15. A note from the manufacturer — where the NiTi Brush stands in this literature

Chapter as text: manufacturer.md · whole reader: reader.md · data: JSON / CSV

This chapter is written by the company that compiles the reader. Everything in it concerns one instrument, the NiTi Brush, and is kept apart from the method chapters so that a reader can take the literature without it and the company's statements with their source.

Who writes this reader and why

HANS KOREA CO.,Ltd. (Paju, Republic of Korea) developed the NiTi Brush, the first brush for implant-surface debridement with nickel-titanium bristles, in 2010, and the "titanium brush" category grew around it. The company compiles this reader because the literature of its own field was hard to find in one place; the method chapters are generated from the public records and report every instrument, including those of other manufacturers, as its authors did.

What the company states about the NiTi Brush

Each statement is sourced on the linked page, and none ranks the instrument against the other methods in this reader.

  • 36 entries in this reader name the NiTi Brush or HANS Korea in the title, abstract or open-access full text (listed below). Separately, ${FIG.publications} publications identify the NiTi Brush in the text or a footnote (${FIG.scie} in SCI(E)-indexed journals, ${FIG.rct} randomised-trial publications); publications that say "titanium brush" without naming a manufacturer are not counted among them.
  • Across those publications the instrument is named in clinical studies of ${FIG.patients} patients and ${FIG.implants} implants, with follow-up up to 10 years; in that sense its clinical use is documented in the peer-reviewed record. Study-by-study outcome figures, as printed in the papers, are on the reported outcomes page; they are outcomes of whole surgical protocols, and no study compared decontamination instruments.
  • 19 of the ${FIG.publications} publications (12 of the 19 clinical studies) write "titanium brush" in the text and name HANS Korea in brackets or a footnote — see the instrument quotations on Published studies.
  • What distinguishes the instrument is the bristle alloy: nickel-titanium rather than commercially pure titanium (raw material, specifications). The titanium brush page explains the class; which model for which defect gives the NANO / POCKET / POCKET SHORT / OMEGA criteria (1 thread exposed / 2–3 threads / 2–3 threads in the posterior region / more than 3 threads); safety and limits states what the Instructions for Use say.
  • Operating conditions printed in the Instructions for Use — implant motor, 20:1 reduction handpiece, 600–1,200 rpm at the brush, sterile saline irrigation — are on the IFU parameters and evidence archive page. For the chemical agents used alongside the NiTi Brush in the published protocols see adjunctive chemical protocols.

Entries in this reader that name the NiTi Brush (36)

Quoted conclusions as in the method chapters; the method of each paper may be a whole protocol in which the brush was one step.

