivo randomized clinical trial. *Clin Oral Investig*. https://doi.org/10.1007/s00784-022-04608-5 · RCT
52. Nengwen Huang et al. (2024). The clinical efficacy of powder air-polishing in the non-surgical treatment of peri-implant diseases: A systematic review and meta-analysis *Japanese Dental Science Review*. https://doi.org/10.1016/j.jdsr.2024.05.003 · systematic review
53. Clementini M et al. (2026). Evaluation of the Adjunctive Use of Er:YAG Laser or Erythritol Air-Polishing in the Non-Surgical Treatment of Peri-Implantitis: A Pilot RCT. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70153 · RCT
54. Sung‐Tak Lee et al. (2018). Emphysema following air-powder abrasive treatment for peri-implantitis *Maxillofacial Plastic and Reconstructive Surgery*. https://doi.org/10.1186/s40902-018-0151-7 · not classified
55. Nicastro A et al. (2026). Comparison of Glycine Air Polishing and a Rotary Titanium Brush for the Removal of a Surrogate Surface Marker from Implants in Class Ib and IIIb Peri-Implant Defects: An In Vitro Study. *J Clin Med*. https://doi.org/10.3390/jcm15228771 · in vitro

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

27 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “The greatest numerical reductions in probing depth, bleeding on probing, and plaque index were observed when mechanical instrumentation was combined with glycine powder air abrasion; however, no statistically significant differences were detected among treatment groups.” — [Nihal Eraydin et al. 2026](https://doi.org/10.1038/s41598-026-50332-5), Scientific Reports; cited 3.
- “Irrespective of the adjunctive treatment modality, achievement of peri-implantitis therapeutic endpoint was limited across groups. Possible associations with treatment outcomes were observed; these findings require confirmation in larger studies.” — [Clementini M et al. 2026](https://doi.org/10.1111/clr.70153), Clin Oral Implants Res; cited 2.
- “The adjunctive use of XanCHX gel did not result in any statistically significant clinical benefit compared to PMPR alone in the treatment of PM up to 6 months, despite the reported clinical positive effects within the first month after treatment.” — [Curcio J et al. 2026](https://doi.org/10.1111/cid.70137), Clin Implant Dent Relat Res; cited 2.
- “In patients with severe periodontitis, both non-surgical therapies were effective in improving clinical parameters of peri-implantitis. Erythritol air-polishing exhibited greater improvement in soft tissue inflammation. Adequate peri-implant keratinized mucosa and greater reduction in probing depth of adjacent teeth were identified as favorable prognostic factors for PPD.” — [Shiai Dai et al. 2026](https://doi.org/10.1186/s12903-026-07721-z), BMC Oral Health; cited 1.
- “The application of i-PRF after a subgingival debridement using glycine air-polishing shows significant improvement of clinical parameters and a bone level stability for at least six months. However, if we consider that no bleeding on probing is needed to control the disease, none of the implants were considered successfully treated.” — [Laurie Deterville et al. 2025](https://doi.org/10.3389/fdmed.2025.1568889), Frontiers in Dental Medicine; cited 5.
- “Both erythritol-based air polishing and ultrasonic instrumentation with PEEK inserts are effective and comparable in the maintenance of peri-implant health. As treatment outcomes were independent of crown composition, the choice between modalities should be tailored to patient-specific needs and clinical conditions.” — [Carolina Maiorani et al. 2025](https://doi.org/10.3390/dj13060235), Dentistry Journal; cited 3.
- “Air polishing proved to be the most effective peri-implant mucosa cleaning protocol for reducing microbial biofilm formation, followed by ultrasonic cleaning. Manual brushing alone showed limited efficacy in controlling biofilm. Implementing efficient cleaning protocols is crucial for preventing peri-implant diseases and enhancing implant success.” — [Mukesh Soni et al. 2025](https://doi.org/10.4103/jpbs.jpbs_1923_24), Journal of Pharmacy And Bioallied Sciences; cited 0.
- “This study confirms that conventional non-surgical management of peri-implantitis produces limited clinical improvement. It is shown that an erythritol air-polishing system may not produce added clinical benefits when used adjunctive to conventional non-surgical management. In other words, neither approach effectively resolved peri-implantitis.” — [Armin Selimović et al. 2023](https://doi.org/10.1186/s12903-023-02973-5), BMC Oral Health; cited 28.
- “The diode laser enabled improvements in clinical parameters in the peri-implant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.” — [Altindal D et al. 2023](https://doi.org/10.5051/jpis.2203140157), J Periodontal Implant Sci; cited 18.
- “AP, with or without AEW, is an effective method in removing biofilm from peri-implantitis-affected implants.” — [Ichioka Y et al. 2023](https://doi.org/10.1111/jcpe.13836), J Clin Periodontol; cited 7.

17 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

22 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Current evidence consistently indicates that saliva contamination may adversely affect early biological responses and the osseointegration process by altering titanium surface properties, particularly surface wettability and surface energy. However, as these data are largely derived from in vitro and animal models, caution is warranted when extrapolating the findings to clinical practice.” — [Çi̇ftçi̇ S et al. 2026](https://doi.org/10.1186/s12903-026-08289-4), BMC Oral Health; cited 0.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “Both PDT and laser therapy are effective in reducing the microbial load. Additionally, laser causes the least surface alterations, with some studies reporting minor improvements in implant surface properties.” — [Maedeh Masoumzadeh et al. 2025](https://doi.org/10.18502/fid.v22i49.20330), Frontiers in Dentistry; cited 0.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.
- “Leave-one-out analysis confirmed the stability of the results. The findings highlight the need for future research with longer-term follow-up and high-quality, multi-center, large-sample RCTs.” — [Nengwen Huang et al. 2024](https://doi.org/10.1016/j.jdsr.2024.05.003), Japanese Dental Science Review; cited 18.
- “In the nonsurgical treatment of peri-implantitis, solid-state lasers yielded positive influence in term of PD, BOP and CAL, while diode laser provided no beneficial effect. Future well-designed large RCTs are still needed, considering the limitations of included studies.” — [Nengwen Huang et al. 2024](https://doi.org/10.1186/s40729-024-00570-x), International Journal of Implant Dentistry; cited 16.

14 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

15 non-randomised clinical studies and 15 case reports or series.

- “Within the limitations of this retrospective study, both electrolytic and conventional mechanical implant surface decontamination protocols resulted in significant short-term clinical and radiographic improvements following peri-implantitis surgery. Electrolytic cleaning demonstrated outcomes comparable to conventional therapy and may represent a viable alternative for implant surface decontamination.” — [De Angelis N et al. 2026](https://doi.org/10.3390/dj14070447), Dent J (Basel); cited 0.
- “The use of an air-water abrasive mixture based on sodium bicarbonate followed by irrigation with 0,01% Miramistin provided the most pronounced reduction in clinical symptoms, stabilization of bone loss, and a decreased need for surgical treatment, which allows it to be recommended for implant surface decontamination in the treatment of peri-implantitis.” — [Elena B. Strandstrem et al. 2026](https://doi.org/10.33667/2078-5631-2026-20-110-115), Medical alphabet; cited 0.
- “Peri-implantitis arises from interactions among oral hygiene, anatomical factors, and systemic conditions. Subgingival sandblasting effectively controls peri-implantitis progression by disrupting plaque biofilm and suppressing inflammation, with erythritol offering extended anti-inflammatory benefits. Sustained clinical outcomes needs adjunctive maintenance therapy alongside subgingival sandblasting.” — [Taohua Pan et al. 2025](https://doi.org/10.1186/s12903-025-06945-9), BMC Oral Health; cited 4.
- “Therapy reduced mucositis from 70% to 23%. Overall, while TNF-α levels alone may not conclusively differentiate between healthy and mucositis-affected sites in every context, they do appear to correlate with improvements in peri-implant health following therapeutic intervention.” — [Juliana Prazeres Gonçalves de Castro et al. 2025](https://doi.org/10.1590/0103-644020256205), Brazilian Dental Journal; cited 0.
- “The choice of decontamination method for the treatment of peri-implantitis should take into account the surface type and characteristics of the dental implant. The Er, Cr:YSGG laser proved to be a universal and effective method, while Air Flow and Vector Paro were more efficient when used for specific surface types.” — [Maksim V. Sokolov et al. 2025](https://doi.org/10.17116/rosstomat20251803126), Russian Journal of Stomatology; cited 0.
- “The obtained results underscore the necessity of selecting the surface treatment method according to the implant surface type to preserve its functional properties and ensure successful re-osseointegration.” — [Maksim V. Sokolov et al. 2025](https://doi.org/10.17116/rosstomat20251804132), Russian Journal of Stomatology; cited 0.

9 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

102 in vitro / ex vivo and 3 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “From this study, air polishing devices should be used with caution with titanium, PEEK, and zirconia; Prophy paste should be used with caution with titanium and lithium disilicate; and P5 scaler should be used with caution with zirconia. Further studies are required to study the clinical outcomes.” — [Pujarern P et al. 2026](https://doi.org/10.1055/s-0046-1818622), Eur J Dent; cited 1.
- “Exploratory SEM-EDS observations of individual specimens showed differences in surface appearance. Within the limitations of this in vitro model, residual dye coverage differed by protocol, and no protocol resulted in a dye-free surface.” — [Bayraktar Ayakta B et al. 2026](https://doi.org/10.3791/73564), J Vis Exp; cited 0.
- “From the perspective of preserving the regenerative potential of MSC-AT, diluted benzyldimethyl-myristoylamino-propylammonium and sodium bicarbonate are the most biocompatible agents for surface decontamination. The use of octenidine dihydrochloride 0.1% + 2-phenoxyethanol 2% and erythritol at clinically relevant concentrations is associated with irreversible damage to progenitor cells.” — [Elena B. Strandstrem et al. 2026](https://doi.org/10.17816/gc704179), Genes and Cells; cited 0.
- “All mechanical instrumentation modalities altered titanium and zirconia surfaces to varying degrees. On titanium, EPAP was associated with a favourable combination of high cleaning efficacy and preserved native surface morphology. On zirconia, both air-polishing modalities achieved high cleaning efficacy with minimal topographical alteration.” — [Kamel MS et al. 2026](https://doi.org/10.1111/clr.70182), Clin Oral Implants Res; cited 0.
- “, the wettability and surface roughness of dental implant material surfaces were greatly impacted by all surface treatment techniques.By generating the lowest contact angle values, chemical cleaning with citric acid demonstrated the greatest increase in wettability.While glycine powder air-abrasion produced enhanced surface roughness with favorable wettability, mechanical implantoplasty/ polishing produced the …” — [Naman Awasthi et al. 2026](https://doi.org/10.5005/jp-journals-10024-4062), The Journal of Contemporary Dental Practice; cited 0.
- “In this surrogate-marker model, the relative performance of the two instruments depended on defect morphology. The interaction rests on the combination of a higher value for air polishing and a lower, more variable one for the brush in class IIIb defects, and it is not robust to the omission of the three lowest brush values.” — [Nicastro A et al. 2026](https://doi.org/10.3390/jcm15228771), J Clin Med; cited 0.

96 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “All treatments resulted in partial regeneration of the defects. No treatment group showed a significantly (p < 0.05) better outcome. However, pretreatment with air polishing showed a tendency for less inflammation. Noteworthy, inflammation assessment showed an overall irritative potential after GBR in the evaluated early healing phase.” — [Alex Solderer et al. 2020](https://doi.org/10.1007/s00784-020-03572-2), Clinical Oral Investigations; cited 10.
- “The results of this experimental study indicated that there is no significant difference between new dental implants and re-used dental implants with regards to osseointegration around the implant.” — [Murat Ulu et al. 2018](https://doi.org/10.1186/s40729-018-0130-x), International Journal of Implant Dentistry; cited 3.
- “These results support the hypothesis that CO2 laser-assisted therapy of ailing implants will not result in excessive titanium concentrations in tissues. Accordingly, CO2 lasers appear suitable and safe for peri-implant gingival surgery.” — [Deppe H et al. 2002](https://pubmed.ncbi.nlm.nih.gov/12381072/), Int J Oral Maxillofac Implants.


## Parameters as stated in the abstracts

- “Methods. 48 patients with moderate peri-implantitis were divided into 3 groups of treatment: sodium bicarbonate and 0,01% Miramistin; erythritol and 0,05% Chlorhexidine; and glycine and Octenisept.” — [Elena B. Strandstrem et al. 2026](https://doi.org/10.33667/2078-5631-2026-20-110-115) (clinical study).
- “The use of octenidine dihydrochloride 0.1% + 2-phenoxyethanol 2% and erythritol at clinically relevant concentrations is associated with irreversible damage to progenitor cells.” — [Elena B. Strandstrem et al. 2026](https://doi.org/10.17816/gc704179) (in vitro).
- “The entire implant periphery was instrumented for 5 or 15s per implant sextant (i.e., in total 30 or 90s per implant), with one of two different APWJ devices using either a glycine or an erythritol powder.” — [Kristina Bertl et al. 2025](https://doi.org/10.1111/clr.14452) (in vitro).
- “Erythritol powder, PEEK ultrasonic tips, and titanium curettes were applied for 2 min in Class 1A defects and 3 minutes in Class 1B defects.” — [Ozgu I et al. 2025](https://doi.org/10.3791/67778) (in vitro).
- “Implants were instrumented with an airflowing device using a supra- or submucosal handpiece, with three settings: (a) power 5, 5 s (b) power 10, 5 s, and (c) power 5, 15 s per implant/defect sextant.” — [Stavropoulos A et al. 2025](https://doi.org/10.1111/clr.14464) (in vitro).
- “All underwent clinical and radiographic exams and received non-invasive therapy (mechanical debridement, with ultrasonic scalers to remove calculus and sodium air-abrasive polishing to eliminate soft debris from the implant and prosthetic components + 0.12% chlorhexidine).” — [Juliana Prazeres Gonçalves de Castro et al. 2025](https://doi.org/10.1590/0103-644020256205) (clinical study).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Air-Flow** — 15 entries
- **Piezon** — 9 entries
- **AIRFLOW** — 7 entries
- **Perio-Flow** — 5 entries
- **i-Brush** — 4 entries
- **PerioFlow** — 3 entries
- **TiBrush** — 3 entries
- **Ti-Brush** — 3 entries
- **GalvoSurge** — 2 entries
- **Waterlase** — 2 entries
- **Cavitron** — 2 entries
- **PIEZON** — 1 entry
- **Perisolv** — 1 entry
- **R-Brush** — 1 entry
- **AirFlow** — 1 entry
- **EMS Air-Flow** — 1 entry
- **Vector** — 1 entry

Manufacturers: EMS (31), Straumann (13), Hu-Friedy (7), Geistlich (6), KaVo (6), Nobel Biocare (6), Zimmer Biomet (4), Dentsply (4), Sirona (4), Biolase (3), Neobiotech (2), Dentium (2), Sweden & Martina (2), Komet (2), Camlog (2), Satelec (2), MegaGen (1), NeoBiotech (1), BioHorizons (1), NSK (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (21 different): chlorhexidine (45), saline (44), hydrogen peroxide (20), citric acid (17), amoxicillin (12), tetracycline (10), antibiotics (systemic) (9), sterile water (9), metronidazole (8), photosensitizer dye (6), sodium hypochlorite (6), minocycline (5), doxycycline (4), povidone-iodine (4), phosphoric acid / etching gel (3), ozone (2), hypochlorous acid (2), chloramine (2), enamel matrix derivative (2), Perisolv (1), EDTA (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (219)

The 219 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/air-polishing/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [3. Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/)
- Next: [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)


---

# 5. Lasers

Chapter 5 of an evidence-based reader on implant surface decontamination in peri-implantitis: 283 entries on lasers — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/laser/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about laser decontamination of the implant surface (Er:YAG, Er,Cr:YSGG, diode, CO₂, Nd:YAG)?

**Key facts — Lasers**

- Entries in this chapter: 283 of 819 (2000–2026): RCT 25 · clinical study 34 · case report/series 18 · systematic review 40 · review 28 · in vitro 102 · animal study 11 · not classified 25
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Aoki A et al. 2015](https://doi.org/10.1111/prd.12080) (457); [Frank Schwarz et al. 2011](https://doi.org/10.1111/j.1600-051x.2010.01690.x) (294)
- Products named by the authors: Waterlase (6), Air-Flow (6), LightWalker (3), Piezon (3), GalvoSurge (2), Cavitron (2), TiBrush (2), Perisolv (2), Perio-Flow (1), Ti-Brush (1)
- Manufacturers named by the authors: Straumann (16), Biolase (11), EMS (7), Fotona (7), Geistlich (6), Dentsply Sirona (5), Hu-Friedy (5), Nobel Biocare (4), Dentsply (4), Sirona (4)
- Chemical agents used alongside: chlorhexidine (47), saline (41), photosensitizer dye (28), hydrogen peroxide (22), antibiotics (systemic) (18), amoxicillin (15), sterile water (13), citric acid (10)
- Often studied together with: [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) (77), [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (61), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (59), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (54)
- Entries naming the NiTi Brush: 1 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Laser light of a given wavelength applied to the implant surface to remove or inactivate biofilm, alone or after mechanical debridement. The wavelengths reported are erbium (Er:YAG, Er,Cr:YSGG), diode (various wavelengths), carbon dioxide and neodymium (Nd:YAG); power, pulse energy, frequency, water spray and exposure time vary widely and are quoted as stated.


### Mechanism and use, as the papers describe it

The publications in this chapter describe laser light directed at the implant surface from neodymium (Nd:YAG), carbon dioxide (CO2), diode, erbium (Er:YAG) and erbium-chromium (Er,Cr:YSGG) devices.[1] The wavelengths named are Nd:YAG at 1,064 nm, Er,Cr:YSGG at 2,780 nm, Er:YAG at 2,940 nm, CO2 at 9,300 nm and 10,600 nm, diodes at 445 nm and from 808 nm to 980 nm, and a 308 nm excimer laser in one laboratory study.[2,3,4,5,6,7,8] The effects ascribed to the light are a reduction of bacteria on the implant surface and surrounding tissues together with cutting and coagulation.[9] Erbium wavelengths are described as removing calculus and calcified deposits from the titanium microstructure and, at higher fluence, as stripping the contaminated oxide layer.[10,11,12,13] Low-energy Nd:YAG and 808 nm diode irradiation were also reported to attenuate the response of cultured cells to lipopolysaccharide adherent to titanium.[14,4]

In the clinical entries the laser is applied into the pocket during non-surgical treatment or onto the exposed surface after flap elevation.[15,16] Non-surgical use is described for mucositis and peri-implantitis with diode, Er:YAG and Er,Cr:YSGG devices, usually in the same session as mechanical debridement, and in one trial as repeated diode applications on days 0, 7 and 14.[5,17,18,19] Surgical use is described for Er:YAG on the intrabony surface after implantoplasty, for Er:YAG and Er,Cr:YSGG before grafting, for CO2 before augmentation, and for a combined Nd:YAG and Er:YAG approach.[20,21,22,23,24] Delivery is reported in contact or non-contact mode through fibres, sapphire or quartz tips and conical, end-firing or side-firing tips, with or without an air-water spray.[25,26,27,28]


### Reported operating conditions

Er:YAG pulse energies in the abstracts range from 30 mJ to 320 mJ at 10 Hz to 30 Hz, with 100 mJ at 10 Hz used on implants before explantation, 30 mJ to 50 mJ at 30 Hz with water spray for microstructured surfaces, and 60 mJ and 80 mJ groups in one clinical trial.[10,29,30,31] Energy densities are quoted as 3.76 J/cm2 to 14.2 J/cm2 per pulse and 20.3 J/cm2 or 38.2 J/cm2 in non-contact mode, with pulse durations of 50 µs to 600 µs, exposure of 1 to 2 minutes, and one protocol specifying an 8 mm sapphire tip, air 6 and water 4 at 2 mm/s.[32,11,13,33,34] Er,Cr:YSGG settings are given as 1.5 W, 30 Hz and 50 mJ with 40 to 50 per cent air and water, 0.75 W at 100 Hz, 2.5 W at 30 Hz for 30 s, and 0.5 W to 2 W at 20 Hz under irrigation.[22,35,28,36,37]

Diode parameters span 810 nm at 1.0 W pulsed and 3 J/cm2 for 1 minute, 970 nm at 1.2 W continuous wave, 808 nm at 2 W continuous wave or pulsed at 20 kHz through a 600 µm fibre for 1 minute, and 810 nm at an average of 3.84 W for two or three 15 s repetitions.[5,6,4,38] Laboratory series tested 1 W to 15 W, while 445 nm protocols used 0.5 W pulsed or 2 W to 3 W continuous wave at 1 mm distance and 0.8 W to 3 W at duty cycles of 10 to 100 per cent for 5 s to 20 s.[39,40,41,42,43] CO2 settings include superpulsed 7 W at 80 Hz on a wet surface, pulsed non-contact 1 W to 5 W, continuous-wave 2 W defocused, and a 9.3 µm device at 13.9 W with mist for one minute.[44,45,46,47] Nd:YAG was applied at 1 W to 6 W with 50 mJ to 350 mJ in contact, and in Q-switched mode at 0.597 J/cm2 per pulse with 6 ns pulses for 2 s at 0.5 mm from the surface.[45,41,48,49]


### Effects on the implant surface reported in laboratory studies

Scanning electron microscopy showed extensive melting after conventional Nd:YAG irradiation at 2 W to 6 W, damage proportional to power, and no change with a 980 nm diode at 5 W to 15 W or CO2 at 1 W or 2 W, whereas CO2 at 3.5 W to 5 W destroyed micromachined grooves.[41,45] A five-wavelength comparison found no to minimal alteration with Er,Cr:YSGG and Er:YAG, more evident alteration with Nd:YAG and diode at high power, and the most prominent damage with Nd:YAG.[50] Diode melting or flattening was reported at 4.5 W to 5.5 W and at 2 W to 3 W with 940 nm.[40,39] For erbium lasers, reduced ridge sharpness at 140 mJ to 180 mJ, cracks and melting at 100 mJ or 200 mJ, a 0.25 µm smoother surface and ready damage of anodised surfaces are described alongside reports of unchanged roughness.[34,51,52,29,53] Conical tips produced no surface effect at any setting, effects with conventional optics were dose related, and water reduced the influence of irradiation.[26] Titanium ions were not detected after CO2 or Er,Cr:YSGG irradiation.[46]

Er:YAG at 60 mJ to 120 mJ kept the implant-bone interface below 47 °C over 120 s, rises stayed below 10 °C with and without spray in another model, and contact Er:YAG produced a focal rise to 58 °C in a biofilm study.[54,55,56] Diodes at 2 W continuous wave reached a 10 °C rise within 12 s to 14 s, a 445 nm diode exceeded 10 °C at 0.8 W continuous wave for 5 s, and a 940 nm diode reached 185 °C on an RBM surface at 3 W pulsed for 60 s, while rises stayed below 10 °C up to 1 W in porcine ribs.[57,3,58,59] Residual biofilm after Er:YAG is reported as 32.8 per cent of disc area against 74.0 per cent untreated, and as a lower debridement index than mechanical methods on explanted implants, with no method leaving a pristine surface.[60,61] Cell studies report osteoblast attachment on Er:YAG-treated discs, higher fibroblast and osteoblast counts after Er:YAG or Er,Cr:YSGG than on untreated contaminated surfaces, preserved biocompatibility after 808 nm diode treatment, fewer spreading cells after CO2 at 6 W or 8 W, and a cellular response that remained below that of pristine implants.[13,62,63,64,65,66,67]


### Position in treatment protocols

In non-surgical trials the laser is an adjunct to instrumentation with curettes, ultrasonic devices or air-polishing, and in a few trials the sole decontamination measure.[15,17,19] A 2014 meta-analysis reported a weighted mean difference of 0.00 mm in probing depth reduction between laser and conventional non-surgical treatment, and a 2023 systematic review found significant probing depth reductions over control only in an Er,Cr:YSGG group at 6 months.[68,15] A 2024 meta-analysis concluded that solid-state lasers improved probing depth, bleeding and attachment level while diode lasers provided no additional effect, and diode-only meta-analyses reported no advantage over mechanical debridement alone.[69,70,71] Two randomised trials comparing non-surgical diode treatment with flap surgery reported greater pocket reduction after surgery and described the laser as a less invasive option for non-advanced defects.[19,6]

In surgical protocols the laser decontaminates the exposed surface after granulation tissue removal, with or without implantoplasty, before resective or augmentative measures.[20,72] Schwarz et al. reported that Er:YAG and plastic curettes with saline gave comparable outcomes of combined surgery at 6 months, 4 years and 7 years.[20,73,74] A 2022 meta-analysis found a lack of added effect of Er:YAG on probing depth reduction, and a 2023 review of five trials judged the evidence inconclusive.[75,76] Individual trials reported higher probing depth reduction with adjunctive Er:YAG in regenerative therapy and greater reduction in bleeding sites with combined Nd:YAG and Er:YAG, while adjunctive diode laser showed no long-term effect in non-regenerative surgery.[21,24,77] Animal studies describe new bone on Er:YAG-treated surfaces and no apparent effect of CO2 with hydrogen peroxide on re-osseointegration.[78,79,80]


### Limitations and open questions as stated by the authors

Review authors cite small samples, short follow-up and heterogeneous protocols as reasons why no firm conclusion can be drawn, and one attributes inconclusive surgical findings to non-uniform control groups and laser parameters.[1,15,76] Adjunctive benefit is described as limited to the short term, radiographic outcomes were reported without consistent statistical significance, and microbiological evidence was graded very low in certainty.[81,82,83,84] Laboratory reviews concluded that no universally safe tool for surface integrity could be identified and that laser parameters, implant material and geometry govern the temperature response.[85,3] Authors also call for trials using the 2018 classification and for uniform protocols with longer follow-up.[86,87,88]


### Sources cited in this description (88)

1. Natto ZS et al. (2015). Comparison of the efficacy of different types of lasers for the treatment of peri-implantitis: a systematic review. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.3846 · systematic review
2. Linden E et al. (2021). SEM Evaluation of the Effects of Laser-Mediated Implant Surface Decontamination: An In Situ Human Pilot Study. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.4911 · in vitro
3. Herbert Deppe et al. (2021). Thermal effect of a 445 nm diode laser on five dental implant systems: an in vitro study *Scientific Reports*. https://doi.org/10.1038/s41598-021-99709-8 · in vitro
4. Giannelli M et al. (2016). The effects of diode laser on Staphylococcus aureus biofilm and Escherichia coli lipopolysaccharide adherent to titanium oxide surface of dental implants. An in vitro study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-016-2025-5 · in vitro
5. Volkan Arısan et al. (2015). A Randomized Clinical Trial of an Adjunct Diode Laser Application for the Nonsurgical Treatment of Peri-Implantitis *Photomedicine and Laser Surgery*. https://doi.org/10.1089/pho.2015.3956 · RCT
6. Malmqvist S et al. (2025). Treatment of peri-implantitis with diode laser or mucosal flap surgery: A clinical randomized controlled trial. *J Periodontol*. https://doi.org/10.1002/JPER.24-0683 · RCT
7. Giulia Maria Mariani et al. (2020). One-year clinical outcomes following non-surgical treatment of peri-implant mucositis with adjunctive diode laser application *Minerva Dental and Oral Science*. https://doi.org/10.23736/s0026-4970.20.04340-x · clinical study
8. Deppe H et al. (2007). Effect of 308-nm excimer laser light on peri-implantitis-associated bacteria: an in vitro investigation. *Lasers Med Sci*. https://doi.org/10.1007/s10103-007-0441-2 · in vitro
9. Romanos GE et al. (2009). Laser wavelengths and oral implantology. *Lasers Med Sci*. https://doi.org/10.1007/s10103-009-0676-1 · review
10. Schwarz F et al. (2003). \[Influence of an Er:YAG laser on the surface structure of titanium implants\]. *Schweiz Monatsschr Zahnmed*. https://pubmed.ncbi.nlm.nih.gov/12872590/ · clinical study
11. Takagi T et al. (2018). Effective removal of calcified deposits on microstructured titanium fixture surfaces of dental implants with erbium lasers. *J Periodontol*. https://doi.org/10.1002/JPER.17-0389 · in vitro
12. Yamamoto A et al. (2013). Treatment of peri-implantitis around TiUnite-surface implants using Er:YAG laser microexplosions. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.1593 · animal study
13. Giannelli M et al. (2017). Effects of an Erbium:Yttrium-Aluminum-Garnet Laser and Ultrasonic Scaler on Titanium Dioxide-Coated Titanium Surfaces Contaminated With Subgingival Plaque: An In Vitro Study to Assess Post-Treatment Biocompatibility With Osteogenic Cells. *J Periodontol*. https://doi.org/10.1902/jop.2017.170195 · clinical study
14. Giannelli M et al. (2009). In vitro evaluation of the effects of low-intensity Nd:YAG laser irradiation on the inflammatory reaction elicited by bacterial lipopolysaccharide adherent to titanium dental implants. *J Periodontol*. https://doi.org/10.1902/jop.2009.080648 · in vitro
15. Cosgarea R et al. (2023). Efficacy of mechanical/physical approaches for implant surface decontamination in non-surgical submarginal instrumentation of peri-implantitis. A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13762 · systematic review
16. Ramanauskaite A et al. (2023). Photo/mechanical and physical implant surface decontamination approaches in conjunction with surgical peri-implantitis treatment: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13783 · systematic review
17. Viveca Wallin Bengtsson et al. (2025). Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-025-00591-0 · RCT
18. Clementini M et al. (2026). Evaluation of the Adjunctive Use of Er:YAG Laser or Erythritol Air-Polishing in the Non-Surgical Treatment of Peri-Implantitis: A Pilot RCT. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70153 · RCT
19. Dena Hashim et al. (2025). A randomised clinical trial comparing a surgical approach for treatment of peri-implantitis to non-surgical debridement with adjunctive diode laser therapy *Clinical Oral Investigations*. https://doi.org/10.1007/s00784-025-06204-9 · RCT
20. Frank Schwarz et al. (2011). Impact of the method of surface debridement and decontamination on the clinical outcome following combined surgical therapy of peri-implantitis: a randomized controlled clinical study *Journal Of Clinical Periodontology*. https://doi.org/10.1111/j.1600-051x.2010.01690.x · RCT
21. Wang CW et al. (2021). Laser-assisted regenerative surgical therapy for peri-implantitis: A randomized controlled clinical trial. *J Periodontol*. https://doi.org/10.1002/JPER.20-0040 · RCT
22. Nevins M et al. (2020). Human Histologic Evaluations of the Use of Er,Cr:YSGG Laser to Decontaminate an Infected Dental Implant Surface in Preparation for Implant Reosseointegration. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.5139 · clinical study
23. Romanos GE et al. (2008). Regenerative therapy of deep peri-implant infrabony defects after CO2 laser implant surface decontamination. *Int J Periodontics Restorative Dent*. https://pubmed.ncbi.nlm.nih.gov/18605600/ · clinical study
24. Fragkioudakis I et al. (2023). Surgical Treatment of Peri-Implantitis Using a Combined Nd: YAG and Er: YAG Laser Approach: Investigation of Clinical and Bone Loss Biomarkers. *Dent J (Basel)*. https://doi.org/10.3390/dj11030061 · clinical study
25. Chegeni E et al. (2020). Effect of an Er,Cr:YSGG Laser on the Surface of Implants: A Descriptive Comparative Study of 3 Different Tips and Pulse Energies. *Dent J (Basel)*. https://doi.org/10.3390/dj8040109 · in vitro
26. Thomas Fenelon et al. (2020). Effects of Lasers and Their Delivery Characteristics on Machined and Micro-Roughened Titanium Dental Implant Surfaces *Bioengineering*. https://doi.org/10.3390/bioengineering7030093 · in vitro
27. Walinski CJ et al. (2020). Resin cement removal from titanium dental implant surface using a novel side-firing laser fiber and Er,Cr:YSGG irradiation. *Am J Dent*. https://pubmed.ncbi.nlm.nih.gov/32794390/ · in vitro
28. Kottmann L et al. (2023). Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study. *Int J Implant Dent*. https://doi.org/10.1186/s40729-023-00469-z · in vitro
29. Taniguchi Y et al. (2013). Optimal Er:YAG laser irradiation parameters for debridement of microstructured fixture surfaces of titanium dental implants. *Lasers Med Sci*. https://doi.org/10.1007/s10103-012-1171-7 · in vitro
30. Sobierajska P et al. (2026). The Effect of the Er3+:YAG Laser Decontamination Process on the Surface of Titanium Alloys, Depending on the Exposure Parameters. *Materials (Basel)*. https://doi.org/10.3390/ma19040775 · in vitro
31. Xiaoying Dai et al. (2025). Evaluation of the therapeutic effects of Er:YAG laser with different parameters on peri-implantitis *Medicine*. https://doi.org/10.1097/md.0000000000044061 · RCT
32. Nejem Wakim R et al. (2018). Decontamination of Dental Implant Surfaces by the Er:YAG Laser Beam: A Comparative in Vitro Study of Various Protocols. *Dent J (Basel)*. https://doi.org/10.3390/dj6040066 · in vitro
33. Secgin-Atar A et al. (2021). Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study. *Nanomaterials (Basel)*. https://doi.org/10.3390/nano11102602 · in vitro
34. Kim JH et al. (2011). The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2011.41.5.234 · in vitro
35. Hashim A et al. (2024). Comparison of the efficacy of Er,Cr:YSGG laser on oral biofilm removal from implant surfaces with various application times for the treatment of peri-implantitis defects: ex vivo study. *BMC Oral Health*. https://doi.org/10.1186/s12903-024-04698-5 · RCT
36. Chedid C et al. (2026). Comparative Efficacy of Er,Cr:YSGG Laser, Electrolytic Cleaning, and Chlorhexidine for the Decontamination of Sandblasted, Large-Grit, Acid-Etched (SLA) Implant Surfaces: An In Vitro Controlled Study. *Cureus*. https://doi.org/10.7759/cureus.113294 · in vitro
37. Lin CJ et al. (2022). The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study. *J Funct Biomater*. https://doi.org/10.3390/jfb13030133 · in vitro
38. Wawrzyk A et al. (2022). Analysis of the Microbiome on the Surface of Corroded Titanium Dental Implants in Patients with Periimplantitis and Diode Laser Irradiation as an Aid in the Implant Prosthetic Treatment: An Ex Vivo Study. *Materials (Basel)*. https://doi.org/10.3390/ma15175890 · clinical study
39. Mostafa Ahmed Rezeka et al. (2024). Evaluation of the effect of diode laser application on the hydrophilicity, surface topography, and chemical composition of titanium dental implant surface *Journal of Prosthodontics*. https://doi.org/10.1111/jopr.13823 · in vitro
40. Faramarzi M et al. (2018). Evaluation of surface changes of dental implants after irradiation with diode laser beams with different energies: A SEM study. *J Adv Periodontol Implant Dent*. https://doi.org/10.15171/japid.2018.013 · in vitro
41. Romanos GE et al. (2000). Effects of diode and Nd:YAG laser irradiation on titanium discs: a scanning electron microscope examination. *J Periodontol*. https://doi.org/10.1902/jop.2000.71.5.810 · in vitro
42. Pergolini D et al. (2023). SEM Evaluation of Thermal Effects Produced by a 445 nm Laser on Implant Surfaces. *Dent J (Basel)*. https://doi.org/10.3390/dj11060148 · in vitro
43. Ahrens M et al. (2024). Bacterial reduction and temperature increase of titanium dental implant models treated with a 445 nm diode laser: an in vitro study. *Sci Rep*. https://doi.org/10.1038/s41598-024-68780-2 · in vitro
44. Mouhyi J et al. (2000). Re-establishment of the atomic composition and the oxide structure of contaminated titanium surfaces by means of carbon dioxide laser and hydrogen peroxide: an in vitro study. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/j.1708-8208.2000.tb00117.x · clinical study
45. Park CY et al. (2005). Surface properties of endosseous dental implants after NdYAG and CO2 laser treatment at various energies. *J Oral Maxillofac Surg*. https://doi.org/10.1016/j.joms.2005.06.015 · in vitro
46. Romanos GE et al. (2026). Spectrometric Analysis of Titanium Particle Release Based on Various Implant Surface Detoxification Methods. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11375 · in vitro
47. Scott H. Froum et al. (2025). Periimplantitis Surface Decontamination and Integrity Following Use of Co2 Laser or Water Irrigation and Mechanical Therapy: A Comparison Study **. https://doi.org/10.61440/jsdr.2025.v3.26 · in vitro
48. Namour M et al. (2019). Q-Switch Nd:YAG Laser-Assisted Decontamination of Implant Surface. *Dent J (Basel)*. https://doi.org/10.3390/dj7040099 · in vitro
49. Namour M et al. (2021). Assessment of Disinfection Potential of Q-Switch Nd: YAG Laser on Contaminated Titanium Implant Surfaces. *Materials (Basel)*. https://doi.org/10.3390/ma14206078 · in vitro
50. Sedrak PA et al. (2025). Effect of different wavelengths and powers of laser on surface topography and biofilm removal from titanium implants: an in vitro study. *BMC Oral Health*. https://doi.org/10.1186/s12903-025-07212-7 · in vitro
51. Matys J et al. (2019). Temperature Changes and SEM Effects of Three Different Implants-Abutment Connection during Debridement with Er:YAG Laser: An Ex Vivo Study. *Materials (Basel)*. https://doi.org/10.3390/ma12223748 · in vitro
52. Yao WL et al. (2020). Er,Cr:YSGG Laser Performance Improves Biological Response on Titanium Surfaces. *Materials (Basel)*. https://doi.org/10.3390/ma13030756 · in vitro
53. Assery N et al. (2023). The effect of Er:YAG laser treatment on biofilm formation on titanium and zirconia disc surfaces. *J Periodontol*. https://doi.org/10.1002/JPER.22-0243 · in vitro
54. Kreisler M et al. (2002). Temperature changes at the implant-bone interface during simulated surface decontamination with an Er:YAG laser. *Int J Prosthodont*. https://pubmed.ncbi.nlm.nih.gov/12475166/ · animal study
55. Monzavi A et al. (2014). Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems. *J Dent (Tehran)*. https://pubmed.ncbi.nlm.nih.gov/24910697/ · animal study
56. Ulu M et al. (2018). Antibiofilm efficacies of cold plasma and er: YAG laser on Staphylococcus aureus biofilm on titanium for nonsurgical treatment of peri-implantitis. *Niger J Clin Pract*. https://doi.org/10.4103/njcp.njcp_261_17 · in vitro
57. Geminiani A et al. (2012). Temperature change during non-contact diode laser irradiation of implant surfaces. *Lasers Med Sci*. https://doi.org/10.1007/s10103-010-0876-8 · in vitro
58. Sarac Atagun O et al. (2025). Effects of diode laser parameters on thermal response of RBM, SLA, and additively manufactured titanium surfaces. *Lasers Med Sci*. https://doi.org/10.1007/s10103-025-04759-3 · in vitro
59. Matys J et al. (2016). Thermodynamic effects after Diode and Er:YAG laser irradiation of grade IV and V titanium implants placed in bone - an ex vivo study. Preliminary report. *Biomed Tech (Berl)*. https://doi.org/10.1515/bmt-2015-0135 · in vitro
60. AlMoharib HS et al. (2021). Efficacy of an Er:YAG laser in the decontamination of dental implant surfaces: An in vitro study. *J Periodontol*. https://doi.org/10.1002/JPER.20-0765 · RCT
61. Yurdakul B et al. (2026). Mechanical Versus Laser Debridement of SLA Titanium Implants: An In Vitro Morphological and Elemental Analysis of Debris Removal and Surface Preservation. *Nanomaterials (Basel)*. https://doi.org/10.3390/nano16120703 · in vitro
62. Eick S et al. (2017). In Vitro-Activity of Er:YAG Laser in Comparison with other Treatment Modalities on Biofilm Ablation from Implant and Tooth Surfaces. *PLoS One*. https://doi.org/10.1371/journal.pone.0171086 · in vitro
63. Shiba T et al. (2024). Effect of Er,Cr:YSGG Laser Irradiation on the Surface Modification and Cell Adhesion on Titanium Discs: An In Vitro Study. *Materials (Basel)*. https://doi.org/10.3390/ma17194899 · in vitro
64. Chellini F et al. (2017). Mesenchymal stromal cell and osteoblast responses to oxidized titanium surfaces pre-treated with λ = 808 nm GaAlAs diode laser or chlorhexidine: in vitro study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-017-2243-5 · in vitro
65. Ayubianmarkazi N et al. (2015). An in vitro evaluation of the responses of human osteoblast-like SaOs-2 cells on SLA titanium surfaces irradiated by different powers of CO2 lasers. *Lasers Med Sci*. https://doi.org/10.1007/s10103-015-1756-z · in vitro
66. Hashim A et al. (2026). Influence of peri-implantitis defect angles on morphology and the biocompatibility of the implant surfaces after Er, Cr: YSGG laser therapy: an ex vivo study. *BMC Oral Health*. https://doi.org/10.1186/s12903-026-09278-3 · clinical study
67. Jin SH et al. (2019). Decontamination methods to restore the biocompatibility of contaminated titanium surfaces. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2019.49.3.193 · in vitro
68. Mailoa J et al. (2014). Clinical outcomes of using lasers for peri-implantitis surface detoxification: a systematic review and meta-analysis. *J Periodontol*. https://doi.org/10.1902/jop.2014.130620 · systematic review
69. Nengwen Huang et al. (2024). The clinical efficacy of laser in the nonsurgical treatment of peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-024-00570-x · systematic review
70. Amit Kumar et al. (2026). Efficacy of Diode Lasers in Non-surgical Management of Peri-Implantitis: A Systematic Review and Meta-analysis *Asian Journal of Oral Health and Allied Sciences*. https://doi.org/10.18231/j.ajohas.32321.1791449240 · systematic review
71. Momen A. Atieh et al. (2022). Diode Laser as an Adjunctive Treatment for Peri-implant Mucositis: A Systematic Review and Meta-analysis *International Dental Journal*. https://doi.org/10.1016/j.identj.2022.06.026 · systematic review
72. Noelken R et al. (2020). A modified surgical approach for hard and soft tissue reconstruction of severe periimplantitis defects: laser-assisted periimplant defect regeneration (LAPIDER). *Int J Implant Dent*. https://doi.org/10.1186/s40729-020-00218-6 · clinical study
73. Schwarz F et al. (2013). Four-year follow-up of combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12143 · RCT
74. Schwarz F et al. (2017). Combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination: a 7-year follow-up observation. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12648 · RCT
75. Baima G et al. (2022). Surface decontamination protocols for surgical treatment of peri-implantitis: A systematic review with meta-analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13992 · systematic review
76. Lei Li et al. (2023). Efficacy of Er:YAG Laser as a Debridement Method in Surgical Treatment for Peri-Implantitis: A Systematic Review. *PubMed Central*. https://doi.org/10.3290/j.ohpd.b3818041 · systematic review
77. Philip Leander Keeve et al. (2018). Surgical Treatment of Periimplantitis With Non–Augmentative Techniques *Implant Dentistry*. https://doi.org/10.1097/id.0000000000000838 · clinical study
78. Takasaki AA et al. (2007). Er:YAG laser therapy for peri-implant infection: a histological study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-006-0430-x · animal study
79. Persson LG et al. (2004). Carbon dioxide laser and hydrogen peroxide conditioning in the treatment of periimplantitis: an experimental study in the dog. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/j.1708-8208.2004.tb00039.x · in vitro
80. Patil S et al. (2023). Efficacy of laser in re-osseointegration of dental implants-a systematic review. *Lasers Med Sci*. https://doi.org/10.1007/s10103-023-03860-9 · systematic review
81. Marianna Chala et al. (2020). Adjunctive Use of Lasers in Peri-Implant Mucositis and Peri-Implantitis Treatment: A Systematic Review *Dentistry Journal*. https://doi.org/10.3390/dj8030068 · systematic review
82. Miriam Ting et al. (2022). Laser Treatment of Peri-Implantitis: A Systematic Review of Radiographic Outcomes *Dentistry Journal*. https://doi.org/10.3390/dj10020020 · systematic review
83. Zhe Wang et al. (2026). Comparative effectiveness of novel laser-assisted technologies for treating peri-implantitis: A network meta-analysis of randomized controlled trials *Medicine*. https://doi.org/10.1097/md.0000000000051256 · systematic review
84. Neophytou C et al. (2026). Microbiological Effects of Laser-Assisted Non-Surgical Treatment of Peri-Implantitis: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. *Dent J (Basel)*. https://doi.org/10.3390/dj14010049 · systematic review
85. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
86. Amna Mohamed Abdulla AlMarzooqi et al. (2023). Treatment of Peri-implant Diseases using Lasers: A Systematic Review *The Open Dentistry Journal*. https://doi.org/10.2174/18742106-v17-e230517-2022-143 · systematic review
87. Glaucia Valias Filgueiras et al. (2026). Laser Therapy in the Prevention and Treatment of Peri-Implantitis: A Critical Integrative Review *Revista Multidisciplinar do Nordeste Mineiro*. https://doi.org/10.66104/e25tcs21 · review
88. \*Dr. Shrirup Jogdand, Dr. Roshani Thakur, Dr. Motilal Jangid, Dr. Sakshi Jaiswal, Dr. Vaishnavi Dighe, Dr.Kalpana Jangid (2026). LASERS IN THE MANAGEMENT AND PREVENTION OF PERI-IMPLANTITIS: A NARRATIVE REVIEW OF CURRENT EVIDENCE AND FUTURE DIRECTIONS *Zenodo (CERN European Organization for Nuclear Research)*. https://doi.org/10.5281/zenodo.21021706 · review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

25 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Irrespective of the adjunctive treatment modality, achievement of peri-implantitis therapeutic endpoint was limited across groups. Possible associations with treatment outcomes were observed; these findings require confirmation in larger studies.” — [Clementini M et al. 2026](https://doi.org/10.1111/clr.70153), Clin Oral Implants Res; cited 2.
- “SOP positivity (12.5% vs. 6.58%, P = 0.191) and implant survival (98.08% vs. 100%, P = 0.509) did not differ significantly between groups. Conclusion Adjunctive ECL therapy may improve clinical parameters, reduced bacterial load, and slowed marginal bone loss compared to MD alone in patients with peri-implantitis at 6-month follow-up, but further prospective studies are necessary to validate these findings and …” — [Jiaojie Li et al. 2026](https://doi.org/10.1016/j.jrras.2026.102723), Journal of Radiation Research and Applied Sciences; cited 0.
- “The study concluded that Mechanical debridement combined with photodynamic therapy (MD + PDT) improves peri-implant health and reduces inflammation significantly better than mechanical debridement alone.” — [Pallavi Goswami 2026](https://doi.org/10.5281/zenodo.23053610), Journal of chemical health risks; cited 0.
- “Surgical approaches for management of peri-implantitis demonstrated significant benefits over laser therapy in terms of treatment success and PD reduction. Nevertheless, diode laser therapy, as described in this study, could represent a minimally invasive alternative for treatment of non-advanced peri-implantitis defects.” — [Dena Hashim et al. 2025](https://doi.org/10.1007/s00784-025-06204-9), Clinical Oral Investigations; cited 12.
- “Within the limitations of this feasibility study, the present data concluded that plasma spray and Erbium: YAG laser can be used for abutment surface treatment to achieve better peri-implant soft tissue healing.” — [Yossri D et al. 2025](https://doi.org/10.1111/cid.13373), Clin Implant Dent Relat Res; cited 7.
- “Treatment of peri-implant mucositis was effective regardless of whether the treatment was performed with an Er:YAG laser or an ultrasonic scaler. Fewer diseased sites were diagnosed at six months following laser treatment. TRIAL REGISTRATION: Registered at www. CLINICALTRIALS: gov : study no, NCT05772299.” — [Viveca Wallin Bengtsson et al. 2025](https://doi.org/10.1186/s40729-025-00591-0), International Journal of Implant Dentistry; cited 6.
- “Er:YAG laser therapy, particularly at higher energy levels (80 mJ), enhances clinical outcomes in peri-implantitis treatment by effectively reducing plaque biofilm, inflammation, and pain. These findings underscore the importance of optimizing laser energy parameters for improved peri-implantitis management.” — [Xiaoying Dai et al. 2025](https://doi.org/10.1097/md.0000000000044061), Medicine; cited 5.
- “Clinical parameters were measured before and after treatment at baseline, 1 month, 3 months and 6 months. Both DLAD and PDT are effective in treating peri-implant mucositis around platform-switch implants, with no significant difference in clinical outcomes.” — [Randhir Kumar et al. 2025](https://doi.org/10.6026/973206300211103), Bioinformation; cited 1.
- “The proportion of patients with improved clinical outcomes was similar between the 2 treatment groups, albeit surgical treatment yielded greater pocket reduction. No differences were found in immunological or microbial outcomes.” — [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683), J Periodontol.
- “Diode laser seems to be a reliable tool as an adjunct for supporting the nonsurgical mechanical treatment during the early stages of peri-implantitis. Furthermore, the findings suggest that IL-17, sclerostin and IL-1β may serve as promising biomarkers for assessing efficacy of peri-implantitis treatment.” — [Nazan Ece Erduran et al. 2024](https://doi.org/10.1007/s00784-024-05855-4), Clinical Oral Investigations; cited 10.

