16. Glossary

Chapter as text: glossary.md · whole reader: reader.md · data: JSON / CSV

The terms of the reader, defined descriptively and without outcome claims.

Peri-implantitis
A plaque-associated inflammatory condition of the tissues around a dental implant with loss of supporting bone, in contrast to peri-implant mucositis, in which the soft tissue is inflamed without bone loss.
Peri-implant mucositis
Inflammation of the soft tissue around an implant without loss of supporting bone; considered the precursor of peri-implantitis.
Biofilm
The structured community of bacteria embedded in a matrix on the implant surface; its removal or inactivation is the aim of every method in this reader.
Implant surface decontamination
Removing or inactivating the biofilm and its products on the exposed part of the implant so that the surface becomes biologically acceptable again; the papers also write debridement (mechanical removal of deposits) and detoxification (chemical inactivation of bacterial products).
Mechanical debridement
Removal of deposits from the implant surface by an instrument — brush, curette, ultrasonic tip, air-polishing jet, bur.
Chemical adjunct
A solution, gel or paste applied to the implant surface in addition to mechanical debridement.
Implantoplasty
Grinding and polishing of the exposed implant threads to a smooth surface.
Resective surgery
Surgical treatment in which the pocket is eliminated by recontouring bone and soft tissue; the implant surface is left exposed to the oral environment, often after implantoplasty.
Reconstructive (regenerative) surgery
Surgical treatment in which the bone defect around the implant is filled with a bone substitute, with or without a membrane, after decontamination of the surface; the papers also write GBR (guided bone regeneration).
Combined surgery
Implantoplasty of the supracrestal part and reconstruction of the intrabony part of the same defect.
Non-surgical therapy
Treatment without raising a flap: instrumentation of the implant surface through the pocket, with or without adjuncts.
Supportive peri-implant care
The recall and maintenance programme after active treatment.
Probing pocket depth (PPD)
The distance from the mucosal margin to the bottom of the pocket measured with a periodontal probe, in millimetres.
Bleeding on probing (BOP)
Bleeding provoked by gentle probing of the pocket; recorded as present or absent per site.
Suppuration
Pus discharge from the pocket on probing or pressure.
Marginal bone level
The position of the bone crest around the implant measured on a radiograph, relative to a fixed reference on the implant.
Disease resolution
A composite outcome defined by each study, typically no further bone loss, no bleeding or suppuration, and pocket depths below a threshold.
Surface roughness (Ra, Sa)
Laboratory measures of the height variation of a surface: Ra is the arithmetic mean over a profile line, Sa over an area.
SLA, RBM, TPS, HA surfaces
Common implant surface types: sand-blasted and acid-etched (SLA), resorbable blast media (RBM), titanium plasma-sprayed (TPS) and hydroxyapatite-coated (HA); machined (turned) surfaces are the smooth comparison.
SEM
Scanning electron microscopy, used in the laboratory papers to image the surface before and after treatment.
Titanium particle release
Metal particles detached from the implant during instrumentation or implantoplasty, measured in several laboratory studies.
Osseointegration / re-osseointegration
Direct bone-to-implant contact; re-osseointegration is new bone contact on a previously contaminated surface, assessed histologically in animal studies.
Titanium brush (generic term)
Any rotary brush with titanium or titanium-alloy bristles used on the implant surface, from any manufacturer. Where a paper names a product or company, this reader shows the name as written; where it does not, the entry is listed as a titanium-brush study without attribution.
NiTi Brush
The specific instrument of HANS KOREA CO.,Ltd. (Paju, Republic of Korea): a rotary brush with nickel-titanium bristles for implant surface debridement, introduced in 2010, the first of the titanium-brush class. Papers identify it by writing "NiTi Brush" or "HANS Korea" — often only in brackets, a footnote or the Methods section while the text says "titanium brush"; see chapter 3.
NiTi, nickel-titanium
An alloy of nickel and titanium (nitinol) with a lower elastic modulus than commercially pure titanium; the bristle material of the NiTi Brush.
Handpiece ratio, rpm
The gear ratio of the handpiece that drives a rotary instrument (for example 20:1 reduction) and the resulting speed of the instrument in revolutions per minute.
Er:YAG, Er,Cr:YSGG, Nd:YAG, diode, CO₂
Laser types named after their active medium; each has a characteristic wavelength and tissue interaction.
aPDT
Antimicrobial photodynamic therapy: photosensitiser plus light.
Electrolytic cleaning
Decontamination by an electric current through an electrolyte in contact with the implant.
Cold atmospheric plasma
Ionised gas generated at near-body temperature and applied to a surface.
Randomised clinical trial, systematic review, case series …
See the study-type definitions in the introduction.
Entry
One publication in this reader. The count is written "N entries"; it is not the number of publications that name the NiTi Brush, which is a separate, smaller list on the Published studies page.
Takeaway
The conclusion sentence of the paper's own abstract, quoted without change; where the abstract is unstructured, its closing sentences.
PubMed, PMID
The US National Library of Medicine's bibliographic database and the identifier of a record in it.
OpenAlex
An open bibliographic database used here for citation counts and for publications not indexed in PubMed.
DOI
Digital Object Identifier; every link in this reader goes to the publisher's page through https://doi.org/.
Open access
A publication whose full text is freely readable; for those entries the Methods section was also read for product, company and agent names.
Cited by
The number of later works citing the publication according to OpenAlex at the time of the last refresh; shown for orientation, not as a quality grade.

This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to chapter 15. Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).