  • Clinical, radiographic and patient-reported outcomes of surgical therapy of peri-implantitis were favorable at 12 months. The adjunctive use of electrolytic cleaning provided no added benefit over the use of a rotating titanium brush alone. — Regidor E et al. 2026, Clin Oral Implants Res (RCT); cited 4.
  • Non-abrasive waterjet cleaning is a superior method for the clinical treatment of peri-implantitis biofilms versus mechanical abrasive cleaning while maintaining titanium implant surface properties necessary for reintegration with peri-implant tissue. — Jazaeri MS et al. 2026, J Periodontol (in vitro); cited 2.
  • Combined surgical therapy for peri-implantitis, including implantoplasty and regeneration of the intrabony component, is effective in arresting disease progression and restoring peri-implant health. Extending implantoplasty to the contained intrabony compartment appears to provide additional clinical and radiographic benefits. — Monje A et al. 2026, Clin Implant Dent Relat Res (RCT).
  • The presented two-stage regenerative approach successfully restored peri-implant health and function over time while minimizing the patient's financial burden. The three re-entry procedures provided direct clinical evidence of bone regeneration and demonstrated the positive impact of effective maintenance therapy on marginal bone levels and their long-term stability. — Parma-Benfenati S et al. 2026, Clin Adv Periodontics (case report/series).
  • (no abstract) — Soliman OH et al. 2026, J Osseointegr (clinical study).
  • Surgical peri-implantitis outcome was associated with systemic antibiotic, surgeon, molar site, overdenture, baseline suppuration and PD. — Zhou W et al. 2026, J Clin Periodontol (clinical study).
  • Contact angle measurements indicated enhanced wettability in IB, PIB, and NiTiB groups (p < 0.05), while the LB group exhibited values comparable to the control (p > 0.05). Mechanical decontamination of implant surfaces utilising rotary brushes can alter implant surface properties. — Alabbad M et al. 2025, Dent Mater (in vitro); cited 6.
  • None of the investigated protocols compromised the cytocompatibility of the titanium dental implant surface. The best results were registered in the NITI group when the samples were stored in saline. Future studies should confirm the effectiveness of the proposed methods in removing bacterial biofilm from contaminated implant surfaces. — Brunello G et al. 2025, Clin Implant Dent Relat Res (in vitro); cited 4.
  • Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols. — Pappolla Sessa C et al. 2025, J Clin Med (systematic review); cited 2.
  • At 3 years, the use of a bone substitute material in the surgical therapy of peri-implantitis did not result in a clear benefit over access flap surgery alone. — Alibegovic L et al. 2025, Clin Oral Implants Res (RCT).
  • The present results indicate that titanium micro-particles are commonly found in tissues surrounding dental implants and are not associated with the occurrence of peri-implantitis. — Dionigi C et al. 2025, Commun Med (Lond) (clinical study).
  • The proportion of patients with improved clinical outcomes was similar between the 2 treatment groups, albeit surgical treatment yielded greater pocket reduction. No differences were found in immunological or microbial outcomes. — Malmqvist S et al. 2025, J Periodontol (RCT).
  • Both tested surface decontamination methods are effective in resolving peri-implantitis, in gaining radiographic marginal bone levels, and in enhancing clinical peri-implant conditions in the surgical reconstructive therapy (NCT05615051). — Monje A et al. 2025, Clin Implant Dent Relat Res (RCT).
  • EM combined with mechanical instrumentation results in a safe and effective surface decontamination modality in the reconstructive therapy of peri-implantitis. This strategy resulted in a disease resolution rate of ~91%. — Monje A et al. 2025, Int J Periodontics Restorative Dent (clinical study).
  • Interestingly, the CERID surface mitigated the immune response by inducing an upregulation of anti-inflammatory cytokine IL-10 on activated PBMCs when a pro-inflammatory microenvironment was established. Our in vitro results pave the way to further investigations aiming to corroborate the potential of CERID implants as suitable biomaterials for dental implant applications. — Tagliaferri N et al. 2024, Nanomaterials (Basel) (in vitro); cited 11.
  • The EDS analysis confirmed Ti in PEEK US tips. It can be suggested that deterioration from the PEEK US tip and Ti brush, as observed under SEM, is an additional source of Ti release during Ti surface decontamination. — Kao A et al. 2024, Dent J (Basel) (in vitro); cited 3.
  • The reconstructive approach employed in these cases appears to be an effective method for managing early biological complications following dental implant installation. The successful restoration of healthy peri-implant tissues was achieved, indicating the potential efficacy of this treatment strategy. — Walaa Babgi et al. 2024, Journal of Umm Al-Qura University for Medical Sciences (clinical study); cited 0.
  • We found that mechanical damage led to decrease of stoichiometric TiO2 ratio in the passivation oxide film and further resulted in accelerated degradation under inflammatory anaerobic conditions. This method can be employed for the assessment of surface oxides to monitor implant safety. — Kotsakis GA et al. 2024, Npj Mater Degrad (not classified).