15 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

40 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Diode laser along with the nonsurgical management of peri-implantitis demonstrated no advantage compared to non-surgical treatment alone. Long term researches with considerable sample size will only enable us to appropriately assess this treatment modality.” — [Amit Kumar et al. 2026](https://doi.org/10.18231/j.ajohas.32321.1791449240), Asian Journal of Oral Health and Allied Sciences; cited 0.
- “Despite some positive findings, overall success rates for nonsurgical methods remain variable, highlighting the need for standardized treatment protocols and further research to individualize treatment.” — [Giovanni Battista Menchini-Fabris et al. 2026](https://doi.org/10.1016/j.jdip.2026.100004), Journal of Dental Implants and Prosthodontics; cited 0.
- “PDT exerted the most stable short-term efficacy for peri-implantitis. DL and Er:YAG had limited valid benefits. Due to insufficient long-term data, the sustained effects of these treatments and their roles in preventing lesion recurrence and maintaining implant survival are still undetermined.” — [Zhe Wang et al. 2026](https://doi.org/10.1097/md.0000000000051256), Medicine; cited 0.
- “High heterogeneity, diagnostic variability, and the low number of included studies increase the need of well-designed RCTs on the topic. Despite no conclusive evidence could be found, adjunctive aPDT showed a promising trend to improve MD results.” — [Nastri L et al. 2025](https://doi.org/10.3390/dj13120567), Dent J (Basel); cited 4.
- “This approach shows promise in reducing inflammation and promoting healing. Nonetheless, further high-quality research is necessary to confirm long-term benefits and establish clear clinical guidelines for its use.” — [Narjiss Akerzoul et al. 2025](https://doi.org/10.2174/0118742106400224250724113341), The Open Dentistry Journal; cited 3.
- “Both PDT and laser therapy are effective in reducing the microbial load. Additionally, laser causes the least surface alterations, with some studies reporting minor improvements in implant surface properties.” — [Maedeh Masoumzadeh et al. 2025](https://doi.org/10.18502/fid.v22i49.20330), Frontiers in Dentistry; cited 0.

32 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

34 non-randomised clinical studies and 18 case reports or series.

- “Er, Cr: YSGG laser therapy in the decontamination procedure of previously contaminated implants in peri-implantitis therapy is successful in preserving the implant surface integrity in diverse peri-implantitis defects without major surface roughness alterations; it shows favorable biocompatibility with an appropriate osteogenic response in the four studied groups.” — [Hashim A et al. 2026](https://doi.org/10.1186/s12903-026-09278-3), BMC Oral Health; cited 1.
- “The combined use of mechanical debridement and a diode laser in the treatment of peri-implantitis is more effective at reducing clinical signs of inflammation than either method used alone. However, the lack of correlation between S100A8 levels and clinical improvement suggests that this biomarker may not be sensitive in short-term follow-up of treatment.” — [Akif Nalbant et al. 2026](https://doi.org/10.1007/s10103-026-04925-1), Lasers in Medical Science; cited 0.
- “The adjunctive use of the Er,Cr:YSGG laser significantly enhanced clinical outcomes and reduced inflammatory markers in peri-implantitis treatment. This approach holds promise as an effective adjunctive therapy in clinical practice.” — [Arvina Rajasekar et al. 2026](https://doi.org/10.32782/2226-2008-2026-2-4), ; cited 0.
- “The 970 nm diode laser at 1 W provides effective bactericidal action with minimal implant surface damage and can be recommended for clinical use in peri-implantitis treatment. The Nd:YAG laser at equivalent parameters is not recommended due to significant structural surface damage.” — [Ekaterina Yu. Diachkova et al. 2026](https://doi.org/10.65324/dtp007), Dentistry Theory and Practice; cited 0.
- “Purpose This pilot randomized controlled clinical trial evaluated the potential clinical benefits of adjunctive erbium-doped yttrium aluminum garnet (Er:YAG) laser therapy combined with mechanical and chemical implant surface decontamination. Specifically, it assessed 1-year clinical and radiographic outcomes after regenerative treatment for peri-implantitis with infrabony defects.” — [Hae-Won Park et al. 2026](https://doi.org/10.5051/jpis.2600540027), Journal of Periodontal & Implant Science; cited 0.
- “Er:YAG laser therapy appears to be effective in reducing probing depth and improving clinical parameters in the management of peri-implantitis, particularly when used as an adjunct to surgical regenerative therapy. Further studies with larger sample sizes and standardized protocols are necessary to confirm its efficacy for oral bacterial decontamination.” — [Salma Adnane et al. 2026](https://doi.org/10.5281/zenodo.21870265), Zenodo (CERN European Organization for Nuclear Research); cited 0.

28 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

102 in vitro / ex vivo and 11 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “To determine the changes induced by the laser, the following techniques were used: X-ray diffraction (XRD), Rietveld refinement method, scanning electron microscopy (SEM) with EDS (Energy-dispersive X-ray Spectroscopy), and thermography. The results show that the proposed Ti6Al4V and Ti6Al7Nb scaffolds can be exposed to an Er3+:YAG laser without damage when the power is limited to 0.5 W.” — [Sobierajska P et al. 2026](https://doi.org/10.3390/ma19040775), Materials (Basel); cited 2.
- “Ti ions and particles were found after instrumentation using SS curettes, Ti curettes, and CV ultrasonic inserts, which may affect the disease etiology and outcomes of peri-implantitis therapy more prominently compared to irradiation methods such as CS ultrasonic inserts, CO2 lasers, or ECY lasers.” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375), Int J Oral Maxillofac Implants; cited 1.
- “Er:YAG best preserved SLA microtopography but exhibited a lower debridement efficacy (3.27 ± 0.83) than mechanical methods. No method resulted in a pristine surface.” — [Yurdakul B et al. 2026](https://doi.org/10.3390/nano16120703), Nanomaterials (Basel); cited 1.
- “All active protocols reduced viable Staphylococcus aureus counts compared with untreated implants. Within the limitations of this single-species in vitro model, Er,Cr:YSGG laser irradiation achieved the greatest reduction, whereas GalvoSurge and CHX resulted in moderate and comparable decreases.” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294), Cureus; cited 0.
- “Laser treatment did not result in significant changes in implant surface roughness, suggesting its safety for use in surface decontamination without compromising implant integrity. This technology may represent a safer, more effective approach to implant surface decontamination than traditional methods.” — [Thuy Vo et al. 2026](https://doi.org/10.3934/bioeng.2026013), AIMS bioengineering; cited 0.
- “Laser plus ICG-loaded CNPs and CHX had comparably the highest decontamination efficacy. This study demonstrated that aPDT with ICG-loaded CNPs significantly reduced the A. actinomycetemcomitans colony count on dental implants, showing comparable efficacy to CHX.” — [Sayar F et al. 2025](https://doi.org/10.1038/s41598-025-15871-3), Sci Rep; cited 9.

96 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “The results suggest that PDT and OFD have significant benefits in peri-implantitis treatment by reducing bacterial count. The presence of bacterial complex with different response to therapeutic modality suggests the use of combined decontamination methods for peri-implantitis treatment.” — [Madi M et al. 2018](https://doi.org/10.1155/2018/7570105), Biomed Res Int; cited 28.
- “Within the limits of the study, the combination of mechanical and chemical treatment proved to be the most effective treatment for disinfection of the anodized implant surface.” — [Htet M et al. 2016](https://doi.org/10.1902/jop.2016.150615), J Periodontol; cited 56.
- “Based on the results, no thermal damage was observed during implant surface decontamination by Er:YAG laser with and without refrigeration. Thus, Er:YAG laser irradiation can be a safe method for treatment of periimplantitis.” — [Monzavi A et al. 2014](https://pubmed.ncbi.nlm.nih.gov/24910697/), J Dent (Tehran).
- “Group aPDT showed more favorable results in parameter area of reactive tissue than the other methods after day 7, but over longer time periods all methods produced outcomes equivalent to sterile implants.” — [Salmeron S et al. 2013](https://doi.org/10.1902/jop.2012.120166), J Periodontol; cited 130.

7 further animal study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Parameters as stated in the abstracts

- “These alloys, commonly used in implantology, here in the form of Ti block scaffolds, have been exposed to an Er3+:YAG laser under various parameters (energy range of 50-320 mJ, exposure times of 20 or 30 s), and their effects have been further observed.” — [Sobierajska P et al. 2026](https://doi.org/10.3390/ma19040775) (in vitro).
- “For the laser groups, a CO2 laser (no contact, defocused beam, continuous wave, 2-W power) and an ECY laser tip were used (in contact with the implant; power of 2 W; 75 Hz; 40% water: 2% air).” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375) (in vitro).
- “Implants were randomly assigned to four groups (n = 12/group): untreated control, CHX immersion for 60 s, GalvoSurge electrolytic cleaning for 120 s, or Er,Cr:YSGG laser treatment (2780 nm; 2.5 W; 30 Hz; 70% water; 60% air; 30 s).” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294) (in vitro).
- “An in vitro experimental study was conducted using scanning electron microscopy (SEM) of dental implant surfaces (Straumann, Astra Tech, Osstem, Alpha Bio) following exposure to a diode laser «LSP-IRE-Polyus» (970 nm) and a Nd:YAG laser at power settings of 1 W and 2 W.” — [Ekaterina Yu. Diachkova et al. 2026](https://doi.org/10.65324/dtp007) (clinical study).
- “The control group received mechanical debridement with a sham laser, while the test group received mechanical debridement followed by aPDT (Toluidine or Methylene Blue photosensitizer incubated for 1–3 minutes and irradiated with a 660/680 nm diode laser for 60–120 seconds).” — [Pallavi Goswami 2026](https://doi.org/10.5281/zenodo.23053610) (RCT).
- “The 2.5 W settings proved most effective in decontamination, although none of the laser settings completely eradicated the bacteria.” — [Thuy Vo et al. 2026](https://doi.org/10.3934/bioeng.2026013) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Waterlase** — 6 entries
- **Air-Flow** — 6 entries
- **LightWalker** — 3 entries
- **Piezon** — 3 entries
- **GalvoSurge** — 2 entries
- **Cavitron** — 2 entries
- **TiBrush** — 2 entries
- **Perisolv** — 2 entries
- **Perio-Flow** — 1 entry
- **Ti-Brush** — 1 entry
- **i-Brush** — 1 entry
- **Vector** — 1 entry

Manufacturers: Straumann (16), Biolase (11), EMS (7), Fotona (7), Geistlich (6), Dentsply Sirona (5), Hu-Friedy (5), Nobel Biocare (4), Dentsply (4), Sirona (4), Astra Tech (3), Zimmer Biomet (3), Zimmer (3), Dentium (3), Osstem (2), KaVo (2), BioHorizons (2), Camlog (2), Acteon (1), NSK (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (20 different): chlorhexidine (47), saline (41), photosensitizer dye (28), hydrogen peroxide (22), antibiotics (systemic) (18), amoxicillin (15), sterile water (13), citric acid (10), sodium hypochlorite (7), metronidazole (6), tetracycline (6), minocycline (5), doxycycline (4), EDTA (3), povidone-iodine (3), ozone (2), phosphoric acid / etching gel (2), Perisolv (2), chloramine (1), enamel matrix derivative (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (283)

The 283 entries of this chapter are too many for this page to stay readable in one request; they are listed in the [table of all entries, filtered on this method](https://www.nitibrush.com/articles/literature-index/all-entries/#method=laser), and in the CSV/JSON data.


## Related chapters

- [6. Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/)
- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- Next: [6. Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/)


---

# 6. Antimicrobial photodynamic therapy

Chapter 6 of an evidence-based reader on implant surface decontamination in peri-implantitis: 146 entries on antimicrobial photodynamic therapy — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about antimicrobial photodynamic therapy (aPDT) in peri-implantitis?

**Key facts — Antimicrobial photodynamic therapy**

- Entries in this chapter: 146 of 819 (2003–2026): RCT 12 · clinical study 13 · case report/series 10 · systematic review 34 · review 33 · in vitro 30 · animal study 5 · not classified 9
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Aoki A et al. 2015](https://doi.org/10.1111/prd.12080) (457); [Bassetti M et al. 2014](https://doi.org/10.1111/clr.12155) (312)
- Products named by the authors: Air-Flow (2), Perio-Flow (1), TiBrush (1), Emdogain (1), Perisolv (1), Cavitron (1), Vector (1)
- Manufacturers named by the authors: Geistlich (3), Hu-Friedy (3), EMS (2), Dentsply Sirona (2), Dentsply (2), Sirona (2), Straumann (2), Fotona (1), KaVo (1), Dentium (1)
- Chemical agents used alongside: chlorhexidine (37), photosensitizer dye (31), saline (25), hydrogen peroxide (17), antibiotics (systemic) (15), citric acid (9), minocycline (7), amoxicillin (7)
- Often studied together with: [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (77), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (38), [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (28), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (24)


## What it is

A photosensitiser dye (methylene blue, toluidine blue, indocyanine green, phenothiazine chloride and others are reported) is applied to the implant surface or pocket and then activated by light of a matching wavelength, producing reactive oxygen species that act on the biofilm. In the clinical studies it is nearly always an adjunct to mechanical debridement rather than the sole measure.


### Mechanism and use, as the papers describe it

The publications in this chapter describe antimicrobial photodynamic therapy as a photosensitiser activated by light of a matching wavelength to produce reactive oxygen species that act on micro-organisms, delivered with a low-power laser or light-emitting diode.[1,2] The photosensitisers named are toluidine blue O, methylene blue, indocyanine green, phenothiazine chloride, rose bengal, riboflavin, curcumin, 5-aminolevulinic acid, phycocyanin and hydroxyaluminium phthalocyanine, with experimental carriers such as indocyanine green loaded chitosan nanoparticles.[3,4,5,6,7,8,9,10,11,12,13] Light sources are diode lasers between 630 nm and 810 nm in the clinical trials, red lasers for the blue dyes and 805 nm to 830 nm lasers for indocyanine green, LEDs at 630 nm, 405 nm or 390 nm to 480 nm, and a 445 nm diode for riboflavin or curcumin.[14,15,16,17,9,18,8,19] A related protocol termed oxygen high-level laser therapy combines a high-power diode laser with hydrogen peroxide rather than a dye.[20,21]

Application is described as placing the dye in the peri-implant sulcus or on the exposed surface, allowing an incubation period, irradiating and rinsing, with one surgical series removing dye remnants with glycine powder and one case report washing the dye away with saline before grafting.[22,23,15,24] In the non-surgical trials the dye and light follow mechanical debridement with curettes, ultrasonic devices or air-polishing, for mucositis and for initial or established peri-implantitis.[25,26,22,27] In the surgical entries the surface is irradiated after flap elevation and granulation tissue removal, before guided bone regeneration or alongside implantoplasty, and some protocols repeat treatment at sites with residual bleeding at 3, 6, 9 and 12 months.[28,3,29,26]


### Reported operating conditions

Toluidine blue O is reported at 100 µg/ml with a 635 nm diode at 220 mW, at 0.1 mg/ml with a 635 nm laser or 630 nm LED, at 0.01 per cent for 1 minute with a red laser, and with 690 nm light in a surgical series.[30,17,31,15] Methylene blue is reported after 5 minutes of contact with a 660 nm, 30 mW laser for 3 or 5 minutes, at 200 µg/ml to 400 µg/ml with a 660 nm, 80 mW diode for 1 minute (4.8 J/cm2), and at 0.1 per cent with a 635 nm diode for 1 or 5 minutes or a 660 nm diode at 200 mW through a 320 µm tip.[4,32,18,8] Indocyanine green is reported with an 805 nm laser clinically, with an 808 nm diode at 250 mW, and at 0.25 mg/ml for 5 minutes followed by 808 nm irradiation for 60 s.[5,30,13]

Clinical protocols state 630 nm light at 2,000 mW/cm2 for 120 s, toluidine or methylene blue incubated for 1 to 3 minutes and irradiated at 660 nm or 680 nm for 60 s to 120 s, and a 5 per cent 5-aminolevulinic acid gel.[22,23,10] Other dyes are reported as 0.1 per cent riboflavin with a 445 nm diode at 200 mW and 100 Hz, 0.5 per cent riboflavin or 5 mg/ml curcumin with a 390 nm to 480 nm LED, and 125 µg/ml phycocyanin with a 635 nm diode for 4 minutes.[8,9,11]


### Effects on the implant surface reported in laboratory studies

Scanning electron microscopy and energy-dispersive spectroscopy showed no alteration of sandblasted, large-grit, acid-etched implants after photodynamic therapy with toluidine blue and a 630 nm LED or indocyanine green and an 810 nm diode, although sodium chloride from the rinsing liquid could leave an adhesive layer.[33] Surface roughness was unchanged and the contact angle decreased after photodynamic therapy of contaminated titanium blocks, surface hardness did not differ in a phthalocyanine study, and one comparison described minimal alteration with photodynamic therapy against melting after Er:YAG irradiation.[34,12,35] Other authors reported that mean roughness of commercial implants differed from controls after photodynamic or chemical decontamination, and that surface chemistry and topography were altered after titanium brush with photodynamic therapy while no treatment hindered biocompatibility.[36,37]

Reductions in viable bacteria of up to 99 per cent after 5 minutes of methylene blue treatment, with a 42 per cent reduction in lipopolysaccharide bioactivity and no damage of the microstructure, were reported on moderately rough titanium.[18] Methylene blue photodynamic therapy was reported as comparable to chlorhexidine and more effective than light without dye in one study, as less effective than 0.2 per cent chlorhexidine in another, and as leaving the highest colony count among cold plasma, phosphoric acid and photodynamic groups in a third, in which no method completely cleaned the micro-textured surface.[4,17,38] Combining chlorhexidine or hydrogen peroxide with photodynamic therapy produced greater reductions of Staphylococcus aureus than either alone, dyes without light activation had no antimicrobial effect in one protocol, and on titanium Er:YAG irradiation removed more biofilm than photodynamic therapy.[39,31,40] Osteoblast-like cells on surfaces disinfected with 400 µg/ml methylene blue expressed functions comparable to uncontaminated controls, and in a rat model photodynamically treated discs showed the smallest reactive tissue area at day 7 with all groups resembling sterile discs after day 28.[32,41]


### Position in treatment protocols

Across the clinical entries photodynamic therapy is an adjunct to mechanical debridement rather than the sole measure, and the comparators are debridement alone, locally delivered minocycline, diode laser irradiation, chlorhexidine or surgery.[42,25,43,28,2] Schär et al. and Bassetti et al. reported that adjunctive photodynamic therapy and minocycline microspheres reduced mucosal inflammation to a similar extent at 6 and 12 months in initial peri-implantitis, without routine complete resolution.[25,26] A 2018 American Academy of Periodontology review concluded that photodynamic therapy may provide similar improvements in probing depth and attachment level to conventional therapy, and a 2025 meta-analysis reported probing depth reductions of 0.86 mm at 3 months and 0.83 mm at 6 months for non-surgical debridement with photodynamic therapy and 0.56 mm for surgical debridement with photodynamic therapy.[42,44] Network meta-analyses reported the highest ranking probability for photodynamic therapy with debridement for probing depth, bone level and attachment changes, and significant improvements in probing depth, plaque and crestal bone loss but not bleeding on probing or attachment level.[45,46] Other meta-analyses reported a higher marginal bone level change with no 6-month probing depth difference, short-term gains that did not persist at extended follow-up, and benefits for bleeding and crestal bone loss in patients with type 2 diabetes.[47,48,14]

In surgical treatment a 2023 meta-analysis found a small reduction in bleeding on probing with adjunctive photodynamic therapy in two trials, and a 2023 network meta-analysis found that adding photodynamic therapy did not significantly change probing depth reduction or attachment gain after augmentative therapy.[49,50] A prospective cohort reported lower probing depths with photodynamic therapy added to implantoplasty and guided bone regeneration, without differences in infection resolution, bone level or bleeding over 18 months.[29] A Cochrane review stated that the certainty of the evidence for adjunctive photodynamic therapy is very low and that any improvements may be too small to be clinically important.[51]


### Limitations and open questions as stated by the authors

Authors describe high heterogeneity in dye, light and debridement protocols and in diagnostic criteria, a low number of included trials, and certainty of evidence rated low to moderate or very low.[47,44,51,52] The choice of photosensitiser is reported to influence the outcome, with one meta-analysis associating toluidine blue with the largest improvements and another concluding that selection must consider the patient and the lesion.[53,54] Long-term data are described as insufficient, with no additional changes over extended follow-up, gradual recurrence of clinical signs over 18 months and no routine complete resolution of inflammation.[46,48,29,25] Laboratory authors note that complete biofilm eradication was rarely achieved, that light penetration into biofilm is limited and that clinical efficacy of in vitro protocols remains to be investigated, and future studies are asked to report disease entities and surgical settings separately with direct measures of re-osseointegration.[55,56,18,57]


### Sources cited in this description (57)

1. Harish Kumar VV (2025). Peri-implant Diseases: Enhanced Antibacterial Photodynamic Therapy **. https://doi.org/10.67091/jrdc.2025.8115 · clinical study
2. Bombeccari GP et al. (2013). Photodynamic therapy to treat periimplantitis. *Implant Dent*. https://doi.org/10.1097/01.id.0000433592.18679.91 · RCT
3. Shibli JA et al. (2003). Treatment of ligature-induced peri-implantitis by lethal photosensitization and guided bone regeneration: a preliminary histologic study in dogs. *J Periodontol*. https://doi.org/10.1902/jop.2003.74.3.338 · animal study
4. Marotti J et al. (2013). Decontamination of dental implant surfaces by means of photodynamic therapy. *Lasers Med Sci*. https://doi.org/10.1007/s10103-012-1148-6 · in vitro
5. Reza Pourabbas et al. (2023). Effect of photodynamic therapy as an adjunctive to mechanical debridement on the nonsurgical treatment of peri-implant mucositis: A randomized controlled clinical trial *Dental Research Journal*. https://doi.org/10.4103/1735-3327.367900 · RCT
6. Umberto Romeo et al. (2016). The Antimicrobial Photodynamic Therapy in the Treatment of Peri-Implantitis *International Journal of Dentistry*. https://doi.org/10.1155/2016/7692387 · RCT
7. Nedumaran N et al. (2025). Impact of rose bengal-mediated antimicrobial photodynamic therapy adjunctive to mechanical debridement on clinical, microbiological, and immunological parameters in peri-implantitis: a parallel, single-blinded, randomized controlled trial. *Lasers Med Sci*. https://doi.org/10.1007/s10103-025-04548-y · RCT
8. Morelato L et al. (2022). A Novel Technique for Disinfection Treatment of Contaminated Dental Implant Surface Using 0.1% Riboflavin and 445 nm Diode Laser-An In Vitro Study. *Bioengineering (Basel)*. https://doi.org/10.3390/bioengineering9070308 · in vitro
9. Etemadi A et al. (2023). Evaluation of the effect of photodynamic therapy with Curcumin and Riboflavin on implant surface contaminated with Aggregatibacter actinomycetemcomitans. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2023.103833 · in vitro
10. Roberto Rossi et al. (2022). Photodynamic Therapy by Mean of 5-Aminolevulinic Acid for the Management of Periodontitis and Peri-Implantitis: A Retrospective Analysis of 20 Patients *Antibiotics*. https://doi.org/10.3390/antibiotics11091267 · clinical study
11. Etemadi A et al. (2022). In Vitro Efficacy of Antimicrobial Photodynamic Therapy With Phycocyanin and Diode Laser for the Reduction of Porphyromonas gingivalis. *J Lasers Med Sci*. https://doi.org/10.34172/jlms.2022.55 · in vitro
12. Shramika Yelturi et al. (2023). Efficacy of phthalocyanine dye in antimicrobial debridement by photodynamic therapy as an adjunct to mechanical management of peri-implantitis: an in vitro study *Journal of the International Academy of Periodontology*. https://doi.org/10.14436/1466-2094.25.4.219-227.oar · in vitro
13. Sayar F et al. (2025). Efficacy of antimicrobial photodynamic therapy with chitosan nanoparticles for decontamination of dental implants contaminated with Aggregatibacter actinomycetemcomitans. *Sci Rep*. https://doi.org/10.1038/s41598-025-15871-3 · in vitro
14. Shima Afrasiabi et al. (2023). Evaluating the effect of mechanical debridement with adjunctive antimicrobial photodynamic therapy in comparison with mechanical debridement alone on the peri-implant parameters in type 2 diabetic mellitus patients with peri-implantitis: a systematic review and meta-analysis *BMC Oral Health*. https://doi.org/10.1186/s12903-023-03337-9 · systematic review
15. Önder Solakoğlu et al. (2018). Regenerative Therapy of Peri-Implantitis: Clinical and Radiologic Documentation of 16 Consecutive Patients With a Mean Follow-Up of 3 Years *Journal of Oral Implantology*. https://doi.org/10.1563/aaid-joi-d-18-00168 · clinical study
16. Madi M et al. (2018). The Effect of Different Implant Surfaces and Photodynamic Therapy on Periodontopathic Bacteria Using TaqMan PCR Assay following Peri-Implantitis Treatment in Dog Model. *Biomed Res Int*. https://doi.org/10.1155/2018/7570105 · animal study
17. Ghasemi M et al. (2019). Antimicrobial efficacy of photodynamic therapy using two different light sources on the titanium-adherent biofilms of Aggregatibacter actinomycetemcomitans: An in vitro study. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2019.03.004 · in vitro
18. Giannelli M et al. (2017). Effects of photodynamic laser and violet-blue led irradiation on Staphylococcus aureus biofilm and Escherichia coli lipopolysaccharide attached to moderately rough titanium surface: in vitro study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-017-2185-y · in vitro
19. Wenzler JS et al. (2024). Bactericidal Effect of Different Photochemical-Based Therapy Options on Implant Surfaces-An In Vitro Study. *J Clin Med*. https://doi.org/10.3390/jcm13144212 · in vitro
20. Caccianiga G et al. (2016). Clinical, Radiographic and Microbiological Evaluation of High Level Laser Therapy, a New Photodynamic Therapy Protocol, in Peri-Implantitis Treatment; a Pilot Experience. *Biomed Res Int*. https://doi.org/10.1155/2016/6321906 · clinical study
21. Gianluigi Caccianiga et al. (2021). Peri-Implantitis Management: Surgical versus Non-Surgical Approach Using Photodynamic Therapy Combined with Hydrogen Peroxide (OHLLT—Oxygen High Level Laser Therapy): A Retrospective Controlled Study *Applied Sciences*. https://doi.org/10.3390/app11115073 · clinical study
22. Mohammad Reza Karimi et al. (2016). Efficacy of Antimicrobial Photodynamic Therapy as an Adjunctive to Mechanical Debridement in the Treatment of Peri-implant Diseases: A Randomized Controlled Clinical Trial *Journal of lasers in medical sciences*. https://doi.org/10.15171/jlms.2016.24 · RCT
23. Pallavi Goswami (2026). Efficacy of Photodynamic Therapy as an Adjunct to Non-Surgical Debridement in the Treatment of Peri-Implant Mucositis: An Original Research Study *Journal of chemical health risks*. https://doi.org/10.5281/zenodo.23053610 · RCT
24. Garcia de Carvalho G et al. (2020). Antimicrobial photodynamic therapy associated with bone regeneration for peri-implantitis treatment: A case report. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2020.101705 · case report/series
25. Schär D et al. (2013). Anti-infective therapy of peri-implantitis with adjunctive local drug delivery or photodynamic therapy: six-month outcomes of a prospective randomized clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2012.02494.x · RCT
26. Bassetti M et al. (2014). Anti-infective therapy of peri-implantitis with adjunctive local drug delivery or photodynamic therapy: 12-month outcomes of a randomized controlled clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12155 · RCT
27. Shetty B et al. (2022). Role of antimicrobial photodynamic therapy in reducing subgingival oral yeasts colonization in patients with peri-implant mucositis. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2022.102803 · RCT
28. Rakašević D et al. (2016). Efficiency of photodynamic therapy in the treatment of peri-implantitis – A three-month randomized controlled clinical trial. *Srp Arh Celok Lek*. https://pubmed.ncbi.nlm.nih.gov/29652462/ · RCT
29. Arısan V et al. (2025). Photodynamic Therapy as an Adjunct to Resective and Regenerative Surgical Treatment of Peri-Implantitis: A Prospective Cohort of 72 Patients Followed for 18 Months. *Oral Health Prev Dent*. https://doi.org/10.3290/j.ohpd.c_2078 · clinical study
30. Sayar F et al. (2019). Efficacy of antimicrobial photodynamic therapy for elimination of Aggregatibacter actinomycetemcomitans biofilm on Laser-Lok titanium discs. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2019.07.012 · in vitro
31. Cabrera Baez RD et al. (2025). Antimicrobial photodynamic therapy protocol for dental implant surfaces decontamination in vitro: A comparison between methylene blue and toluidine blue O. *Lasers Med Sci*. https://doi.org/10.1007/s10103-025-04756-6 · in vitro
32. Huang TC et al. (2019). Enhancing osteoblast functions on biofilm-contaminated titanium alloy by concentration-dependent use of methylene blue-mediated antimicrobial photodynamic therapy. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2019.05.021 · in vitro
33. Saffarpour A et al. (2018). Microstructural Evaluation of Contaminated Implant Surface Treated by Laser, Photodynamic Therapy, and Chlorhexidine 2 percent. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.6325 · in vitro
34. Anil S et al. (2022). Topographical changes and bactericidal efficacy of antimicrobial photodynamic therapy on titanium implant surface. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2022.102882 · in vitro
35. Mohammad Jalaluddin et al. (2025). EVALUATING ANTIMICROBIAL EFFICACY OF DIFFERENT TREATMENT MODALITIES ON DENTAL IMPLANT SURFACE: AN IN VITRO STUDY *BULLETIN OF STOMATOLOGY AND MAXILLOFACIAL SURGERY*. https://doi.org/10.58240/1829006x-2025.21.4-23 · in vitro
36. Balderrama ÍF et al. (2021). The influence of implant surface roughness on decontamination by antimicrobial photodynamic therapy and chemical agents: A preliminary study in vitro. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2020.102105 · in vitro
37. Sousa V et al. (2022). The Effect of Microcosm Biofilm Decontamination on Surface Topography, Chemistry, and Biocompatibility Dynamics of Implant Titanium Surfaces. *Int J Mol Sci*. https://doi.org/10.3390/ijms231710033 · in vitro
38. Flörke C et al. (2022). In-vitro assessment of the efficiency of cold atmospheric plasma on decontamination of titanium dental implants. *Int J Implant Dent*. https://doi.org/10.1186/s40729-022-00411-9 · in vitro
39. Cai Z et al. (2019). Antimicrobial effects of photodynamic therapy with antiseptics on Staphylococcus aureus biofilm on titanium surface. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2019.01.024 · in vitro
40. Eick S et al. (2017). In Vitro-Activity of Er:YAG Laser in Comparison with other Treatment Modalities on Biofilm Ablation from Implant and Tooth Surfaces. *PLoS One*. https://doi.org/10.1371/journal.pone.0171086 · in vitro
41. Salmeron S et al. (2013). Laser therapy as an effective method for implant surface decontamination: a histomorphometric study in rats. *J Periodontol*. https://doi.org/10.1902/jop.2012.120166 · animal study
42. Chambrone L et al. (2018). Antimicrobial photodynamic therapy for the treatment of periodontitis and peri-implantitis: An American Academy of Periodontology best evidence review. *J Periodontol*. https://doi.org/10.1902/jop.2017.170172 · systematic review
43. Birang E et al. (2017). Evaluation of Effectiveness of Photodynamic Therapy With Low-level Diode Laser in Nonsurgical Treatment of Peri-implantitis. *J Lasers Med Sci*. https://doi.org/10.15171/jlms.2017.25 · RCT
44. Yumeng Yan et al. (2025). Photodynamic therapy and peri-implant diseases: a systematic review and meta-analysis *Frontiers in Oral Health*. https://doi.org/10.3389/froh.2025.1614982 · systematic review
45. Yao Lin et al. (2022). A comparative evaluation of lasers and photodynamic therapy in the nonsurgical treatment of peri-implant diseases: A Bayesian network meta-analysis *Photodiagnosis and Photodynamic Therapy*. https://doi.org/10.1016/j.pdpdt.2022.103106 · systematic review
46. Zhe Wang et al. (2026). Comparative effectiveness of novel laser-assisted technologies for treating peri-implantitis: A network meta-analysis of randomized controlled trials *Medicine*. https://doi.org/10.1097/md.0000000000051256 · systematic review
47. Nastri L et al. (2025). The Effect of Adjunctive Antimicrobial Photodynamic Therapy in the Treatment of Peri-Implant Diseases: Systematic Review and Meta-Analysis. *Dent J (Basel)*. https://doi.org/10.3390/dj13120567 · systematic review
48. Murali Srinivasan et al. (2025). Non-surgical management of peri-implantitis with photodynamic therapy: A systematic review and meta-analysis of clinical parameters and biomarkers *Journal of Dentistry*. https://doi.org/10.1016/j.jdent.2025.105680 · systematic review
49. Wilensky A et al. (2023). The efficacy of implant surface decontamination using chemicals during surgical treatment of peri-implantitis: A systematic review and meta-analysis. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13794 · systematic review
50. Jing Cheng et al. (2023). Efficacy of surgical methods for peri-implantitis: a systematic review and network meta-analysis *BMC Oral Health*. https://doi.org/10.1186/s12903-023-02956-6 · systematic review
51. Pia‐Merete Jervøe‐Storm et al. (2015). Adjunctive antimicrobial photodynamic therapy for treating periodontal and peri-implant diseases *Cochrane Database of Systematic Reviews*. https://doi.org/10.1002/14651858.cd011778.pub2 · review
52. Neophytou C et al. (2026). Microbiological Effects of Laser-Assisted Non-Surgical Treatment of Peri-Implantitis: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. *Dent J (Basel)*. https://doi.org/10.3390/dj14010049 · systematic review
53. Xin Li et al. (2025). Efficacy of photodynamic therapy with various photosensitizers for peri-implantitis treatment: a systematic review and meta-analysis of randomized clinical trials *Lasers in Medical Science*. https://doi.org/10.1007/s10103-025-04612-7 · systematic review
54. Thaís B. M. O. Schweigert et al. (2024). Influence of Photosensitizer on Photodynamic Therapy for Peri-Implantitis: A Systematic Review *Pharmaceutics*. https://doi.org/10.3390/pharmaceutics16030307 · systematic review
55. Warakomska A et al. (2025). The Role of Photodynamic Therapy Mediated by Natural Photosensitisers in the Management of Peri-Implantitis: A Systematic Review. *Pharmaceutics*. https://doi.org/10.3390/pharmaceutics17040443 · systematic review
56. Pourhajibagher M et al. (2020). Photo-sonodynamic antimicrobial chemotherapy via chitosan nanoparticles-indocyanine green against polymicrobial periopathogenic biofilms: Ex vivo study on dental implants. *Photodiagnosis Photodyn Ther*. https://doi.org/10.1016/j.pdpdt.2020.101834 · in vitro
57. Shilpa S. Dandekeri et al. (2026). Re-establishing osseointegration following peri-implantitis: a scoping review of implant surface decontamination methods *BMC Oral Health*. https://doi.org/10.1186/s12903-026-10494-0 · review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

12 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “The study concluded that Mechanical debridement combined with photodynamic therapy (MD + PDT) improves peri-implant health and reduces inflammation significantly better than mechanical debridement alone.” — [Pallavi Goswami 2026](https://doi.org/10.5281/zenodo.23053610), Journal of chemical health risks; cited 0.
- “Rose bengal-mediated a-PDT, combined with mechanical debridement, showed superior efficacy in managing peri-implantitis by significantly improving clinical, microbiological, and biochemical outcomes. This approach presents a promising adjunctive therapy for enhanced peri-implantitis management.” — [Nedumaran N et al. 2025](https://doi.org/10.1007/s10103-025-04548-y), Lasers Med Sci; cited 8.
- “Clinical parameters were measured before and after treatment at baseline, 1 month, 3 months and 6 months. Both DLAD and PDT are effective in treating peri-implant mucositis around platform-switch implants, with no significant difference in clinical outcomes.” — [Randhir Kumar et al. 2025](https://doi.org/10.6026/973206300211103), Bioinformation; cited 1.
- “The application of PDT using 805-nm laser and ICG as an adjunct therapy to MD did not provide any additional improvements in the clinical or biologic parameters of peri-implant mucosal inflammation.” — [Reza Pourabbas et al. 2023](https://doi.org/10.4103/1735-3327.367900), Dental Research Journal; cited 23.
- “In the short term, a single session of aPDT as an adjunct to MD is effective in reducing peri-implant soft tissue inflammation and OYC in patients with PIM.” — [Shetty B et al. 2022](https://doi.org/10.1016/j.pdpdt.2022.102803), Photodiagnosis Photodyn Ther; cited 32.
- “The results suggested that LT and PDT have significant short-term benefits in the treatment of primary peri-implantitis.” — [Birang E et al. 2017](https://doi.org/10.15171/jlms.2017.25), J Lasers Med Sci; cited 74.
- “Our results suggest that antimicrobial photodynamic therapy with diode laser and phenothiazine chloride represents a reliable adjunctive treatment to conventional therapy. Photodynamic therapy should, however, be considered a coadjuvant in the treatment of peri-implantitis associated with mechanical (scaling) and surgical (grafts) treatments.” — [Umberto Romeo et al. 2016](https://doi.org/10.1155/2016/7692387), International Journal of Dentistry; cited 95.
- “The present study revealed that adjunctive use of PDT following closed surface scaling could lead to clinical improvement of peri-implant diseases. Further studies are necessary to confirm our results.” — [Mohammad Reza Karimi et al. 2016](https://doi.org/10.15171/jlms.2016.24), Journal of lasers in medical sciences; cited 70.
- “The results indicate that PDT can be used as an adjuvant therapy to surgery for decontamination of implant surface and surrounding peri-implant tissues within the treatment of peri-implantitis.” — [Rakašević D et al. 2016](https://pubmed.ncbi.nlm.nih.gov/29652462/), Srp Arh Celok Lek.
- “Non-surgical mechanical debridement with adjunctive PDT was equally effective in the reduction of mucosal inflammation as with adjunctive delivery of minocycline microspheres up to 12 months. Adjunctive PDT may represent an alternative approach to LDD in the non-surgical treatment of initial peri-implantitis.” — [Bassetti M et al. 2014](https://doi.org/10.1111/clr.12155), Clin Oral Implants Res; cited 312.

2 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

34 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “Current evidence consistently indicates that saliva contamination may adversely affect early biological responses and the osseointegration process by altering titanium surface properties, particularly surface wettability and surface energy. However, as these data are largely derived from in vitro and animal models, caution is warranted when extrapolating the findings to clinical practice.” — [Çi̇ftçi̇ S et al. 2026](https://doi.org/10.1186/s12903-026-08289-4), BMC Oral Health; cited 0.
- “Despite some positive findings, overall success rates for nonsurgical methods remain variable, highlighting the need for standardized treatment protocols and further research to individualize treatment.” — [Giovanni Battista Menchini-Fabris et al. 2026](https://doi.org/10.1016/j.jdip.2026.100004), Journal of Dental Implants and Prosthodontics; cited 0.
- “PDT exerted the most stable short-term efficacy for peri-implantitis. DL and Er:YAG had limited valid benefits. Due to insufficient long-term data, the sustained effects of these treatments and their roles in preventing lesion recurrence and maintaining implant survival are still undetermined.” — [Zhe Wang et al. 2026](https://doi.org/10.1097/md.0000000000051256), Medicine; cited 0.
- “Natural-photosensitizer-based PDT appears to be a valuable adjunct to mechanical debridement for peri-implantitis, enhancing microbial control and clinical outcomes. Standardization of PDT protocols and further well-designed clinical trials with extended follow-up periods are warranted to confirm long-term efficacy and inform evidence-based guidelines.” — [Warakomska A et al. 2025](https://doi.org/10.3390/pharmaceutics17040443), Pharmaceutics; cited 20.
- “PDT enhances antimicrobial efficacy in peri-implant disease treatment, significantly improving PPD, CBL, and BoP when combined with MD. However, due to the overall moderate-to-low certainty of the evidence and some concerns regarding risk of bias in the included studies, these findings should be interpreted with caution.” — [Yumeng Yan et al. 2025](https://doi.org/10.3389/froh.2025.1614982), Frontiers in Oral Health; cited 17.
- “Mechanical debridement with adjunctive systemic antibiotics or photodynamic therapy results in improved clinical outcomes.” — [Giok KC et al. 2025](https://doi.org/10.1016/j.prosdent.2024.03.024), J Prosthet Dent; cited 10.
- “Adjunct PDT significantly enhanced clinical outcomes, particularly for the short-term, with the most notable benefits observed in BOP, PD, PI, and CBL reductions. However, additional benefits in CAL, mucosal recession, and inflammatory biomarkers outcomes remain limited. Standardized protocols and long-term studies are warranted.” — [Murali Srinivasan et al. 2025](https://doi.org/10.1016/j.jdent.2025.105680), Journal of Dentistry; cited 10.

26 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

13 non-randomised clinical studies and 10 case reports or series.

- “Given the pathogenesis of PI, this strategy rationally designed a multifunctional NP with antibacterial and anti-inflammatory functions via spatiotemporal ROS regulation. It provides a potentially novel approach for PI treatment, which may have a profound impact on improving the prognosis of patients with PI and advancing the field of implant dentistry.” — [Zeyu Han et al. 2025](https://doi.org/10.7150/thno.108830), Theranostics; cited 27.
- “Recent developments, particularly dual-light antibacterial photodynamic therapy that combines blue light and near-infrared light, have shown improved antimicrobial effectiveness and a notable decrease in inflammatory biomarkers.” — [Harish Kumar VV 2025](https://doi.org/10.67091/jrdc.2025.8115), ; cited 0.
- “PDT as an adjunct to conventional peri-implantitis treatment with GBR resulted in statistically significantly lower PPD values. However, no additional benefits were observed for infection resolution, maintenance of infection-free status, MBL or BOP. Initial improvements in both groups followed by gradual recurrences in clinical parameters over 18 months.” — [Arısan V et al. 2025](https://doi.org/10.3290/j.ohpd.c_2078), Oral Health Prev Dent.
- “The combined Nd: YAG-Er: YAG laser surgical therapy of peri-implantitis seemed to lead to more favorable improvements in regard to bleeding on probing six months after treatment compared to the conventional mechanical decontamination of the implant surface. None of the methods was found superior in the modification of bone loss biomarkers (RANKL, OPG) six months after treatment.” — [Fragkioudakis I et al. 2023](https://doi.org/10.3390/dj11030061), Dent J (Basel); cited 21.
- “For the implant patients, the SRP+ALAD-PDT was correlated to a decrease in PPD and BOP, and a slight increase in the number of exposed threads. However, the results were statistically significant only for PPD (p < 0.001).” — [Roberto Rossi et al. 2022](https://doi.org/10.3390/antibiotics11091267), Antibiotics; cited 10.
- “PDT is an effective adjunctive therapy to MD in peri-implantitis treatment since it can improve clinical parameter values, significantly reduce P. gingivalis, and decrease proinflammatory cytokines.” — [Agung Sosiawan et al. 2022](https://doi.org/10.20473/ijdm.v5i2.2022.62-65), Indonesian Journal of Dental Medicine; cited 2.

7 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

30 in vitro / ex vivo and 5 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “Laser plus ICG-loaded CNPs and CHX had comparably the highest decontamination efficacy. This study demonstrated that aPDT with ICG-loaded CNPs significantly reduced the A. actinomycetemcomitans colony count on dental implants, showing comparable efficacy to CHX.” — [Sayar F et al. 2025](https://doi.org/10.1038/s41598-025-15871-3), Sci Rep; cited 9.
- “Dyes alone were similar (p = 0.518) and had no antimicrobial effect. The antimicrobial photodynamic therapy protocol was effective in implant decontamination in vitro regardless of the photosensitizer used, and the dyes without light activation do not seem to be an indicated method for this purpose.” — [Cabrera Baez RD et al. 2025](https://doi.org/10.1007/s10103-025-04756-6), Lasers Med Sci; cited 1.
- “Photodynamic therapy caused minimal surface alteration compared to other modalities. It may offer the best balance between antimicrobial efficacy and surface preservation in peri-implantitis management.” — [Mohammad Jalaluddin et al. 2025](https://doi.org/10.58240/1829006x-2025.21.4-23), BULLETIN OF STOMATOLOGY AND MAXILLOFACIAL SURGERY; cited 0.
- “The microbiological study showed that all irradiation parameter sets achieved a complete bacterial reduction (99.9999% or 6-log10) after ten consecutive scans, however only parameter set C did not exceed the temperature threshold.” — [Ahrens M et al. 2024](https://doi.org/10.1038/s41598-024-68780-2), Sci Rep; cited 13.
- “The commercially available PDT and PTT adjuvant treatment systems were associated with the largest statistically significant reduction in periopathogenic bacteria on implant surfaces. However, activation with laser light at a suitable wavelength is necessary to achieve the bactericidal effects.” — [Wenzler JS et al. 2024](https://doi.org/10.3390/jcm13144212), J Clin Med; cited 7.
- “aPDT with Curcumin and LED can reduce A.a biofilm on implant surfaces and can be used as a safe and non-invasive disinfection method to reduce A.a biofilm on implant surfaces.” — [Etemadi A et al. 2023](https://doi.org/10.1016/j.pdpdt.2023.103833), Photodiagnosis Photodyn Ther; cited 7.

24 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “The results suggest that PDT and OFD have significant benefits in peri-implantitis treatment by reducing bacterial count. The presence of bacterial complex with different response to therapeutic modality suggests the use of combined decontamination methods for peri-implantitis treatment.” — [Madi M et al. 2018](https://doi.org/10.1155/2018/7570105), Biomed Res Int; cited 28.
- “aPDT and TTC successfully decontaminated infected implant surfaces. Implant decontamination with aPDT appears to be a viable alternative to TTC in the management of peri-implantitis infection.” — [Ramos UD et al. 2018](https://doi.org/10.1002/JPER.17-0630), J Periodontol; cited 20.
- “Within the limits of the study, the combination of mechanical and chemical treatment proved to be the most effective treatment for disinfection of the anodized implant surface.” — [Htet M et al. 2016](https://doi.org/10.1902/jop.2016.150615), J Periodontol; cited 56.
- “Group aPDT showed more favorable results in parameter area of reactive tissue than the other methods after day 7, but over longer time periods all methods produced outcomes equivalent to sterile implants.” — [Salmeron S et al. 2013](https://doi.org/10.1902/jop.2012.120166), J Periodontol; cited 130.

1 further animal study entry of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Parameters as stated in the abstracts

- “The control group received mechanical debridement with a sham laser, while the test group received mechanical debridement followed by aPDT (Toluidine or Methylene Blue photosensitizer incubated for 1–3 minutes and irradiated with a 660/680 nm diode laser for 60–120 seconds).” — [Pallavi Goswami 2026](https://doi.org/10.5281/zenodo.23053610) (RCT).
- “These were treated with TiBrushes (TiB), combination of TiB and photodynamic therapy (PDT), combination of TiB and 0.2%CHX/1%NaClO, plus or minus Ultraviolet-C (UV-C) radiation.” — [Sousa V et al. 2022](https://doi.org/10.3390/ijms231710033) (in vitro).
- “The aim of the current study was to comparatively assess the efficiency of three different adjunctive therapy options (cold atmospheric plasma, \[CAP\], photodynamic therapy \[PDT\] and chemical decontamination via 35% phosphoric acid gel \[PAG\]) on decontamination of titanium implant surfaces in-vitro.” — [Flörke C et al. 2022](https://doi.org/10.1186/s40729-022-00411-9) (in vitro).
- “The wells containing P. gingivalis suspension were randomly divided into three experimental groups for exposure to ½ MIC phycocyanin for 5 minutes, minimum lethal dose of diode laser (635 nm, 4 minutes), and aPDT with phycocyanin and diode laser.” — [Etemadi A et al. 2022](https://doi.org/10.34172/jlms.2022.55) (in vitro).
- “Decontamination of implants was performed in duplicate by three protocols: antimicrobial photodynamic therapy (aPDT), EDTA associated with citric acid (EDTA + CA) and 0.12 % chlorhexidine (CHX).” — [Balderrama ÍF et al. 2021](https://doi.org/10.1016/j.pdpdt.2020.102105) (in vitro).
- “A full thickness open-flap was performed to allow directly mechanical debridement, followed by aPDT using methylene blue 200 μg/mL under red laser irradiation (660 nm, 100 mW, 9 J), providing decontamination of implant surface and surrounding tissue.” — [Garcia de Carvalho G et al. 2020](https://doi.org/10.1016/j.pdpdt.2020.101705) (case report/series).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Air-Flow** — 2 entries
- **Perio-Flow** — 1 entry
- **TiBrush** — 1 entry
- **Emdogain** — 1 entry
- **Perisolv** — 1 entry
- **Cavitron** — 1 entry
- **Vector** — 1 entry

Manufacturers: Geistlich (3), Hu-Friedy (3), EMS (2), Dentsply Sirona (2), Dentsply (2), Sirona (2), Straumann (2), Fotona (1), KaVo (1), Dentium (1), Zimmer (1), Zimmer Biomet (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (20 different): chlorhexidine (37), photosensitizer dye (31), saline (25), hydrogen peroxide (17), antibiotics (systemic) (15), citric acid (9), minocycline (7), amoxicillin (7), metronidazole (5), tetracycline (5), enamel matrix derivative (3), phosphoric acid / etching gel (3), ozone (2), doxycycline (2), sodium hypochlorite (2), sterile water (2), chloramine (1), EDTA (1), Perisolv (1), povidone-iodine (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (146)

The 146 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- Next: [7. Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/)


---

# 7. Implantoplasty

Chapter 7 of an evidence-based reader on implant surface decontamination in peri-implantitis: 154 entries on implantoplasty — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/implantoplasty/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about implantoplasty (removing the implant threads and roughness)?

**Key facts — Implantoplasty**

- Entries in this chapter: 154 of 819 (2003–2026): RCT 11 · clinical study 22 · case report/series 19 · systematic review 23 · consensus 1 · review 13 · in vitro 43 · animal study 7 · not classified 15
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Frank Schwarz et al. 2011](https://doi.org/10.1111/j.1600-051x.2010.01690.x) (294); [Prathapachandran J et al. 2012](https://doi.org/10.4103/1735-3327.104867) (285)
- Products named by the authors: Perio-Flow (3), Air-Flow (3), Ti-Brush (2), i-Brush (2), TiBrush (1), Cavitron (1), Vector (1)
- Manufacturers named by the authors: Straumann (7), Komet (6), Geistlich (5), KaVo (5), EMS (4), Hu-Friedy (3), Nobel Biocare (2), Zimmer (2), Dentsply (2), Neobiotech (1)
- Chemical agents used alongside: chlorhexidine (19), saline (19), antibiotics (systemic) (12), hydrogen peroxide (12), citric acid (11), amoxicillin (8), EDTA (3), sterile water (3)
- Often studied together with: [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (32), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (30), [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (25), [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) (24)
- Entries naming the NiTi Brush: 7 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

The exposed, supracrestal part of the implant is ground with rotary diamond or carbide burs and then polished with finer burs, stones or silicone polishers, so that the threads and the rough surface are removed and a smooth, cleanable surface remains. It changes the implant itself, which is why heat generation, titanium particle release and the loss of implant strength are recurring themes of the laboratory literature.


### Mechanism and use, as the papers describe it

The publications in this chapter describe implantoplasty as the mechanical modification of the implant itself, with removal of the threads and smoothing of the surface, proposed as part of surgical peri-implantitis treatment.[1] Contaminated titanium layers are ground away with rotary instruments so that the remaining surface retains less plaque, at the cost of a thinner implant wall.[2] Laboratory protocols describe diamond or tungsten carbide burs of decreasing grit followed by finer diamonds, an Arkansas stone or silicone polishers, and sonic tips have been tested as an alternative to burs.[3,4,5]

In the trials of Schwarz and colleagues, implantoplasty was performed at the buccally and supracrestally exposed implant parts after access flap surgery and granulation tissue removal, while the intrabony surface was decontaminated by other means and augmented.[6,7] Monje et al. compared implantoplasty limited to the supracrestal component with extension into a contained intrabony component, and Rosen described implantoplasty above and below the bone crest.[8,9] In resective protocols the procedure is combined with an apically positioned flap and osteoplasty, and in combined protocols with regenerative treatment of the intrabony component.[10,11] One clinical study applied 0.05% chlorhexidine gluconate and 3% hydrogen peroxide before debridement with tungsten carbide instruments, and laboratory studies applied citric acid, EDTA, hydrogen peroxide or saline to the machined surface afterwards to repassivate the titanium.[12,13]


### Reported operating conditions

Ramel et al. tested six sequences on sandblasted and acid-etched implants: diamonds of 106, 40 and 15 µm grit followed by Brownie and Greenie silicone polishers or by an Arkansas stone, diamonds of 106, 40 and 4 µm, and complete sequences of 106, 40, 15, 8 and 4 µm, the last two each with or without a Greenie polisher.[3] Treatment time ranged from 13 ± 2 min for the Arkansas stone sequence to 21 min for the longest sequences.[3] Yildiz et al. used tungsten carbide sequences from two manufacturers (Komet Dental; Hager & Meisinger GmbH) and a diamond sequence of 125, 40 and 15 µm grit, with or without a Brownie polisher.[14] Costa-Berenguer et al. reported a mean time of 10 min 48 s with high-speed burs and silicone polishers, and Park et al. recorded 5 min 27 s for implantoplasty against 3 min 1 s for rotating titanium brushes.[15,16]

Sharon et al. applied diamond, premium-line diamond, carbide and smooth burs on a high-speed handpiece with water-spray cooling for 60 s and measured removal of 59.24, 29.39, 11.35 and 0.19 mg of titanium respectively.[17] Machining depth has been varied between 0.2, 0.4 and 0.6 mm of wall reduction, 0.4 mm corresponding to the thread height of the tested system.[18,19] Implants treated in a phantom head were rougher and took longer than those treated on a table top, and residual threads and silicone debris were more frequent at posterior mandibular sites with adjacent teeth and a crown in place.[20,21]


### Effects on the implant surface reported in laboratory studies

Mean Ra after the six sequences of Ramel et al. ranged from 0.32 ± 0.14 µm to 0.98 ± 0.30 µm, against 1.94 ± 0.47 µm for the untreated surface.[3] Costa-Berenguer et al. measured Sa of 0.1 ± 0.02 µm after polishing against 0.75 ± 0.08 µm originally, and Camps-Font et al. reported Sa falling from 1.76 to 0.49 µm.[15,22] Yildiz et al. found that tungsten carbide burs produced a roughness similar to or lower than that of turned surfaces even without polishing, whereas the diamond sequence required additional polishing.[14] Toma et al. observed that implantoplasty changed the morphology, elemental composition and wettability of titanium discs, and other studies found residual titanium shavings, silicone debris, carbon and aluminium from polishers and tips.[23,5,15] In situ, implantoplasty-treated surfaces accumulated less biofilm than turned or modified surfaces.[24,25]

Implantoplasty releases micro- and nanoparticles; Wu et al. found most particles below 100 nm, with numbers differing between implant systems.[26] Toledano-Serrabona et al. characterised Ti6Al4V debris of 6–1850 µm with vanadium ion release and loss of cytocompatibility on osteoblasts and fibroblasts, and Barrak et al. reported reduced fibroblast viability from grade 5 alloy particles.[27,28] Particles induced pro-inflammatory macrophage responses in vitro, and in rats debris placed in a mandibular defect produced a foreign body reaction and raised titanium ion concentrations in several organs.[29,30,31] Two systematic reviews concluded that particles of 100 nm to 54 µm are detectable in peri-implant tissues without a consistent clinical association with peri-implantitis.[32,33]

Temperature rose by about 1.5 °C under water-spray cooling, and a systematic review states that implantoplasty does not increase temperature provided proper cooling is used.[17,1] Chan et al. found the bending strength of 3.75 mm implants reduced from 613.9 to 511.4 N while 4.7 mm implants were unaffected, and Costa-Berenguer et al. found no significant difference for 4.1 mm external-connection implants (896 versus 880 N).[34,15] Bertl et al. and Stavropoulos et al. reported significantly reduced failure strength, with narrow tissue-level implants and advanced bone loss most affected.[35,36] Fatigue limits fell from about 351 N to 185–301 N depending on machining depth, and fatigue life decreased by 30% in another study.[18,37] A 2025 meta-analysis estimated a fracture-resistance difference of −232 MPa with high heterogeneity, and a 2025 systematic review found the external hexagon connection most affected and the conical connection least.[38,39] Corrosion current density increased after implantoplasty with pitting at the junction between machined and rough areas, and bacterial contamination further reduced fatigue and corrosion resistance.[22,40,41]


### Position in treatment protocols

Non-augmentative therapy including implantoplasty is described for primarily horizontal bone loss or wide defects with limited regenerative potential in aesthetically non-demanding areas, and in combined protocols for the supracrestal and buccal component while the intrabony component is augmented.[42,43,44] A 2021 meta-analysis reported a weighted mean difference of −1.11 mm in probing depth favouring adjunctive implantoplasty, and a network meta-analysis reported additional probing depth improvement over hand curettes at 6 and 12 months.[45,46] Baima et al. reported favourable results for titanium brushes and implantoplasty as single methods while concluding that no method showed clear evidence of superiority.[47]

Cruz et al. found no added benefit over mechanical debridement alone at 24 months, Ravidà et al. found survival primarily influenced by bone loss at treatment rather than by implantoplasty, and Park et al. demonstrated non-inferiority of rotating titanium brushes.[48,49,16] The 2021 EAO consensus stated that implantoplasty had no influence on mucosal recession, whereas Monje et al. and Bolun et al. observed more recession where implantoplasty was more extensive or replaced titanium brushes.[50,8,12] Schwarz et al. found 4- and 7-year outcomes of combined therapy unaffected by whether the remaining surface was treated with an Er:YAG laser or with plastic curettes, cotton pellets and sterile saline.[51,7]


### Limitations and open questions as stated by the authors

Stavropoulos et al. noted no fracture among 217–291 implants followed for 3–126 months but called the evidence limited.[1] Goh et al. found no clear evidence on fracture resistance because methodological differences prevented comparison between in vitro studies.[52] The certainty of evidence on particle effects was rated low, and Padullés-Roig et al. pointed to the absence of agreed protocols for machining depth.[33,18] Valeriani et al. concluded that no universally safe tool for preserving surface integrity could be identified, and the AAP/AO review listed implantoplasty among methods inducing significant surface alteration and thread flattening.[53,54] Cruz et al. and Khayat et al. called for larger randomised trials, and a 2026 review advised judicious use because of particle release.[48,55,56]


### Sources cited in this description (56)

1. Stavropoulos A et al. (2019). Mechanical and biological complications after implantoplasty-A systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13499 · systematic review
2. Tsampli A et al. (2024). In vitro pilot study comparing a novel implantoplasty sonic instrumentation protocol with a conventional protocol using burs. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14231 · in vitro
3. Ramel CF et al. (2016). Surface roughness of dental implants and treatment time using six different implantoplasty procedures. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12682 · in vitro
4. Beheshti Maal M et al. (2020). Experimental implantoplasty outcomes correlate with fibroblast growth in vitro. *BMC Oral Health*. https://doi.org/10.1186/s12903-020-1012-1 · in vitro
5. Sivolella S et al. (2021). Implantoplasty: Carbide burs vs diamond sonic tips. An in vitro study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13702 · in vitro
6. Frank Schwarz et al. (2011). Impact of the method of surface debridement and decontamination on the clinical outcome following combined surgical therapy of peri-implantitis: a randomized controlled clinical study *Journal Of Clinical Periodontology*. https://doi.org/10.1111/j.1600-051x.2010.01690.x · RCT
7. Schwarz F et al. (2017). Combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination: a 7-year follow-up observation. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12648 · RCT
8. Monje A et al. (2026). Extent of Implantoplasty in the Combined Surgical Therapy of Peri-Implantitis: A Quasi-Randomized Clinical Trial. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.70144 · RCT
9. Rosen PS et al. (2023). Subcrestal Implantoplasty for Treating Peri-implantitis With Regenerative Care-How Deep Should Treatment Go? *Compend Contin Educ Dent*. https://pubmed.ncbi.nlm.nih.gov/37708040/ · not classified
10. Englezos E et al. (2018). Resective Treatment of Peri-implantitis: Clinical and Radiographic Outcomes After 2 Years. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.3386 · clinical study
11. Monje A et al. (2022). Resolution of peri-implantitis by means of implantoplasty as adjunct to surgical therapy: A retrospective study. *J Periodontol*. https://doi.org/10.1002/JPER.21-0103 · clinical study
12. Radu Bolun et al. (2024). Mechanical modification of the implant surface as an adjunctive measure during surgical treatment of peri-implantitis *Journal of Stomatological Medicine*. https://doi.org/10.53530/1857-1328.24.1.09 · clinical study
13. Millas L et al. (2026). Repassivation of Titanium Surface with Different Disinfectants After Implantoplasty: Effects on Corrosion, Ion Release, Cytotoxicity and Bacterial Behaviour-An In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj14090587 · in vitro
14. Hulya Yildiz et al. (2022). Titanium implant surface roughness after different implantoplasty protocols: A laboratory study *Clinical and Experimental Dental Research*. https://doi.org/10.1002/cre2.659 · in vitro
15. Costa-Berenguer X et al. (2018). Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13037 · in vitro
16. Park SH et al. (2026). Implantoplasty vs. Rotating Titanium Brushes in the Surgical Treatment of Peri-Implantitis: A 1-Year Randomised Controlled Clinical Trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.70056 · RCT
17. Sharon E et al. (2013). Efficiency and thermal changes during implantoplasty in relation to bur type. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/j.1708-8208.2011.00366.x · not classified
18. Padullés-Roig E et al. (2026). Mechanical Fatigue of Titanium Dental Implants After Implantoplasty: An In Vitro Study Combined with Finite Element Simulations. *J Funct Biomater*. https://doi.org/10.3390/jfb17050221 · in vitro
19. Padullés-Roig E et al. (2026). Fatigue Behavior of Dental Implants Affected by Peri-Implantitis-Related Bone Loss: Influence of Implantoplasty Evaluated Through In Vitro Testing and Finite Element Modeling. *Dent J (Basel)*. https://doi.org/10.3390/dj14060329 · in vitro
20. Eamonn Donohoe et al. (2026). The Impact of Operator Access on Implant Surface Roughness Following Implantoplasty Procedures: A Laboratory Study *Clinical and Experimental Dental Research*. https://doi.org/10.1002/cre2.70336 · in vitro
21. Burgueño-Barris G et al. (2023). Factors Affecting Implant Surface Roughness and Platform Alterations After Implantoplasty: An In Vitro Study Simulating Different Clinical Scenarios. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.10074 · in vitro
22. Octavi Camps‐Font et al. (2023). Effect of Implantoplasty on Roughness, Fatigue and Corrosion Behavior of Narrow Diameter Dental Implants *Journal of Functional Biomaterials*. https://doi.org/10.3390/jfb14020061 · in vitro
23. Toma S et al. (2016). In vitro evaluation of peri-implantitis treatment modalities on Saos-2osteoblasts. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12686 · in vitro
24. Bertl K et al. (2024). Reduced Biofilm Accumulation on Implants Treated With Implantoplasty-An In Situ Trial With a Within-Subject Comparison. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.70043 · RCT
25. Azzola F et al. (2020). Biofilm Formation on Dental Implant Surface Treated by Implantoplasty: An In Situ Study. *Dent J (Basel)*. https://doi.org/10.3390/dj8020040 · in vitro
26. Wu X et al. (2022). Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. *Materials (Basel)*. https://doi.org/10.3390/ma15020602 · in vitro
27. Toledano-Serrabona J et al. (2021). Physicochemical and Biological Characterization of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part I. *Materials (Basel)*. https://doi.org/10.3390/ma14216507 · in vitro
28. Barrak FN et al. (2020). Particle release from implantoplasty of dental implants and impact on cells. *Int J Implant Dent*. https://doi.org/10.1186/s40729-020-00247-1 · in vitro
29. Gil J et al. (2026). Immunological and tissue reactions to titanium particles generated by the mechanical decontamination of dental implants: In vitro and in vivo study. *Med Oral Patol Oral Cir Bucal*. https://doi.org/10.4317/medoral.27171 · in vitro
30. Toledano-Serrabona J et al. (2023). Ion release and local effects of titanium metal particles from dental implants: An experimental study in rats. *J Periodontol*. https://doi.org/10.1002/JPER.22-0091 · animal study
31. Diogo Pompéu de Moraes et al. (2023). Tracking soluble and nanoparticulated titanium released in vivo from metal dental implant debris using (single-particle)-ICP-MS *Journal of Trace Elements in Medicine and Biology*. https://doi.org/10.1016/j.jtemb.2023.127143 · animal study
32. Suárez-López Del Amo F et al. (2018). Dental implants-associated release of titanium particles: A systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13372 · systematic review
33. Rodríguez Alvarez MB et al. (2025). Release of Titanium Particles After Implantoplasty in the Treatment of Peri-Implantitis: Local and Systemic Implications-An Integrative Systematic Review. *J Clin Med*. https://doi.org/10.3390/jcm14248661 · systematic review
34. Chan HL et al. (2013). Impact of implantoplasty on strength of the implant-abutment complex. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.3227 · in vitro
35. Bertl K et al. (2021). Does implantoplasty affect the failure strength of narrow and regular diameter implants? A laboratory study. *Clin Oral Investig*. https://doi.org/10.1007/s00784-020-03534-8 · in vitro
36. Stavropoulos A et al. (2023). Implantoplasty and the risk of fracture of narrow implants with advanced bone loss: A laboratory study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14132 · in vitro
37. Fonseca D et al. (2024). The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants. *Materials (Basel)*. https://doi.org/10.3390/ma17122944 · in vitro
38. Giovanni Pissu et al. (2025). Effect of the implantoplasty techniques on the fracture resistance of dental implants. Systematic review and meta-analysis *Frontiers in Dental Medicine*. https://doi.org/10.3389/fdmed.2025.1568465 · systematic review
39. Manuel Alejandro León Velastegui et al. (2025). Influence of Different Implantoplasty Designs on the Fatigue Resistance of Dental Implants: A Systematic Review *Journal of Clinical Medicine*. https://doi.org/10.3390/jcm14176103 · systematic review
40. Pablo Lozano et al. (2022). Corrosion Behavior of Titanium Dental Implants with Implantoplasty *Materials*. https://doi.org/10.3390/ma15041563 · not classified
41. Vegas-Bustamante E et al. (2025). Effect of Tribocorrosion on Mechanical Behavior of Titanium Dental Implants: An In Vitro Study. *Materials (Basel)*. https://doi.org/10.3390/ma18051136 · in vitro
42. Kristina Bertl et al. (2021). A Mini Review on Non-augmentative Surgical Therapy of Peri-Implantitis—What Is Known and What Are the Future Challenges? *Frontiers in Dental Medicine*. https://doi.org/10.3389/fdmed.2021.659361 · review
43. Aušra Ramanauskaitė et al. (2020). Surgical Management of Peri-implantitis *Current Oral Health Reports*. https://doi.org/10.1007/s40496-020-00278-y · not classified
44. Galarraga-Vinueza ME et al. (2020). Volumetric assessment of tissue changes following combined surgical therapy of peri-implantitis: A pilot study. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13335 · clinical study
45. Aušra Ramanauskaitė et al. (2021). Efficacy of alternative or adjunctive measures to conventional non-surgical and surgical treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-021-00388-x · systematic review
46. Zhi-Bang Li et al. (2022). The Effect of Nonaugmentative Approaches in the Surgical Treatment of Peri-implantitis: A Systematic Review and Network Meta-analysis *The International Journal of Oral & Maxillofacial Implants*. https://doi.org/10.11607/jomi.9211 · systematic review
47. Baima G et al. (2022). Surface decontamination protocols for surgical treatment of peri-implantitis: A systematic review with meta-analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13992 · systematic review
48. Cruz RKS et al. (2025). Efficacy of implantoplasty in the treatment of peri-implantitis: A 24-month randomized controlled clinical trial. *J Dent*. https://doi.org/10.1016/j.jdent.2025.105844 · RCT
49. Ravidà A et al. (2020). Lack of Clinical Benefit of Implantoplasty to Improve Implant Survival Rate. *J Dent Res*. https://doi.org/10.1177/0022034520944158 · clinical study
50. Schwarz F et al. (2021). Peri-implantitis: Summary and consensus statements of group 3. The 6th EAO Consensus Conference 2021. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13827 · consensus
51. Schwarz F et al. (2013). Four-year follow-up of combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12143 · RCT
52. Rayner Goh et al. (2022). The effect of implantoplasty on dental implant fracture resistance: a systematic review *International Journal of Orofacial and Health Sciences*. https://doi.org/10.31436/ijohs.v3i1.113 · systematic review
53. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
54. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
55. Khayat P et al. (2026). Bone Regeneration Following Implantoplasty: A Retrospective Cohort Study with Long-Term Radiographic Assessment. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.7422 · RCT
56. Lee K et al. (2026). Overview of Treatment Modalities for Peri-Implantitis (Part 2). *Compend Contin Educ Dent*. https://pubmed.ncbi.nlm.nih.gov/42848526/ · review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

11 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Both groups showed favourable outcomes, demonstrating non-inferiority of titanium brushes to implantoplasty.” — [Park SH et al. 2026](https://doi.org/10.1111/jcpe.70056), J Clin Periodontol; cited 8.
- “Implantoplasty alone without osseous surgery, flap repositioning, or use of a graft material or membrane may be a viable option for managing peri-implantitis defects. However, future randomized clinical trials with larger sample sizes are necessary to validate current findings.” — [Khayat P et al. 2026](https://doi.org/10.11607/prd.7422), Int J Periodontics Restorative Dent; cited 2.
- “BIS enabled the accurate identification of mature biofilm and facilitated site‑specific, conservative decontamination. This selective approach, which targets infected surfaces while preserving implant structure, may be clinically advantageous for peri‑implantitis management. Further randomized controlled trials are warranted to validate these findings.” — [Seo-Jun Lee et al. 2026](https://doi.org/10.1186/s12903-025-07644-1), BMC Oral Health; cited 1.
- “Combined surgical therapy for peri-implantitis, including implantoplasty and regeneration of the intrabony component, is effective in arresting disease progression and restoring peri-implant health. Extending implantoplasty to the contained intrabony compartment appears to provide additional clinical and radiographic benefits.” — [Monje A et al. 2026](https://doi.org/10.1111/cid.70144), Clin Implant Dent Relat Res.
- “Evidence is insufficient to suggest that incorporation of implantoplasty improves clinical parameters during the surgical treatment of peri‑implantitis, compared to mechanical debridement alone.” — [Cruz RKS et al. 2025](https://doi.org/10.1016/j.jdent.2025.105844), J Dent; cited 6.
- “Implantoplasty can generate a surface significantly less conducive to biofilm accumulation in the short term compared to pristine implants with turned or modified surfaces.” — [Bertl K et al. 2024](https://doi.org/10.1002/cre2.70043), Clin Exp Dent Res; cited 4.
- “This pilot study indicated using laser irradiation during peri-implantitis regenerative therapy may aid in better probing PD reduction. Nonetheless, a larger sample size and longer follow-up is needed to confirm if Er:YAG laser irradiation provides additional clinical benefits for peri-implantitis regenerative therapy (Clinicaltrials.gov: NCT03127228).” — [Wang CW et al. 2021](https://doi.org/10.1002/JPER.20-0040), J Periodontol; cited 129.
- “Within the limitations of this 6-month follow-up study, implantoplasty is as effective as glycine air polishing for the surgical treatment of peri-implantitis.” — [Jérôme Frédéric Lasserre et al. 2020](https://doi.org/10.11607/jomi.6677), The International Journal of Oral & Maxillofacial Implants; cited 70.
- “Combined surgical resective/regenerative therapy of advanced peri-implantitis was effective on the long-term, but not influenced by the initial method of surface decontamination.” — [Schwarz F et al. 2017](https://doi.org/10.1111/jcpe.12648), J Clin Periodontol; cited 185.
- “The 4-year clinical outcomes obtained following combined surgical resective/regenerative therapy of advanced peri-implantitis were not influenced by the method of surface decontamination.” — [Schwarz F et al. 2013](https://doi.org/10.1111/jcpe.12143), J Clin Periodontol; cited 148.

1 further RCT entry of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

23 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Titanium particles generated during implantoplasty are detectable but show no consistent clinical association with peri-implantitis or significant inflammation. Implantoplasty may be applied selectively, although robust long-term clinical studies are still required. No protocol was registered.” — [Rodríguez Alvarez MB et al. 2025](https://doi.org/10.3390/jcm14248661), J Clin Med; cited 8.
- “the tungsten carbide drills resulted in less fracture resistance loss than the diamond and tungsten carbide drills for the dental implants submitted to implantoplasty procedures. Systematic Review Registration: \[http://www.prisma-statement.org\], identifier \[INPLASY202460018\].” — [Giovanni Pissu et al. 2025](https://doi.org/10.3389/fdmed.2025.1568465), Frontiers in Dental Medicine; cited 2.
- “Implantoplasty reduces the mechanical strength of dental implants. Increased implantoplasty length correlates with decreased resistance, particularly affecting narrow implants. The prosthetic connection most affected by this procedure is the external hexagon, followed by the internal hexagon, with the conical connection being the most resistant.” — [Manuel Alejandro León Velastegui et al. 2025](https://doi.org/10.3390/jcm14176103), Journal of Clinical Medicine; cited 2.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.
- “Owing to the limited available data, clinical efficacy of photo/mechanical and physical implant surface decontamination in conjunction with surgical peri-implantitis therapy is inconclusive. However, titanium brushes may be beneficial in reducing signs of inflammation.” — [Ramanauskaite A et al. 2023](https://doi.org/10.1111/jcpe.13783), J Clin Periodontol; cited 44.
- “Surgical regenerative treatment was a predictable option in the management of PI and in improving the clinical parameters of peri-implant tissues in the short term, mainly when using porous titanium granules, alloplastic bone grafts, and xenografts.” — [Castro F et al. 2023](https://doi.org/10.1016/j.sdentj.2023.05.022), Saudi Dent J; cited 32.

15 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

- “Prosthesis overcontouring and impaired access to oral hygiene procedures increases risk for peri-implantitis. When indicated, reconstructive peri-implantitis treatment may facilitate the maintenance of post-operative peri-implant soft-tissue levels.” — [Schwarz F et al. 2021](https://doi.org/10.1111/clr.13827), Clin Oral Implants Res; cited 163.


## Clinical studies and case reports

22 non-randomised clinical studies and 19 case reports or series.

- “, including the small sample size, short follow-up period, and heterogeneity in implant-related factors such as prosthetic design, peri-implant soft tissue, implant systems, and surface characteristics, combined surgical therapy was associated with improvements in clinical and radiographic parameters in implants affected by peri-implantitis with complex bone defects.” — [SunHo Ahn et al. 2026](https://doi.org/10.1563/aaid-joi-d-26-00003), Journal of Oral Implantology; cited 0.
- “Surgical peri-implantitis outcome was associated with systemic antibiotic, surgeon, molar site, overdenture, baseline suppuration and PD.” — [Zhou W et al. 2026](https://doi.org/10.1111/jcpe.70115), J Clin Periodontol.
- “PDT as an adjunct to conventional peri-implantitis treatment with GBR resulted in statistically significantly lower PPD values. However, no additional benefits were observed for infection resolution, maintenance of infection-free status, MBL or BOP. Initial improvements in both groups followed by gradual recurrences in clinical parameters over 18 months.” — [Arısan V et al. 2025](https://doi.org/10.3290/j.ohpd.c_2078), Oral Health Prev Dent.
- “Individualized treatment plans are essential for managing peri-implant conditions effectively. Non-surgical therapies are effective for early-stage disease, while surgical interventions are necessary for advanced cases. Long-term success depends on integrating these approaches with regular follow-up care and patient education.” — [Adnan Saeed Siddiqui et al. 2024](https://doi.org/10.71000/cghg8156), Insights-Journal of Health and Rehabilitation; cited 1.
- “The absence of KM does not seem to have a negative effect on healing after therapy for the studied period of 3 years. The authors conclude that resective surgery combined with implantoplasty seems to be a reliable method for arresting the progression of peri-implantitis.” — [Emmanuel Englezos et al. 2024](https://doi.org/10.11607/prd.7322), The International Journal of Periodontics & Restorative Dentistry; cited 0.
- “Implantoplasty is more suitable for lateral areas. Implant surface polishing is indicated at implant sites where no bone regeneration is expected.” — [Radu Bolun et al. 2024](https://doi.org/10.53530/1857-1328.24.1.09), Journal of Stomatological Medicine; cited 0.

16 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

43 in vitro / ex vivo and 7 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “Although a good agreement between numerical and experimental results was observed, these findings should be interpreted with caution due to the in vitro testing conditions and the assumptions inherent to the finite element simulations.” — [Padullés-Roig E et al. 2026](https://doi.org/10.3390/jfb17050221), J Funct Biomater; cited 3.
- “Titanium particles released during implantoplasty induce pro-inflammatory responses.” — [Gil J et al. 2026](https://doi.org/10.4317/medoral.27171), Med Oral Patol Oral Cir Bucal; cited 1.
- “Excessive marginal resection significantly decreases the fatigue resistance and long-term mechanical reliability of dental implants, particularly when combined with implantoplasty. The main limitations of this study include is in vitro design, the assumptions inherent to the numerical models, and the variability associated with implantoplasty procedures.” — [Padullés-Roig E et al. 2026](https://doi.org/10.3390/dj14060329), Dent J (Basel); cited 1.
- “Implants treated with IP in the phantom-head set-up exhibited significantly greater surface roughness and required longer procedural time compared to those treated in the table-top model, but did not influence material loss.” — [Eamonn Donohoe et al. 2026](https://doi.org/10.1002/cre2.70336), Clinical and Experimental Dental Research; cited 0.
- “CA and H2O2 improved surface properties after implantoplasty, with CA providing the most favorable combination of corrosion resistance, minimal ion release and antibacterial effect.” — [Millas L et al. 2026](https://doi.org/10.3390/dj14090587), Dent J (Basel); cited 0.
- “, the wettability and surface roughness of dental implant material surfaces were greatly impacted by all surface treatment techniques.By generating the lowest contact angle values, chemical cleaning with citric acid demonstrated the greatest increase in wettability.While glycine powder air-abrasion produced enhanced surface roughness with favorable wettability, mechanical implantoplasty/ polishing produced the …” — [Naman Awasthi et al. 2026](https://doi.org/10.5005/jp-journals-10024-4062), The Journal of Contemporary Dental Practice; cited 0.

37 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “The surgical treatment of peri-implantitis lesions remains challenging. Soft tissue grafting showed clinical benefits by reducing changes in the peri-implant mucosa. The effect of hard tissue grafting on bone regeneration was very limited.” — [Young Woo Song et al. 2026](https://doi.org/10.5051/jpis.2500440022), Journal of Periodontal & Implant Science; cited 2.
- “When applying DexNPs, bone bridging processes were located surrounding the CaP biomaterial. The presence of Tid reduces the bone healing and DexNPs doped on CaP produced an increase in the osteogenic potential, improving the bone defect closure.” — [Toledano M et al. 2026](https://doi.org/10.1016/j.dental.2025.12.002), Dent Mater; cited 1.
- “Tid tended to increase the M1/M2 ratio, leading to a pro-inflammatory cellular profile. Dex-NPs with CaP prompted the M1/M2 ratio decrease in the presence of Tid. Hence, reducing Tid-induced inflammation and osteolysis and thus gaining both osteoconductivity and neovascularization within the bone defect.” — [Toledano M et al. 2026](https://doi.org/10.1016/j.jdent.2026.106706), J Dent; cited 0.
- “Although further studies are required to confirm the clinical relevance of these results, Ti metal particles in the jaw might increase the concentration of metal ions in vital organs and induce a foreign body reaction.” — [Toledano-Serrabona J et al. 2023](https://doi.org/10.1002/JPER.22-0091), J Periodontol; cited 43.

3 further animal study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Parameters as stated in the abstracts

- “Three surfaces were analyzed: physiological saline (Ctr), 25% citric acid (AC), and citric acid with collagen and magnesium nitrate hexahydrate (AC500/Mg).” — [Oliván S et al. 2026](https://doi.org/10.3390/biomimetics11020116) (in vitro).
- “There was a large heterogeneity of methods for treating PI: (1) resective surgery with osteoplasty and surface debridement (implantoplasty, IP); (2) the use of medications/antiseptic (0.12% chlorhexidine + 0.05% cetylpyridinium chlorine) or acids (phosphoric acid 35%); and (3) adjunctive use of laser.” — [Smail Belasla et al. 2025](https://doi.org/10.11138/oi.v17i1.115) (review).
- “They were treated with four different solutions: 25% citric acid, 25% citric acid with the addition of collagen 0.25 g/L, 25% citric acid with the addition of 0.50 g/L and the latter with the addition of 1% Mg (NO3)2.” — [Pilar Fernández-Garrido et al. 2024](https://doi.org/10.3390/coatings14091093) (in vitro).
- “Subsequently, a minimum of four series of cyclic loads were applied with a servo-hydraulic mechanical testing machine (5 × 106 cycles at 15 Hz, between a maximal nominal value-starting at 529 N in the IP group and 735 N in the control group-and 10% of that force).” — [Octavi Camps‐Font et al. 2023](https://doi.org/10.3390/jfb14020061) (in vitro).
- “The other microimplants were divided into seven different decontamination protocols (12 S/R per group): 24% EDTA, 2% chlorhexidine (CHL), gauze soaked in 2% chlorhexidine (GCHL), gauze soaked in ultrapure water (GMQ), scaling (SC), titanium brush (TiB), and implantoplasty (IP).” — [Stuani VT et al. 2021](https://doi.org/10.1002/JPER.20-0324) (in vitro).
- “The shortest treatment time was recorded for group AS (13 ± 2 min) and the longest for CDG (21 ± 2 min) and BG (21 ± 4 min).” — [Ramel CF et al. 2016](https://doi.org/10.1111/clr.12682) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Perio-Flow** — 3 entries
- **Air-Flow** — 3 entries
- **Ti-Brush** — 2 entries
- **i-Brush** — 2 entries
- **TiBrush** — 1 entry
- **Cavitron** — 1 entry
- **Vector** — 1 entry

Manufacturers: Straumann (7), Komet (6), Geistlich (5), KaVo (5), EMS (4), Hu-Friedy (3), Nobel Biocare (2), Zimmer (2), Dentsply (2), Neobiotech (1), Dentium (1), BioHorizons (1), W&H (1), Zimmer Biomet (1), Sirona (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (18 different): chlorhexidine (19), saline (19), antibiotics (systemic) (12), hydrogen peroxide (12), citric acid (11), amoxicillin (8), EDTA (3), sterile water (3), phosphoric acid / etching gel (3), tetracycline (3), minocycline (3), metronidazole (3), hypochlorous acid (2), doxycycline (2), enamel matrix derivative (2), povidone-iodine (2), photosensitizer dye (2), chloramine (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (154)

The 154 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/implantoplasty/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [3. Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [6. Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/)
- Next: [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)


---

# 8. Ultrasonic, sonic and piezoelectric instruments

Chapter 8 of an evidence-based reader on implant surface decontamination in peri-implantitis: 148 entries on ultrasonic, sonic and piezoelectric instruments — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about ultrasonic and piezoelectric scalers for implant surface debridement?

**Key facts — Ultrasonic, sonic and piezoelectric instruments**

- Entries in this chapter: 148 of 819 (2005–2026): RCT 15 · clinical study 15 · case report/series 12 · systematic review 15 · review 11 · in vitro 74 · animal study 2 · not classified 4
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Figuero E et al. 2014](https://doi.org/10.1111/prd.12049) (521); [Rokaya D et al. 2020](https://doi.org/10.1055/s-0040-1715779) (293)
- Products named by the authors: Piezon (9), Air-Flow (5), AIRFLOW (4), Perisolv (3), Waterlase (3), Perio-Flow (2), GalvoSurge (2), Cavitron (2), Vector (2), PIEZON (1)
- Manufacturers named by the authors: EMS (17), Straumann (7), Geistlich (5), Biolase (4), Dentium (4), Hu-Friedy (4), Dentsply Sirona (3), Acteon (3), Fotona (3), Nobel Biocare (3)
- Chemical agents used alongside: chlorhexidine (34), saline (25), hydrogen peroxide (19), antibiotics (systemic) (11), citric acid (11), tetracycline (9), amoxicillin (7), photosensitizer dye (7)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (84), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (71), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (53), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (39)
- Entries naming the NiTi Brush: 4 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Powered scalers whose tip oscillates at ultrasonic (magnetostrictive or piezoelectric) or sonic frequency, with tips of stainless steel, titanium, plastic, carbon fibre or PEEK. They are the conventional non-surgical instruments to which newer measures are compared in many trials.