  • No significant differences were observed in the different bone neoformation parameters between the groups that did not receive bone grafts (p > 0.05). In this experimental model, the presence of peri-implantitis microcosms was not a determining factor in the bone volume parameter, both in the groups that received regenerative treatment and in those that did not. — Panes C et al. 2024, Bioengineering (Basel) (animal study).
  • Air-polishing and rotating TiB were more effective implant surface decontamination protocols than wiping with gauzes. Use of chemical agents did not improve cleaning efficacy. — Ichioka Y et al. 2023, Clin Oral Implants Res (in vitro); cited 21.
  • All treatment protocols were associated with short-term improvements in the clinical parameters investigated. — Schwarz F et al. 2023, Clin Oral Implants Res (clinical study); cited 6.
  • , although bacterial biofilms were removed from titanium surface after debridement, the surface topography changes could still induce immune imbalance and form an inflammatory immune microenvironment. However, this inflammatory immune microenvironment can be effectively reversed by 2-DG in vitro, thus creating an immune microenvironment conducive to osteogenesis, which might provide a new perspective for future … — Liu X et al. 2023, Int J Mol Sci (in vitro); cited 3.
  • This case series demonstrated that implantoplasty during surgical treatment of peri-implantitis lesions resulted in favorable biological conditions to maintain functional implants with 96.7% of implants that did not show bone loss over time from one year to more than three years. — Arthur Brincat et al. 2023, Applied Sciences (case report/series); cited 1.
  • Reconstructive therapy by means of a mixture of mineralized and demineralized allografts is effective in clinically resolving peri-implantitis and in gaining radiographic marginal bone level. The addition of a barrier membrane to reconstructive therapy of peri-implantitis does not seem to enhance the outcomes of contained bone defects (NCT05282667). — Monje A et al. 2023, J Periodontol (RCT).
  • Baseline DA of peri-implantitis intrabony components predicts radiographic bone gain in reconstructive therapy (NCT05282667-this clinical trial was not registered prior to participant recruitment and randomization). — Monje A et al. 2023, Clin Implant Dent Relat Res (RCT).
  • This study failed to demonstrate the presence of added clinical or radiographic benefits of the use of a resorbable membrane to cover a bone substitute material within the reconstructive surgical therapy of peri-implantitis associated with intra-bony defects. — Regidor E et al. 2023, J Clin Periodontol (RCT).
  • (no abstract) — Regidor E et al. 2023, Perio Clín (review).
  • AP was the most effective decontamination procedure in reducing bacteria without depositing residual foreign material on Ti(r) discs. TiB and AP were superior methods in restoring cytocompatibility, although no method of mechanical decontamination resulted in pristine levels of cytocompatibility. — Ichioka Y et al. 2022, J Biomed Mater Res B Appl Biomater (in vitro); cited 29.
  • Surgical therapy of peri-implantitis effectively improved the clinical and radiographic status at 12 months. While the use of a bone substitute material did not improve reductions of PPD and BOP, buccal REC was less pronounced in the test group. Patient satisfaction was high in both groups. — Derks J et al. 2022, Clin Oral Implants Res (RCT).
  • Implantoplasty as an adjunct to surgical therapy proved effective in terms of disease resolution and implant survival rate. Implant location, defect morphology as well as the buccal width of KM are indicators of therapeutic success. — Monje A et al. 2022, J Periodontol (clinical study).
  • The peri-implant mucosa undergoes considerable volumetric changes after combined surgical therapy. However, tissue contraction appears to be influenced by the width of KM. — Galarraga-Vinueza ME et al. 2020, J Clin Periodontol (clinical study); cited 56.
  • (no abstract) — Hiroyasu K 2018, J Jpn Soc Oral Exam (not classified).
  • The third and fifth groups also had significantly decreased bacterial adhesion on the SLA surfaces. The implant cleaning bur reduced the roughness of RBM and SLA titanium implants, and decreased the adhesion of bacteria on SLA surfaces, which may help prevent the recurrence of peri-implantitis. — Seul‐Kee Kim et al. 2016, Oral Biology Research (in vitro); cited 1.
  • (no abstract) — Kusek ER 2015, Dentistry (clinical study).
  • (no abstract) — Narendrakumar K 2015, PhD thesis, University of Birmingham (not classified).
  • (no abstract) — Suzuki A et al. 2014, J Jpn Soc Oral Implantol (not classified).

What the company states about the published evidence as a whole

On the published evidence as a whole, HANS Korea states the following, in its own voice and apart from the method chapters: by the breadth of the published literature — number of publications, patients and implants reported, length of follow-up and the multicentre, multi-country spread of the clinical studies — the NiTi Brush is the rotary brush with the most extensive published clinical record identified in this index, and a clinician choosing a brush for the first time may reasonably start from that record. This is a statement about the accumulation of published evidence.

The figures behind this statement are in chapter 3, published clinical evidence by named brush.

What the company does not claim

  • No superiority or equivalence of the NiTi Brush over any other method or product in this reader.
  • No transfer of results obtained with another manufacturer's titanium brush to the NiTi Brush, or the reverse.
  • No clinical outcome of its own: every outcome figure on this website is a published figure of a whole protocol, with its source.