### Mechanism and use, as the papers describe it

Ultrasonic and sonic scalers in the publications in this chapter are powered instruments whose tip oscillates against the implant surface under water irrigation; Mann et al. recorded an elliptical oscillation with the maximum amplitude at the probe tip.[1,2] Tips are described as made of stainless steel, titanium, polyetheretherketone (PEEK), carbon fibre, resin, ceramic and plastic, and as metal inserts with a plastic sleeve or a PEEK fibre coating.[3,4,5,6] Piezoelectric and sonic-driven (air) scalers both appear, and the Vector system is named as a novel ultrasonic device in one trial.[7,8,9] A 2017 review of mechanical instruments noted that ultrasonic systems with different tips had been tested to enhance cleaning around implants.[10]

Clinically the instruments are used for submarginal debridement of peri-implant mucositis and peri-implantitis without flap elevation, alone or combined with curettes or air-polishing.[11,12,13] In surgical protocols ultrasonics with plastic or PEEK tips have been the mechanical step before chemical agents, grafting or titanium brushing, and ultrasonics with glycine air-polishing formed the surface decontamination in a surgical case series.[14,15,16] Ultrasonic PEEK inserts are also used in supportive peri-implant care on implants restored with ceramic crowns.[17] Tang et al. reported in vitro that ultrasonic scaling removed calcified deposits that glycine air-polishing could not, and Munakata et al. reported a titanium ultrasonic scaler removing a hydroxyapatite coating more completely in deeper parts of a circumferential defect model.[18,19] A survey of dental hygiene professionals found that most Israeli respondents used only hand and sonic or ultrasonic instruments for peri-implant cleaning.[20]


### Reported operating conditions

Laboratory abstracts state contact loads of 25 g, 30 g, 100 g and 200 g, power settings described as low and medium, as 3 of 10 at 25 to 32 kHz, and as 4 W at 20 Hz for a ceramic-tipped scaler.[21,2,3,1,22,4] Instrumentation times are reported as 10 s under continuous automatic motion, 30 scaling motions, 40 strokes with the tip angled tangentially, 20 strokes in 40 s or 100 strokes in 200 s to simulate one or five years of supportive care, 30 s, 60 s, and 120 s.[3,21,2,23,5,24,25] Unursaikhan et al. applied piezoelectric tips at 15° and 45° and concluded that surface change depended more on tip hardness than on application angle, and Mann et al. found that load and power governed the width of defects left by a metallic insert.[7,1]

In clinical trials, ultrasonic debridement was repeated at 3-month intervals over 6 to 12 months, and Discepoli et al. reported in vitro that wider prosthetic emergence angles and deeper mucosal tunnels reduced the efficacy of submucosal ultrasonic debridement.[9,26,27]


### Effects on the implant surface reported in laboratory studies

Metal tips are repeatedly reported to alter titanium: a stainless steel tip caused pronounced macroscopic damage and increased roughness in the thread area, all ultrasonic scaling of SLA implants produced detectable damage to the SLA layer, and metallic devices caused scratching, gouging and material loss on titanium abutments.[28,21,29] Sahrmann et al. found that all tip materials except resin reduced the roughness of two moderately rough surfaces, while steel and titanium tips increased the roughness of untreated and machined surfaces, and that PEEK, carbon and resin tips left extensive residuals matching their own composition.[3] Plastic or PEEK remnants on the implant surface are also reported by Cha et al., Qian et al. and Mann et al., who described a polishing action of plastic-coated probes with minimal damage but plastic deposits left behind.[28,30,1] Giannelli et al. observed incomplete removal of the titanium dioxide layer and marked surface changes on anodised discs after a metal tip, and Gianfreda et al. reported that anodised surfaces tended to lose the anodising layer.[31,32] A 2026 systematic review found no consistent pattern of roughness change on machined titanium across decontamination methods.[33]

Titanium release is quantified in three studies: all scaled SLA implants produced titanium particles in the coolant water, a metal tip released 34 µg of titanium at low and medium power with particle sizes near 1 µm and PEEK tips also contained titanium, and a conventional ultrasonic insert released 0.0047 ppm whereas an insert with a plastic sleeve released none.[21,22,5] Residual biofilm results vary: ultrasonic instrumentation left no residual bacteria on shot-blasted discs but deposited foreign material on 3% to 11% of the area, a PEEK tip reduced a multispecies biofilm on SLA implants, and PEEK and stainless steel tips removed less ink than air-polishing or a titanium brush in intraosseous defect models.[34,25,35] Stein et al. reported effective biofilm inactivation, re-exposure of surface elements and favourable gingival fibroblast cytocompatibility after a stainless steel ultrasonic scaler, Giannelli et al. reported preserved osteoblast biocompatibility with disc temperature below 47 °C, and Cao et al. reported reduced fibroblast proliferation on machined discs after metal and carbon fibre tips.[36,31,37] On zirconia, a stainless steel tip significantly increased roughness and left grey metallic residue, whereas a 2021 systematic review found minimal to no damage from non-metal tips.[38,39]


### Position in treatment protocols

Ultrasonic debridement is the conventional non-surgical arm in several comparisons: Renvert et al. found no group differences between titanium hand instruments and an ultrasonic device for peri-implantitis, Karring et al. found no significant difference between the Vector system and carbon fibre curettes, and Bengtsson et al. reported effective treatment of mucositis with either an Er:YAG laser or an ultrasonic scaler.[11,9,26] The 2015 meta-analysis by Schwarz et al. defined conventional non-surgical treatment as mechanical or ultrasonic debridement, and Verket et al. found no difference between glycine air-polishing and ultrasonic cleaning and no added effect of air-polishing over ultrasonics in mucositis.[40,41] In the Cochrane review by Grusovin et al. no statistically significant difference was found between a titanium curette and an ultrasonic debridement tool for mucositis.[42]

Ultrasonics also serve as the comparator or baseline in air-polishing trials and as the control arm against which chitosan brushes with antiseptics were added.[43,17,44] In surgery, plastic ultrasonic scalers with 3% hydrogen peroxide formed the control decontamination in a regenerative trial, PEEK-coated tips with erythritol air-flow were compared with plastic scalers and chlorhexidine, and in a dog model an ultrasonic device with chlorhexidine was compared with TiBrush.[14,15,45]


### Limitations and open questions as stated by the authors

Review authors describe the trials as small with short follow-up and the evidence as low quality, and conclude that no beneficial effect of one instrumentation over another could be demonstrated for mucositis.[42,46,41] Renvert et al. observed higher total bacterial counts immediately and at one week after ultrasonic treatment and no effect on probing depth, and Selimović et al. concluded that conventional ultrasonic and curette management produced limited clinical improvement.[11,12] Harrel et al. urged great caution with ultrasonic scalers around implants because every scaled implant released titanium particles, and Kao et al. and Romanos et al. raised the possible biological consequences of released titanium.[21,22,5] Sahrmann et al. noted that all ultrasonic instruments led to microscopic alterations of every surface tested, Colombo et al. called for study of material release from non-metallic inserts, and Louropoulou et al. stated that the clinical impact of in vitro cleaning findings requires clarification.[3,47,48]


### Sources cited in this description (48)

1. M F St J Mann et al. (2011). Effect of plastic‐covered ultrasonic scalers on titanium implant surfaces *Clinical Oral Implants Research*. https://doi.org/10.1111/j.1600-0501.2011.02186.x · in vitro
2. Francesco Faccioni et al. (2017). Ultrasonic instrument effects on different implant surfaces *ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/)*. https://doi.org/10.23805/jo.2017.09.01.06 · in vitro
3. Philipp Sahrmann et al. (2021). Assessment of implant surface and instrument insert changes due to instrumentation with different tips for ultrasonic-driven debridement *BMC Oral Health*. https://doi.org/10.1186/s12903-020-01384-0 · in vitro
4. Matys J et al. (2019). Temperature Changes and SEM Effects of Three Different Implants-Abutment Connection during Debridement with Er:YAG Laser: An Ex Vivo Study. *Materials (Basel)*. https://doi.org/10.3390/ma12223748 · in vitro
5. Romanos GE et al. (2026). Spectrometric Analysis of Titanium Particle Release Based on Various Implant Surface Detoxification Methods. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11375 · in vitro
6. Menini M et al. (2021). Efficacy of air-polishing devices without removal of implant-supported full-arch prostheses. *Int J Oral Implantol (Berl)*. https://pubmed.ncbi.nlm.nih.gov/34726849/ · RCT
7. Unursaikhan O et al. (2012). Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2012.42.3.88 · in vitro
8. Ziebolz D et al. (2017). Comparison of different maintenance strategies within supportive implant therapy for prevention of peri-implant inflammation during the first year after implant restoration. A randomized, dental hygiene practice-based multicenter study. *Am J Dent*. https://pubmed.ncbi.nlm.nih.gov/29178700/ · RCT
9. Karring ES et al. (2005). Treatment of peri-implantitis by the Vector system. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2005.01141.x · RCT
10. Fabiana Almeida Curylofo‐Zotti et al. (2014). instrumentation of dental implants: a literature review *RSBO*. https://doi.org/10.21726/rsbo.v10i1.900 · review
11. Renvert S et al. (2009). Mechanical non-surgical treatment of peri-implantitis: a double-blind randomized longitudinal clinical study. I: clinical results. *J Clin Periodontol*. https://doi.org/10.1111/j.1600-051X.2009.01421.x · RCT
12. Armin Selimović et al. (2023). Non-surgical treatment of peri-implantitis with and without erythritol air-polishing a 12-month randomized controlled trial *BMC Oral Health*. https://doi.org/10.1186/s12903-023-02973-5 · RCT
13. Aloy-Prósper A et al. (2020). Effect of a single initial phase of non-surgical treatment of peri-implantitis: Abrasive air polishing versus ultrasounds. A prospective randomized controlled clinical study. *J Clin Exp Dent*. https://doi.org/10.4317/jced.56653 · RCT
14. de Tapia B et al. (2019). The adjunctive effect of a titanium brush in implant surface decontamination at peri-implantitis surgical regenerative interventions: A randomized controlled clinical trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13095 · RCT
15. Oncu Elif (2019). Comparision Effectiveness of Two Different Implant Surface Decontamination Methods by Surgical Treatment of Periimplantitis: A Clinical Trial *Journal of Surgery and Surgical Research*. https://doi.org/10.17352/jssr.000062 · RCT
16. Fernando Luengo et al. (2022). Clinical, Microbiological, and Biochemical Impact of the Surgical Treatment of Peri-Implantitis—A Prospective Case Series *Journal of Clinical Medicine*. https://doi.org/10.3390/jcm11164699 · case report/series
17. Carolina Maiorani et al. (2025). Effectiveness of Erythritol-Based Air Polishing and Ultrasonic Instrumentation with PEEK Inserts in Peri-Implant Maintenance: A Randomized Clinical Trial Including Different Prosthetic Materials *Dentistry Journal*. https://doi.org/10.3390/dj13060235 · RCT
18. Tang C et al. (2025). Combining Glycine Powder Air-Polishing and Ultrasonic Scaling for Bone Regeneration Around Infected Dental Implants. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.70042 · in vitro
19. Munakata M et al. (2022). Effects of implant surface mechanical instrumentation methods on peri-implantitis: An in vitro study using a circumferential bone defect model. *J Dent Sci*. https://doi.org/10.1016/j.jds.2021.08.018 · in vitro
20. Peter Eickholz et al. (2022). Common practices of dental implants maintenance among dental hygiene professionals in Israel and Germany *International Journal of Dental Hygiene*. https://doi.org/10.1111/idh.12612 · clinical study
21. Harrel SK et al. (2019). Titanium particles generated during ultrasonic scaling of implants. *J Periodontol*. https://doi.org/10.1002/JPER.18-0230 · in vitro
22. Kao A et al. (2024). Quantity and Size of Titanium Particles Released from Different Mechanical Decontamination Procedures on Titanium Discs: An In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj12050123 · in vitro
23. Sirinirund B et al. (2019). Effects of Mechanical Instrumentation with Commercially Available Instruments Used in Supportive Peri-implant Therapy: An In Vitro Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.7409 · in vitro
24. Louisa Vierling et al. (2024). Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study *Dentistry Journal*. https://doi.org/10.3390/dj12050136 · in vitro
25. Khan SN et al. (2025). The Decontamination Effect of an Oscillating Chitosan Brush Compared With an Ultrasonic PEEK-Tip: An In Vitro Study Using a Dynamic Biofilm Model. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14360 · in vitro
26. Viveca Wallin Bengtsson et al. (2025). Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-025-00591-0 · RCT
27. Discepoli N et al. (2025). Influence of Emergence Angle and Mucosal Tunnel Depth on Artificial Biofilm Removal Around Dental Implants: An In Vitro Study. *Int J Dent*. https://doi.org/10.1155/ijod/7500003 · in vitro
28. Cha JK et al. (2019). The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13446 · in vitro
29. Kamel MS et al. (2026). Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70182 · in vitro
30. Qian Y et al. (2022). Cleaning effects of decontamination methods on clinically failed TiUnite implants and their impacts on surface roughness and chemistry: An in vitro pilot study. *Int J Oral Implantol (Berl)*. https://pubmed.ncbi.nlm.nih.gov/35546724/ · in vitro
31. Giannelli M et al. (2017). Effects of an Erbium:Yttrium-Aluminum-Garnet Laser and Ultrasonic Scaler on Titanium Dioxide-Coated Titanium Surfaces Contaminated With Subgingival Plaque: An In Vitro Study to Assess Post-Treatment Biocompatibility With Osteogenic Cells. *J Periodontol*. https://doi.org/10.1902/jop.2017.170195 · clinical study
32. Gianfreda F et al. (2022). The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Decontamination of 9 Implant-Abutment Surfaces: Scanning Electron Analysis and In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj10030036 · in vitro
33. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
34. Ichioka Y et al. (2022). Mechanical removal of biofilm on titanium discs: An in vitro study. *J Biomed Mater Res B Appl Biomater*. https://doi.org/10.1002/jbm.b.34978 · in vitro
35. Luengo F et al. (2022). In vitro effect of different implant decontamination methods in three intraosseous defect configurations. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13991 · in vitro
36. Stein JM et al. (2023). Antimicrobial efficiency and cytocompatibility of different decontamination methods on titanium and zirconium surfaces. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14014 · in vitro
37. Cao J et al. (2018). Influence on proliferation and adhesion of human gingival fibroblasts from different titanium surface decontamination treatments: An in vitro study. *Arch Oral Biol*. https://doi.org/10.1016/j.archoralbio.2017.12.013 · in vitro
38. Tan NCP et al. (2022). Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.486 · in vitro
39. Tan NCP et al. (2021). The effects of physical decontamination methods on zirconia implant surfaces: a systematic review. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2005080254 · systematic review
40. Frank Schwarz et al. (2015). Efficacy of alternative or adjunctive measures to conventional treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-015-0023-1 · systematic review
41. Verket A et al. (2023). Non-surgical therapy of peri-implant mucositis-Mechanical/physical approaches: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13789 · systematic review
42. Grusovin MG et al. (2010). Interventions for replacing missing teeth: maintaining and recovering soft tissue health around dental implants. *Cochrane Database Syst Rev*. https://doi.org/10.1002/14651858.CD003069.pub4 · systematic review
43. Shiai Dai et al. (2026). Non-surgical treatment of peri-implantitis with submarginal erythritol air-polishing in severe periodontitis patients: a randomized controlled trial *BMC Oral Health*. https://doi.org/10.1186/s12903-026-07721-z · RCT
44. Mayer Y et al. (2020). A nonsurgical treatment of peri-implantitis using mechanic, antiseptic and anti-inflammatory treatment: 1 year follow-up. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.286 · clinical study
45. Carral C et al. (2016). Mechanical and chemical implant decontamination in surgical peri-implantitis treatment: preclinical "in vivo" study. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12566 · animal study
46. Esposito M et al. (2008). The efficacy of interventions to treat peri-implantitis: a Cochrane systematic review of randomised controlled clinical trials. *Eur J Oral Implantol*. https://pubmed.ncbi.nlm.nih.gov/20467649/ · systematic review
47. Jacopo Colombo et al. (2025). Impact of Professional Hygiene Instruments on the Roughness of Implant Surfaces: An In Vitro Analysis *Applied Sciences*. https://doi.org/10.3390/app152312598 · in vitro
48. Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12224 · systematic review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

15 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “In patients with severe periodontitis, both non-surgical therapies were effective in improving clinical parameters of peri-implantitis. Erythritol air-polishing exhibited greater improvement in soft tissue inflammation. Adequate peri-implant keratinized mucosa and greater reduction in probing depth of adjacent teeth were identified as favorable prognostic factors for PPD.” — [Shiai Dai et al. 2026](https://doi.org/10.1186/s12903-026-07721-z), BMC Oral Health; cited 1.
- “Abrasive cleaning showed a transient increased trend in titanium concentration after non-surgical therapy, returning to baseline at 1 year after flap surgery. Overall, abrasive treatment produced inferior clinical outcomes and progressive bone loss in several cases, suggesting that abrasive cleaning is an adverse factor for regenerative treatment.” — [Kotsakis GA et al. 2026](https://doi.org/10.1002/jper.70158), J Periodontol; cited 0.
- “Treatment of peri-implant mucositis was effective regardless of whether the treatment was performed with an Er:YAG laser or an ultrasonic scaler. Fewer diseased sites were diagnosed at six months following laser treatment. TRIAL REGISTRATION: Registered at www. CLINICALTRIALS: gov : study no, NCT05772299.” — [Viveca Wallin Bengtsson et al. 2025](https://doi.org/10.1186/s40729-025-00591-0), International Journal of Implant Dentistry; cited 6.
- “Both erythritol-based air polishing and ultrasonic instrumentation with PEEK inserts are effective and comparable in the maintenance of peri-implant health. As treatment outcomes were independent of crown composition, the choice between modalities should be tailored to patient-specific needs and clinical conditions.” — [Carolina Maiorani et al. 2025](https://doi.org/10.3390/dj13060235), Dentistry Journal; cited 3.
- “Air polishing proved to be the most effective peri-implant mucosa cleaning protocol for reducing microbial biofilm formation, followed by ultrasonic cleaning. Manual brushing alone showed limited efficacy in controlling biofilm. Implementing efficient cleaning protocols is crucial for preventing peri-implant diseases and enhancing implant success.” — [Mukesh Soni et al. 2025](https://doi.org/10.4103/jpbs.jpbs_1923_24), Journal of Pharmacy And Bioallied Sciences; cited 0.
- “This study confirms that conventional non-surgical management of peri-implantitis produces limited clinical improvement. It is shown that an erythritol air-polishing system may not produce added clinical benefits when used adjunctive to conventional non-surgical management. In other words, neither approach effectively resolved peri-implantitis.” — [Armin Selimović et al. 2023](https://doi.org/10.1186/s12903-023-02973-5), BMC Oral Health; cited 28.
- “Glycine powder air polishing is a highly effective and comfortable treatment to maintain good oral hygiene in clinical practice, and could be used as an alternative to manual and mechanical instrumentation when dealing with implant-supported restorations.” — [Menini M et al. 2021](https://pubmed.ncbi.nlm.nih.gov/34726849/), Int J Oral Implantol (Berl).
- “An initial phase of non-surgical treatment achieves an improvement of the peri-implant clinical parameters, thought the method of debridement used seems not to influence. Key words:Peri-implantitis, peri-implant disease, non-surgical treatment, air-abrasive device, mechanical debridement.” — [Aloy-Prósper A et al. 2020](https://doi.org/10.4317/jced.56653), J Clin Exp Dent; cited 11.
- “The additional use of a titanium brush during regenerative treatment of peri-implantitis resulted in statistically significant benefits in terms of PPD reduction after 12 months.” — [de Tapia B et al. 2019](https://doi.org/10.1111/jcpe.13095), J Clin Periodontol; cited 118.
- “Modifying the contour of the prostheses to improve access for oral hygiene significantly improved the clinical outcomes after standard mechanical treatment of peri-implant mucositis.” — [de Tapia B et al. 2019](https://doi.org/10.1111/jcpe.13169), J Clin Periodontol; cited 92.

5 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

15 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.
- “Leave-one-out analysis confirmed the stability of the results. The findings highlight the need for future research with longer-term follow-up and high-quality, multi-center, large-sample RCTs.” — [Nengwen Huang et al. 2024](https://doi.org/10.1016/j.jdsr.2024.05.003), Japanese Dental Science Review; cited 18.
- “Available evidence on the efficacy of non-surgical submarginal peri-implant instrumentation with mechanical/physical decontamination is limited by the small number of controlled studies and the high heterogeneity of study protocols. Clinical and patient-reported benefits remain to be demonstrated.” — [Cosgarea R et al. 2023](https://doi.org/10.1111/jcpe.13762), J Clin Periodontol; cited 103.
- “Several mechanical/physical instrumentation procedures including curettes, ultrasonics, lasers, rotating brushes and air-polishing are documented; however, a beneficial effect over oral hygiene instructions alone or superiority over other procedures could not be demonstrated. Moreover, it remains unclear whether combinations of different procedures or their repetition over time may provide additional benefits.” — [Verket A et al. 2023](https://doi.org/10.1111/jcpe.13789), J Clin Periodontol; cited 62.
- “The standardized mean difference with a 95% confidence interval of the studied parameters was estimated using the random effect model; however, statistical differences were not detected between air polishing and comparative modalities in the treatment of peri-implantitis.” — [Bi J et al. 2023](https://doi.org/10.1563/aaid-joi-D-23-00114), J Oral Implantol; cited 7.

7 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

15 non-randomised clinical studies and 12 case reports or series.

- “Therapy reduced mucositis from 70% to 23%. Overall, while TNF-α levels alone may not conclusively differentiate between healthy and mucositis-affected sites in every context, they do appear to correlate with improvements in peri-implant health following therapeutic intervention.” — [Juliana Prazeres Gonçalves de Castro et al. 2025](https://doi.org/10.1590/0103-644020256205), Brazilian Dental Journal; cited 0.
- “The choice of decontamination method for the treatment of peri-implantitis should take into account the surface type and characteristics of the dental implant. The Er, Cr:YSGG laser proved to be a universal and effective method, while Air Flow and Vector Paro were more efficient when used for specific surface types.” — [Maksim V. Sokolov et al. 2025](https://doi.org/10.17116/rosstomat20251803126), Russian Journal of Stomatology; cited 0.
- “The obtained results underscore the necessity of selecting the surface treatment method according to the implant surface type to preserve its functional properties and ensure successful re-osseointegration.” — [Maksim V. Sokolov et al. 2025](https://doi.org/10.17116/rosstomat20251804132), Russian Journal of Stomatology; cited 0.
- “PDT as an adjunct to conventional peri-implantitis treatment with GBR resulted in statistically significantly lower PPD values. However, no additional benefits were observed for infection resolution, maintenance of infection-free status, MBL or BOP. Initial improvements in both groups followed by gradual recurrences in clinical parameters over 18 months.” — [Arısan V et al. 2025](https://doi.org/10.3290/j.ohpd.c_2078), Oral Health Prev Dent.
- “Thirty implants were enrolled and randomly assigned to test (GPAP) and control (ultrasonic device) groups. Significant differences were found in the mean of the clinical outcome evaluation but further observations of larger sample size of patients are needed.” — [Lucia Memè et al. 2024](https://doi.org/10.11138/oi16267-78), Oral & Implantology; cited 20.
- “: For the surgical treatment of peri-implantitis, reconstructive treatment involving mechanical debridement with ultrasonics and chemical decontamination, in addition to resolving peri-implant inflammation, allows for bone reconstruction around the implant. The use of multiple aids, both chemical and mechanical, for decontaminating the implant threads is key to achieving greater predictability in the procedure.” — [Giovanni Barbagallo et al. 2024](https://doi.org/10.29011/2575-9760.001984), Journal of Surgery; cited 2.

9 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

74 in vitro / ex vivo and 2 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “From this study, air polishing devices should be used with caution with titanium, PEEK, and zirconia; Prophy paste should be used with caution with titanium and lithium disilicate; and P5 scaler should be used with caution with zirconia. Further studies are required to study the clinical outcomes.” — [Pujarern P et al. 2026](https://doi.org/10.1055/s-0046-1818622), Eur J Dent; cited 1.
- “Ti ions and particles were found after instrumentation using SS curettes, Ti curettes, and CV ultrasonic inserts, which may affect the disease etiology and outcomes of peri-implantitis therapy more prominently compared to irradiation methods such as CS ultrasonic inserts, CO2 lasers, or ECY lasers.” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375), Int J Oral Maxillofac Implants; cited 1.
- “Er:YAG best preserved SLA microtopography but exhibited a lower debridement efficacy (3.27 ± 0.83) than mechanical methods. No method resulted in a pristine surface.” — [Yurdakul B et al. 2026](https://doi.org/10.3390/nano16120703), Nanomaterials (Basel); cited 1.
- “All mechanical instrumentation modalities altered titanium and zirconia surfaces to varying degrees. On titanium, EPAP was associated with a favourable combination of high cleaning efficacy and preserved native surface morphology. On zirconia, both air-polishing modalities achieved high cleaning efficacy with minimal topographical alteration.” — [Kamel MS et al. 2026](https://doi.org/10.1111/clr.70182), Clin Oral Implants Res; cited 0.
- “This difference was independent of defect type (p > 0.05). These findings indicate that electrochemical cleaning via galvanic current may be more effective, under in vitro conditions, for stain removal and surface decontamination; however, they also demonstrate that residual contamination could not be completely eliminated irrespective of the method.” — [Özay F et al. 2026](https://doi.org/10.3390/jfb17040166), J Funct Biomater; cited 0.
- “HIFU acoustic waves were uniquely able to penetrate a solid (glass) barrier and create localised biofilm-free regions. HIFU shows potential as a physical method for biofilm disruption; however, further studies - including multispecies, in vivo, and pre-clinical models - are required to evaluate its clinical applicability.” — [Tran MD et al. 2025](https://doi.org/10.1016/j.identj.2025.103905), Int Dent J; cited 4.

68 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “The results suggest that PDT and OFD have significant benefits in peri-implantitis treatment by reducing bacterial count. The presence of bacterial complex with different response to therapeutic modality suggests the use of combined decontamination methods for peri-implantitis treatment.” — [Madi M et al. 2018](https://doi.org/10.1155/2018/7570105), Biomed Res Int; cited 28.
- “Resolution of peri-implantitis after access surgery and decontamination of peri-implant surfaces with TiBrush(™) with or without sodium hypochlorite is possible. However, the concomitant use of sodium hypochlorite has minor effect on treatment outcomes.” — [Carral C et al. 2016](https://doi.org/10.1111/jcpe.12566), J Clin Periodontol; cited 42.


## Parameters as stated in the abstracts

- “Mechanical decontamination was performed for 120 s using either an OCB or a US-PEEK.” — [Khan SN et al. 2025](https://doi.org/10.1111/clr.14360) (in vitro).
- “Erythritol powder, PEEK ultrasonic tips, and titanium curettes were applied for 2 min in Class 1A defects and 3 minutes in Class 1B defects.” — [Ozgu I et al. 2025](https://doi.org/10.3791/67778) (in vitro).
- “All underwent clinical and radiographic exams and received non-invasive therapy (mechanical debridement, with ultrasonic scalers to remove calculus and sodium air-abrasive polishing to eliminate soft debris from the implant and prosthetic components + 0.12% chlorhexidine).” — [Juliana Prazeres Gonçalves de Castro et al. 2025](https://doi.org/10.1590/0103-644020256205) (clinical study).
- “The Er,Cr:YSGG laser irradiation with the 40 Hz group showed a significantly higher attached fibroblast cell numbers than the titanium scaler group at 72 h after treatment (p = 0.023).” — [Shiba T et al. 2024](https://doi.org/10.3390/ma17194899) (in vitro).
- “Decontamination of implant threads, was carried out using ultrasonic instruments and 24% EDTA.” — [Giovanni Barbagallo et al. 2024](https://doi.org/10.29011/2575-9760.001984) (clinical study).
- “Decontaminations were performed using titanium curette, stainless steel ultrasonic scaler (US), glycine (GPAP) and erythritol (EPAP) powder air-polishing, Er:YAG laser, 1% chlorhexidine (CHX), 10% povidone-iodine (PVI), 14% doxycycline (doxy), and 0.95% NaOCl solution.” — [Stein JM et al. 2023](https://doi.org/10.1111/clr.14014) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Piezon** — 9 entries
- **Air-Flow** — 5 entries
- **AIRFLOW** — 4 entries
- **Perisolv** — 3 entries
- **Waterlase** — 3 entries
- **Perio-Flow** — 2 entries
- **GalvoSurge** — 2 entries
- **Cavitron** — 2 entries
- **Vector** — 2 entries
- **PIEZON** — 1 entry
- **LightWalker** — 1 entry
- **AirFlow** — 1 entry
- **EMS Air-Flow** — 1 entry
- **TiBrush** — 1 entry

Manufacturers: EMS (17), Straumann (7), Geistlich (5), Biolase (4), Dentium (4), Hu-Friedy (4), Dentsply Sirona (3), Acteon (3), Fotona (3), Nobel Biocare (3), Dentsply (3), Satelec (3), Neobiotech (2), KaVo (2), Zimmer Biomet (2), Sirona (2), Zimmer (2), Astra Tech (1), Thommen (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (19 different): chlorhexidine (34), saline (25), hydrogen peroxide (19), antibiotics (systemic) (11), citric acid (11), tetracycline (9), amoxicillin (7), photosensitizer dye (7), sodium hypochlorite (7), sterile water (6), minocycline (5), metronidazole (4), doxycycline (4), Perisolv (3), EDTA (3), chloramine (2), enamel matrix derivative (2), povidone-iodine (2), phosphoric acid / etching gel (2). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (148)

The 148 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [7. Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/)
- Next: [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)


---

# 9. Curettes and hand instruments

Chapter 9 of an evidence-based reader on implant surface decontamination in peri-implantitis: 156 entries on curettes and hand instruments — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about titanium, plastic and carbon-fibre curettes on the implant surface?

**Key facts — Curettes and hand instruments**

- Entries in this chapter: 156 of 819 (2004–2026): RCT 26 · clinical study 21 · case report/series 24 · systematic review 13 · review 12 · in vitro 54 · animal study 2 · not classified 4
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Figuero E et al. 2014](https://doi.org/10.1111/prd.12049) (521); [Bassetti M et al. 2014](https://doi.org/10.1111/clr.12155) (312)
- Products named by the authors: Air-Flow (7), Perio-Flow (5), Piezon (4), Ti-Brush (4), i-Brush (4), TiBrush (3), Waterlase (2), Cavitron (2), AIRFLOW (2), Vector (2)
- Manufacturers named by the authors: EMS (17), Straumann (13), Hu-Friedy (10), Geistlich (7), Biolase (6), Nobel Biocare (5), Dentsply (5), Dentium (4), KaVo (4), Zimmer Biomet (3)
- Chemical agents used alongside: chlorhexidine (42), saline (40), hydrogen peroxide (22), amoxicillin (18), tetracycline (15), antibiotics (systemic) (14), metronidazole (12), citric acid (10)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (81), [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) (71), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (59), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (56)
- Entries naming the NiTi Brush: 2 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Hand instruments — stainless-steel, titanium, plastic, carbon-fibre or Teflon curettes and scalers — used to remove deposits from the implant surface. The laboratory literature compares the surface alteration and cleaning efficiency of the different tip materials; clinically they are usually one step of a wider protocol.


### Mechanism and use, as the papers describe it

Hand instruments in the publications in this chapter are curettes and scalers with working ends of stainless steel, titanium or titanium coating, plastic, carbon fibre, graphite or Teflon, used to remove soft and hard deposits from the implant surface.[1,2,3,4,5] Gracey curettes appear in laboratory models; in the entries that name polyetheretherketone (PEEK), it is an ultrasonic tip material.[6,7,8,9]

In non-surgical treatment, titanium curettes are used for submarginal instrumentation, carbon fibre curettes for submucosal debridement, and plastic curettes together with a plastic-tipped ultrasonic device.[10,11,12,13] A 2026 narrative review describes flapless submucosal instrumentation as combining submarginal instrumentation with deliberate degranulation or curettage.[14] A survey of dentists in Türkiye found that titanium curettes were commonly preferred for mechanical debridement.[15]

In surgical case reports, threads were cleaned with a plastic curette after flap elevation, soft tissue was curetted with titanium or plastic curettes before titanium brushing, and granulation tissue was removed with stainless steel hand instruments.[16,17,18,19] Fu et al. preferred stiff instruments over plastic curettes for adherent granular tissue and calculus, whereas Solakoğlu et al. used graphite hand instruments only to remove granulation tissue.[19,4]


### Reported operating conditions

Laboratory abstracts state instrumentation times of 2 min per implant, 2 min in Class 1A and 3 min in Class 1B defects, and 120 s.[20,21,22,8,6] Other protocols applied 20 or 100 strokes to simulate repeated maintenance, 20 strokes in 40 s or 100 strokes in 200 s to simulate one or five years of supportive care, or instrumented until the surface was visibly clean.[23,24] Mean treatment times of 303.5 s for steel and 126.4 s for plastic curettes are reported, and Hakki et al. recorded higher implant temperature after hand instrumentation than after the other methods tested.[25,26,27]

Curettes are combined with glycine powder air-polishing, 0.2% chlorhexidine irrigation, cotton pellets and sterile saline, or 24% ethylenediaminetetraacetic acid gel.[28,29,30,31,32] In one multicentre trial, titanium curette debridement was repeated at 3, 6 and 9 months where bleeding and probing depths of 4 mm or more persisted.[33]


### Effects on the implant surface reported in laboratory studies

A 2025 systematic review of nonclinical studies reported that titanium or stainless steel curettes induced significant surface alterations and peak flattening of threads, and that plastic and carbon curettes left material remnants.[9] Sirinirund et al. observed that rough surfaces became less rough and machined surfaces rougher, with plastic- and titanium-like remnants after plastic, stainless steel and titanium curettes.[24] Lang et al. found the highest mean roughness after the titanium curette and rotary titanium brush and the lowest after the plastic curette, with no cumulative change from repeated strokes.[23] Titanium curettes altered the micro-texture of SLA implants and caused moderate to severe damage in an intraosseous defect model, and metallic instruments produced scratching, gouging and material loss on titanium abutments.[34,8,35] On zirconia, titanium curettes left grey metallic residue while plastic curettes caused minimal alteration, and on anatase nanocoatings plastic instruments left the surface intact.[36,37] A 2026 systematic review found no consistent roughness pattern on machined titanium.[38]

In ink-stained defect models, curettes left 48% to 57%, 62% to 67% and 74.7% of the surface uncleaned, and apically facing threads retained the most stain regardless of instrument.[20,21,6,39] Residual biofilm covered 20.1% of discs after a carbon fibre curet against 74.0% in controls, whereas a plastic curette did not reduce Streptococcus gordonii biomass.[40,41] A 2014 systematic review found non-metal curettes ineffective and reported positive results for metal curettes on SLA surfaces.[42] Romanos et al. detected titanium ions and particles after stainless steel and titanium curettes.[43] Plastic curettes gave the highest fibroblast counts on titanium discs in one study, whereas curette-treated surfaces showed lower fibroblast viability in another and a stainless steel curette decreased fibroblast proliferation on machined surfaces in a third.[23,44,45]


### Position in treatment protocols

Titanium curettes are the control arm in several non-surgical trials: Khan et al. found no statistically significant difference from an oscillating chitosan brush at 6 and 12 months, Clementini et al. found no intergroup differences in bleeding reduction when air-polishing or Er:YAG laser was added, and Koldsland et al. found no significant difference in post-surgical supportive treatment.[11,33,10,46] Wohlfahrt et al. reported greater bleeding improvement with a chitosan brush at 2 and 4 weeks, and Daubert et al. reported significant probing depth reduction with rotary polymer microbrushes but not with titanium curettes.[47,48] Karring et al. found no significant difference between carbon fibre curettes and the Vector system, and Grusovin et al. found none between a titanium curette and an ultrasonic tool.[12,49]

Curettes also form the shared mechanical step to which photodynamic therapy, local drugs, lasers or air-polishing were added, and they appear in maintenance regimens.[50,51,52,53] In surgery, Toma et al. reported less bone loss at six months with a titanium brush than with plastic curettes, Schwarz et al. reported similar 7-year outcomes for plastic curettes with cotton pellets and for an Er:YAG laser, and a network meta-analysis concluded that implantoplasty improved probing depth more than hand curettes.[54,31,55]


### Limitations and open questions as stated by the authors

Grusovin et al. described the evidence as low quality with short follow-up, and Verket et al. concluded that a beneficial effect over oral hygiene instruction alone, or over other procedures, could not be demonstrated.[49,56] Khan et al. found persistent inflammation common and eradication not predictable, and Koldsland et al. pointed to the need for more effective submucosal cleaning after surgery.[33,11,46] Laboratory studies and a systematic review of laboratory studies reported that no method cleaned the implant completely, that heterogeneity precluded statistical analysis, that no universally safe tool could be identified, and that released titanium may affect disease aetiology.[21,42,38,43] Solakoğlu et al. noted that even plastic or graphite scalers could slightly damage implant surfaces.[4]


### Sources cited in this description (56)

1. Fabiana Almeida Curylofo‐Zotti et al. (2014). instrumentation of dental implants: a literature review *RSBO*. https://doi.org/10.21726/rsbo.v10i1.900 · review
2. Parlak HM et al. (2026). \[Composition of Submucosal Microbiota and Non-Surgical Management of Peri-Implant Diseases\]. *Mikrobiyol Bul*. https://doi.org/10.5578/mb.20260299 · review
3. Santhosh Kumar et al. (2024). Evaluation of the Loss of Surface Roughness Following the Use of Four Different Instruments for Mechanical Debridement of Dental Implants: An In-vitro Pilot Study *Journal of Bio- and Tribo-Corrosion*. https://doi.org/10.1007/s40735-024-00881-x · in vitro
4. Önder Solakoğlu et al. (2018). Regenerative Therapy of Peri-Implantitis: Clinical and Radiologic Documentation of 16 Consecutive Patients With a Mean Follow-Up of 3 Years *Journal of Oral Implantology*. https://doi.org/10.1563/aaid-joi-d-18-00168 · clinical study
5. Vasu Masalawalla et al. (2022). A novel approach to treat peri-implantitis using sticky bone: A case report *International Journal of Health Sciences*. https://doi.org/10.53730/ijhs.v6ns3.5685 · case report/series
6. Ronay V et al. (2017). In vitro cleaning potential of three implant debridement methods. Simulation of the non-surgical approach. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12773 · in vitro
7. Giffi R et al. (2023). The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2203500175 · in vitro
8. Ozgu I et al. (2025). Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness. *J Vis Exp*. https://doi.org/10.3791/67778 · in vitro
9. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
10. Clementini M et al. (2026). Evaluation of the Adjunctive Use of Er:YAG Laser or Erythritol Air-Polishing in the Non-Surgical Treatment of Peri-Implantitis: A Pilot RCT. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70153 · RCT
11. Khan SN et al. (2022). Non-surgical treatment of mild to moderate peri-implantitis using an oscillating chitosan brush or a titanium curette-A randomized multicentre controlled clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14007 · RCT
12. Karring ES et al. (2005). Treatment of peri-implantitis by the Vector system. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2005.01141.x · RCT
13. de Tapia B et al. (2019). Adjunctive effect of modifying the implant-supported prosthesis in the treatment of peri-implant mucositis. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13169 · RCT
14. Nart J et al. (2026). Flapless submucosal instrumentation treatment of peri-implantitis: Contemporary evidence and clinical protocol. *Periodontol 2000*. https://doi.org/10.1111/prd.70091 · review
15. Fatih Karaaslan et al. (2026). Knowledge and Clinical Practices of Dentists in Türkiye Regarding Peri-Implantitis: A Cross-Sectional Study *Journal of Dental Health and Oral Research*. https://doi.org/10.46889/jdhor.2026.7121 · clinical study
16. Marcos Ribeiro Sallé et al. (2023). Decontamination and Repair Protocol Promotes Positive Outcomes in Implants Affected by Peri-implantitis: A Human Case Series *The International Journal of Periodontics & Restorative Dentistry*. https://doi.org/10.11607/prd.5534 · case report/series
17. Neely AL et al. (2020). Successful Management of Peri-Implantitis Using a Titanium Brush and a Doxycycline-Saline Slurry for Surface Detoxification With Guided Bone Regeneration: A 5-Year Follow-Up. *Clin Adv Periodontics*. https://doi.org/10.1002/cap.10085 · case report/series
18. Badarudhin BBK et al. (2026). Three-year follow-up of a peri-implantitis case managed by titanium brush and tetracycline slurry for surface decontamination with guided bone regeneration. *J Indian Soc Periodontol*. https://doi.org/10.4103/jisp.jisp_395_24 · case report/series
19. Po‐Sung Fu et al. (2014). Surgical Management of Severe Peri-Implantitis in the Esthetic Zone: A Case Report With a 6-Year Follow-Up *Journal of Oral Implantology*. https://doi.org/10.1563/aaid-joi-d-13-00160 · case report/series
20. Keim D et al. (2019). In vitro efficacy of three different implant surface decontamination methods in three different defect configurations. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13441 · in vitro
21. Iatrou P et al. (2021). In Vitro Efficacy of Three Different Nonsurgical Implant Surface Decontamination Methods in Three Different Defect Configurations. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.8864 · in vitro
22. Ince Kuka G et al. (2025). Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces. *J Vis Exp*. https://doi.org/10.3791/69521 · in vitro
23. Lang MS et al. (2016). Cell Attachment Following Instrumentation with Titanium and Plastic Instruments, Diode Laser, and Titanium Brush on Titanium, Titanium-Zirconium, and Zirconia Surfaces. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.4440 · in vitro
24. Sirinirund B et al. (2019). Effects of Mechanical Instrumentation with Commercially Available Instruments Used in Supportive Peri-implant Therapy: An In Vitro Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.7409 · in vitro
25. John G et al. (2014). Rotating titanium brush for plaque removal from rough titanium surfaces--an in vitro study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12147 · in vitro
26. Park SH et al. (2020). Effect of a Er, Cr:YSGG laser and a Er:YAG laser treatment on oral biofilm-contaminated titanium. *J Appl Oral Sci*. https://doi.org/10.1590/1678-7757-2020-0528 · in vitro
27. Hakki SS et al. (2017). The effect of different cleaning methods on the surface and temperature of failed titanium implants: an in vitro study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-017-2149-2 · in vitro
28. Bassetti M et al. (2014). Anti-infective therapy of peri-implantitis with adjunctive local drug delivery or photodynamic therapy: 12-month outcomes of a randomized controlled clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12155 · RCT
29. Curcio J et al. (2026). Efficacy of Xanthan-Based Chlorhexidine Gel in Peri-Implant Mucositis Treatment: A Split-Mouth Randomized Clinical Trial. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.70137 · RCT
30. Sun F et al. (2022). Shift in the submucosal microbiome of diseased peri-implant sites after non-surgical mechanical debridement treatment. *Front Cell Infect Microbiol*. https://doi.org/10.3389/fcimb.2022.1091938 · clinical study
31. Schwarz F et al. (2017). Combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination: a 7-year follow-up observation. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12648 · RCT
32. Wohlfahrt JC et al. (2012). Porous titanium granules in the surgical treatment of peri-implant osseous defects: a randomized clinical trial. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/22442781/ · RCT
33. Khan SN et al. (2023). Non-surgical treatment of mild to moderate peri-implantitis with an oscillating chitosan brush or a titanium curette-12-month follow-up of a multicenter randomized clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14078 · RCT
34. Larsen OI et al. (2017). Antimicrobial Effects of Three Different Treatment Modalities on Dental Implant Surfaces. *J Oral Implantol*. https://doi.org/10.1563/aaid-joi-D-16-00147 · not classified
35. Kamel MS et al. (2026). Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70182 · in vitro
36. Tan NCP et al. (2022). Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.486 · in vitro
37. Kister F et al. (2017). Peri-implantitis cleaning instrumentation influences the integrity of photoactive nanocoatings. *Dent Mater*. https://doi.org/10.1016/j.dental.2016.10.002 · in vitro
38. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
39. Steiger-Ronay V et al. (2017). Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy. *BMC Oral Health*. https://doi.org/10.1186/s12903-017-0428-8 · in vitro
40. AlMoharib HS et al. (2021). Efficacy of an Er:YAG laser in the decontamination of dental implant surfaces: An in vitro study. *J Periodontol*. https://doi.org/10.1002/JPER.20-0765 · RCT
41. Toma S et al. (2018). In Vitro Comparison of the Efficacy of Peri-Implantitis Treatments on the Removal and Recolonization of Streptococcus gordonii Biofilm on Titanium Disks. *Materials (Basel)*. https://doi.org/10.3390/ma11122484 · in vitro
42. Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12224 · systematic review
43. Romanos GE et al. (2026). Spectrometric Analysis of Titanium Particle Release Based on Various Implant Surface Detoxification Methods. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11375 · in vitro
44. Jazaeri MS et al. (2026). Biofilm removal capacity and titanium surface integrity in non-abrasive versus abrasive peri-implantitis cleaning interventions. *J Periodontol*. https://doi.org/10.1002/jper.11371 · in vitro
45. Cao J et al. (2018). Influence on proliferation and adhesion of human gingival fibroblasts from different titanium surface decontamination treatments: An in vitro study. *Arch Oral Biol*. https://doi.org/10.1016/j.archoralbio.2017.12.013 · in vitro
46. Koldsland OC et al. (2020). Supportive treatment following peri-implantitis surgery: An RCT using titanium curettes or chitosan brushes. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13357 · RCT
47. Wohlfahrt JC et al. (2019). Treatment of peri-implant mucositis with a chitosan brush-A pilot randomized clinical trial. *Int J Dent Hyg*. https://doi.org/10.1111/idh.12381 · RCT
48. Daubert D et al. (2023). Assessment of titanium release following non-surgical peri-implantitis treatment: A randomized clinical trial. *J Periodontol*. https://doi.org/10.1002/JPER.22-0716 · RCT
49. Grusovin MG et al. (2010). Interventions for replacing missing teeth: maintaining and recovering soft tissue health around dental implants. *Cochrane Database Syst Rev*. https://doi.org/10.1002/14651858.CD003069.pub4 · systematic review
50. Schär D et al. (2013). Anti-infective therapy of peri-implantitis with adjunctive local drug delivery or photodynamic therapy: six-month outcomes of a prospective randomized clinical trial. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2012.02494.x · RCT
51. Altindal D et al. (2023). Evaluation of the effectiveness of diode laser therapy in conjunction with nonsurgical treatment of peri-implantitis. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2203140157 · RCT
52. Aloy-Prósper A et al. (2020). Effect of a single initial phase of non-surgical treatment of peri-implantitis: Abrasive air polishing versus ultrasounds. A prospective randomized controlled clinical study. *J Clin Exp Dent*. https://doi.org/10.4317/jced.56653 · RCT
53. Ziebolz D et al. (2017). Comparison of different maintenance strategies within supportive implant therapy for prevention of peri-implant inflammation during the first year after implant restoration. A randomized, dental hygiene practice-based multicenter study. *Am J Dent*. https://pubmed.ncbi.nlm.nih.gov/29178700/ · RCT
54. Toma S et al. (2019). Clinical Evaluation of Three Surgical Modalities in the Treatment of Peri-Implantitis: A Randomized Controlled Clinical Trial. *J Clin Med*. https://doi.org/10.3390/jcm8070966 · RCT
55. Zhi-Bang Li et al. (2022). The Effect of Nonaugmentative Approaches in the Surgical Treatment of Peri-implantitis: A Systematic Review and Network Meta-analysis *The International Journal of Oral & Maxillofacial Implants*. https://doi.org/10.11607/jomi.9211 · systematic review
56. Verket A et al. (2023). Non-surgical therapy of peri-implant mucositis-Mechanical/physical approaches: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13789 · systematic review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

26 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Irrespective of the adjunctive treatment modality, achievement of peri-implantitis therapeutic endpoint was limited across groups. Possible associations with treatment outcomes were observed; these findings require confirmation in larger studies.” — [Clementini M et al. 2026](https://doi.org/10.1111/clr.70153), Clin Oral Implants Res; cited 2.
- “The adjunctive use of XanCHX gel did not result in any statistically significant clinical benefit compared to PMPR alone in the treatment of PM up to 6 months, despite the reported clinical positive effects within the first month after treatment.” — [Curcio J et al. 2026](https://doi.org/10.1111/cid.70137), Clin Implant Dent Relat Res; cited 2.
- “Peri-implantitis treated non-surgically with implant-specific instruments (Imp group) had a significantly greater decrease in probing depth versus the Mech treatment group. This improvement was linked with a trend for less Ti release to the peri-implant plaque by the non-abrasive treatment.” — [Daubert D et al. 2023](https://doi.org/10.1002/JPER.22-0716), J Periodontol; cited 30.
- “This study confirms that conventional non-surgical management of peri-implantitis produces limited clinical improvement. It is shown that an erythritol air-polishing system may not produce added clinical benefits when used adjunctive to conventional non-surgical management. In other words, neither approach effectively resolved peri-implantitis.” — [Armin Selimović et al. 2023](https://doi.org/10.1186/s12903-023-02973-5), BMC Oral Health; cited 28.
- “Within the limitations of this 12-month multicenter randomized clinical trial, non-surgical treatment of peri-implantitis with OCB or TC showed no statistically significant differences between the groups. Clinical improvements and, in some cases, disease resolution, was observed in both groups. However, persistent inflammation was a common finding which further puts emphasis on the need for further treatment.” — [Khan SN et al. 2023](https://doi.org/10.1111/clr.14078), Clin Oral Implants Res; cited 26.
- “The diode laser enabled improvements in clinical parameters in the peri-implant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.” — [Altindal D et al. 2023](https://doi.org/10.5051/jpis.2203140157), J Periodontal Implant Sci; cited 18.
- “The additional application of amino acid buffered hypochlorite solution seemed to improve the effectiveness of implant surface decontamination with air-powder abrasion following open-flap surgery.” — [La Monaca G et al. 2023](https://doi.org/10.1007/s00784-022-04608-5), Clin Oral Investig; cited 4.
- “Within the limitations of this six-month multicentre clinical trial, non-surgical treatment of peri-implantitis with OCB and TC showed no difference between the interventions. Eradication of disease was not predictable for any of the groups.” — [Khan SN et al. 2022](https://doi.org/10.1111/clr.14007), Clin Oral Implants Res; cited 27.
- “Both treatment procedures could relieve the inflammation of peri-implant soft tissue. Non-surgical mechanical submucosal debridement combined application of glycine powder air-polishing is associated with significant reduction of soft tissue bleeding and suppuration on probing especially in the implants diagnosed with peri-implant mucositis.” — [Sun F et al. 2022](https://doi.org/10.19723/j.issn.1671-167X.2022.01.019), Beijing Da Xue Xue Bao Yi Xue Ban; cited 4.
- “Er:YAG laser treatment is an effective method for reducing the bacterial biofilm on titanium discs. However, on a threadless titanium surface, Er:YAG laser does not exhibit a significantly greater efficacy in biofilm removal than commonly used titanium brushes or carbon fiber curets.” — [AlMoharib HS et al. 2021](https://doi.org/10.1002/JPER.20-0765), J Periodontol; cited 32.

16 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

13 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.
- “Several mechanical/physical instrumentation procedures including curettes, ultrasonics, lasers, rotating brushes and air-polishing are documented; however, a beneficial effect over oral hygiene instructions alone or superiority over other procedures could not be demonstrated. Moreover, it remains unclear whether combinations of different procedures or their repetition over time may provide additional benefits.” — [Verket A et al. 2023](https://doi.org/10.1111/jcpe.13789), J Clin Periodontol; cited 62.
- “Within the limitations of this systematic review and NMA, implantoplasty is more effective than hand curettes in improving PD in the surgical treatment of peri-implantitis. Chemical antiseptics or systemic antibiotics have a limited effect on improving PD and MBL.” — [Zhi-Bang Li et al. 2022](https://doi.org/10.11607/jomi.9211), The International Journal of Oral & Maxillofacial Implants; cited 5.
- “titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.” — [González FJ et al. 2021](https://doi.org/10.3390/dj9080084), Dent J (Basel); cited 18.
- “Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution.” — [Tan NCP et al. 2021](https://doi.org/10.5051/jpis.2005080254), J Periodontal Implant Sci; cited 17.

5 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

21 non-randomised clinical studies and 24 case reports or series.

- “Within the limitations of the study design, non-surgical approach with adjunctive use of systemic azithromycin for the treatment of peri-implantitis associated lesions with intrabony defects may lead to significant clinical and radiographic improvements.” — [Leira Y et al. 2026](https://doi.org/10.11607/jomi.11673), Int J Oral Maxillofac Implants; cited 1.
- “Two isolates, M29 and P30 strains, were identified as Streptococcus salivarius by 16S rRNA sequencing. Our findings reveal emerging resistance to amoxicillin and metronidazole in clinical isolates from implants with peri-implant infections, yet bacterial susceptibility to clindamycin remains.” — [Secundino I et al. 2026](https://doi.org/10.1099/acmi.0.000946.v3), Access Microbiol; cited 1.
- “Within the limitations of this retrospective study, both electrolytic and conventional mechanical implant surface decontamination protocols resulted in significant short-term clinical and radiographic improvements following peri-implantitis surgery. Electrolytic cleaning demonstrated outcomes comparable to conventional therapy and may represent a viable alternative for implant surface decontamination.” — [De Angelis N et al. 2026](https://doi.org/10.3390/dj14070447), Dent J (Basel); cited 0.
- “Marked variability exists in dentists’ knowledge and peri-implantitis management practices in Türkiye, particularly among general practitioners and prosthodontists. Standardized diagnostic protocols and structured continuing professional education programs are needed to enhance clinical decision-making and improve long-term implant outcomes.” — [Fatih Karaaslan et al. 2026](https://doi.org/10.46889/jdhor.2026.7121), Journal of Dental Health and Oral Research; cited 0.
- “Effective therapy for early peri-implantitis is systemic treatment of peri-implantitis with antibiotics, antiseptic treatment of peri-implant pockets and local application of "Armenicum" paste has shown its effectiveness and can prevent further development of peri-implantitis.” — [Viktoria Margaryan et al. 2025](https://doi.org/10.33425/2639-9490.1161), Oral Health & Dental Science; cited 0.
- “PDT as an adjunct to conventional peri-implantitis treatment with GBR resulted in statistically significantly lower PPD values. However, no additional benefits were observed for infection resolution, maintenance of infection-free status, MBL or BOP. Initial improvements in both groups followed by gradual recurrences in clinical parameters over 18 months.” — [Arısan V et al. 2025](https://doi.org/10.3290/j.ohpd.c_2078), Oral Health Prev Dent.

15 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

54 in vitro / ex vivo and 2 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “Non-abrasive waterjet cleaning is a superior method for the clinical treatment of peri-implantitis biofilms versus mechanical abrasive cleaning while maintaining titanium implant surface properties necessary for reintegration with peri-implant tissue.” — [Jazaeri MS et al. 2026](https://doi.org/10.1002/jper.11371), J Periodontol; cited 2.
- “Ti ions and particles were found after instrumentation using SS curettes, Ti curettes, and CV ultrasonic inserts, which may affect the disease etiology and outcomes of peri-implantitis therapy more prominently compared to irradiation methods such as CS ultrasonic inserts, CO2 lasers, or ECY lasers.” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375), Int J Oral Maxillofac Implants; cited 1.
- “Er:YAG best preserved SLA microtopography but exhibited a lower debridement efficacy (3.27 ± 0.83) than mechanical methods. No method resulted in a pristine surface.” — [Yurdakul B et al. 2026](https://doi.org/10.3390/nano16120703), Nanomaterials (Basel); cited 1.
- “All mechanical instrumentation modalities altered titanium and zirconia surfaces to varying degrees. On titanium, EPAP was associated with a favourable combination of high cleaning efficacy and preserved native surface morphology. On zirconia, both air-polishing modalities achieved high cleaning efficacy with minimal topographical alteration.” — [Kamel MS et al. 2026](https://doi.org/10.1111/clr.70182), Clin Oral Implants Res; cited 0.
- “In this In Vitro study no statistically significant influence of STT on the efficacy of surface decontamination could be detected. Treatment method, defect angle and approach were confirmed as predictors for the cleaning efficacy.” — [Rahner A et al. 2025](https://doi.org/10.1111/clr.14415), Clin Oral Implants Res; cited 3.
- “Er:YAG laser and water mist Nd:YAG laser will not have any adverse effects on the surface morphology, roughness and temperature changes of pure titanium and zirconia sheets. The laser is safer to use and can efficiently remove the material surface. Er:YAG laser and water mist Nd:YAG laser irradiation can increase the proportion of dead bacteria in reattached plaque.” — [Ai H et al. 2025](https://doi.org/10.1186/s12903-025-07332-0), BMC Oral Health; cited 2.

48 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “All treatments resulted in partial regeneration of the defects. No treatment group showed a significantly (p < 0.05) better outcome. However, pretreatment with air polishing showed a tendency for less inflammation. Noteworthy, inflammation assessment showed an overall irritative potential after GBR in the evaluated early healing phase.” — [Alex Solderer et al. 2020](https://doi.org/10.1007/s00784-020-03572-2), Clinical Oral Investigations; cited 10.
- “The results suggest that PDT and OFD have significant benefits in peri-implantitis treatment by reducing bacterial count. The presence of bacterial complex with different response to therapeutic modality suggests the use of combined decontamination methods for peri-implantitis treatment.” — [Madi M et al. 2018](https://doi.org/10.1155/2018/7570105), Biomed Res Int; cited 28.


## Parameters as stated in the abstracts

- “All of them received non-surgical treatment consisting of submucosal debridement, implant surface decontamination, minor curettage together with submucosal irrigation with 0.12% chlorhexidine digluconate and with the administration of systemic azithromycin (500 mg/day for 3 days).” — [Leira Y et al. 2026](https://doi.org/10.11607/jomi.11673) (clinical study).
- “Erythritol powder, PEEK ultrasonic tips, and titanium curettes were applied for 2 min in Class 1A defects and 3 minutes in Class 1B defects.” — [Ozgu I et al. 2025](https://doi.org/10.3791/67778) (in vitro).
- “Surface decontamination was performed for 2 min by the same examiner using one of the following devices: titanium brush (TiB), chitosan brush (ChB), or titanium curette (TiC).” — [Ince Kuka G et al. 2025](https://doi.org/10.3791/69521) (in vitro).
- “Decontaminations were performed using titanium curette, stainless steel ultrasonic scaler (US), glycine (GPAP) and erythritol (EPAP) powder air-polishing, Er:YAG laser, 1% chlorhexidine (CHX), 10% povidone-iodine (PVI), 14% doxycycline (doxy), and 0.95% NaOCl solution.” — [Stein JM et al. 2023](https://doi.org/10.1111/clr.14014) (in vitro).
- “Diode laser, Ti brush, and Ti curette treatments were performed on the Grade 4 Ti discs, with/without treatment with 3% H2O2 solution or 0.2% CHX.” — [Bayrak M et al. 2022](https://doi.org/10.3390/nano12244481) (in vitro).
- “After degranulation, implant surface was rinsed with 10% povidone iodine for 10 minutes.” — [Vasu Masalawalla et al. 2022](https://doi.org/10.53730/ijhs.v6ns3.5685) (case report/series).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Air-Flow** — 7 entries
- **Perio-Flow** — 5 entries
- **Piezon** — 4 entries
- **Ti-Brush** — 4 entries
- **i-Brush** — 4 entries
- **TiBrush** — 3 entries
- **Waterlase** — 2 entries
- **Cavitron** — 2 entries
- **AIRFLOW** — 2 entries
- **Vector** — 2 entries
- **PerioFlow** — 1 entry
- **Perisolv** — 1 entry
- **LightWalker** — 1 entry
- **GalvoSurge** — 1 entry
- **AirFlow** — 1 entry
- **EMS Air-Flow** — 1 entry
- **PrefGel** — 1 entry

Manufacturers: EMS (17), Straumann (13), Hu-Friedy (10), Geistlich (7), Biolase (6), Nobel Biocare (5), Dentsply (5), Dentium (4), KaVo (4), Zimmer Biomet (3), Fotona (3), Sirona (3), Sweden & Martina (2), Komet (2), Zimmer (2), Neobiotech (1), Dentsply Sirona (1), Osstem (1), Camlog (1), Satelec (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (21 different): chlorhexidine (42), saline (40), hydrogen peroxide (22), amoxicillin (18), tetracycline (15), antibiotics (systemic) (14), metronidazole (12), citric acid (10), sodium hypochlorite (10), minocycline (9), photosensitizer dye (9), sterile water (7), povidone-iodine (6), doxycycline (5), chloramine (3), enamel matrix derivative (2), EDTA (2), phosphoric acid / etching gel (2), Perisolv (1), hypochlorous acid (1), EDTA / citric acid gel (PrefGel) (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (156)

The 156 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- Next: [10. Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/)


---

# 10. Electrolytic cleaning

Chapter 10 of an evidence-based reader on implant surface decontamination in peri-implantitis: 31 entries on electrolytic cleaning — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about electrolytic (electrochemical) cleaning of the implant surface?

**Key facts — Electrolytic cleaning**

- Entries in this chapter: 31 of 819 (2019–2026): RCT 5 · clinical study 2 · case report/series 4 · systematic review 1 · review 5 · in vitro 12 · animal study 1 · not classified 1
- Most cited: [Markus Schlee et al. 2019](https://doi.org/10.3390/jcm8111909) (65); [Ratka C et al. 2019](https://doi.org/10.3390/jcm8091397) (54); [Bosshardt DD et al. 2022](https://doi.org/10.1007/s00784-021-04345-1) (45)
- Products named by the authors: GalvoSurge (7), Piezon (2), PerioFlow (2), AIRFLOW (1), Labrida BioClean (1), BioClean (1), R-Brush (1), i-Brush (1)
- Manufacturers named by the authors: EMS (4), Straumann (3), Geistlich (3), Hu-Friedy (1), Labrida (1), NSK (1), NeoBiotech (1)
- Chemical agents used alongside: chlorhexidine (10), saline (6), hydrogen peroxide (6), citric acid (3), hypochlorous acid (3), tetracycline (2), photosensitizer dye (1), doxycycline (1)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (14), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (9), [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) (6), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (6)
- Entries naming the NiTi Brush: 2 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

A low electric current is passed through an electrolyte solution that is in contact with the implant, which becomes the cathode; the hydrogen formed at the surface lifts the biofilm without mechanical contact. The papers name the method "electrolytic cleaning", "electrolytic approach" or a product name.


### Mechanism and use, as the papers describe it

In the laboratory descriptions the contaminated implant or disc is made the cathode in an electrolyte and a direct current is passed through it; Zhu et al. placed biofilm-covered discs as cathodes in physiological saline, and Virto et al. used a three-electrode cell with the implant as working electrode.[1,2] Bernardi et al. describe the method as acting on the adhesion forces of the biofilm, and Alonso-Español et al. observed a localised "bubble-shaped effect".[3,4] Most entries name one device, GalvoSurge (GalvoSurge Dental AG, Widnau, Switzerland).[5,6] Clinically the method is applied during surgical access, almost always within reconstructive therapy with grafting and, in several series, with crown removal and submerged healing.[7,8,9,10]


### Reported operating conditions

Zhu et al. considered 0.6 A for 5 min optimal among the settings they tested; Virto et al. applied 0.75, 1.5 and 3 V of either polarity for 5 min and found no effect at 0.75 V; Odeh et al. applied -3 V and -0.75 V for 5 min in a potassium iodide electrolyte followed by a 1-min rinse in 0.12% chlorhexidine.[1,2,11] Zipprich et al. compared potassium iodide and sodium formate solutions, and Chedid et al. ran GalvoSurge for 120 s.[12,13]


### Effects on the implant surface reported in laboratory studies

Zhu et al. reported no change in colour, topography, roughness or elemental composition of SLA discs and a super-hydrophilic surface afterwards; Fonseca et al. found lower hydrogen content, unchanged corrosion resistance and longer fatigue life; Ravidà et al. grouped electrolytic treatment among methods with minimal surface alteration.[1,6,14] On residual biofilm, Ratka et al. observed no bacterial growth, Zipprich et al. residual staining below 1% irrespective of surface angulation, and Odeh et al. removal of over 95% with current plus chlorhexidine, whereas Özay et al. found 28.5% residual stain in an ink model and Alonso-Español et al. found areas of non-vital biofilm and disrupted mucosal layers in a tissue model.[15,12,11,5,4] Histologically, Bosshardt et al. measured 5.7% to 39.0% re-osseointegration in four human implants, in one of which new bone was deposited onto residual calculus.[9]


### Position in treatment protocols

Schlee et al. compared electrolytic cleaning alone with powder spray plus electrolytic cleaning, found no difference in bone gain and concluded that the method needs no further mechanical cleaning by powder spray.[7,16] Other trials use it as an adjunct to mechanical decontamination: Monje et al. compared it with hydrogen peroxide after instrumentation and found no difference in clinical parameters, and Regidor et al. added it to a rotating titanium brush and reported no added benefit.[10,17,18] Reviews place the method among emerging adjuncts whose evidence is largely preclinical or from small cohorts.[19,20,21]


### Limitations and open questions as stated by the authors

Klein et al. found only four clinical studies, with recurrence in most and re-osseointegration in all, and called for clear clinical guidelines and surgical protocols.[22] Authors also note heterogeneous electrical dosing, single-species models, post-surgical complications in a test group, and that DNA-based microbiology does not distinguish viable from non-viable bacteria.[23,13,17,24]


### Sources cited in this description (24)

1. Zhu Y et al. (2024). The biofilm removal effect and osteogenic potential on the titanium surface by electrolytic cleaning: An in vitro comparison of electrolytic parameters and five techniques. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14245 · in vitro
2. Virto L et al. (2023). Electrochemical decontamination of titanium dental implants. An in vitro biofilm model study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14055 · in vitro
3. Bernardi S et al. (2023). Use of electrical field for biofilm implant removal. *Eur Rev Med Pharmacol Sci*. https://doi.org/10.26355/eurrev_202304_31328 · in vitro
4. Alonso-Español A et al. (2025). Antimicrobial Effect and Cytocompatibility After Using Different Decontamination Methods on Titanium Implant Surfaces: An In Vitro Study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14410 · in vitro
5. Özay F et al. (2026). Effect of Implant Surface Decontamination Procedures on Surface Morphology-In Vitro Study. *J Funct Biomater*. https://doi.org/10.3390/jfb17040166 · in vitro
6. Fonseca D et al. (2025). Effect Of Electrolytic Cleaning on Mechanical Properties for Titanium Dental Implants with Surface Contamination. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11082 · in vitro
7. Markus Schlee et al. (2019). Treatment of Peri-Implantitis—Electrolytic Cleaning Versus Mechanical and Electrolytic Cleaning—A Randomized Controlled Clinical Trial—Six-Month Results *Journal of Clinical Medicine*. https://doi.org/10.3390/jcm8111909 · RCT
8. Hakkers J et al. (2025). Electrolytic Cleaning as Part of Surgical Reconstructive Peri-Implantitis Treatment: A Case Series. *Dent J (Basel)*. https://doi.org/10.3390/dj13060237 · case report/series
9. Bosshardt DD et al. (2022). Evidence of re-osseointegration after electrolytic cleaning and regenerative therapy of peri-implantitis in humans: a case report with four implants. *Clin Oral Investig*. https://doi.org/10.1007/s00784-021-04345-1 · case report/series
10. Monje A et al. (2025). Electrolytic Surface Decontamination in the Reconstructive Therapy of Peri-implantitis: Single-Center Outcomes. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.7151 · clinical study
11. Odeh V et al. (2025). Antibacterial Effect of Combined Electrolytic and Chemical Decontamination Methods on Dental Implant Surfaces: In Vitro Study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70012 · in vitro
12. Zipprich H et al. (2022). Comparison of decontamination efficacy of two electrolyte cleaning methods to diode laser, plasma, and air-abrasive devices. *Clin Oral Investig*. https://doi.org/10.1007/s00784-022-04421-0 · RCT
13. Chedid C et al. (2026). Comparative Efficacy of Er,Cr:YSGG Laser, Electrolytic Cleaning, and Chlorhexidine for the Decontamination of Sandblasted, Large-Grit, Acid-Etched (SLA) Implant Surfaces: An In Vitro Controlled Study. *Cureus*. https://doi.org/10.7759/cureus.113294 · in vitro
14. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
15. Ratka C et al. (2019). The Effect of In Vitro Electrolytic Cleaning on Biofilm-Contaminated Implant Surfaces. *J Clin Med*. https://doi.org/10.3390/jcm8091397 · in vitro
16. Markus Schlee et al. (2021). Treatment of Periimplantitis with Electrolytic Cleaning versus Mechanical and Electrolytic Cleaning: 18-Month Results from a Randomized Controlled Clinical Trial *Journal of Clinical Medicine*. https://doi.org/10.3390/jcm10163475 · RCT
17. Regidor E et al. (2026). Adjunctive Electrolytic Implant Surface Decontamination in the Reconstructive Surgical Treatment of Peri-Implantitis-A Randomized Clinical Trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70152 · RCT
18. De Angelis N et al. (2026). Clinical and Radiographic Outcomes of Electrolytic Implant Surface Decontamination in Peri-Implantitis Surgery: A Retrospective Cohort Study. *Dent J (Basel)*. https://doi.org/10.3390/dj14070447 · clinical study
19. Mohammad Hossein Rasti et al. (2026). Current State of Advanced Biomaterials and Technologies in the Treatment of Peri-Implantitis: A Review of the Literature: Peri-Implantitis Biomaterials and Technologies *Regeneration, Reconstruction & Restoration*. https://doi.org/10.22037/rrr.v11.52124 · review
20. Lee K et al. (2026). Peri-implantitis: An Overview of Current Treatment Modalities (Part 1). *Compend Contin Educ Dent*. https://pubmed.ncbi.nlm.nih.gov/42709028/ · review
21. Althaaf Khan (2026). PERI-IMPLANTITIS PHENOTYPING AND MANAGEMENT: DIAGNOSTIC HETEROGENEITY AND THE EVIDENCE GAP IN IMPLANT SURFACE DECONTAMINATION AND RE-OSSEOINTEGRATION *Global journal of research in medicine and dentistry*. https://doi.org/10.58175/gjrmd.2026.5.4.0100 · not classified
22. Anastasia Klein et al. (2025). Electrolytic Cleaning of Dental Implants: A Scoping Review of Clinical Studies *Dentistry Journal*. https://doi.org/10.3390/dj13040172 · review
23. Aleksiejuk JP et al. (2026). Electrical and Electrochemical Control of Orthopedic Implant-Associated Biofilms: Mechanisms, Evidence, and Translational Challenges. *Antibiotics (Basel)*. https://doi.org/10.3390/antibiotics15111094 · review
24. Dražena Gerbl et al. (2026). Immediate Microbiological Efficacy of Electrolytic Cleaning Compared to Chlorhexidine in Peri-Implantitis: A Randomized Pilot Study *Applied Sciences*. https://doi.org/10.3390/app16178485 · RCT

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

5 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Clinical, radiographic and patient-reported outcomes of surgical therapy of peri-implantitis were favorable at 12 months. The adjunctive use of electrolytic cleaning provided no added benefit over the use of a rotating titanium brush alone.” — [Regidor E et al. 2026](https://doi.org/10.1111/clr.70152), Clin Oral Implants Res; cited 4.
- “In this exploratory randomized pilot sample, GalvoSurge was associated with a greater immediate reduction in recoverable bacterial target DNA than CHX after adjustment for pretreatment score. DNA-based qPCR does not distinguish viable from non-viable bacteria; therefore, the findings do not establish bacterial killing, sterility, or long-term clinical superiority.” — [Dražena Gerbl et al. 2026](https://doi.org/10.3390/app16178485), Applied Sciences; cited 0.
- “Within the limitations of the present in vitro study, electrolytic decontamination with KI and CHNaO2 was significantly more effective in reducing bacterial stained surface of rough titanium implants than air-abrasive powder, diode laser, and plasma cleaning, regardless of the accessibility of the contaminated implant location.” — [Zipprich H et al. 2022](https://doi.org/10.1007/s00784-022-04421-0), Clin Oral Investig; cited 20.
- “Significant radiographic bone fill and the improvement of clinical parameters were demonstrated 18 months after therapy.” — [Markus Schlee et al. 2021](https://doi.org/10.3390/jcm10163475), Journal of Clinical Medicine; cited 42.
- “EC needs no further mechanical cleaning by powder spray. Complete re-osseointegration in peri-implantitis cases is possible.” — [Markus Schlee et al. 2019](https://doi.org/10.3390/jcm8111909), Journal of Clinical Medicine; cited 65.


## What the systematic reviews and meta-analyses concluded

1 systematic review or meta-analysis mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

2 non-randomised clinical studies and 4 case reports or series.

- “Within the limitations of this retrospective study, both electrolytic and conventional mechanical implant surface decontamination protocols resulted in significant short-term clinical and radiographic improvements following peri-implantitis surgery. Electrolytic cleaning demonstrated outcomes comparable to conventional therapy and may represent a viable alternative for implant surface decontamination.” — [De Angelis N et al. 2026](https://doi.org/10.3390/dj14070447), Dent J (Basel); cited 0.
- “EM combined with mechanical instrumentation results in a safe and effective surface decontamination modality in the reconstructive therapy of peri-implantitis. This strategy resulted in a disease resolution rate of ~91%.” — [Monje A et al. 2025](https://doi.org/10.11607/prd.7151), Int J Periodontics Restorative Dent.


## Laboratory and animal findings

12 in vitro / ex vivo and 1 animal study. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “Multispecies oral biofilms were established on titanium implants using a controlled bioreactor model and subjected to different decontamination strategies. Biofilm persistence was evaluated by v-qPCR, SEM, and CLSM to assess treatment efficacy.” — [Castro AB et al. 2026](https://doi.org/10.1111/jre.70031), J Periodontal Res; cited 0.
- “All active protocols reduced viable Staphylococcus aureus counts compared with untreated implants. Within the limitations of this single-species in vitro model, Er,Cr:YSGG laser irradiation achieved the greatest reduction, whereas GalvoSurge and CHX resulted in moderate and comparable decreases.” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294), Cureus; cited 0.
- “This difference was independent of defect type (p > 0.05). These findings indicate that electrochemical cleaning via galvanic current may be more effective, under in vitro conditions, for stain removal and surface decontamination; however, they also demonstrate that residual contamination could not be completely eliminated irrespective of the method.” — [Özay F et al. 2026](https://doi.org/10.3390/jfb17040166), J Funct Biomater; cited 0.
- “Phytotherapeutics (CUR and XN) were the most cytocompatible substances and showed the largest antimicrobial effect. GS displayed antibiofilm activity with a localized "bubble-shaped effect" and impaired tissue cell morphology and integrity, compromising cytocompatibility, and CHX showed antimicrobial capacity, without reducing biofilm biomass and with altered cytocompatibility.” — [Alonso-Español A et al. 2025](https://doi.org/10.1111/clr.14410), Clin Oral Implants Res; cited 9.
- “The formation of hydrogen via electrolysis does not cause a diffusion of this element to Ti nor does it affect corrosion resistance, but it reduces the level of hydrogen, which favors its mechanical properties in the long term.” — [Fonseca D et al. 2025](https://doi.org/10.11607/jomi.11082), Int J Oral Maxillofac Implants; cited 6.
- “The proposed combined treatments were more effective in reducing the vitality of multispecies biofilms on implant surfaces compared to CHX alone.” — [Odeh V et al. 2025](https://doi.org/10.1111/clr.70012), Clin Oral Implants Res; cited 6.

6 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “An electrolytic approach was compared to a classical modality (ablative, cotton pellets soaked with sodium chloride solution and H2O2. For electrolytic cleaning a complete reosseointegration was achieved in several cases serving as a proof of concept.” — [Markus Schlee et al. 2020](https://doi.org/10.3390/jcm9010235), Journal of Clinical Medicine; cited 24.


## Parameters as stated in the abstracts

- “Implants were randomly assigned to four groups (n = 12/group): untreated control, CHX immersion for 60 s, GalvoSurge electrolytic cleaning for 120 s, or Er,Cr:YSGG laser treatment (2780 nm; 2.5 W; 30 Hz; 70% water; 60% air; 30 s).” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294) (in vitro).
- “Objective: To compare the immediate reduction in recoverable bacterial target DNA after electrolytic cleaning and 0.2% chlorhexidine (CHX).” — [Dražena Gerbl et al. 2026](https://doi.org/10.3390/app16178485) (RCT).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **GalvoSurge** — 7 entries
- **Piezon** — 2 entries
- **PerioFlow** — 2 entries
- **AIRFLOW** — 1 entry
- **Labrida BioClean** — 1 entry
- **BioClean** — 1 entry
- **R-Brush** — 1 entry
- **i-Brush** — 1 entry

Manufacturers: EMS (4), Straumann (3), Geistlich (3), Hu-Friedy (1), Labrida (1), NSK (1), NeoBiotech (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (12 different): chlorhexidine (10), saline (6), hydrogen peroxide (6), citric acid (3), hypochlorous acid (3), tetracycline (2), photosensitizer dye (1), doxycycline (1), amoxicillin (1), antibiotics (systemic) (1), povidone-iodine (1), sterile water (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (31)

The 31 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [3. Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- Next: [11. Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/)


---

# 11. Cold atmospheric plasma

Chapter 11 of an evidence-based reader on implant surface decontamination in peri-implantitis: 30 entries on cold atmospheric plasma — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/cold-plasma/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about cold atmospheric plasma for implant surface decontamination?

**Key facts — Cold atmospheric plasma**

- Entries in this chapter: 30 of 819 (2013–2026): RCT 1 · clinical study 1 · systematic review 2 · review 5 · in vitro 20 · not classified 1
- Most cited: [Duske K et al. 2015](https://doi.org/10.1016/j.biomaterials.2015.02.035) (126); [Idlibi AN et al. 2013](https://doi.org/10.1080/08927014.2013.775255) (79); [Hui WL et al. 2020](https://doi.org/10.3390/nano10081505) (77)
- Products named by the authors: AIRFLOW (2), Piezon (2), Air-Flow (1)
- Manufacturers named by the authors: Straumann (3), EMS (3), Sirona (2), Dentaurum (1), BioHorizons (1), Dentsply Sirona (1), Nobel Biocare (1), Zimmer Biomet (1), Osstem (1), Camlog (1)
- Chemical agents used alongside: saline (8), chlorhexidine (7), sodium hypochlorite (2), metronidazole (1), amoxicillin (1), citric acid (1), phosphoric acid / etching gel (1), hydrogen peroxide (1)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (13), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (8), [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) (7), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (6)


## What it is

An ionised gas (argon, helium or air) generated at near-body temperature and applied to the implant surface, alone or after mechanical cleaning. Most of the reports are laboratory studies of biofilm reduction and of the surface's wettability and cell response after treatment.


### Mechanism and use, as the papers describe it

Cold atmospheric plasma is described as a non-thermal ionised gas that generates reactive oxygen and nitrogen species, inactivates oral pathogens and modifies titanium surface chemistry at temperatures compatible with living tissue.[1] The entries use argon, argon-oxygen or ambient air, delivered by jet devices, a microwave argon jet at 2.45 GHz, a piezoelectric direct-discharge generator, a handheld air-plasma device, or a nozzle that uses the implant as counter-electrode.[2,3,4,5,6,7] Nearly all peri-implantitis entries are laboratory studies; the clinical entries are a training study in which dentists applied a plasma device during simulated open-flap therapy and a feasibility trial on healing abutments.[8,9,10]


### Reported operating conditions

Exposure times range from 10 to 120 s for suspensions and biofilms, 1 to 5 min at 3 or 10 mm nozzle distance, 3 min for a defect model or per 20 mm² of surface, 1 to 7 min for a microwave argon jet, and 12 min in an argon plasma chamber.[6,11,12,7,4,13] Idlibi et al. found efficacy correlated with duration and power, Hui et al. applied plasma in a liquid medium, and Altenburger et al. and Ulu et al. recorded surface temperatures below 40 °C.[14,15,7,16]


### Effects on the implant surface reported in laboratory studies

No entry reports a roughness change: Ulu et al., Hui et al. and Zeng et al. found roughness and nanotopography unchanged, Wagner et al. found elemental composition unaffected, Ho et al. found reduced surface carbon and increased hydrophilicity, and Ravidà et al. grouped cold atmospheric plasma among methods with minimal surface alteration.[16,17,5,18,19,20] Antibacterial results depend on the model: Jungbauer et al. recorded about 4-log reductions on titanium biofilm without reduction of biomass, Altenburger et al. a mean 4.9-log reduction of in situ biofilm, and Ulu et al. a 6-log inactivation of Staphylococcus aureus, whereas Haude et al. and Matthes et al. found plasma alone did not remove biofilm or allowed regrowth, and Flörke et al. and Idlibi et al. achieved no complete removal.[6,7,16,21,22,12,14] Cell studies report increased fibroblast adhesion without cytotoxicity, osteoblast growth after brushing plus plasma, and low cytotoxicity on reconstituted epithelia.[6,3,11]


### Position in treatment protocols

The entries test plasma mainly as a second step after mechanical cleaning: Duske et al. after brushing, Kamionka et al., Haude et al. and Matthes et al. after glycine or erythritol air-polishing, and Matthes et al. after a water-jet device.[3,23,21,22,24,25] Kamionka et al. and Haude et al. reported that the combination cleared biofilm more completely than air-polishing alone, whereas Matthes et al. found no added osteoblast spreading from it.[23,21,22] Reviews describe it as an adjunctive strategy whose evidence is largely preclinical, with no surgical trial for decontamination.[8,26,1]


### Limitations and open questions as stated by the authors

Authors point to the absence of clinical trials for decontamination, the need for standardised dosimetry and application protocols, single-species models, and heterogeneity of devices and parameters across studies.[1,8,4] Hui et al. observed no specific effect of plasma when added to air abrasion.[15]


### Sources cited in this description (26)

1. Papadimitriou I et al. (2026). Cold atmospheric plasma as a perioperative adjunct in oral surgery: A narrative review of surface activation, decontamination and soft-tissue healing. *Eur J Oral Sci*. https://doi.org/10.1111/eos.70161 · review
2. Hui WL et al. (2020). The Emerging Role of Cold Atmospheric Plasma in Implantology: A Review of the Literature. *Nanomaterials (Basel)*. https://doi.org/10.3390/nano10081505 · review
3. Duske K et al. (2015). Cold atmospheric plasma in combination with mechanical treatment improves osteoblast growth on biofilm covered titanium discs. *Biomaterials*. https://doi.org/10.1016/j.biomaterials.2015.02.035 · in vitro
4. Bogdanov T et al. (2026). Atmospheric Cold Microwave Argon Plasma for Decontamination of Dental Implant Surfaces: An In Vitro Experimental Study. *J Funct Biomater*. https://doi.org/10.3390/jfb17050211 · in vitro
5. Zeng Y et al. (2020). Enhanced Osseointegration and Bio-Decontamination of Nanostructured Titanium Based on Non-Thermal Atmospheric Pressure Plasma. *Int J Mol Sci*. https://doi.org/10.3390/ijms21103533 · in vitro
6. Gert Jungbauer et al. (2022). The In-Vitro Activity of a Cold Atmospheric Plasma Device Utilizing Ambient Air against Bacteria and Biofilms Associated with Periodontal or Peri-Implant Diseases *Antibiotics*. https://doi.org/10.3390/antibiotics11060752 · in vitro
7. Altenburger MJ et al. (2025). In Situ Eradication of Mature Oral Biofilm on Titanium Implant Surfaces Using Cold Atmospheric Plasma. *Dent J (Basel)*. https://doi.org/10.3390/dj13050210 · in vitro
8. Shahraki K et al. (2026). Cold atmospheric plasma for implant surface decontamination and osseointegration: a scoping review with implications for peri-implantitis management. *BMC Oral Health*. https://doi.org/10.1186/s12903-026-09164-y · review
9. Rutger Matthes et al. (2024). Training in the use of the water jet and cold atmospheric plasma jet for the decontamination of dental implants *Clinical Oral Investigations*. https://doi.org/10.1007/s00784-024-05749-5 · clinical study
10. Yossri D et al. (2025). Soft tissue response to titanium healing abutments treated by Er: YAG laser or plasma spray: A randomized controlled feasibility clinical study with SEM and histological analysis. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.13373 · RCT
11. Panariello BHD et al. (2024). Tissue-Safe Low-Temperature Plasma Treatment for Effective Management of Mature Peri-Implantitis Biofilms on Titanium Surfaces. *ACS Biomater Sci Eng*. https://doi.org/10.1021/acsbiomaterials.4c01413 · in vitro
12. Flörke C et al. (2022). In-vitro assessment of the efficiency of cold atmospheric plasma on decontamination of titanium dental implants. *Int J Implant Dent*. https://doi.org/10.1186/s40729-022-00411-9 · in vitro
13. Marco Annunziata et al. (2015). Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces: In vitro study *Medicina oral, patología oral y cirugía bucal*. https://doi.org/10.4317/medoral.20845 · in vitro
14. Idlibi AN et al. (2013). Destruction of oral biofilms formed in situ on machined titanium (Ti) surfaces by cold atmospheric plasma. *Biofouling*. https://doi.org/10.1080/08927014.2013.775255 · in vitro
15. Hui WL et al. (2021). Cold atmospheric plasma coupled with air abrasion in liquid medium for the treatment of peri-implantitis model grown with a complex human biofilm: an in vitro study. *Clin Oral Investig*. https://doi.org/10.1007/s00784-021-03949-x · in vitro
16. Ulu M et al. (2018). Antibiofilm efficacies of cold plasma and er: YAG laser on Staphylococcus aureus biofilm on titanium for nonsurgical treatment of peri-implantitis. *Niger J Clin Pract*. https://doi.org/10.4103/njcp.njcp_261_17 · in vitro
17. Hui WL et al. (2021). Novel technique using cold atmospheric plasma coupled with air-polishing for the treatment of titanium discs grown with biofilm: An in-vitro study. *Dent Mater*. https://doi.org/10.1016/j.dental.2020.11.027 · in vitro
18. Gunar Wagner et al. (2021). Influence of cold atmospheric plasma on dental implant materials — an in vitro analysis *Clinical Oral Investigations*. https://doi.org/10.1007/s00784-021-04277-w · in vitro
19. Ho K et al. (2025). Plasma Treatment to Remove Titanium Surface Contaminants and Improve Implant Biocompatibility: An In Vitro Study. *Biomimetics (Basel)*. https://doi.org/10.3390/biomimetics10090571 · in vitro
20. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
21. Haude S et al. (2024). In-vitro biofilm removal from TiUnite® implant surface with an air polishing and two different plasma devices. *BMC Oral Health*. https://doi.org/10.1186/s12903-024-04230-9 · in vitro
22. Matthes R et al. (2017). Osteoblast growth, after cleaning of biofilm-covered titanium discs with air-polishing and cold plasma. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12720 · in vitro
23. Kamionka J et al. (2022). Efficiency of cold atmospheric plasma, cleaning powders and their combination for biofilm removal on two different titanium implant surfaces. *Clin Oral Investig*. https://doi.org/10.1007/s00784-021-04300-0 · in vitro
24. Matthes R et al. (2022). Efficiency of biofilm removal by combination of water jet and cold plasma: an in-vitro study. *BMC Oral Health*. https://doi.org/10.1186/s12903-022-02195-1 · in vitro
25. Matthes R et al. (2023). In-Vitro Biofilm Removal Efficacy Using Water Jet in Combination with Cold Plasma Technology on Dental Titanium Implants. *Int J Mol Sci*. https://doi.org/10.3390/ijms24021606 · in vitro
26. Mohammad Hossein Rasti et al. (2026). Current State of Advanced Biomaterials and Technologies in the Treatment of Peri-Implantitis: A Review of the Literature: Peri-Implantitis Biomaterials and Technologies *Regeneration, Reconstruction & Restoration*. https://doi.org/10.22037/rrr.v11.52124 · review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

1 randomised trial in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Within the limitations of this feasibility study, the present data concluded that plasma spray and Erbium: YAG laser can be used for abutment surface treatment to achieve better peri-implant soft tissue healing.” — [Yossri D et al. 2025](https://doi.org/10.1111/cid.13373), Clin Implant Dent Relat Res; cited 7.


## What the systematic reviews and meta-analyses concluded

2 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

1 non-randomised clinical study and 0 case reports or series.

- “A moderate learning curve was found for handling of the water jet but none for handling of the cold plasma. CLINICAL RELEVANCE: Scientific rational for study: Two new devices were developed for peri-implantitis treatment (Dental water jet, cold plasma). Dentists were trained in the use of these devices prior to the trial to minimize learning effects.” — [Rutger Matthes et al. 2024](https://doi.org/10.1007/s00784-024-05749-5), Clinical Oral Investigations; cited 6.


## Laboratory and animal findings

20 in vitro / ex vivo and 0 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “These findings indicate that microwave argon plasma exhibits significant antimicrobial activity under controlled in vitro conditions, although its effectiveness depends on microorganism-specific biological characteristics.” — [Bogdanov T et al. 2026](https://doi.org/10.3390/jfb17050211), J Funct Biomater; cited 0.
- “Within the study's limitations, cold atmospheric plasma effectively eradicates mature oral biofilm on titanium surfaces. This high disinfection efficacy is likely due to the combined action of reactive species and electrical phenomena, which does not cause significant temperature increases.” — [Altenburger MJ et al. 2025](https://doi.org/10.3390/dj13050210), Dent J (Basel); cited 6.
- “, plasma treatment reduces hydrocarbon buildup, enhances hydrophilicity, promotes early cell attachment, and upregulates genes linked to angiogenesis and proliferation. Further studies are needed to determine its clinical significance in managing peri-implant disease.” — [Ho K et al. 2025](https://doi.org/10.3390/biomimetics10090571), Biomimetics (Basel); cited 6.
- “, the study's results support the effectiveness of 1 min LTP exposure in successfully disinfecting mature peri-implantitis multispecies biofilms on titanium discs and implants. Moreover, it validated the safety of LTP on ROE, suggesting its potential as an adjunctive treatment for peri-implantitis.” — [Panariello BHD et al. 2024](https://doi.org/10.1021/acsbiomaterials.4c01413), ACS Biomater Sci Eng; cited 10.
- “AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots.” — [Haude S et al. 2024](https://doi.org/10.1186/s12903-024-04230-9), BMC Oral Health; cited 7.
- “The combined treatment with WaterJet and CAP potently removed biofilm and disinfected rough titanium implant surfaces. At the same time, non-favorable rendering of the surface structure or its pro-inflammatory potential through CAP was not observed.” — [Matthes R et al. 2023](https://doi.org/10.3390/ijms24021606), Int J Mol Sci; cited 21.

14 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Parameters as stated in the abstracts

- “Bacterial suspensions of Streptococcus mutans NBIMCC 1786 and the extremophilic bacterium Chromohalobacter canadensis NBIMCC 9077 have been exposed to a microwave non-equilibrium argon plasma jet (2.45 GHz, atmospheric pressure) for 1-7 min.” — [Bogdanov T et al. 2026](https://doi.org/10.3390/jfb17050211) (in vitro).
- “The AmbiJet device delivered plasma directly to the implant surface for 3 min per 20 mm2, utilizing the applicator nozzle and implant as electrodes.” — [Altenburger MJ et al. 2025](https://doi.org/10.3390/dj13050210) (in vitro).
- “These biofilms were subjected to LTP treatment for 1, 3, and 5 min, using distances of 3 or 10 mm from the LTP nozzle to the samples.” — [Panariello BHD et al. 2024](https://doi.org/10.1021/acsbiomaterials.4c01413) (in vitro).
- “Suspensions of 11 oral bacteria (among them Fusobacterium nucleatum, Porphyromonas gingivalis, Parvimonas micra, Streptococcus gordonii, and Tannerella forsythia) were exposed to CAP for 10, 30, 60, and 120 s.” — [Gert Jungbauer et al. 2022](https://doi.org/10.3390/antibiotics11060752) (in vitro).
- “The aim of the current study was to comparatively assess the efficiency of three different adjunctive therapy options (cold atmospheric plasma, \[CAP\], photodynamic therapy \[PDT\] and chemical decontamination via 35% phosphoric acid gel \[PAG\]) on decontamination of titanium implant surfaces in-vitro.” — [Flörke C et al. 2022](https://doi.org/10.1186/s40729-022-00411-9) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **AIRFLOW** — 2 entries
- **Piezon** — 2 entries
- **Air-Flow** — 1 entry

Manufacturers: Straumann (3), EMS (3), Sirona (2), Dentaurum (1), BioHorizons (1), Dentsply Sirona (1), Nobel Biocare (1), Zimmer Biomet (1), Osstem (1), Camlog (1), Sweden & Martina (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (11 different): saline (8), chlorhexidine (7), sodium hypochlorite (2), metronidazole (1), amoxicillin (1), citric acid (1), phosphoric acid / etching gel (1), hydrogen peroxide (1), hypochlorous acid (1), povidone-iodine (1), sterile water (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (30)

The 30 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/cold-plasma/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [10. Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/)
- Next: [12. Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/)


---

# 12. Rubber cups and polishing paste

Chapter 12 of an evidence-based reader on implant surface decontamination in peri-implantitis: 11 entries on rubber cups and polishing paste — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about rubber-cup polishing with paste or pumice on implant surfaces?

**Key facts — Rubber cups and polishing paste**

- Entries in this chapter: 11 of 819 (2014–2026): clinical study 1 · case report/series 1 · systematic review 2 · review 3 · in vitro 4
- Most cited: [Louropoulou A et al. 2014](https://doi.org/10.1111/clr.12224) (153); [Park JB et al. 2015](https://doi.org/10.1111/clr.12302) (58); [Cafiero C et al. 2017](https://doi.org/10.1111/clr.12849) (26)
- Products named by the authors: none named in the abstracts or open-access full texts read
- Manufacturers named by the authors: EMS (1), Hu-Friedy (1), Komet (1), Straumann (1)
- Chemical agents used alongside: chlorhexidine (3), citric acid (1), photosensitizer dye (1), saline (1), povidone-iodine (1)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (10), [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) (8), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (7), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (4)


## What it is

Rotary rubber cups or prophylaxis brushes with a polishing paste or pumice, as used in supportive care and in some laboratory comparisons of instrument effects on titanium surfaces.


### Mechanism and use, as the papers describe it

Rubber-cup polishing appears in the entries as one of the mechanical techniques for debridement of implants, listed with scaling, air-powder abrasion and brushing.[1] Cafiero et al. describe a rotary rubber cup or brush carrying an abrasive paste, either zirconium-containing or perlite-derived, applied to the smooth collar of tissue-level implants, and Pujarern et al. applied prophy paste with a rubber cup to titanium and other prosthetic materials.[2,3] The setting is supportive care rather than surgery: Mariani et al. provided professional implant cleaning with rubber cups at three-monthly recalls after treatment of mucositis, and the reviews place rubber cups among instruments for removing plaque and calculus from the supra- and submucosal part of the implant.[4,5,6]


### Reported operating conditions

The abstracts give the paste rather than speed or pressure: zirconium-containing and perlite-derived pastes with cups or brushes, a commercial prophy paste, and an unspecified abrasive paste.[2,3,7] Kister et al. measured the pressure applied during instrumentation online and tested rubber cups alongside silicone polishers on anatase-coated discs.[8]


### Effects on the implant surface reported in laboratory studies

Cafiero et al. measured Ra 0.33 µm and Rz 2.43 µm after a rubber cup with zirconium paste and Ra 0.28 µm and Rz 2.02 µm with perlite paste on implant collars, the highest values among eight procedures, but none increased roughness significantly.[2] Pujarern et al., by contrast, found significantly higher roughness on titanium and on lithium disilicate after prophy paste with a rubber cup.[3] Kister et al. found that rubber cups left anatase nanocoatings intact while silicone polishers smoothed them and abolished their photocatalytic function.[8] Yen Nee et al. summarised that rubber cups left titanium surfaces unchanged or smoother.[6] On cleaning, Louropoulou et al. found rubber cups ineffective on contaminated titanium in their systematic review, whereas Chen et al. cite a report of greater biofilm reduction with rubber-cup polishing and abrasive paste than with glycine air abrasion.[9,7] Valeriani et al. note that roughness after decontamination changes without a consistent pattern across in vitro studies.[10]


### Position in treatment protocols

Rubber cups are described as a maintenance instrument used at recall visits and as one of the non-metallic options for routine debridement, not as a decontamination step in surgical peri-implantitis protocols.[4,5,6] Kister et al. suggest rubber cups with polishing paste, air-flow devices and plastic-tipped instruments for nanocoated surfaces.[8]


### Limitations and open questions as stated by the authors

Louropoulou et al. note that the laboratory studies were too heterogeneous for quantitative analysis and that their clinical impact requires clarification, Pujarern et al. and Curylofo-Zotti et al. call for further studies, and Valeriani et al. suggest clinical trials to link surface alterations to outcomes.[9,3,5,10]


### Sources cited in this description (10)

1. Park JB et al. (2015). Effects of titanium brush on machined and sand-blasted/acid-etched titanium disc using confocal microscopy and contact profilometry. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12302 · in vitro
2. Cafiero C et al. (2017). Implant surface roughness alterations induced by different prophylactic procedures: an in vitro study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12849 · in vitro
3. Pujarern P et al. (2026). Surface Roughness Assessment of Implant Prosthetic Components Treated by Dental Ultrasonic and Polishing Instruments. *Eur J Dent*. https://doi.org/10.1055/s-0046-1818622 · in vitro
4. Giulia Maria Mariani et al. (2020). One-year clinical outcomes following non-surgical treatment of peri-implant mucositis with adjunctive diode laser application *Minerva Dental and Oral Science*. https://doi.org/10.23736/s0026-4970.20.04340-x · clinical study
5. Fabiana Almeida Curylofo‐Zotti et al. (2014). instrumentation of dental implants: a literature review *RSBO*. https://doi.org/10.21726/rsbo.v10i1.900 · review
6. Yen Nee W et al. (2022). Effects on the Titanium Implant Surface by Different Hygiene Instrumentations: A Narrative Review. *Cureus*. https://doi.org/10.7759/cureus.30884 · review
7. Chen A et al. (2023). A Review of Bacterial Colonization on Dental Implants With Various Hygiene Instruments. *Cureus*. https://doi.org/10.7759/cureus.47483 · review
8. Kister F et al. (2017). Peri-implantitis cleaning instrumentation influences the integrity of photoactive nanocoatings. *Dent Mater*. https://doi.org/10.1016/j.dental.2016.10.002 · in vitro
9. Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12224 · systematic review
10. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

No randomised trial in the index names this method.


## What the systematic reviews and meta-analyses concluded

2 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “The available data suggest that the air abrasive may remove plaque effectively from machined, SLA and TPS titanium surfaces. Positive results were also observed for rotating titanium brushes on SLA surfaces and ultrasonic scalers with non-metal tip on polished and SLA surfaces. However, the clinical impact of these findings requires further clarification.” — [Louropoulou A et al. 2014](https://doi.org/10.1111/clr.12224), Clin Oral Implants Res; cited 153.


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

1 non-randomised clinical study and 1 case report or series.

- “Based on the present results, the adjunct use of diode laser showed little but not statistically significant additional benefits in the treatment of peri-implant mucositis after an observation period of one year.” — [Giulia Maria Mariani et al. 2020](https://doi.org/10.23736/s0026-4970.20.04340-x), Minerva Dental and Oral Science; cited 24.


## Laboratory and animal findings

4 in vitro / ex vivo and 0 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “From this study, air polishing devices should be used with caution with titanium, PEEK, and zirconia; Prophy paste should be used with caution with titanium and lithium disilicate; and P5 scaler should be used with caution with zirconia. Further studies are required to study the clinical outcomes.” — [Pujarern P et al. 2026](https://doi.org/10.1055/s-0046-1818622), Eur J Dent; cited 1.
- “All tested procedures did not increase implant surface roughness significantly. Treatment with an air-powder abrasive system at high-pressure setting resulted in a smoothening of the implant collar surface.” — [Cafiero C et al. 2017](https://doi.org/10.1111/clr.12849), Clin Oral Implants Res; cited 26.
- “The integrity of functional nanocoatings depends on the applied instrumentation. Air flow device, rubber cup with polishing paste and plastic tipped instruments prevent damage on these nanosurfaces and may be preferably used when decontaminating anatase and other nanocoatings in a clinical setting.” — [Kister F et al. 2017](https://doi.org/10.1016/j.dental.2016.10.002), Dent Mater; cited 13.
- “This study showed that the treatment with the titanium brush did not significantly change the roughness parameters, including Sa and Sz, in both MA and SA surfaces. Correlations between confocal microscopy and surface profilometry showed high correlation with a Pearson correlation coefficient of 0.98.” — [Park JB et al. 2015](https://doi.org/10.1111/clr.12302), Clin Oral Implants Res; cited 58.


## Parameters as stated in the abstracts

The abstracts in this chapter state no numeric operating parameter (speed, power, time, pressure, concentration); such details are in the papers' Methods sections.

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

Manufacturers: EMS (1), Hu-Friedy (1), Komet (1), Straumann (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (5 different): chlorhexidine (3), citric acid (1), photosensitizer dye (1), saline (1), povidone-iodine (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (11)

The 11 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [11. Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/)
- Next: [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)


---

# 13. Chemical and antiseptic agents

Chapter 13 of an evidence-based reader on implant surface decontamination in peri-implantitis: 216 entries on chemical and antiseptic agents — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/chemical-agents/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about chemical agents (saline, chlorhexidine, hydrogen peroxide, citric acid, antibiotics …) on the implant surface?

**Key facts — Chemical and antiseptic agents**

- Entries in this chapter: 216 of 819 (2003–2026): RCT 9 · clinical study 29 · case report/series 34 · systematic review 19 · review 35 · in vitro 69 · animal study 5 · not classified 16
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Figuero E et al. 2014](https://doi.org/10.1111/prd.12049) (521); [Rokaya D et al. 2020](https://doi.org/10.1055/s-0040-1715779) (293)
- Products named by the authors: Perisolv (5), Air-Flow (5), TiBrush (5), Perio-Flow (3), GalvoSurge (3), i-Brush (3), Piezon (3), PrefGel (2), Ti-Brush (2), NiTi Brush (1)
- Manufacturers named by the authors: Straumann (18), EMS (12), Dentsply Sirona (5), Nobel Biocare (4), Geistlich (4), Biolase (3), Dentium (3), Zimmer Biomet (3), Hu-Friedy (3), Komet (3)
- Chemical agents used alongside: chlorhexidine (88), saline (64), hydrogen peroxide (45), citric acid (36), tetracycline (24), sodium hypochlorite (24), antibiotics (systemic) (22), amoxicillin (12)
- Often studied together with: [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (56), [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (55), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (54), [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) (39)
- Entries naming the NiTi Brush: 3 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Solutions, gels or pastes applied to the implant surface to inactivate or detach biofilm and its products — saline, chlorhexidine, hydrogen peroxide, citric acid, EDTA, phosphoric acid, sodium hypochlorite, povidone-iodine, local antibiotics and others — alone or, in most clinical protocols, after mechanical debridement. The chemical adjuncts named in every entry of the reader are also listed in each method chapter.


### Mechanism and use, as the papers describe it

The publications in this chapter describe solutions, gels and slurries applied to the implant surface to dilute bacterial concentrations, destroy organic components of the biofilm and remove endotoxin, in conjunction with mechanical measures.[1] Non-surgical and surgical therapy are both described as mechanical debridement with or without adjunctive local antiseptics or antibiotics.[2] Agents named in the entries include sterile saline, chlorhexidine, hydrogen peroxide, citric acid, EDTA, sodium hypochlorite, hypochlorous acid, povidone-iodine, phosphoric acid gel, chlorine dioxide and the tetracyclines.[3,4,5,6,7]

Soaked pellets or gauze are rubbed over the surface: Solakoğlu et al. rubbed pellets soaked in 0.2% chlorhexidine and 3.0% hydrogen peroxide for 30 s three times in alternation, Sallé et al. scrubbed 0.25% sodium hypochlorite and 1.5% hydrogen peroxide with cotton pellets, and Ichioka et al. used gauze soaked in saline, alkaline electrolysed water, citric acid or N-acetyl-L-cysteine.[8,9,10] Irrigation is described with 0.2% chlorhexidine after curettage, with 0.12% chlorhexidine submucosally, and with chlorhexidine, hydrogen peroxide, alcohol or saline inside two-piece implants.[11,12,13] Gels include chlorhexidine, citric acid, sodium hypochlorite, orthophosphoric acid, a sulfonic/sulfuric acid desiccant and a peroxide-activated poloxamer; other forms are a doxycycline–saline slurry, a tetracycline slurry and chlorhexidine 2.5 mg chips.[14,15,16,17,18,19,20,21]

Chemical agents are almost always described after or together with mechanical debridement.[22] Ex vivo, hydrogen peroxide with chlorhexidine alone left bacterial counts no different from untreated implants whereas air-powder abrasion with or without the chemical step reduced them, and on retrieved implants saline, chlorhexidine, citric acid, 35% phosphoric acid gel and hydrogen peroxide removed no biologic debris.[23,24] Ichioka et al. found no relevant benefit of chemical adjuncts over saline after air-polishing or titanium brushes, while Lollobrigida et al. reported that 40% citric acid or 5.25% sodium hypochlorite combined with a titanium brush or glycine air-polishing removed more biofilm than the mechanical step alone.[25,26]


### Reported operating conditions

Laboratory exposures are mostly short: 1 min or 60 s for sodium hypochlorite, 3% hydrogen peroxide, 0.2% chlorhexidine gluconate and 40% citric acid in two studies on in vivo and single-species biofilm.[27,28] Ungvári et al. applied 3% hydrogen peroxide for 5 min, saturated citric acid (pH 1) for 1 min and chlorhexidine gel for 5 min; Lollobrigida et al. applied 5.25% sodium hypochlorite, 0.2% or 1% chlorhexidine, 40% citric acid gel and 37% orthophosphoric acid gel for 2 min.[14,16] Kotsakis et al. burnished discs with 0.12% chlorhexidine, 20% citric acid or 24% EDTA with 1.5% sodium hypochlorite; Stein et al. used 1% chlorhexidine, 10% povidone-iodine, 14% doxycycline and 0.95% sodium hypochlorite; Corrêa et al. immersed discs for 1 min in 0.2% chlorhexidine, 3% hydrogen peroxide, 1% sodium hypochlorite or 10–40% citric acid.[3,4,29] Immersions of 7 days or 168 h in 3% hydrogen peroxide, 40% citric acid, 17–40% EDTA or a citric–phosphoric acid mixture were used to accentuate surface effects, the authors acknowledging that clinical exposures are substantially shorter.[30,31]

De Waal et al. compared a 2% chlorhexidine solution with 0.12% chlorhexidine plus 0.05% cetylpyridinium chloride during resective surgery.[32] Bolun et al. applied 0.05% chlorhexidine gluconate and 3% hydrogen peroxide, Alotaibi et al. used 3% hydrogen peroxide for one minute after a titanium brush, and Mayer et al. combined 0.95% hypochlorite with 1 mg minocycline HCl.[33,34,35] A systematic review found 0.2% and 0.12% chlorhexidine, 40% citric acid and 1% sodium hypochlorite the most commonly used agents, and mucositis trials used chlorhexidine at 0.06–0.2%, at 0.03% with 0.05% cetylpyridinium chloride, or as a 0.2% gel.[36,37] In a canine model 0.12% chlorhexidine and 1.5% sodium hypochlorite were compared with saline.[38]


### Effects on the implant surface reported in laboratory studies

Ungvári et al. found no roughness change and an intact TiO2 layer after 3% hydrogen peroxide, saturated citric acid or chlorhexidine gel, with chlorhexidine infiltrating the surface.[14] Kotsakis et al. detected residues of each agent that altered wettability and showed some cytotoxic effect, with more cells on saline-treated than on chlorhexidine-treated discs.[3] Mester et al. described selective corrosion with a passivation layer after hydrogen peroxide, grain-boundary etching after citric acid, grain dissolution and debris after EDTA and the highest roughness after a citric–phosphoric mixture, with macrostructure preserved; Pogacian-Maier et al. reported preserved passive film and stem cell viability above 75% with citric acid and Ringer's solution but pronounced corrosion and 57–65% viability with hydrogen peroxide and mixed acid.[30,31] Corrêa et al. found morphological damage after 1% sodium hypochlorite and 40% citric acid but preserved integrity with 10–30% citric acid, and no biofilm reduction after 1 min in chlorhexidine or hydrogen peroxide.[29] On implantoplasty-machined surfaces hydrogen peroxide increased roughness while citric acid and EDTA did not, and concentrated hypochlorous acid with 6% hydrogen peroxide raised Ra from 0.33 to 0.68 µm with cytotoxicity at 72 h.[39,40] Tetracycline-HCl partially removed a hydroxyapatite coating and a TiO2-blasted surface within 90 s and 60 s, and a systematic review found the roughness of machined titanium changed without a consistent pattern.[41,42]

Stein et al. reported impaired fibroblast cytocompatibility after chlorhexidine, povidone-iodine, doxycycline and sodium hypochlorite, Brunello et al. found the highest cytotoxicity with 0.2% chlorhexidine, whereas Masa et al. reported viability similar to controls after 5 min of chlorhexidine, povidone-iodine or chlorine dioxide.[4,43,7] Jin et al. found that none of 14 methods restored the cytocompatibility of pristine sandblasted acid-etched titanium.[44] On residual biofilm, Gosau et al. found all tested antiseptics reduced bacterial load with a bactericidal effect for sodium hypochlorite, hydrogen peroxide and chlorhexidine but not citric acid, Bürgers et al. found only sodium hypochlorite effective against all three test species, and a meta-analysis of in vitro studies identified a significant difference only for chlorhexidine against phosphate-buffered saline.[27,28,45]


### Position in treatment protocols

In non-surgical treatment, a 2015 meta-analysis found that adjunctive antiseptics or antibiotics did not favour bleeding or probing depth over control in mucositis, while adjunctive local antibiotics favoured bleeding reduction at peri-implantitis sites.[46] Zhao et al. reported short-term chlorhexidine benefits in mucositis that disappeared at later follow-up, Banu et al. found scant evidence for local tetracyclines, and Machtei et al. reported greater pocket reduction with repeated chlorhexidine chips.[47,48,21]

In surgery, de Waal et al. found that 2% chlorhexidine did not improve results over 0.12% chlorhexidine with cetylpyridinium chloride, although chlorhexidine reduced anaerobic counts more than mechanical debridement alone.[32] Carcuac et al. reported that the benefit of systemic antibiotics was limited to modified surfaces and to the first year.[49] A 2016 systematic review found bleeding and probing depth reduced after implantoplasty and systemic antibacterials but not after local chemical compounds, and a network meta-analysis found no significant improvement from adjunctive antiseptics or systemic antibiotics.[50,51] A 2026 narrative review concluded that chlorhexidine generally provided limited additional benefit and that evidence for systemic antibiotics was inconsistent, and surveyed experts expressed concern about unnecessary systemic antibiotics.[52,53] In preclinical models, sodium hypochlorite added to a titanium brush had a minor effect, a citric acid gel did not improve resolution over saline, and Qian et al. reported 42% re-osseointegration after 1.5% sodium hypochlorite against a non-significant 26% after 0.12% chlorhexidine.[54,15,38]


### Limitations and open questions as stated by the authors

Patil et al. stated that data are scarce and that no definite conclusion is possible.[36] Valderrama et al. noted that complete biofilm elimination is difficult, that all therapies change the surface, and that combination protocols obscure the efficacy of any single method.[55,56] Kotsakis et al. described a dissociation between bacterial reduction and biological outcomes, and Hart et al. found significant heterogeneity across in vitro studies.[3,45] Mester et al. and Corrêa et al. acknowledged that their immersion models do not reproduce clinical exposure.[30,29] Pliaka et al. observed that reductions in bleeding and probing depth did not reliably correspond to microbiological or radiographic outcomes, and surveyed specialists agreed that chemical decontamination needs better documentation.[52,53]


### Sources cited in this description (56)

1. Monje A et al. (2022). Strategies for implant surface decontamination in peri-implantitis therapy. *Int J Oral Implantol (Berl)*. https://pubmed.ncbi.nlm.nih.gov/36082658/ · not classified
2. Figuero E et al. (2014). Management of peri-implant mucositis and peri-implantitis. *Periodontol 2000*. https://doi.org/10.1111/prd.12049 · review
3. Kotsakis GA et al. (2016). Antimicrobial Agents Used in the Treatment of Peri-Implantitis Alter the Physicochemistry and Cytocompatibility of Titanium Surfaces. *J Periodontol*. https://doi.org/10.1902/jop.2016.150684 · in vitro
4. Stein JM et al. (2023). Antimicrobial efficiency and cytocompatibility of different decontamination methods on titanium and zirconium surfaces. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14014 · in vitro
5. Costa RC et al. (2024). Efficacy of a novel three-step decontamination protocol for titanium-based dental implants: An in vitro and in vivo study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14224 · in vitro
6. Chen CJ et al. (2016). Effectiveness of Hypochlorous Acid to Reduce the Biofilms on Titanium Alloy Surfaces in Vitro. *Int J Mol Sci*. https://doi.org/10.3390/ijms17071161 · in vitro
7. Masa R et al. (2022). Surface Free Energy and Composition Changes and Ob Cellular Response to CHX-, PVPI-, and ClO2-Treated Titanium Implant Materials. *J Funct Biomater*. https://doi.org/10.3390/jfb13040202 · in vitro
8. Önder Solakoğlu et al. (2018). Regenerative Therapy of Peri-Implantitis: Clinical and Radiologic Documentation of 16 Consecutive Patients With a Mean Follow-Up of 3 Years *Journal of Oral Implantology*. https://doi.org/10.1563/aaid-joi-d-18-00168 · clinical study
9. Marcos Ribeiro Sallé et al. (2023). Decontamination and Repair Protocol Promotes Positive Outcomes in Implants Affected by Peri-implantitis: A Human Case Series *The International Journal of Periodontics & Restorative Dentistry*. https://doi.org/10.11607/prd.5534 · case report/series
10. Ichioka Y et al. (2021). In vitro evaluation of chemical decontamination of titanium discs. *Sci Rep*. https://doi.org/10.1038/s41598-021-02220-3 · in vitro
11. Sun F et al. (2022). Shift in the submucosal microbiome of diseased peri-implant sites after non-surgical mechanical debridement treatment. *Front Cell Infect Microbiol*. https://doi.org/10.3389/fcimb.2022.1091938 · clinical study
12. Leira Y et al. (2026). Non-Surgical Treatment of Peri-implantitis Associated Intrabony Defects with the Use of Adjunctive Systemic Azithromycin: Clinical and Radiographic Outcomes of a Dual-Centre Retrospective Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11673 · clinical study
13. Pia‐Merete Jervøe‐Storm et al. (2021). Comparison of irrigation protocols for the internal decontamination of dental implants—results of in vitro and in vivo studies *Clinical Oral Implants Research*. https://doi.org/10.1111/clr.13814 · clinical study
14. Ungvári K et al. (2010). Effects on titanium implant surfaces of chemical agents used for the treatment of peri-implantitis. *J Biomed Mater Res B Appl Biomater*. https://doi.org/10.1002/jbm.b.31644 · in vitro
15. Almohandes A et al. (2022). Surgical treatment of experimental peri-implantitis using mechanical and chemical decontamination procedures: A pre-clinical in vivo study. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13607 · animal study
16. Marco Lollobrigida et al. (2019). Antibacterial Activity and Impact of Different Antiseptics on Biofilm-Contaminated Implant Surfaces *Applied Sciences*. https://doi.org/10.3390/app9245467 · in vitro
17. Citterio F et al. (2022). Comparison of Different Chemical and Mechanical Modalities for Implant Surface Decontamination: Activity against Biofilm and Influence on Cellular Regrowth-An In Vitro Study. *Front Surg*. https://doi.org/10.3389/fsurg.2022.886559 · in vitro
18. Hussain B et al. (2024). Biofouling on titanium implants: a novel formulation of poloxamer and peroxide for in situ removal of pellicle and multi-species oral biofilm. *Regen Biomater*. https://doi.org/10.1093/rb/rbae014 · in vitro
19. Neely AL et al. (2020). Successful Management of Peri-Implantitis Using a Titanium Brush and a Doxycycline-Saline Slurry for Surface Detoxification With Guided Bone Regeneration: A 5-Year Follow-Up. *Clin Adv Periodontics*. https://doi.org/10.1002/cap.10085 · case report/series
20. Badarudhin BBK et al. (2026). Three-year follow-up of a peri-implantitis case managed by titanium brush and tetracycline slurry for surface decontamination with guided bone regeneration. *J Indian Soc Periodontol*. https://doi.org/10.4103/jisp.jisp_395_24 · case report/series
21. Machtei EE et al. (2021). Repeated delivery of chlorhexidine chips for the treatment of peri-implantitis: A multicenter, randomized, comparative clinical trial. *J Periodontol*. https://doi.org/10.1002/JPER.20-0353 · RCT
22. Mellado-Valero A et al. (2013). Decontamination of dental implant surface in peri-implantitis treatment: a literature review. *Med Oral Patol Oral Cir Bucal*. https://doi.org/10.4317/medoral.19420 · review
23. Pranno N et al. (2021). Comparison of the effects of air-powder abrasion, chemical decontamination, or their combination in open-flap surface decontamination of implants failed for peri-implantitis: an ex vivo study. *Clin Oral Investig*. https://doi.org/10.1007/s00784-020-03578-w · RCT
24. El Chaar E et al. (2020). Decontamination of the Infected Implant Surface: A Scanning Electron Microscope Study. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.4568 · in vitro
25. Ichioka Y et al. (2023). Decontamination of biofilm-contaminated implant surfaces: An in vitro evaluation. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14136 · in vitro
26. Lollobrigida M et al. (2022). Efficacy of Combined Mechanical and Chemical Decontamination Treatments on Smooth and Rough Titanium Surfaces and Their Effects on Osteoconduction: An Ex Vivo Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.9105 · in vitro
27. Gosau M et al. (2010). Effect of six different peri-implantitis disinfection methods on in vivo human oral biofilm. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2009.01908.x · in vitro
28. Bürgers R et al. (2012). The effect of various topical peri-implantitis antiseptics on Staphylococcus epidermidis, Candida albicans, and Streptococcus sanguinis. *Arch Oral Biol*. https://doi.org/10.1016/j.archoralbio.2012.01.015 · in vitro
29. Corrêa MMF et al. (2026). Citric acid promotes effective in vitro decontamination of titanium while supporting surface, electrochemical, and biological properties compared with conventional chemical agents. *Dent Mater*. https://doi.org/10.1016/j.dental.2026.09.004 · in vitro
30. Mester A et al. (2025). Surface and Biocompatibility Outcomes of Chemical Decontamination in Peri-Implantitis Management. *Biomedicines*. https://doi.org/10.3390/biomedicines13112748 · in vitro
31. Pogacian-Maier AC et al. (2025). Electrochemical Behavior and Cytocompatibility of Titanium Dental Implants Under Different Chemical Treatments. *Biomedicines*. https://doi.org/10.3390/biomedicines13102457 · not classified
32. de Waal YC et al. (2015). Implant decontamination with 2% chlorhexidine during surgical peri-implantitis treatment: a randomized, double-blind, controlled trial. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12419 · RCT
33. Radu Bolun et al. (2024). Mechanical modification of the implant surface as an adjunctive measure during surgical treatment of peri-implantitis *Journal of Stomatological Medicine*. https://doi.org/10.53530/1857-1328.24.1.09 · clinical study
34. Alotaibi M et al. (2019). The effect of a decontamination protocol on contaminated titanium dental implant surfaces with different surface topography in edentulous patients. *Acta Odontol Scand*. https://doi.org/10.1080/00016357.2018.1504986 · clinical study
35. Mayer Y et al. (2020). A nonsurgical treatment of peri-implantitis using mechanic, antiseptic and anti-inflammatory treatment: 1 year follow-up. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.286 · clinical study
36. Patil C et al. (2022). Effectiveness of Different Chemotherapeutic Agents for Decontamination of Infected Dental Implant Surface: A Systematic Review. *Antibiotics (Basel)*. https://doi.org/10.3390/antibiotics11050593 · systematic review
37. Anca Silvia Dumitriu et al. (2023). The Effectiveness of the Association of Chlorhexidine with Mechanical Treatment of Peri-Implant Mucositis *Healthcare*. https://doi.org/10.3390/healthcare11131918 · review
38. Qian SJ et al. (2024). Impact of surface chemical treatment in surgical regenerative treatment of ligature-induced peri-implantitis: A canine study. *J Periodontol*. https://doi.org/10.1002/JPER.23-0634 · not classified
39. Millas L et al. (2026). Repassivation of Titanium Surface with Different Disinfectants After Implantoplasty: Effects on Corrosion, Ion Release, Cytotoxicity and Bacterial Behaviour-An In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj14090587 · in vitro
40. Padulles-Gaspar E et al. (2023). Effects of Hypochlorous Acid and Hydrogen Peroxide Treatment on Bacterial Disinfection Treatments in Implantoplasty Procedures. *Materials (Basel)*. https://doi.org/10.3390/ma16082953 · clinical study
41. Yeek Herr et al. (2007). Morphologic Change of Implant Surfaces Conditioned with Tetracycline-HCl *Key engineering materials*. https://doi.org/10.4028/www.scientific.net/kem.361-363.853 · not classified
42. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
43. Brunello G et al. (2021). The Effects of Three Chlorhexidine-Based Mouthwashes on Human Osteoblast-Like SaOS-2 Cells. An In Vitro Study. *Int J Mol Sci*. https://doi.org/10.3390/ijms22189986 · in vitro
44. Jin SH et al. (2019). Decontamination methods to restore the biocompatibility of contaminated titanium surfaces. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2019.49.3.193 · in vitro
45. Hart I et al. (2024). Effectiveness of mechanical and chemical decontamination methods for the treatment of dental implant surfaces affected by peri-implantitis: A systematic review and meta-analysis. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.839 · systematic review
46. Frank Schwarz et al. (2015). Efficacy of alternative or adjunctive measures to conventional treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-015-0023-1 · systematic review
47. Zhao R et al. (2022). Adjunctive Use of Active Compounds such as Chlorhexidine in the Nonsurgical Treatment of Peri-Implant Mucositis for Oral Health: A Systematic Review and Meta-Analysis. *Oxid Med Cell Longev*. https://doi.org/10.1155/2022/2312784 · systematic review
48. Sunaina Banu et al. (2021). Local delivery of tetracycline group of drugs as adjuncts to mechanical debridement in peri-implantitis: a systematic review and meta-analysis *Journal of Stomatology*. https://doi.org/10.5114/jos.2021.106679 · systematic review
49. Carcuac O et al. (2017). Surgical treatment of peri-implantitis: 3-year results from a randomized controlled clinical trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12813 · RCT
50. Aušra Ramanauskaitė et al. (2016). Surgical Non-Regenerative Treatments for Peri-Implantitis: a Systematic Review *Journal of Oral and Maxillofacial Research*. https://doi.org/10.5037/jomr.2016.7314 · systematic review
51. Zhi-Bang Li et al. (2022). The Effect of Nonaugmentative Approaches in the Surgical Treatment of Peri-implantitis: A Systematic Review and Network Meta-analysis *The International Journal of Oral & Maxillofacial Implants*. https://doi.org/10.11607/jomi.9211 · systematic review
52. Pliaka D et al. (2026). Adjunctive Antimicrobial Therapy in Peri-Implant Diseases: A Narrative Review. *Reports (MDPI)*. https://doi.org/10.3390/reports9040365 · review
53. Badra Hussain et al. (2021). Peri-Implant Health and the Knowing-Doing Gap—A Digital Survey on Procedures and Therapies *Frontiers in Dental Medicine*. https://doi.org/10.3389/fdmed.2021.726607 · RCT
54. Carral C et al. (2016). Mechanical and chemical implant decontamination in surgical peri-implantitis treatment: preclinical "in vivo" study. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12566 · animal study
55. Valderrama P et al. (2013). Detoxification of implant surfaces affected by peri-implant disease: an overview of surgical methods. *Int J Dent*. https://doi.org/10.1155/2013/740680 · review
56. Valderrama P et al. (2014). Detoxification of Implant Surfaces Affected by Peri-Implant Disease: An Overview of Non-surgical Methods. *Open Dent J*. https://doi.org/10.2174/1874210601408010077 · in vitro

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

9 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “The application of i-PRF after a subgingival debridement using glycine air-polishing shows significant improvement of clinical parameters and a bone level stability for at least six months. However, if we consider that no bleeding on probing is needed to control the disease, none of the implants were considered successfully treated.” — [Laurie Deterville et al. 2025](https://doi.org/10.3389/fdmed.2025.1568889), Frontiers in Dental Medicine; cited 5.
- “However, further investigation through randomised clinical trials is necessary. By adhering to rigorous testing protocols, the development of safe and efficient chemical decontamination strategies can be advanced, benefiting patients and promoting progress in implant dentistry.” — [Hussain B et al. 2023](https://doi.org/10.3390/jfb14080394), J Funct Biomater; cited 11.
- “Patients with peri-implantitis that were treated with an intensive treatment protocol of bi-weekly supragingival plaque removal and local application of chlorhexidine chips had greater mean IPD reduction and greater percentile of sites with IPD reduction of ≥2 mm as compared with bi-weekly supra-gingival plaque removal.” — [Machtei EE et al. 2021](https://doi.org/10.1002/JPER.20-0353), J Periodontol; cited 68.
- “Bacterial biofilm removal from infected implant surfaces was significantly superior for mechanical debridement than chemical decontamination.” — [Pranno N et al. 2021](https://doi.org/10.1007/s00784-020-03578-w), Clin Oral Investig; cited 30.
- “Regardless of agreements in parts, there was no observed consensus on the most effective treatment options for treating peri-implantitis. The experts all agree it is an urgent need for well-designed, long-term follow-up randomised and controlled clinical trials comparing interventions to provide an evidence-based strategy for peri-implant health management.” — [Badra Hussain et al. 2021](https://doi.org/10.3389/fdmed.2021.726607), Frontiers in Dental Medicine; cited 13.
- “the best way to prevent peri-implantitis is to prevent peri-implant mucositis through adherence to supportive periodontal therapy. Treatment of peri-implant diseases depends on local and systemic conditions that affect the success of other treatment options.” — [Rubiel Antonio Marín Jaramillo et al. 2019](https://doi.org/10.17533/udea.rfo.v31n1-2a1), Revista Facultad de Odontología Universidad de Antioquia; cited 5.
- “It is suggested that surgical treatment of peri-implantitis is effective and that outcomes of therapy are affected by implant surface characteristics. Potential benefits of systemic antibiotics are not sustained over 3 years.” — [Carcuac O et al. 2017](https://doi.org/10.1111/jcpe.12813), J Clin Periodontol; cited 230.
- “The use of a 2% CHX solution for implant surface decontamination during resective peri-implantitis therapy does not lead to improved clinical, radiographic, or microbiological results compared with a 0.12% CHX + 0.05% CPC solution.” — [de Waal YC et al. 2015](https://doi.org/10.1111/clr.12419), Clin Oral Implants Res; cited 121.
- “Treatment with PDT in patients with periimplantitis was not associated with major reduction of total anaerobic bacteria on the rough surfaces of dental implants as compared with surgical therapy. A significantly lower proinflammatory index of periimplantitis was observed in the PDT group at 24 weeks of follow-up.” — [Bombeccari GP et al. 2013](https://doi.org/10.1097/01.id.0000433592.18679.91), Implant Dent; cited 100.


## What the systematic reviews and meta-analyses concluded

19 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Despite some positive findings, overall success rates for nonsurgical methods remain variable, highlighting the need for standardized treatment protocols and further research to individualize treatment.” — [Giovanni Battista Menchini-Fabris et al. 2026](https://doi.org/10.1016/j.jdip.2026.100004), Journal of Dental Implants and Prosthodontics; cited 0.
- “Natural-photosensitizer-based PDT appears to be a valuable adjunct to mechanical debridement for peri-implantitis, enhancing microbial control and clinical outcomes. Standardization of PDT protocols and further well-designed clinical trials with extended follow-up periods are warranted to confirm long-term efficacy and inform evidence-based guidelines.” — [Warakomska A et al. 2025](https://doi.org/10.3390/pharmaceutics17040443), Pharmaceutics; cited 20.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “The present results do not demonstrate that one method of decontamination is superior in eliminating bacterial biofilm from titanium disk and implant surfaces.” — [Hart I et al. 2024](https://doi.org/10.1002/cre2.839), Clin Exp Dent Res; cited 36.
- “The data reported for the efficacy of chemotherapeutic agents in cleaning contaminated titanium surfaces are scarce, thus it is not possible to draw a definite conclusion. However, chlorhexidine (CHX) (0.2%, 0.12%), citric acid (40%) and sodium hypochlorite (1%) are the most commonly used chemotherapeutic agents; amongst them, citric acid showed the highest potential for biofilm removal from the contaminated implant …” — [Patil C et al. 2022](https://doi.org/10.3390/antibiotics11050593), Antibiotics (Basel); cited 24.
- “Adjunctive CHX application may have some benefits to improve the efficacy of MD in PiM treatment by reducing IBOP%, IPI, and FMPPD in short-term. But these benefits disappeared at medium- and long-term follow-up. In order to achieve better disease resolution of PiM, adjunctive CHX irrigation with MD may be suggested and has positive potential. Well-designed large clinical trials are needed in future.” — [Zhao R et al. 2022](https://doi.org/10.1155/2022/2312784), Oxid Med Cell Longev; cited 15.

11 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

29 non-randomised clinical studies and 34 case reports or series.

- “Within the limitations of the study design, non-surgical approach with adjunctive use of systemic azithromycin for the treatment of peri-implantitis associated lesions with intrabony defects may lead to significant clinical and radiographic improvements.” — [Leira Y et al. 2026](https://doi.org/10.11607/jomi.11673), Int J Oral Maxillofac Implants; cited 1.
- “The use of an air-water abrasive mixture based on sodium bicarbonate followed by irrigation with 0,01% Miramistin provided the most pronounced reduction in clinical symptoms, stabilization of bone loss, and a decreased need for surgical treatment, which allows it to be recommended for implant surface decontamination in the treatment of peri-implantitis.” — [Elena B. Strandstrem et al. 2026](https://doi.org/10.33667/2078-5631-2026-20-110-115), Medical alphabet; cited 0.
- “Er:YAG laser therapy appears to be effective in reducing probing depth and improving clinical parameters in the management of peri-implantitis, particularly when used as an adjunct to surgical regenerative therapy. Further studies with larger sample sizes and standardized protocols are necessary to confirm its efficacy for oral bacterial decontamination.” — [Salma Adnane et al. 2026](https://doi.org/10.5281/zenodo.21870265), Zenodo (CERN European Organization for Nuclear Research); cited 0.
- “Recent developments, particularly dual-light antibacterial photodynamic therapy that combines blue light and near-infrared light, have shown improved antimicrobial effectiveness and a notable decrease in inflammatory biomarkers.” — [Harish Kumar VV 2025](https://doi.org/10.67091/jrdc.2025.8115), ; cited 0.
- “Effective therapy for early peri-implantitis is systemic treatment of peri-implantitis with antibiotics, antiseptic treatment of peri-implant pockets and local application of "Armenicum" paste has shown its effectiveness and can prevent further development of peri-implantitis.” — [Viktoria Margaryan et al. 2025](https://doi.org/10.33425/2639-9490.1161), Oral Health & Dental Science; cited 0.
- “: For the surgical treatment of peri-implantitis, reconstructive treatment involving mechanical debridement with ultrasonics and chemical decontamination, in addition to resolving peri-implant inflammation, allows for bone reconstruction around the implant. The use of multiple aids, both chemical and mechanical, for decontaminating the implant threads is key to achieving greater predictability in the procedure.” — [Giovanni Barbagallo et al. 2024](https://doi.org/10.29011/2575-9760.001984), Journal of Surgery; cited 2.

23 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

69 in vitro / ex vivo and 5 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “Ti ions and particles were found after instrumentation using SS curettes, Ti curettes, and CV ultrasonic inserts, which may affect the disease etiology and outcomes of peri-implantitis therapy more prominently compared to irradiation methods such as CS ultrasonic inserts, CO2 lasers, or ECY lasers.” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375), Int J Oral Maxillofac Implants; cited 1.
- “All active protocols reduced viable Staphylococcus aureus counts compared with untreated implants. Within the limitations of this single-species in vitro model, Er,Cr:YSGG laser irradiation achieved the greatest reduction, whereas GalvoSurge and CHX resulted in moderate and comparable decreases.” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294), Cureus; cited 0.
- “CHX and HP did not reduce biofilm after 1-min immersion, highlighting limitations of these short exposure protocols. In contrast, CA30 demonstrated a favorable balance between antimicrobial efficacy, controlled surface alterations, and biological effects, supporting its potential as an adjuvant chemical strategy for peri-implantitis treatment.” — [Corrêa MMF et al. 2026](https://doi.org/10.1016/j.dental.2026.09.004), Dent Mater; cited 0.
- “From the perspective of preserving the regenerative potential of MSC-AT, diluted benzyldimethyl-myristoylamino-propylammonium and sodium bicarbonate are the most biocompatible agents for surface decontamination. The use of octenidine dihydrochloride 0.1% + 2-phenoxyethanol 2% and erythritol at clinically relevant concentrations is associated with irreversible damage to progenitor cells.” — [Elena B. Strandstrem et al. 2026](https://doi.org/10.17816/gc704179), Genes and Cells; cited 0.
- “CA and H2O2 improved surface properties after implantoplasty, with CA providing the most favorable combination of corrosion resistance, minimal ion release and antibacterial effect.” — [Millas L et al. 2026](https://doi.org/10.3390/dj14090587), Dent J (Basel); cited 0.
- “The proposed combined treatments were more effective in reducing the vitality of multispecies biofilms on implant surfaces compared to CHX alone.” — [Odeh V et al. 2025](https://doi.org/10.1111/clr.70012), Clin Oral Implants Res; cited 6.

63 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “Pathway analysis showed a treatment-dependent pattern consistent with NRF2-mediated cytoprotective signaling, Th2-associated immune modulation, tissue repair, cell adhesion, and inflammatory responses; we interpreted these pathway findings as predicted molecular associations rather than direct evidence of pathway activation or suppression.” — [Prajapati K et al. 2026](https://doi.org/10.1021/acsbiomaterials.6c01295), ACS Biomater Sci Eng; cited 0.
- “Within the limits of the present study, it may be concluded that - (1) The decontamination procedure is more effective in a commercial one-piece vs. a two-piece dental implant. (2) Mechanical and chemical decontamination outcome is insufficient. Resurfacing improves the decontamination outcome. (3) Decontamination of the turned surface is superior to the rough surface.” — [Liat C et al. 2024](https://doi.org/10.1007/s00784-024-05907-9), Clin Oral Investig; cited 3.
- “It is concluded that decontamination procedures including citric acid gel or rotating titanium brush did not improve outcomes following surgical treatment of experimental peri-implantitis. Results were, however, influenced by the implant surface characteristics.” — [Almohandes A et al. 2022](https://doi.org/10.1111/jcpe.13607), J Clin Periodontol; cited 13.
- “Within the limits of the study, the combination of mechanical and chemical treatment proved to be the most effective treatment for disinfection of the anodized implant surface.” — [Htet M et al. 2016](https://doi.org/10.1902/jop.2016.150615), J Periodontol; cited 56.

1 further animal study entry of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Parameters as stated in the abstracts

- “All of them received non-surgical treatment consisting of submucosal debridement, implant surface decontamination, minor curettage together with submucosal irrigation with 0.12% chlorhexidine digluconate and with the administration of systemic azithromycin (500 mg/day for 3 days).” — [Leira Y et al. 2026](https://doi.org/10.11607/jomi.11673) (clinical study).
- “Surface integrity, electrochemical behavior, and protein adsorption were analyzed after 1-min immersion in phosphate-buffered saline (PBS; control), 0.2% chlorhexidine (CHX), 3% hydrogen peroxide (HP), 1% sodium hypochlorite (SH), and CA (10, 20, 30, and 40%).” — [Corrêa MMF et al. 2026](https://doi.org/10.1016/j.dental.2026.09.004) (in vitro).
- “Materials and Methods: Twenty-five Ti6Al4V implants were exposed to one of the following agents: saline solution, 3% hydrogen peroxide, 40% citric acid, 17% EDTA, and a mixture (1:1) of citric (2%) and phosphoric (1N) acids.” — [Mester A et al. 2025](https://doi.org/10.3390/biomedicines13112748) (in vitro).
- “There was a large heterogeneity of methods for treating PI: (1) resective surgery with osteoplasty and surface debridement (implantoplasty, IP); (2) the use of medications/antiseptic (0.12% chlorhexidine + 0.05% cetylpyridinium chlorine) or acids (phosphoric acid 35%); and (3) adjunctive use of laser.” — [Smail Belasla et al. 2025](https://doi.org/10.11138/oi.v17i1.115) (review).
- “The peri-implant defects were randomly treated by 1 of 3 methods: 0.12% chlorhexidine (CHX test group), 1.5% sodium hypochlorite (NaOCl test group), or saline (Control group).” — [Qian SJ et al. 2024](https://doi.org/10.1002/JPER.23-0634) (not classified).
- “Chemical decontamination was performed by scrubbing solutions of 0.25% sodium hypochlorite (NaClO) and 1.5% hydrogen peroxide (H2O2) around the exposed implant using cotton pellets.” — [Marcos Ribeiro Sallé et al. 2023](https://doi.org/10.11607/prd.5534) (case report/series).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Perisolv** — 5 entries
- **Air-Flow** — 5 entries
- **TiBrush** — 5 entries
- **Perio-Flow** — 3 entries
- **GalvoSurge** — 3 entries
- **i-Brush** — 3 entries
- **Piezon** — 3 entries
- **PrefGel** — 2 entries
- **Ti-Brush** — 2 entries
- **NiTi Brush** — 1 entry
- **Labrida BioClean** — 1 entry
- **BioClean** — 1 entry
- **R-Brush** — 1 entry
- **PerioFlow** — 1 entry
- **LightWalker** — 1 entry
- **AirFlow** — 1 entry
- **AIRFLOW** — 1 entry
- **Waterlase** — 1 entry
- **PeriBrush** — 1 entry
- **Cavitron** — 1 entry

Manufacturers: Straumann (18), EMS (12), Dentsply Sirona (5), Nobel Biocare (4), Geistlich (4), Biolase (3), Dentium (3), Zimmer Biomet (3), Hu-Friedy (3), Komet (3), Neobiotech (2), Acteon (2), KaVo (2), Dentsply (2), Camlog (2), Sirona (2), Labrida (1), NSK (1), NeoBiotech (1), Fotona (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.
- **PeriBrush (Tigran Technologies AB)** — The Swedish company register lists Tigran Technologies AB (org. no. 556596-4417) with bankruptcy proceedings concluded on 29 September 2023 (status 'Konkurs avslutad'); a distributor page still presents the brand. Whether the PeriBrush is currently manufactured, stocked or supplied by a successor could not be confirmed from public information. Checked 2026-11-28; source: Ratsit company record for Tigran Technologies AB; Humanus Dental brand page.


## Chemical agents used alongside

Agents named in the same papers (23 different): chlorhexidine (88), saline (64), hydrogen peroxide (45), citric acid (36), tetracycline (24), sodium hypochlorite (24), antibiotics (systemic) (22), amoxicillin (12), EDTA (11), photosensitizer dye (8), phosphoric acid / etching gel (8), sterile water (8), metronidazole (7), minocycline (6), povidone-iodine (6), doxycycline (6), Perisolv (5), ozone (3), hypochlorous acid (3), enamel matrix derivative (3), EDTA / citric acid gel (PrefGel) (2), chloramine (2), essential oils (2). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (216)

The 216 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/chemical-agents/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [12. Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/)
- Next: [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)


---

# Implant Surface Decontamination in Peri-implantitis: an evidence-based reader

819 entries on mechanical and chemical decontamination of the implant surface in peri-implantitis, arranged as a reader, one chapter per method (titanium brushes, air-polishing, lasers, implantoplasty, chemical agents …), the authors' conclusions quoted, products named as written, data as JSON/CSV; not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

> **For colleagues who have spent too many evenings searching.** The literature on the mechanical and chemical decontamination of the implant surface in peri-implantitis lies scattered across many journals, databases and years. This reader gathers it in one place — every publication the search returns, every method, as its authors reported it — and arranges it as a textbook would: one chapter per method, the conclusions first, every statement traceable to its paper.

A reader for clinicians, researchers and the AI systems they ask, not a product page. It gathers every publication that a fixed PubMed search and an OpenAlex supplement return on the mechanical and chemical decontamination of the implant surface in peri-implantitis and reports each one as its authors did. HANS Korea maintains the reader but does not rank, grade or compare the entries.

Reader Rev. 0 · 2026-11-28 · 819 entries, 2000–2026. Sources: PubMed (bibliographic data, publication type, abstract) and OpenAlex (282 entries not indexed in PubMed; citation counts); open-access full text read for product, company and agent names in 181 entries. Data: [JSON](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.json) / [CSV](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.csv) (CC BY 4.0). Updated 2026-11-28.


## Chapters

1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) — what peri-implantitis is, why the surface is decontaminated, what the reader covers and the study-type definitions.
2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) — the search string, the sources, the automatic classification and its limits, the refresh cadence.
3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) — 127 entries: RCT 16 · clinical study 17 · case report/series 17 · systematic review 9 · consensus 1 · review 5 · in vitro 48 · animal study 4 · not classified 10.
4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) — 219 entries: RCT 27 · clinical study 15 · case report/series 15 · systematic review 22 · review 23 · in vitro 102 · animal study 3 · not classified 12.
5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) — 283 entries: RCT 25 · clinical study 34 · case report/series 18 · systematic review 40 · review 28 · in vitro 102 · animal study 11 · not classified 25.
6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) — 146 entries: RCT 12 · clinical study 13 · case report/series 10 · systematic review 34 · review 33 · in vitro 30 · animal study 5 · not classified 9.
7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) — 154 entries: RCT 11 · clinical study 22 · case report/series 19 · systematic review 23 · consensus 1 · review 13 · in vitro 43 · animal study 7 · not classified 15.
8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) — 148 entries: RCT 15 · clinical study 15 · case report/series 12 · systematic review 15 · review 11 · in vitro 74 · animal study 2 · not classified 4.
9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) — 156 entries: RCT 26 · clinical study 21 · case report/series 24 · systematic review 13 · review 12 · in vitro 54 · animal study 2 · not classified 4.
10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) — 31 entries: RCT 5 · clinical study 2 · case report/series 4 · systematic review 1 · review 5 · in vitro 12 · animal study 1 · not classified 1.
11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) — 30 entries: RCT 1 · clinical study 1 · systematic review 2 · review 5 · in vitro 20 · not classified 1.
12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) — 11 entries: clinical study 1 · case report/series 1 · systematic review 2 · review 3 · in vitro 4.
13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) — 216 entries: RCT 9 · clinical study 29 · case report/series 34 · systematic review 19 · review 35 · in vitro 69 · animal study 5 · not classified 16.
14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) — the conclusions of all 81 systematic reviews and 2 consensus reports, quoted, newest first.
15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) — what the company that compiles this reader states about its own instrument, kept apart from the method chapters; 36 entries name it.
16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) — the terms used in the reader, in plain language.
17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/) — every one of the 819 entries with its quoted conclusion, filterable by study type and method.


## The literature at a glance

*Entries by method and study type (a paper that uses several methods is counted in each)*

| Method (chapter) | RCT | Clinical | Case | SR/MA | Consensus | Review | In vitro | Animal | Not classified | Total |
|---|---|---|---|---|---|---|---|---|---|---|
| [3. Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) | 16 | 17 | 17 | 9 | 1 | 5 | 48 | 4 | 10 | 127 |
| [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) | 27 | 15 | 15 | 22 | 0 | 23 | 102 | 3 | 12 | 219 |
| [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/) | 25 | 34 | 18 | 40 | 0 | 28 | 102 | 11 | 25 | 283 |
| [6. Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) | 12 | 13 | 10 | 34 | 0 | 33 | 30 | 5 | 9 | 146 |
| [7. Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) | 11 | 22 | 19 | 23 | 1 | 13 | 43 | 7 | 15 | 154 |
| [8. Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) | 15 | 15 | 12 | 15 | 0 | 11 | 74 | 2 | 4 | 148 |
| [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) | 26 | 21 | 24 | 13 | 0 | 12 | 54 | 2 | 4 | 156 |
| [10. Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) | 5 | 2 | 4 | 1 | 0 | 5 | 12 | 1 | 1 | 31 |
| [11. Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) | 1 | 1 | 0 | 2 | 0 | 5 | 20 | 0 | 1 | 30 |
| [12. Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) | 0 | 1 | 1 | 2 | 0 | 3 | 4 | 0 | 0 | 11 |
| [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) | 9 | 29 | 34 | 19 | 0 | 35 | 69 | 5 | 16 | 216 |
| All entries | 89 | 96 | 83 | 81 | 2 | 73 | 299 | 28 | 68 | 819 |


## How to read it

- Each method chapter opens with a key-facts box and a working definition, then quotes the conclusions of the randomised trials, the systematic reviews, the consensus reports, the clinical studies and the laboratory studies in turn, lists the operating parameters the abstracts state, the products and manufacturers named, the chemical agents used alongside, the limitations, and ends with that chapter's table of entries.
- Every quotation is the paper's own conclusion, unchanged, with first author, year, journal and a DOI link; nothing is paraphrased into a verdict.
- Every chapter is also published as Markdown: add `.md` to the chapter name (for example [/articles/literature-index/titanium-brush.md](https://www.nitibrush.com/articles/literature-index/titanium-brush.md)), or read all chapters in one file: [reader.md](https://www.nitibrush.com/articles/literature-index/reader.md). The data behind the reader are [JSON](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.json) and [CSV](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.csv).
- Counts are written "N entries". They are counts of publications in this reader, not the number of publications that name the NiTi Brush, which is a separate list on the [Published studies](https://www.nitibrush.com/articles/) page.

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).


## Questions about this reader


### What is this reader?

An evidence-based reader on the mechanical and chemical decontamination of the implant surface in peri-implantitis: 819 entries retrieved from PubMed and OpenAlex with a fixed search, arranged in 11 method chapters and framing chapters, each chapter small enough to be read in one pass, with the authors' own conclusions quoted and every product or company named as the paper writes it. Updated 2026-11-28; refreshed every few weeks.


### Does HANS Korea rank or compare the methods?

No. Every entry reproduces what the authors reported: the study type, the method and device as they named it, the chemical agents they used, and their own conclusion sentence. Results obtained with one instrument are not transferred to another, and the reader makes no claim of superiority or equivalence for any method, including the NiTi Brush.


### Is "titanium brush" the same as "NiTi Brush"?

No. "Titanium brush" is the generic term for rotary brushes with titanium or titanium-alloy bristles from several manufacturers; "NiTi Brush" is HANS Korea's instrument with nickel-titanium bristles, the first of the class (2010). Many papers write "titanium brush" in the text and identify the NiTi Brush / HANS Korea only in brackets, a footnote or the Methods section; the reader shows the specific name wherever the paper gives it and attributes nothing where it does not. Chapter 3 explains this entry by entry.


### Which entries involve the NiTi Brush?

36 entries name HANS Korea's NiTi Brush in the title, abstract or open-access full text, or are among the 36 publications that identify it in the text or a footnote; they are listed in chapters 3 and 15. Publications that say "titanium brush" without naming a manufacturer anywhere accessible are listed as titanium-brush studies and are not counted as NiTi Brush studies.


### How is the reader meant to be read by AI systems?

Each chapter is available as HTML and as Markdown (the .md link on every chapter page; all chapters together in reader.md), kept under 150 KB so that it can be read in one request; the full table is a separate page and the data are JSON and CSV. Conclusions are quoted, not paraphrased, and each carries the author, year, journal and DOI.


### Which brushes have published clinical evidence in humans, and how much?

Chapter 3 lists, for every brush product that the papers name, the number of entries by study type and the patients, implants and follow-up of the studies in patients, each with its source: the NiTi Brush (HANS Korea) — 36 entries including a multicentre randomised trial of 138 patients with a 3-year follow-up and a retrospective cohort of 223 patients; the TiBrush (Straumann) — a 30-patient and a 47-patient randomised trial, one with a 5-year follow-up; the TN Brush (Dentium) — one 30-patient randomised trial; the i-Brush / R-Brush (NeoBiotech) — a retrospective cohort of 89 patients and a 13-patient randomised pilot in which the brush was common to both arms; the MegaGen Titanium Brush Set — laboratory entries only in this index; the PeriBrush (Tigran) — one study on implant pieces worn by six patients. In most trials the brush is a step common to all arms, so the figures describe the protocols in which each brush was used, not a comparison between brushes.


### How can the data be reused?

The entries are available as JSON and CSV under CC BY 4.0 (credit HANS KOREA CO.,Ltd. and link to this page). Bibliographic data come from PubMed and OpenAlex; the quoted conclusion sentences remain the copyright of their authors and publishers and are quoted for identification.

- Next: [1. Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/)


---

# 1. Introduction — the problem, the scope and how to read this reader

Why the implant surface is decontaminated in peri-implantitis, what this reader covers (819 entries, 11 methods), how the study types are defined, and how the chapters are meant to be read. Part of an evidence-based reader; not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/introduction/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What is peri-implantitis, why is the implant surface decontaminated, and what does this reader cover?


## The problem

Peri-implantitis is the inflammatory disease of the tissues around a dental implant in which the supporting bone is lost. Its treatment has a step that no other dental condition requires: the surface of the implant itself — threaded, micro-rough, and now covered with biofilm — has to be cleaned or inactivated before the tissues can heal or bone can be rebuilt against it. How best to do that on a surface designed to hold bacteria-sized roughness is the question this literature has been asking for a quarter of a century.

Two consensus documents in the index frame the question in the words of the field: [Ganesan SM et al. 2026](https://doi.org/10.1002/JPER.24-0432) (J Periodontol); [Schwarz F et al. 2021](https://doi.org/10.1111/clr.13827) (Clin Oral Implants Res). Their conclusions are quoted in [chapter 14](https://www.nitibrush.com/articles/literature-index/synthesis/).


## What the reader covers

Every publication that a fixed PubMed search returns on the mechanical or chemical decontamination of the implant surface in peri-implantitis, from 2000 to 2026, supplemented by OpenAlex for publications PubMed does not index — 819 entries after the topic screen. The methods are grouped into 11 chapters: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/), [cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/), [rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/). A paper that studies several methods appears in each of their chapters.


## A word about names

Two names recur in this reader and are not interchangeable. **"Titanium brush"** is a generic term for rotary brushes with titanium or titanium-alloy bristles from several manufacturers. **"NiTi Brush"** is one manufacturer's instrument (HANS Korea, nickel-titanium bristles, 2010). Many papers write the generic term in the text and identify the NiTi Brush only in brackets, a footnote or the Methods section, so an abstract alone can hide which instrument was used. The reader shows every product and company name exactly where and as the paper gives it, and attributes nothing where the paper names nothing; [chapter 3](https://www.nitibrush.com/articles/literature-index/titanium-brush/#naming) sets this out entry by entry. The same rule applies to every other product in the reader.

The reader does not cover the diagnosis or epidemiology of peri-implantitis, the surgical techniques of bone reconstruction except where a paper reports the decontamination step, the manufacturing surface treatments of new implants, or the prevention of the disease.


## How the study types are defined

Each entry carries one study type, assigned from the PubMed publication type and the wording of the abstract:

**Randomised clinical trial (89)** — A study in patients in which the treatment of each implant or patient was assigned by a random procedure; PubMed publication type "Randomized Controlled Trial", or randomisation stated in the abstract.

**Clinical study (non-randomised) (96)** — A study in patients without random allocation — prospective or retrospective cohort, case–control, before–after series with a stated number of patients or implants.

**Case report / series (83)** — A description of one patient or a small series, without a comparison group; PubMed publication type "Case Reports" or "case report / case series" in the title.

**Systematic review / meta-analysis (81)** — A review that states a systematic search and selection of studies, with or without a pooled statistical analysis; PubMed publication type "Systematic Review" / "Meta-Analysis" or those words in the title.

**Guideline / consensus (2)** — A clinical practice guideline, consensus conference statement or position paper of a professional body.

**Review (73)** — A narrative or scoping review, without the systematic-search criteria of the type above.

**In vitro / ex vivo (299)** — A laboratory study on titanium discs, implant specimens or removed implants, including biofilm models, surface-roughness measurements and cell-culture tests; no patients.

**Animal study (28)** — A study in dogs, minipigs, rats, rabbits or sheep, usually with experimentally induced peri-implantitis.

**Not classified from the abstract (68)** — The record carried no publication type and the abstract gave no wording that fits one of the classes above; the entry is kept in the table, read the paper to place it.


## Entries by year

| Year | Entries |
|---|---|
| 2026 | 100 |
| 2025 | 103 |
| 2024 | 68 |
| 2023 | 84 |
| 2022 | 84 |
| 2021 | 70 |
| 2020 | 55 |
| 2019 | 40 |
| 2018 | 32 |
| 2017 | 36 |
| 2016 | 29 |
| 2015 | 24 |
| 2000–2014 | 94 |


## How to read the chapters

1. Start with the key-facts box: how many papers, of which kinds, which products and agents they name, and which chapters they share papers with.
2. Read the quoted conclusions in order of evidence level — randomised trials, systematic reviews, consensus reports, clinical studies, laboratory studies. Each is the authors' sentence about their own study; a method may be the test, the control or a common step.
3. Check the parameters section for the speeds, powers, times and concentrations the abstracts state, then open the paper for the full protocol.
4. Use the chapter table, the [table of all entries](https://www.nitibrush.com/articles/literature-index/all-entries/) or the CSV/JSON to find a specific paper.
5. Read [chapter 2](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) before citing a count: the counts are of retrieved publications, assigned automatically.


## How to cite

HANS KOREA CO.,Ltd. Implant Surface Decontamination in Peri-implantitis: an evidence-based reader. https://www.nitibrush.com/articles/literature-index/ (updated 2026-11-28). Data CC BY 4.0. Quoted conclusions remain the copyright of their authors and publishers.

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [Overview](https://www.nitibrush.com/articles/literature-index/)
- Next: [2. How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/)


---

# 2. How this reader is made — search, sources, classification, limits

The PubMed search string, the OpenAlex supplement, the automatic classification of study type, method, product, manufacturer and chemical agent, the quoted-conclusion rule, the exclusions, the refresh cadence and the limits of the implant surface decontamination reader (819 entries).

URL: https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

Where do the entries come from, how is each one classified, and what can go wrong?


## Sources and search

1. PubMed (NCBI E-utilities), all records returned by this search, 2000 to the present: `(("peri-implantitis"[tiab] OR periimplantitis[tiab] OR "peri-implant"[tiab]) AND (decontamination[tiab] OR debridement[tiab] OR detoxification[tiab] OR implantoplasty[tiab] OR "air polishing"[tiab] OR "air-polishing"[tiab] OR "air abrasive"[tiab] OR laser[tiab] OR brush[tiab] OR brushes[tiab] OR "surface treatment"[tiab] OR electrolytic[tiab]) AND ("implant surface"[tiab] OR "implant surfaces"[tiab] OR titanium[tiab]) AND 2000:2026[dp]) OR (("titanium brush"[tiab] OR "titanium brushes"[tiab] OR "NiTi brush"[tiab] OR "Ti-brush"[tiab] OR "rotary titanium brush"[tiab] OR "rotating titanium brush"[tiab]) AND (implant*[tiab] OR peri-implant*[tiab]) AND 2000:2026[dp])`
2. OpenAlex, twelve title searches on the same terms, kept only when the title mentions implants, the implant surface or titanium brushes (282 entries not indexed in PubMed); OpenAlex also supplies the citation counts and the open-access flag for every entry.
3. Open-access full text (NCBI PMC), Methods section only, read for 181 entries to pick up product, company and agent names that abstracts omit; marked "(full text)" in the table of all entries.
4. Topic screen: a record is kept only when its title or abstract describes cleaning, decontaminating, debriding or detoxifying an implant surface and at least one method of the dictionary is found. Records about implant manufacturing surfaces, ion release, osseointegration or prevalence are dropped by this screen.


## Classification

- Study type: from the PubMed publication type first (Randomized Controlled Trial, Systematic Review, Meta-Analysis, Practice Guideline, Consensus Development Conference, Review, Case Reports), then from the abstract wording (randomisation and patients; discs, specimens, biofilm models; animal species; patients or cohorts). Definitions are in [chapter 1](https://www.nitibrush.com/articles/literature-index/introduction/).
- Method: a fixed word list of eleven classes (titanium / NiTi brush, air-polishing, laser, photodynamic therapy, implantoplasty, ultrasonic / sonic / piezo, curettes / hand instruments, electrolytic cleaning, cold plasma, rubber cup / paste, chemical / antiseptic agents) matched against title and abstract.
- Product and manufacturer: a fixed list of decontamination products and of companies, reproduced exactly as the paper writes them; a name is shown only when the paper names it.
- Chemical agent: a fixed list of agents (saline, chlorhexidine, hydrogen peroxide, citric acid, tetracycline, doxycycline, minocycline, metronidazole, amoxicillin, EDTA, phosphoric acid, sodium hypochlorite, hypochlorous acid, povidone-iodine, ozone, photosensitiser dyes, chloramine, essential oils, sterile water, enamel matrix derivative, systemic antibiotics).
- Takeaway: the CONCLUSION section of a structured abstract, or the sentences after "In conclusion" / "Within the limitations of this study", or the last two sentences of an unstructured abstract — quoted without change and cut at 420 characters at a sentence end.
- Parameters: one sentence per paper from the abstract when it states a number with a unit (rpm, W, Hz, J/cm², bar, µm, mm, %, mg/mL, s, min) in connection with the chapter's method.


## What is not done

- No ranking, grading, weighting or recommendation. No pooled statistics. No risk-of-bias assessment.
- No comparison between products or manufacturers; results obtained with one instrument are not transferred to another instrument of the same class.
- No paraphrase of results: the quoted conclusion is the paper's own sentence, and the reader's own text describes the methods only.
- Nothing is written by hand into an entry. A wrongly retrieved paper is removed by listing its PubMed identifier in an exclusion file, never by editing its row.


## Refresh and corrections

The search, the supplement and the full-text pass are re-run every two to three weeks at first and monthly thereafter; the whole reader, including every count and quotation, is regenerated from the records each time. Last refresh: 2026-11-28. Corrections — a misclassified study type, a missed product name, an off-topic record — can be sent to info@nitibrush.com with the PMID or DOI; they are applied through the classification rules or the exclusion list, so that the next refresh keeps them.


## Limits

- Coverage depends on the search string: a paper that describes decontamination without one of the search terms in its title or abstract is not retrieved.
- Automatic classification misreads some abstracts; the "Not classified from the abstract" group holds the entries whose record gave no usable publication type or wording.
- A method appears for a paper when the abstract mentions it, which includes comparators and background mentions.
- Citation counts are OpenAlex counts at the time of the refresh and depend on OpenAlex coverage.
- Conclusion sentences are quoted for identification and remain the copyright of their authors and publishers; this reader hosts no paper and links only to DOI landing pages or PubMed.


## Version history of the reader

The reader has its own version number, separate from the revision of the [Published studies](https://www.nitibrush.com/articles/#versions) list: Rev. 0 is the first published edition and each released refresh of the records adds one. A refresh is recorded automatically, with the number of entries added and removed, as an entry in preparation until the update is complete and approved.


### Rev. 0 · 2026-11-28 · 819 entries, 36 name the NiTi Brush · Published studies Rev. 3

- First published edition of the reader: overview, introduction, methods chapter, 11 method chapters with sourced descriptions (every sentence footnoted to an entry), synthesis of all systematic reviews and consensus reports, manufacturer note, glossary, searchable table; each chapter also as Markdown.
- Sources: PubMed topic search, OpenAlex supplement, and the publications of the Published studies list fetched by DOI — 816 entries after merging records that both sources held (same DOI); open-access full text read for 181; all 36 publications of the Published studies list are entries.
- Hand-checked: the 50 most-cited entries (14 corrections of study type, conclusion sentence or method tags); Aoki 2015 reclassified as a review.
- Supersedes the single-table working versions of 28 November 2026 (511 and 793 entries), which were never released.
- Chapter 3: published clinical evidence by named brush (table + reading notes, 6 products); three papers added as a hand-listed supplement (Hwang 2023, Rakašević 2023, Ghaffar 2024); I.C.T. / De Ore wording counted as the NiTi Brush; availability notes for TiBrush and PeriBrush; overview FAQ on published evidence by brush; chapter 15 company statement on the evidence as a whole. (added to Rev. 0 on 2026-11-28 by the CEO's decision; no new number)

Reader Rev. 0 · 2026-11-28 · 819 entries, 2000–2026. Sources: PubMed (bibliographic data, publication type, abstract) and OpenAlex (282 entries not indexed in PubMed; citation counts); open-access full text read for product, company and agent names in 181 entries. Data: [JSON](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.json) / [CSV](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.csv) (CC BY 4.0). Updated 2026-11-28.

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [1. Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/)
- Next: [3. Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/)


---

# 14. Synthesis — what the systematic reviews and consensus reports conclude

The conclusions of all 81 systematic reviews and meta-analyses and 2 consensus reports in the implant surface decontamination reader, quoted in the authors' words, newest first, each with the methods it covers. No pooling, no ranking.

URL: https://www.nitibrush.com/articles/literature-index/synthesis/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What do the systematic reviews and the consensus reports conclude about decontaminating the implant surface, across all methods?

This chapter does not add a conclusion of its own. It places the 2 consensus reports and the 81 systematic reviews or meta-analyses of the index side by side, newest first, each with the methods its abstract covers, so that the reader can see what the field itself has concluded and how that has moved over time. Where the reviews disagree, both are quoted.


### How the review literature has developed

An early systematic review listed removal of granulation tissue and "detoxification of the exposed implant surface" among the components of peri-implantitis therapy[1]. The 2008 Cochrane review found "very little reliable evidence suggesting which could be the most effective interventions for peri-implantitis" and noted that in four trials subgingival mechanical debridement seemed to achieve results similar to more complex therapies[2]. In 2014 a review of mostly in vitro studies concluded that the air abrasive may remove plaque effectively from machined, SLA and TPS surfaces, with positive results also for rotating titanium brushes and ultrasonic scalers with non-metal tips, while "the clinical impact of these findings requires further clarification"[3]. A meta-analysis of the same year found a weighted mean difference of 0.00 mm in probing-depth reduction between laser and conventional decontamination[4]. Reviews of 2015 and 2016 reported that glycine powder air polishing and Er:YAG laser were favoured for bleeding reduction in non-surgical therapy but not in surgery, that no firm conclusion could be drawn on lasers, and that non-surgical therapy gave "modest and not-predictable outcomes" for peri-implantitis[5,6,7].

A 2022 meta-analysis of 16 surgical trials found that all protocols improved clinical parameters, that titanium brushes and implantoplasty showed favourable results as single methods, and that "no single decontamination method demonstrated clear evidence of superiority compared to the others"[8]. A set of 2023 reviews concluded that evidence on mechanical/physical decontamination in non-surgical instrumentation was limited by few studies and high heterogeneity, that adjunctive chemicals may improve probing depth non-surgically but during surgery "cannot be recommended as superior to standard debridement procedures", and that photo/mechanical approaches in surgery were inconclusive although titanium brushes "may be beneficial in reducing signs of inflammation"[9,10,11,12]. An AAP/AO review of 121 non-clinical studies found that "no modality demonstrated significant superiority" for re-osseointegration, that greater biofilm removal was reported with PEEK ultrasonic tips, air-powder abrasion, Er:YAG laser and electrolytic cleaning, and that curettes, ultrasonic tips, titanium brushes and implantoplasty induced significant surface alterations[13].


### Points on which the reviews agree, as they state them

Heterogeneity of protocols is the limitation most often named, precluding statistical analysis or meta-analysis in vitro and in both clinical settings[3,7,9,10]. Several reviews state in their own words that no one method outperforms the others: "still no consensus on which technique performs better", "do not demonstrate that one method of decontamination is superior", and "no agreed-upon gold standard"[14,15,16]. Mechanical debridement is treated as the basis to which other measures are added: one review found it alone effective for mucositis, an in vitro review found it more favourable than laser and chemical methods, and a 2026 meta-analysis called it the step "which remains the gold standard"[5,14,17]. On adjuncts, reviews reported that systemic antibiotics improved bleeding after non-surgical therapy, added to short-term surgical success where Er:YAG laser did not, and, like photodynamic therapy, improved clinical outcomes[18,8,19]. Almost every review calls for larger, longer, well-designed randomised trials[2,6,20,21].


### Points on which the reviews differ or remain open

Lasers show the widest spread: no additional effect over conventional measures, a benefit limited to three months, advantages for Er:YAG in probing depth at 6 and 12 months, a positive influence of solid-state but not diode lasers, and no microbiological difference[22,23,24,25,17]. Chemical agents read differently by setting: an advantage in probing depth non-surgically, none over debridement with or without saline in surgery, and in vitro a difference only between chlorhexidine and buffered saline[10,11,15]. Titanium brushes appear with favourable results as a single surgical method and higher bleeding reduction in one trial, yet with no benefit as an adjunct to implantoplasty, no "clear clinical superiority" over conventional methods, and significant surface alteration on the bench[8,12,21,13]. Implantoplasty was judged free of remarkable short- to medium-term complications, while other reviews listed it among the sources of titanium particles and named particle scatter as a concern for predictability[26,27,28]. Air polishing cleaned effectively in vitro, but its drawback was described as limited restoration of biocompatibility, and clinical meta-analyses found it no more favourable than other modalities[3,29,30]. Whether bench findings carry over to clinical outcome remains open, as the in vitro reviews state, one of them finding no universally safe tool for surface integrity[3,31].


### What the consensus reports say

Group 3 of the 6th EAO Consensus Conference (2021) addressed implant and prosthetic factors and soft-tissue change after surgery, not a comparison of decontamination methods, reporting less recession after reconstructive therapy than after access flap and no influence of implantoplasty on recession[32]. Workgroup 2 of the IADR Implantology Research Group consensus (2026) meta-analysed seven trials on reconstructive biomaterials and concluded that adding them "may not definitively enhance the likelihood of peri-implantitis disease resolution"[33]. Its heterogeneity analysis found a positive effect on radiographic defect level when hydrogen peroxide, but not rotary titanium brushes, was used for surface debridement, and it called for standardised composite outcomes and control of implant-surface effects in future trials[33].


### Sources cited in this description (33)

1. Romeo E et al. (2004). Peri-implant diseases. A systematic review of the literature. *Minerva Stomatol*. https://pubmed.ncbi.nlm.nih.gov/15263878/ · systematic review
2. Esposito M et al. (2008). The efficacy of interventions to treat peri-implantitis: a Cochrane systematic review of randomised controlled clinical trials. *Eur J Oral Implantol*. https://pubmed.ncbi.nlm.nih.gov/20467649/ · systematic review
3. Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12224 · systematic review
4. Mailoa J et al. (2014). Clinical outcomes of using lasers for peri-implantitis surface detoxification: a systematic review and meta-analysis. *J Periodontol*. https://doi.org/10.1902/jop.2014.130620 · systematic review
5. Frank Schwarz et al. (2015). Efficacy of alternative or adjunctive measures to conventional treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-015-0023-1 · systematic review
6. Natto ZS et al. (2015). Comparison of the efficacy of different types of lasers for the treatment of peri-implantitis: a systematic review. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.3846 · systematic review
7. Fernando Suárez et al. (2016). Non-Surgical Therapy for Peri-Implant Diseases: a Systematic Review *Journal of Oral and Maxillofacial Research*. https://doi.org/10.5037/jomr.2016.7313 · systematic review
8. Baima G et al. (2022). Surface decontamination protocols for surgical treatment of peri-implantitis: A systematic review with meta-analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13992 · systematic review
9. Cosgarea R et al. (2023). Efficacy of mechanical/physical approaches for implant surface decontamination in non-surgical submarginal instrumentation of peri-implantitis. A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13762 · systematic review
10. de Waal YCM et al. (2023). Efficacy of chemical approaches for implant surface decontamination in conjunction with sub-marginal instrumentation, in the non-surgical treatment of peri-implantitis: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13749 · systematic review
11. Wilensky A et al. (2023). The efficacy of implant surface decontamination using chemicals during surgical treatment of peri-implantitis: A systematic review and meta-analysis. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13794 · systematic review
12. Ramanauskaite A et al. (2023). Photo/mechanical and physical implant surface decontamination approaches in conjunction with surgical peri-implantitis treatment: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13783 · systematic review
13. Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. *Int J Oral Maxillofac Implants*. https://pubmed.ncbi.nlm.nih.gov/40476898/ · systematic review
14. Francis S et al. (2022). Titanium Surface Decontamination: A Systematic Review of In Vitro Comparative Studies. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.8969 · systematic review
15. Hart I et al. (2024). Effectiveness of mechanical and chemical decontamination methods for the treatment of dental implant surfaces affected by peri-implantitis: A systematic review and meta-analysis. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.839 · systematic review
16. Ki-Jung Jang et al. (2024). Comparison of Air Abrasion and Mechanical Decontamination for Managing Inflammatory Reactions around Dental Implants: A Systematic Review and Meta-Analysis *Applied Sciences*. https://doi.org/10.3390/app14177775 · systematic review
17. Neophytou C et al. (2026). Microbiological Effects of Laser-Assisted Non-Surgical Treatment of Peri-Implantitis: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. *Dent J (Basel)*. https://doi.org/10.3390/dj14010049 · systematic review
18. Aušra Ramanauskaitė et al. (2021). Efficacy of alternative or adjunctive measures to conventional non-surgical and surgical treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-021-00388-x · systematic review
19. Giok KC et al. (2025). Comparative effectiveness of interventions for the treatment of peri-implantitis: A systematic review with network meta-analysis. *J Prosthet Dent*. https://doi.org/10.1016/j.prosdent.2024.03.024 · systematic review
20. Verket A et al. (2023). Non-surgical therapy of peri-implant mucositis-Mechanical/physical approaches: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13789 · systematic review
21. Pappolla Sessa C et al. (2025). Mucositis and Peri-Implant Disease Treatment with Chitosan and Titanium Brushes: A Systematic Review. *J Clin Med*. https://doi.org/10.3390/jcm14238306 · systematic review
22. P. G. Naveen Kumar et al. (2020). Efficacy of different lasers of various wavelengths in treatment of peri-implantitis and peri-implant mucositis: A systematic review and meta-analysis *The Journal of Indian Prosthodontic Society*. https://doi.org/10.4103/jips.jips_144_20 · systematic review
23. Marianna Chala et al. (2020). Adjunctive Use of Lasers in Peri-Implant Mucositis and Peri-Implantitis Treatment: A Systematic Review *Dentistry Journal*. https://doi.org/10.3390/dj8030068 · systematic review
24. Lu Li et al. (2021). The clinical efficacy of Er:YAG lasers in the treatment of peri-implantitis: a systematic review and meta-analysis *Annals of Palliative Medicine*. https://doi.org/10.21037/apm-21-1853 · systematic review
25. Nengwen Huang et al. (2024). The clinical efficacy of laser in the nonsurgical treatment of peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-024-00570-x · systematic review
26. Stavropoulos A et al. (2019). Mechanical and biological complications after implantoplasty-A systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13499 · systematic review
27. Suárez-López Del Amo F et al. (2018). Dental implants-associated release of titanium particles: A systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13372 · systematic review
28. Dos Santos Martins BG et al. (2022). Surgical and Nonsurgical Treatment Protocols for Peri-implantitis: An Overview of Systematic Reviews. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.9659 · systematic review
29. Moharrami M et al. (2019). Effects of air abrasive decontamination on titanium surfaces: A systematic review of in vitro studies. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.12747 · systematic review
30. Bi J et al. (2023). Effect of Air Polishing on the Treatment of Peri-Implant Diseases: A Systematic Review and Meta-Analysis. *J Oral Implantol*. https://doi.org/10.1563/aaid-joi-D-23-00114 · systematic review
31. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
32. Schwarz F et al. (2021). Peri-implantitis: Summary and consensus statements of group 3. The 6th EAO Consensus Conference 2021. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13827 · consensus
33. Ganesan SM et al. (2026). Biomaterials for resolution of peri-implantitis: Consensus report of Workgroup 2 of the IADR Implantology Research Group Best Evidence Consensus Symposium on Peri-Implant Disease and Its Treatment. *J Periodontol*. https://doi.org/10.1002/JPER.24-0432 · consensus

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. The full list of quoted conclusions follows.*


## Consensus reports

- “Current evidence suggests that incorporating reconstructive biomaterials into surgical treatment may not definitively enhance the likelihood of peri-implantitis disease resolution. However, this lack of effect may be due to other factors such as implant surface treatments which may also affect clinical outcomes.” — [Ganesan SM et al. 2026](https://doi.org/10.1002/JPER.24-0432), J Periodontol; cited 4. Methods covered: Titanium / NiTi brush.
- “Prosthesis overcontouring and impaired access to oral hygiene procedures increases risk for peri-implantitis. When indicated, reconstructive peri-implantitis treatment may facilitate the maintenance of post-operative peri-implant soft-tissue levels.” — [Schwarz F et al. 2021](https://doi.org/10.1111/clr.13827), Clin Oral Implants Res; cited 163. Methods covered: Implantoplasty.


## Systematic reviews and meta-analyses, newest first

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3. Methods covered: [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/), [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/), [rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/).
- “Diode laser along with the nonsurgical management of peri-implantitis demonstrated no advantage compared to non-surgical treatment alone. Long term researches with considerable sample size will only enable us to appropriately assess this treatment modality.” — [Amit Kumar et al. 2026](https://doi.org/10.18231/j.ajohas.32321.1791449240), Asian Journal of Oral Health and Allied Sciences; cited 0. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “Current evidence consistently indicates that saliva contamination may adversely affect early biological responses and the osseointegration process by altering titanium surface properties, particularly surface wettability and surface energy. However, as these data are largely derived from in vitro and animal models, caution is warranted when extrapolating the findings to clinical practice.” — [Çi̇ftçi̇ S et al. 2026](https://doi.org/10.1186/s12903-026-08289-4), BMC Oral Health; cited 0. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Despite some positive findings, overall success rates for nonsurgical methods remain variable, highlighting the need for standardized treatment protocols and further research to individualize treatment.” — [Giovanni Battista Menchini-Fabris et al. 2026](https://doi.org/10.1016/j.jdip.2026.100004), Journal of Dental Implants and Prosthodontics; cited 0. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “PDT exerted the most stable short-term efficacy for peri-implantitis. DL and Er:YAG had limited valid benefits. Due to insufficient long-term data, the sustained effects of these treatments and their roles in preventing lesion recurrence and maintaining implant survival are still undetermined.” — [Zhe Wang et al. 2026](https://doi.org/10.1097/md.0000000000051256), Medicine; cited 0. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Natural-photosensitizer-based PDT appears to be a valuable adjunct to mechanical debridement for peri-implantitis, enhancing microbial control and clinical outcomes. Standardization of PDT protocols and further well-designed clinical trials with extended follow-up periods are warranted to confirm long-term efficacy and inform evidence-based guidelines.” — [Warakomska A et al. 2025](https://doi.org/10.3390/pharmaceutics17040443), Pharmaceutics; cited 20. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “PDT enhances antimicrobial efficacy in peri-implant disease treatment, significantly improving PPD, CBL, and BoP when combined with MD. However, due to the overall moderate-to-low certainty of the evidence and some concerns regarding risk of bias in the included studies, these findings should be interpreted with caution.” — [Yumeng Yan et al. 2025](https://doi.org/10.3389/froh.2025.1614982), Frontiers in Oral Health; cited 17. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Mechanical debridement with adjunctive systemic antibiotics or photodynamic therapy results in improved clinical outcomes.” — [Giok KC et al. 2025](https://doi.org/10.1016/j.prosdent.2024.03.024), J Prosthet Dent; cited 10. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Adjunct PDT significantly enhanced clinical outcomes, particularly for the short-term, with the most notable benefits observed in BOP, PD, PI, and CBL reductions. However, additional benefits in CAL, mucosal recession, and inflammatory biomarkers outcomes remain limited. Standardized protocols and long-term studies are warranted.” — [Murali Srinivasan et al. 2025](https://doi.org/10.1016/j.jdent.2025.105680), Journal of Dentistry; cited 10. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Titanium particles generated during implantoplasty are detectable but show no consistent clinical association with peri-implantitis or significant inflammation. Implantoplasty may be applied selectively, although robust long-term clinical studies are still required. No protocol was registered.” — [Rodríguez Alvarez MB et al. 2025](https://doi.org/10.3390/jcm14248661), J Clin Med; cited 8. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Dental implants are integral to modern oral rehabilitation, providing an effective means of replacing missing teeth and significantly improving the quality of life for many individuals.1 While they demonstrate a high success rate, their longevity is contingent upon proper maintenance and proactive management of complications.” — [Karthikeyan Murthykumar et al. 2025](https://doi.org/10.5005/jp-journals-10015-2522), World Journal of Dentistry; cited 6. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “These findings provide strong evidence for integrating photodynamic therapy into peri-implantitis management protocols, offering a promising, minimally invasive alternative to conventional treatments. Future studies should focus on optimizing photodynamic therapy protocols, assessing long-term outcomes, and evaluating its effectiveness in diverse patient populations.Clinical trial number: PROSPERO (CRD42024600326).” — [Xin Li et al. 2025](https://doi.org/10.1007/s10103-025-04612-7), Lasers in Medical Science; cited 6. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “High heterogeneity, diagnostic variability, and the low number of included studies increase the need of well-designed RCTs on the topic. Despite no conclusive evidence could be found, adjunctive aPDT showed a promising trend to improve MD results.” — [Nastri L et al. 2025](https://doi.org/10.3390/dj13120567), Dent J (Basel); cited 4. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “This approach shows promise in reducing inflammation and promoting healing. Nonetheless, further high-quality research is necessary to confirm long-term benefits and establish clear clinical guidelines for its use.” — [Narjiss Akerzoul et al. 2025](https://doi.org/10.2174/0118742106400224250724113341), The Open Dentistry Journal; cited 3. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “the tungsten carbide drills resulted in less fracture resistance loss than the diamond and tungsten carbide drills for the dental implants submitted to implantoplasty procedures. Systematic Review Registration: \[http://www.prisma-statement.org\], identifier \[INPLASY202460018\].” — [Giovanni Pissu et al. 2025](https://doi.org/10.3389/fdmed.2025.1568465), Frontiers in Dental Medicine; cited 2. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Implantoplasty reduces the mechanical strength of dental implants. Increased implantoplasty length correlates with decreased resistance, particularly affecting narrow implants. The prosthetic connection most affected by this procedure is the external hexagon, followed by the internal hexagon, with the conical connection being the most resistant.” — [Manuel Alejandro León Velastegui et al. 2025](https://doi.org/10.3390/jcm14176103), Journal of Clinical Medicine; cited 2. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Both PDT and laser therapy are effective in reducing the microbial load. Additionally, laser causes the least surface alterations, with some studies reporting minor improvements in implant surface properties.” — [Maedeh Masoumzadeh et al. 2025](https://doi.org/10.18502/fid.v22i49.20330), Frontiers in Dentistry; cited 0. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/), [cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/).
- “The present results do not demonstrate that one method of decontamination is superior in eliminating bacterial biofilm from titanium disk and implant surfaces.” — [Hart I et al. 2024](https://doi.org/10.1002/cre2.839), Clin Exp Dent Res; cited 36. Methods covered: [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Despite the ranking established by our study in the treatment of peri-implant disease, decisions should still be made with reference to the latest treatment guidelines. There is still a need for more high-quality studies to provide conclusive evidence and especially a need for studies regarding direct comparisons between multiple treatment options.” — [Yingjie Bai et al. 2024](https://doi.org/10.1371/journal.pone.0305342), PLoS ONE; cited 24. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Leave-one-out analysis confirmed the stability of the results. The findings highlight the need for future research with longer-term follow-up and high-quality, multi-center, large-sample RCTs.” — [Nengwen Huang et al. 2024](https://doi.org/10.1016/j.jdsr.2024.05.003), Japanese Dental Science Review; cited 18. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/).
- “In the nonsurgical treatment of peri-implantitis, solid-state lasers yielded positive influence in term of PD, BOP and CAL, while diode laser provided no beneficial effect. Future well-designed large RCTs are still needed, considering the limitations of included studies.” — [Nengwen Huang et al. 2024](https://doi.org/10.1186/s40729-024-00570-x), International Journal of Implant Dentistry; cited 16. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “A great variety of photosensitizers were observed, and it was concluded that the selection of the most appropriate type of photosensitizer must consider the patient's characteristics and peri-implantitis conditions.” — [Thaís B. M. O. Schweigert et al. 2024](https://doi.org/10.3390/pharmaceutics16030307), Pharmaceutics; cited 16. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “The findings of the study indicate that the use of air abrasion was just as effective as other mechanical decontamination methods in reducing probing depth and alveolar bone loss. The subgroup analysis showed that air abrasion was less effective in reducing probing depth in maintenance purposes. Additionally, air abrasion was less effective in reducing alveolar bone loss in surgical approaches.” — [Ki-Jung Jang et al. 2024](https://doi.org/10.3390/app14177775), Applied Sciences; cited 2. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/).
- “Despite the limited number of included studies and the significant heterogeneity among them, the findings suggest that aPDT yields comparable peri-implant clinical and radiographic outcomes to adjunctive antibiotic therapy, as adjuncts to MD, for the potential treatment of peri-implant diseases.” — [Aseri AA 2024](https://doi.org/10.1089/photob.2023.0157), Photobiomodul Photomed Laser Surg; cited 1. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Smoking negatively impacts the treatment outcomes of peri-implantitis, with smokers showing heightened inflammatory responses and less improvement in clinical parameters. Clinicians should consider smoking status when planning treatment protocols for peri-implantitis to optimize patient outcomes. Further research is warranted to develop targeted interventions for this vulnerable population.” — [Hamed Mousa H. Bakri et al. 2024](https://doi.org/10.36348/sjodr.2024.v09i10.005), Saudi Journal of Oral and Dental Research; cited 1. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Available evidence on the efficacy of non-surgical submarginal peri-implant instrumentation with mechanical/physical decontamination is limited by the small number of controlled studies and the high heterogeneity of study protocols. Clinical and patient-reported benefits remain to be demonstrated.” — [Cosgarea R et al. 2023](https://doi.org/10.1111/jcpe.13762), J Clin Periodontol; cited 103. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/).
- “Several mechanical/physical instrumentation procedures including curettes, ultrasonics, lasers, rotating brushes and air-polishing are documented; however, a beneficial effect over oral hygiene instructions alone or superiority over other procedures could not be demonstrated. Moreover, it remains unclear whether combinations of different procedures or their repetition over time may provide additional benefits.” — [Verket A et al. 2023](https://doi.org/10.1111/jcpe.13789), J Clin Periodontol; cited 62. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/).
- “Adjunctive chemical approaches for implant surface decontamination may offer an advantage over sub-marginal instrumentation alone, in terms of improved PD.” — [de Waal YCM et al. 2023](https://doi.org/10.1111/jcpe.13749), J Clin Periodontol; cited 55. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Within the limitations of this systematic review and the meta-analysis, adjunctive use of chemicals such as PDT, CHX, and LAbs for surface decontamination during surgery of peri-implantitis cannot be recommended as superior to standard debridement procedures (mechanical debridement with or without saline).” — [Wilensky A et al. 2023](https://doi.org/10.1111/jcpe.13794), J Clin Periodontol; cited 51. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Owing to the limited available data, clinical efficacy of photo/mechanical and physical implant surface decontamination in conjunction with surgical peri-implantitis therapy is inconclusive. However, titanium brushes may be beneficial in reducing signs of inflammation.” — [Ramanauskaite A et al. 2023](https://doi.org/10.1111/jcpe.13783), J Clin Periodontol; cited 44. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Within the limitation of this systematic review and NMA, AT was superior to OFD in improving peri-implantitis outcomes. While adjunct use of ozone therapy may further improve the efficacy of AT, the limited evidence supporting this combination therapy argues for cautionary interpretation of these results.” — [Jing Cheng et al. 2023](https://doi.org/10.1186/s12903-023-02956-6), BMC Oral Health; cited 35. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Surgical regenerative treatment was a predictable option in the management of PI and in improving the clinical parameters of peri-implant tissues in the short term, mainly when using porous titanium granules, alloplastic bone grafts, and xenografts.” — [Castro F et al. 2023](https://doi.org/10.1016/j.sdentj.2023.05.022), Saudi Dent J; cited 32. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Implantoplasty has been recommended as an efficacious treatment protocol for peri-implantitis that helps to diminish the inflammation and accompanied by a high success rate.” — [Dasgupta D et al. 2023](https://doi.org/10.4103/jips.jips_102_23), J Indian Prosthodont Soc; cited 19. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Given that high heterogeneity in BOP and PD outcome was found in this systematic review, future long-term CTs with MD + aPDT should be examined to arrive at a firm conclusion.” — [Shima Afrasiabi et al. 2023](https://doi.org/10.1186/s12903-023-03337-9), BMC Oral Health; cited 13. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “The existing evidence regarding the use of laser for peri-implant mucositis is inconclusive, whereas for peri-implantitis, the majority of the studies support the use of lasers. Future trials should utilize the 2018 classification of peri-implantitis, so that a comparison of trials based on the studied parameters would be more accurate.” — [Amna Mohamed Abdulla AlMarzooqi et al. 2023](https://doi.org/10.2174/18742106-v17-e230517-2022-143), The Open Dentistry Journal; cited 10. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “However, conflicting outcomes and limitations in the evidence quality warrant caution in drawing definitive conclusions. Based on the limited available evidence, laser therapy may show a higher degree of re-osseointegration of implants than mechanical debridement.” — [Patil S et al. 2023](https://doi.org/10.1007/s10103-023-03860-9), Lasers Med Sci; cited 10. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “The standardized mean difference with a 95% confidence interval of the studied parameters was estimated using the random effect model; however, statistical differences were not detected between air polishing and comparative modalities in the treatment of peri-implantitis.” — [Bi J et al. 2023](https://doi.org/10.1563/aaid-joi-D-23-00114), J Oral Implantol; cited 7. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/).
- “Due to methodological heterogeneity, such as non-standard control groups and laser parameters, this systematic review demonstrated inconclusive findings in terms of the efficacy of Er:YAG laser as a debridement method in surgical treatment of advanced peri-implantitis.” — [Lei Li et al. 2023](https://doi.org/10.3290/j.ohpd.b3818041), PubMed Central; cited 7. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “are difficult to generalize due to the heterogeneity in the methodology of the included studies. However, this systematic review suggests that aPDT alongside mechanical debridement demonstrated greater improvements in the PI and PD. Other factors besides the laser therapy itself may account for these findings. As for BoP index, PT demonstrated greater improvements due to its photo-biomodulating effects.” — [R. Sánchez-Martos et al. 2023](https://doi.org/10.4317/jced.60711), Journal of Clinical and Experimental Dentistry; cited 5. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “No single decontamination method demonstrated clear evidence of superiority compared to the others. Systemic antibiotics, but not Er:Yag laser, may provide short-term clinical benefits in terms of treatment success (CRD42020182303).” — [Baima G et al. 2022](https://doi.org/10.1111/clr.13992), Clin Oral Implants Res; cited 122. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Therefore, resective surgical and implantoplasty techniques demonstrated significant improvements in clinical parameters. Although surgical interventions are more indicated to treat peri-implantitis than nonsurgical procedures, the predictability is still a concern due to titanium particles scattered within the local tissue.” — [Dos Santos Martins BG et al. 2022](https://doi.org/10.11607/jomi.9659), Int J Oral Maxillofac Implants; cited 54. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Within the limits of this systematic review, laser treatment may promote bone gain in peri-implantitis defects, may reduce BOP and PDs, and may be comparable to mechanical therapy. However, definitive conclusions can only be made with statistically significant data, which were found lacking in the currently available studies.” — [Miriam Ting et al. 2022](https://doi.org/10.3390/dj10020020), Dentistry Journal; cited 37. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “In the management of peri-implant mucositis, the combined use of diode laser and mechanical debridement did not provide any additional clinical advantage over mechanical debridement alone. Long-term, well-designed RCTs are still needed.” — [Momen A. Atieh et al. 2022](https://doi.org/10.1016/j.identj.2022.06.026), International Dental Journal; cited 29. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “Surgical interventions were more effective at reducing probing pocket depth and bleeding on probing both in the short- and long-term. Surgical treatment in combination with EMD was found to be more effective in resolving inflammation up to twelve months.” — [Haniyeh Moaven et al. 2022](https://doi.org/10.3390/ijerph192114085), International Journal of Environmental Research and Public Health; cited 24. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “The data reported for the efficacy of chemotherapeutic agents in cleaning contaminated titanium surfaces are scarce, thus it is not possible to draw a definite conclusion. However, chlorhexidine (CHX) (0.2%, 0.12%), citric acid (40%) and sodium hypochlorite (1%) are the most commonly used chemotherapeutic agents; amongst them, citric acid showed the highest potential for biofilm removal from the contaminated implant …” — [Patil C et al. 2022](https://doi.org/10.3390/antibiotics11050593), Antibiotics (Basel); cited 24. Methods covered: [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “This review demonstrated that there is still no consensus on which technique performs better. However, mechanical decontamination yielded more favorable results than laser and chemical methods. This aspect would support the hypothesis that decontamination procedures adopted in a combination fashion, which includes mechanical procedures, may provide better clinical results than when used alone.” — [Francis S et al. 2022](https://doi.org/10.11607/jomi.8969), Int J Oral Maxillofac Implants; cited 22. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Adjunctive CHX application may have some benefits to improve the efficacy of MD in PiM treatment by reducing IBOP%, IPI, and FMPPD in short-term. But these benefits disappeared at medium- and long-term follow-up. In order to achieve better disease resolution of PiM, adjunctive CHX irrigation with MD may be suggested and has positive potential. Well-designed large clinical trials are needed in future.” — [Zhao R et al. 2022](https://doi.org/10.1155/2022/2312784), Oxid Med Cell Longev; cited 15. Methods covered: [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/).
- “Data from this study suggested that applying implantoplasty during a regeneration or nonregeneration surgical approach resulted in a high implant survival rate and peri-implantitis resolution. Although no differences were found in the majority of clinical parameters in both groups, the regenerative approach resulted in more radiographic bone fill than the nonregenerative treatment.” — [Cho‐Ying Lin et al. 2022](https://doi.org/10.11607/jomi.9436), The International Journal of Oral & Maxillofacial Implants; cited 12. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Within the limits of this NMA, we found that adjunctive PDT achieved a small additional benefit on PPD reduction and MBL gain compared with CMD alone and had the highest probability of being ranked first on the changes in PPD, MBL and CAL. PDT+CMD may represent an alternative method for peri‑implant treatment.” — [Yao Lin et al. 2022](https://doi.org/10.1016/j.pdpdt.2022.103106), Photodiagnosis and Photodynamic Therapy; cited 11. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Within the limitations of this systematic review and NMA, implantoplasty is more effective than hand curettes in improving PD in the surgical treatment of peri-implantitis. Chemical antiseptics or systemic antibiotics have a limited effect on improving PD and MBL.” — [Zhi-Bang Li et al. 2022](https://doi.org/10.11607/jomi.9211), The International Journal of Oral & Maxillofacial Implants; cited 5. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Methodological differences between the available studies did not allow for clear comparison between them. Furthermore, the limited amount of clinical reports of this resective procedure, in combination with patient and operator variability, affect the clinical assessment of this treatment modality.” — [Rayner Goh et al. 2022](https://doi.org/10.31436/ijohs.v3i1.113), International Journal of Orofacial and Health Sciences; cited 2. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Alternative and adjunctive measures provided no beneficial effect in resolving peri-implant mucositis, while alternative measures were superior in reducing BOP values following non-surgical treatment of peri-implantitis.” — [Aušra Ramanauskaitė et al. 2021](https://doi.org/10.1186/s40729-021-00388-x), International Journal of Implant Dentistry; cited 198. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “The findings suggest that most of the decontamination methods were effective in preventing the formation of biofilm and in decontaminating established biofilm on dental implants. This narrative review provides a summary of methods for future research in the development of new dental implants and decontamination techniques.” — [Dhaliwal JS et al. 2021](https://doi.org/10.3389/fcimb.2021.736186), Front Cell Infect Microbiol; cited 87. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “The lasers showed positive results, on average, after 6 months of follow-up. Comparative clinical trials conducted with the aim to test the efficiency of laser irradiation, in addition to conventional therapy, indicate that this technique can induce similar results if compared to conventional therapy alone.” — [Massimo Pisano et al. 2021](https://doi.org/10.3390/app11115290), Applied Sciences; cited 39. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “DISCUSSION: Our research supported the premise that Er:YAG lasers offer health benefits to patients with peri-implantitis and can effectively reduce PD and GR. Due to the limitations of the included studies, further studies should be carried out to validate our findings.” — [Lu Li et al. 2021](https://doi.org/10.21037/apm-21-1853), Annals of Palliative Medicine; cited 32. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.” — [González FJ et al. 2021](https://doi.org/10.3390/dj9080084), Dent J (Basel); cited 18. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution.” — [Tan NCP et al. 2021](https://doi.org/10.5051/jpis.2005080254), J Periodontal Implant Sci; cited 17. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/).
- “The RecPI and LoPI are similar and low, 3% and 4%, respectively. After 12 months of follow-up RecPI and LoPI are low but LoPI increases to 36% at the long term follow up. Results should be interpreted with caution due to heterogeinity.” — [Orlando Martins et al. 2021](https://doi.org/10.21037/fomm-20-88), Frontiers of Oral and Maxillofacial Medicine; cited 4. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “Peri-implantitis is associated with bone loss around a dental implant.Apart from mechanical factors, microbial etiology with gram-negative anaerobic infection is implied.The condition can have a favorable prognosis with timely control of infection, implant surface detoxification, and bone regeneration.Further, since it is site-specific, there is a potential for targeted form of antimicrobial therapy.Tetracycline has …” — [Sunaina Banu et al. 2021](https://doi.org/10.5114/jos.2021.106679), Journal of Stomatology; cited 0. Methods covered: [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Within the limitations of this study, the adjunctive use of lasers in the treatment of peri-implant inflammation is effective for up to three months; there is no strong evidence regarding the long term benefit compared to conventional treatment.” — [Marianna Chala et al. 2020](https://doi.org/10.3390/dj8030068), Dentistry Journal; cited 43. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “All studies included showed an improvement in clinical conditions after surgical regenerative treatment for peri-implantitis. However, no study has shown any statistical significance in its approach. There is a lack of scientific evidence in literature regarding which type of bone substitute has superiority in the treatment of peri-implantitis, as well as the role of barrier membranes, methods for detoxification of …” — [Aljohani M et al. 2020](https://doi.org/10.1016/j.sdentj.2019.10.006), Saudi Dent J; cited 38. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Laser treatment as an adjunctive therapy or monotherapy in peri implantitis does not show any superior effects than conventional measures as per evidence. However, cases with peri implant mucositis have shown far more promising results with laser therapy compared to peri implantitis.” — [P. G. Naveen Kumar et al. 2020](https://doi.org/10.4103/jips.jips_144_20), The Journal of Indian Prosthodontic Society; cited 14. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Based on all currently available, yet limited, preclinical in vivo and clinical evidence, implantoplasty seems not associated with any remarkable mechanical or biological complications on the short- to medium-term.” — [Stavropoulos A et al. 2019](https://doi.org/10.1111/clr.13499), Clin Oral Implants Res; cited 105. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “AA can efficiently remove contamination without serious damage to the surface. The main drawback of the AA method seems to be its limitation in restoring the biocompatibility of the surface.” — [Moharrami M et al. 2019](https://doi.org/10.1111/cid.12747), Clin Implant Dent Relat Res; cited 65. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/).
- “aPDT may provide similar clinical improvements in PD and CAL when compared with conventional periodontal therapy for both periodontitis and peri-implantitis patients. The restricted base of evidence for some treatment approaches and conditions precludes additional conclusions.” — [Chambrone L et al. 2018](https://doi.org/10.1902/jop.2017.170172), J Periodontol; cited 285. Methods covered: [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Ti particles surrounding peri-implant tissues are a common finding. Peri-implantitis sites presented a higher number of particles compared to healthy implants. The particles were mostly around the implants and inside epithelial cells, connective tissue, macrophages, and bone.” — [Suárez-López Del Amo F et al. 2018](https://doi.org/10.1111/clr.13372), Clin Oral Implants Res; cited 211. Methods covered: [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Promising results were observed in the studies that used combination of bone substitutes together with guided bone regeneration for the regenerative therapy. Regarding implant surfaces, better re-osseointegration was observed with rough implant surfaces rather than smooth ones.” — [Madi M et al. 2018](https://doi.org/10.1097/ID.0000000000000712), Implant Dent; cited 59. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “Non-surgical treatment for peri-implant mucositis seems to be effective while modest and not-predictable outcomes are expected for peri-implantitis lesions. Limitations include different peri-implant diseases definitions, treatment approaches, as well as different implant designs/surfaces and defect characteristics.” — [Fernando Suárez et al. 2016](https://doi.org/10.5037/jomr.2016.7313), Journal of Oral and Maxillofacial Research; cited 200. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/).
- “Surgical therapy in combination with osseous resective or regenerative approach removes the residual sub-gingival deposits additionally reducing the peri-implantitis pocket. Although there is no specific recommendation for the treatment of peri-implantitis, surgical therapy in combination with osseous resective or regenerative approach showed the positive outcome.” — [Mahato N et al. 2016](https://doi.org/10.1186/s40064-016-1735-2), Springerplus; cited 142. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/).
- “Surgical non-regenerative treatment of peri-implantitis was found to be effective to reduce the soft tissue inflammation and decrease probing depth. More randomized controlled clinical trials are needed to assess the efficacy of surgical non-regenerative therapy of peri-implantitis.” — [Aušra Ramanauskaitė et al. 2016](https://doi.org/10.5037/jomr.2016.7314), Journal of Oral and Maxillofacial Research; cited 64. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/).
- “While mechanical debridement alone was found to be effective for the management of peri-implant mucositis, alternative/adjunctive measures may improve the efficacy over/of conventional nonsurgical treatments at peri-implantitis sites. Adjunctive resective and/or augmentative measures are promising; however, their beneficial effect on the clinical outcome of surgical treatments needs to be further investigated.” — [Frank Schwarz et al. 2015](https://doi.org/10.1186/s40729-015-0023-1), International Journal of Implant Dentistry; cited 190. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “Although lasers have shown promising results in reducing clinical signs of peri-implantitis, because of the limited sample sizes and short follow-up periods, no firm conclusion can be drawn at this moment. Hence, there is a need for more well-designed, longitudinal, randomized controlled clinical trials.” — [Natto ZS et al. 2015](https://doi.org/10.11607/jomi.3846), Int J Oral Maxillofac Implants; cited 73. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/).
- “A case report of guided bone regeneration in sites with implants affected by peri-implantitis was presented. Surgical treatment of peri-implantitis, though demanding and not supported by a wide scientific literature, could be considered a viable treatment option if an adequate decontamination of infected surfaces could be obtained.” — [Taschieri S et al. 2015](https://doi.org/10.1155/2015/802310), ScientificWorldJournal; cited 22. Methods covered: [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/), [implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “The available data suggest that the air abrasive may remove plaque effectively from machined, SLA and TPS titanium surfaces. Positive results were also observed for rotating titanium brushes on SLA surfaces and ultrasonic scalers with non-metal tip on polished and SLA surfaces. However, the clinical impact of these findings requires further clarification.” — [Louropoulou A et al. 2014](https://doi.org/10.1111/clr.12224), Clin Oral Implants Res; cited 153. Methods covered: [titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/), [air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/), [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/), [rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/).
- “In animal studies, laser-treated rough-surface implants had a higher percentage of bone-to-implant contact than smooth-surface implants. In a short-term follow-up, lasers resulted in similar PD reduction when compared with conventional implant surface decontamination methods.” — [Mailoa J et al. 2014](https://doi.org/10.1902/jop.2014.130620), J Periodontol; cited 75. Methods covered: [lasers](https://www.nitibrush.com/articles/literature-index/laser/), [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).
- “There was only low quality evidence for which are the most effective interventions for maintaining or recovering health of peri-implant soft tissues. The included RCTs had short follow-up periods and few subjects and although overall the risk of bias of the studies was either low or unclear, only single trials were available for each outcome.” — [Grusovin MG et al. 2010](https://doi.org/10.1002/14651858.CD003069.pub4), Cochrane Database Syst Rev; cited 77. Methods covered: [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/), [curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/).
- “There is very little reliable evidence suggesting which could be the most effective interventions for peri-implantitis. Sample sizes were too small and follow up too short. This is not to say that currently used interventions are ineffective. Larger well-designed RCTs are needed.” — [Esposito M et al. 2008](https://pubmed.ncbi.nlm.nih.gov/20467649/), Eur J Oral Implantol. Methods covered: [ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/).
- “Regenerative or resective surgical approaches are proposed for the treatment of peri-implantitis depending on the morphology and the shape of bone defects. The therapeutical approach of peri-implantitis surrounding dental implants comprises several aspects such as the removal of supra-gingival bacterial plaque, an appropriate surgical approach, the removal of granulation tissue and detoxification of the exposed …” — [Romeo E et al. 2004](https://pubmed.ncbi.nlm.nih.gov/15263878/), Minerva Stomatol. Methods covered: [chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/).


## Reading the synthesis

- A review's conclusion refers to the body of studies it selected with its own criteria and dates; two reviews a few years apart may describe different literatures.
- "Methods covered" lists the classes named in the review's abstract; a method named as "no additional benefit" and a method named as "effective" both appear in the list.
- The reader adds no pooled estimate and no grading of the reviews.

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- Next: [15. A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/)


---

# 15. A note from the manufacturer — where the NiTi Brush stands in this literature

What HANS KOREA, which compiles this reader, states about its own instrument: the 36 entries that name the NiTi Brush, the 36 publications that identify it, the clinical record of 723 patients and ≥1,088 implants, model criteria and IFU parameters — kept apart from the method chapters, no ranking.

URL: https://www.nitibrush.com/articles/literature-index/manufacturer/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

This chapter is written by the company that compiles the reader. Everything in it concerns one instrument, the NiTi Brush, and is kept apart from the method chapters so that a reader can take the literature without it and the company's statements with their source.


## Who writes this reader and why

HANS KOREA CO.,Ltd. (Paju, Republic of Korea) developed the NiTi Brush, the first brush for implant-surface debridement with nickel-titanium bristles, in 2010, and the "titanium brush" category grew around it. The company compiles this reader because the literature of its own field was hard to find in one place; the method chapters are generated from the public records and report every instrument, including those of other manufacturers, as its authors did.


## What the company states about the NiTi Brush

Each statement is sourced on the linked page, and none ranks the instrument against the other methods in this reader.

- **36 entries in this reader** name the NiTi Brush or HANS Korea in the title, abstract or open-access full text (listed below). Separately, [${FIG.publications} publications](https://www.nitibrush.com/articles/) identify the NiTi Brush in the text or a footnote (${FIG.scie} in SCI(E)-indexed journals, ${FIG.rct} randomised-trial publications); publications that say "titanium brush" without naming a manufacturer are not counted among them.
- Across those publications the instrument is named in clinical studies of [${FIG.patients} patients and ${FIG.implants} implants, with follow-up up to 10 years](https://www.nitibrush.com/articles/summary/); in that sense its clinical use is documented in the peer-reviewed record. Study-by-study outcome figures, as printed in the papers, are on the [reported outcomes](https://www.nitibrush.com/articles/reported-outcomes/) page; they are outcomes of whole surgical protocols, and no study compared decontamination instruments.
- 19 of the ${FIG.publications} publications (12 of the 19 clinical studies) write "titanium brush" in the text and name HANS Korea in brackets or a footnote — see the instrument quotations on [Published studies](https://www.nitibrush.com/articles/).
- What distinguishes the instrument is the bristle alloy: nickel-titanium rather than commercially pure titanium ([raw material](https://www.nitibrush.com/product/raw-material/), [specifications](https://www.nitibrush.com/product/specifications/)). The [titanium brush](https://www.nitibrush.com/titanium-brush/) page explains the class; [which model for which defect](https://www.nitibrush.com/product/which-model/) gives the NANO / POCKET / POCKET SHORT / OMEGA criteria (1 thread exposed / 2–3 threads / 2–3 threads in the posterior region / more than 3 threads); [safety and limits](https://www.nitibrush.com/product/safety-and-limits/) states what the Instructions for Use say.
- Operating conditions printed in the Instructions for Use — implant motor, 20:1 reduction handpiece, 600–1,200 rpm at the brush, sterile saline irrigation — are on the [IFU parameters and evidence archive](https://www.nitibrush.com/clinical/evidence-archive/) page. For the chemical agents used alongside the NiTi Brush in the published protocols see [adjunctive chemical protocols](https://www.nitibrush.com/articles/chemical/).


## Entries in this reader that name the NiTi Brush (36)

Quoted conclusions as in the method chapters; the method of each paper may be a whole protocol in which the brush was one step.

- “Clinical, radiographic and patient-reported outcomes of surgical therapy of peri-implantitis were favorable at 12 months. The adjunctive use of electrolytic cleaning provided no added benefit over the use of a rotating titanium brush alone.” — [Regidor E et al. 2026](https://doi.org/10.1111/clr.70152), Clin Oral Implants Res (RCT); cited 4.
- “Non-abrasive waterjet cleaning is a superior method for the clinical treatment of peri-implantitis biofilms versus mechanical abrasive cleaning while maintaining titanium implant surface properties necessary for reintegration with peri-implant tissue.” — [Jazaeri MS et al. 2026](https://doi.org/10.1002/jper.11371), J Periodontol (in vitro); cited 2.
- “Combined surgical therapy for peri-implantitis, including implantoplasty and regeneration of the intrabony component, is effective in arresting disease progression and restoring peri-implant health. Extending implantoplasty to the contained intrabony compartment appears to provide additional clinical and radiographic benefits.” — [Monje A et al. 2026](https://doi.org/10.1111/cid.70144), Clin Implant Dent Relat Res (RCT).
- “The presented two-stage regenerative approach successfully restored peri-implant health and function over time while minimizing the patient's financial burden. The three re-entry procedures provided direct clinical evidence of bone regeneration and demonstrated the positive impact of effective maintenance therapy on marginal bone levels and their long-term stability.” — [Parma-Benfenati S et al. 2026](https://doi.org/10.1002/cap.10359), Clin Adv Periodontics (case report/series).
- “(no abstract)” — [Soliman OH et al. 2026](https://doi.org/10.23805/JO.2026.764), J Osseointegr (clinical study).
- “Surgical peri-implantitis outcome was associated with systemic antibiotic, surgeon, molar site, overdenture, baseline suppuration and PD.” — [Zhou W et al. 2026](https://doi.org/10.1111/jcpe.70115), J Clin Periodontol (clinical study).
- “Contact angle measurements indicated enhanced wettability in IB, PIB, and NiTiB groups (p < 0.05), while the LB group exhibited values comparable to the control (p > 0.05). Mechanical decontamination of implant surfaces utilising rotary brushes can alter implant surface properties.” — [Alabbad M et al. 2025](https://doi.org/10.1016/j.dental.2024.12.014), Dent Mater (in vitro); cited 6.
- “None of the investigated protocols compromised the cytocompatibility of the titanium dental implant surface. The best results were registered in the NITI group when the samples were stored in saline. Future studies should confirm the effectiveness of the proposed methods in removing bacterial biofilm from contaminated implant surfaces.” — [Brunello G et al. 2025](https://doi.org/10.1111/cid.13417), Clin Implant Dent Relat Res (in vitro); cited 4.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med (systematic review); cited 2.
- “At 3 years, the use of a bone substitute material in the surgical therapy of peri-implantitis did not result in a clear benefit over access flap surgery alone.” — [Alibegovic L et al. 2025](https://doi.org/10.1111/clr.14393), Clin Oral Implants Res (RCT).
- “The present results indicate that titanium micro-particles are commonly found in tissues surrounding dental implants and are not associated with the occurrence of peri-implantitis.” — [Dionigi C et al. 2025](https://doi.org/10.1038/s43856-025-00756-3), Commun Med (Lond) (clinical study).
- “The proportion of patients with improved clinical outcomes was similar between the 2 treatment groups, albeit surgical treatment yielded greater pocket reduction. No differences were found in immunological or microbial outcomes.” — [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683), J Periodontol (RCT).
- “Both tested surface decontamination methods are effective in resolving peri-implantitis, in gaining radiographic marginal bone levels, and in enhancing clinical peri-implant conditions in the surgical reconstructive therapy (NCT05615051).” — [Monje A et al. 2025](https://doi.org/10.1111/cid.70075), Clin Implant Dent Relat Res (RCT).
- “EM combined with mechanical instrumentation results in a safe and effective surface decontamination modality in the reconstructive therapy of peri-implantitis. This strategy resulted in a disease resolution rate of ~91%.” — [Monje A et al. 2025](https://doi.org/10.11607/prd.7151), Int J Periodontics Restorative Dent (clinical study).
- “Interestingly, the CERID surface mitigated the immune response by inducing an upregulation of anti-inflammatory cytokine IL-10 on activated PBMCs when a pro-inflammatory microenvironment was established. Our in vitro results pave the way to further investigations aiming to corroborate the potential of CERID implants as suitable biomaterials for dental implant applications.” — [Tagliaferri N et al. 2024](https://doi.org/10.3390/nano14050392), Nanomaterials (Basel) (in vitro); cited 11.
- “The EDS analysis confirmed Ti in PEEK US tips. It can be suggested that deterioration from the PEEK US tip and Ti brush, as observed under SEM, is an additional source of Ti release during Ti surface decontamination.” — [Kao A et al. 2024](https://doi.org/10.3390/dj12050123), Dent J (Basel) (in vitro); cited 3.
- “The reconstructive approach employed in these cases appears to be an effective method for managing early biological complications following dental implant installation. The successful restoration of healthy peri-implant tissues was achieved, indicating the potential efficacy of this treatment strategy.” — [Walaa Babgi et al. 2024](https://doi.org/10.54940/ms75920247), Journal of Umm Al-Qura University for Medical Sciences (clinical study); cited 0.
- “We found that mechanical damage led to decrease of stoichiometric TiO2 ratio in the passivation oxide film and further resulted in accelerated degradation under inflammatory anaerobic conditions. This method can be employed for the assessment of surface oxides to monitor implant safety.” — [Kotsakis GA et al. 2024](https://doi.org/10.1038/s41529-024-00514-1), Npj Mater Degrad (not classified).
- “No significant differences were observed in the different bone neoformation parameters between the groups that did not receive bone grafts (p > 0.05). In this experimental model, the presence of peri-implantitis microcosms was not a determining factor in the bone volume parameter, both in the groups that received regenerative treatment and in those that did not.” — [Panes C et al. 2024](https://doi.org/10.3390/bioengineering11040397), Bioengineering (Basel) (animal study).
- “Air-polishing and rotating TiB were more effective implant surface decontamination protocols than wiping with gauzes. Use of chemical agents did not improve cleaning efficacy.” — [Ichioka Y et al. 2023](https://doi.org/10.1111/clr.14136), Clin Oral Implants Res (in vitro); cited 21.
- “All treatment protocols were associated with short-term improvements in the clinical parameters investigated.” — [Schwarz F et al. 2023](https://doi.org/10.1111/clr.14057), Clin Oral Implants Res (clinical study); cited 6.
- “, although bacterial biofilms were removed from titanium surface after debridement, the surface topography changes could still induce immune imbalance and form an inflammatory immune microenvironment. However, this inflammatory immune microenvironment can be effectively reversed by 2-DG in vitro, thus creating an immune microenvironment conducive to osteogenesis, which might provide a new perspective for future …” — [Liu X et al. 2023](https://doi.org/10.3390/ijms241411431), Int J Mol Sci (in vitro); cited 3.
- “This case series demonstrated that implantoplasty during surgical treatment of peri-implantitis lesions resulted in favorable biological conditions to maintain functional implants with 96.7% of implants that did not show bone loss over time from one year to more than three years.” — [Arthur Brincat et al. 2023](https://doi.org/10.3390/app13127224), Applied Sciences (case report/series); cited 1.
- “Reconstructive therapy by means of a mixture of mineralized and demineralized allografts is effective in clinically resolving peri-implantitis and in gaining radiographic marginal bone level. The addition of a barrier membrane to reconstructive therapy of peri-implantitis does not seem to enhance the outcomes of contained bone defects (NCT05282667).” — [Monje A et al. 2023](https://doi.org/10.1002/JPER.22-0511), J Periodontol (RCT).
- “Baseline DA of peri-implantitis intrabony components predicts radiographic bone gain in reconstructive therapy (NCT05282667-this clinical trial was not registered prior to participant recruitment and randomization).” — [Monje A et al. 2023](https://doi.org/10.1111/cid.13244), Clin Implant Dent Relat Res (RCT).
- “This study failed to demonstrate the presence of added clinical or radiographic benefits of the use of a resorbable membrane to cover a bone substitute material within the reconstructive surgical therapy of peri-implantitis associated with intra-bony defects.” — [Regidor E et al. 2023](https://doi.org/10.1111/jcpe.13796), J Clin Periodontol (RCT).
- “(no abstract)” — [Regidor E et al. 2023](https://www.nitibrush.com/articles/), Perio Clín (review).
- “AP was the most effective decontamination procedure in reducing bacteria without depositing residual foreign material on Ti(r) discs. TiB and AP were superior methods in restoring cytocompatibility, although no method of mechanical decontamination resulted in pristine levels of cytocompatibility.” — [Ichioka Y et al. 2022](https://doi.org/10.1002/jbm.b.34978), J Biomed Mater Res B Appl Biomater (in vitro); cited 29.
- “Surgical therapy of peri-implantitis effectively improved the clinical and radiographic status at 12 months. While the use of a bone substitute material did not improve reductions of PPD and BOP, buccal REC was less pronounced in the test group. Patient satisfaction was high in both groups.” — [Derks J et al. 2022](https://doi.org/10.1111/clr.13972), Clin Oral Implants Res (RCT).
- “Implantoplasty as an adjunct to surgical therapy proved effective in terms of disease resolution and implant survival rate. Implant location, defect morphology as well as the buccal width of KM are indicators of therapeutic success.” — [Monje A et al. 2022](https://doi.org/10.1002/JPER.21-0103), J Periodontol (clinical study).
- “The peri-implant mucosa undergoes considerable volumetric changes after combined surgical therapy. However, tissue contraction appears to be influenced by the width of KM.” — [Galarraga-Vinueza ME et al. 2020](https://doi.org/10.1111/jcpe.13335), J Clin Periodontol (clinical study); cited 56.
- “(no abstract)” — [Hiroyasu K 2018](https://ir.tdc.ac.jp/irucaa/bitstream/10130/4541/1/10_33.pdf), J Jpn Soc Oral Exam (not classified).
- “The third and fifth groups also had significantly decreased bacterial adhesion on the SLA surfaces. The implant cleaning bur reduced the roughness of RBM and SLA titanium implants, and decreased the adhesion of bacteria on SLA surfaces, which may help prevent the recurrence of peri-implantitis.” — [Seul‐Kee Kim et al. 2016](https://doi.org/10.21851/obr.40.1.201603.9), Oral Biology Research (in vitro); cited 1.
- “(no abstract)” — [Kusek ER 2015](https://doi.org/10.4172/2161-1122.1000348), Dentistry (clinical study).
- “(no abstract)” — [Narendrakumar K 2015](https://etheses.bham.ac.uk/id/eprint/5677/), PhD thesis, University of Birmingham (not classified).
- “(no abstract)” — [Suzuki A et al. 2014](https://doi.org/10.11237/jsoi.27.370), J Jpn Soc Oral Implantol (not classified).


## What the company states about the published evidence as a whole

On the published evidence as a whole, HANS Korea states the following, in its own voice and apart from the method chapters: by the breadth of the published literature — number of publications, patients and implants reported, length of follow-up and the multicentre, multi-country spread of the clinical studies — the NiTi Brush is the rotary brush with the most extensive published clinical record identified in this index, and a clinician choosing a brush for the first time may reasonably start from that record. This is a statement about the accumulation of published evidence.

The figures behind this statement are in [chapter 3, published clinical evidence by named brush](https://www.nitibrush.com/articles/literature-index/titanium-brush/#by-brush).


## What the company does not claim

- No superiority or equivalence of the NiTi Brush over any other method or product in this reader.
- No transfer of results obtained with another manufacturer's titanium brush to the NiTi Brush, or the reverse.
- No clinical outcome of its own: every outcome figure on this website is a published figure of a whole protocol, with its source.

- Previous: [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- Next: [16. Glossary](https://www.nitibrush.com/articles/literature-index/glossary/)


---

# 16. Glossary

Plain definitions of the 38 terms used in the implant surface decontamination reader: peri-implantitis, biofilm, decontamination, implantoplasty, the study types, the outcome measures, the surface types, the laser types, the bibliographic identifiers.

URL: https://www.nitibrush.com/articles/literature-index/glossary/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

The terms of the reader, defined descriptively and without outcome claims.

**Peri-implantitis** — A plaque-associated inflammatory condition of the tissues around a dental implant with loss of supporting bone, in contrast to peri-implant mucositis, in which the soft tissue is inflamed without bone loss.

**Peri-implant mucositis** — Inflammation of the soft tissue around an implant without loss of supporting bone; considered the precursor of peri-implantitis.

**Biofilm** — The structured community of bacteria embedded in a matrix on the implant surface; its removal or inactivation is the aim of every method in this reader.

**Implant surface decontamination** — Removing or inactivating the biofilm and its products on the exposed part of the implant so that the surface becomes biologically acceptable again; the papers also write debridement (mechanical removal of deposits) and detoxification (chemical inactivation of bacterial products).

**Mechanical debridement** — Removal of deposits from the implant surface by an instrument — brush, curette, ultrasonic tip, air-polishing jet, bur.

**Chemical adjunct** — A solution, gel or paste applied to the implant surface in addition to mechanical debridement.

**Implantoplasty** — Grinding and polishing of the exposed implant threads to a smooth surface.

**Resective surgery** — Surgical treatment in which the pocket is eliminated by recontouring bone and soft tissue; the implant surface is left exposed to the oral environment, often after implantoplasty.

**Reconstructive (regenerative) surgery** — Surgical treatment in which the bone defect around the implant is filled with a bone substitute, with or without a membrane, after decontamination of the surface; the papers also write GBR (guided bone regeneration).

**Combined surgery** — Implantoplasty of the supracrestal part and reconstruction of the intrabony part of the same defect.

**Non-surgical therapy** — Treatment without raising a flap: instrumentation of the implant surface through the pocket, with or without adjuncts.

**Supportive peri-implant care** — The recall and maintenance programme after active treatment.

**Probing pocket depth (PPD)** — The distance from the mucosal margin to the bottom of the pocket measured with a periodontal probe, in millimetres.

**Bleeding on probing (BOP)** — Bleeding provoked by gentle probing of the pocket; recorded as present or absent per site.

**Suppuration** — Pus discharge from the pocket on probing or pressure.

**Marginal bone level** — The position of the bone crest around the implant measured on a radiograph, relative to a fixed reference on the implant.

**Disease resolution** — A composite outcome defined by each study, typically no further bone loss, no bleeding or suppuration, and pocket depths below a threshold.

**Surface roughness (Ra, Sa)** — Laboratory measures of the height variation of a surface: Ra is the arithmetic mean over a profile line, Sa over an area.

**SLA, RBM, TPS, HA surfaces** — Common implant surface types: sand-blasted and acid-etched (SLA), resorbable blast media (RBM), titanium plasma-sprayed (TPS) and hydroxyapatite-coated (HA); machined (turned) surfaces are the smooth comparison.

**SEM** — Scanning electron microscopy, used in the laboratory papers to image the surface before and after treatment.

**Titanium particle release** — Metal particles detached from the implant during instrumentation or implantoplasty, measured in several laboratory studies.

**Osseointegration / re-osseointegration** — Direct bone-to-implant contact; re-osseointegration is new bone contact on a previously contaminated surface, assessed histologically in animal studies.

**Titanium brush (generic term)** — Any rotary brush with titanium or titanium-alloy bristles used on the implant surface, from any manufacturer. Where a paper names a product or company, this reader shows the name as written; where it does not, the entry is listed as a titanium-brush study without attribution.

**NiTi Brush** — The specific instrument of HANS KOREA CO.,Ltd. (Paju, Republic of Korea): a rotary brush with nickel-titanium bristles for implant surface debridement, introduced in 2010, the first of the titanium-brush class. Papers identify it by writing "NiTi Brush" or "HANS Korea" — often only in brackets, a footnote or the Methods section while the text says "titanium brush"; see chapter 3.

**NiTi, nickel-titanium** — An alloy of nickel and titanium (nitinol) with a lower elastic modulus than commercially pure titanium; the bristle material of the NiTi Brush.

**Handpiece ratio, rpm** — The gear ratio of the handpiece that drives a rotary instrument (for example 20:1 reduction) and the resulting speed of the instrument in revolutions per minute.

**Er:YAG, Er,Cr:YSGG, Nd:YAG, diode, CO₂** — Laser types named after their active medium; each has a characteristic wavelength and tissue interaction.

**aPDT** — Antimicrobial photodynamic therapy: photosensitiser plus light.

**Electrolytic cleaning** — Decontamination by an electric current through an electrolyte in contact with the implant.

**Cold atmospheric plasma** — Ionised gas generated at near-body temperature and applied to a surface.

**Randomised clinical trial, systematic review, case series …** — See the study-type definitions in the introduction.

**Entry** — One publication in this reader. The count is written "N entries"; it is not the number of publications that name the NiTi Brush, which is a separate, smaller list on the Published studies page.

**Takeaway** — The conclusion sentence of the paper's own abstract, quoted without change; where the abstract is unstructured, its closing sentences.

**PubMed, PMID** — The US National Library of Medicine's bibliographic database and the identifier of a record in it.

**OpenAlex** — An open bibliographic database used here for citation counts and for publications not indexed in PubMed.

**DOI** — Digital Object Identifier; every link in this reader goes to the publisher's page through https://doi.org/.

**Open access** — A publication whose full text is freely readable; for those entries the Methods section was also read for product, company and agent names.

**Cited by** — The number of later works citing the publication according to OpenAlex at the time of the last refresh; shown for orientation, not as a quality grade.

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [15. A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/)
- Next: [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)
