Chapter as text: implantoplasty.md · whole reader: reader.md · data: JSON / CSV
What does the literature report about implantoplasty (removing the implant threads and roughness)?
Key facts — Implantoplasty
- Entries in this chapter
- 154 of 819 (2003–2026): RCT 11 · clinical study 22 · case report/series 19 · systematic review 23 · consensus 1 · review 13 · in vitro 43 · animal study 7 · not classified 15
- Most cited
- Smeets R et al. 2014 (590); Frank Schwarz et al. 2011 (294); Prathapachandran J et al. 2012 (285)
- Products named by the authors
- Perio-Flow (3), Air-Flow (3), Ti-Brush (2), i-Brush (2), TiBrush (1), Cavitron (1), Vector (1)
- Manufacturers named by the authors
- Straumann (7), Komet (6), Geistlich (5), KaVo (5), EMS (4), Hu-Friedy (3), Nobel Biocare (2), Zimmer (2), Dentsply (2), Neobiotech (1)
- Chemical agents used alongside
- chlorhexidine (19), saline (19), antibiotics (systemic) (12), hydrogen peroxide (12), citric acid (11), amoxicillin (8), EDTA (3), sterile water (3)
- Often studied together with
- Chemical and antiseptic agents (32), Lasers (30), Air-polishing and air-abrasive devices (25), Titanium and nickel-titanium brushes (24)
- Entries naming the NiTi Brush
- 7 — see chapter 15
What it is
The exposed, supracrestal part of the implant is ground with rotary diamond or carbide burs and then polished with finer burs, stones or silicone polishers, so that the threads and the rough surface are removed and a smooth, cleanable surface remains. It changes the implant itself, which is why heat generation, titanium particle release and the loss of implant strength are recurring themes of the laboratory literature.
Mechanism and use, as the papers describe it
The publications in this chapter describe implantoplasty as the mechanical modification of the implant itself, with removal of the threads and smoothing of the surface, proposed as part of surgical peri-implantitis treatment.1 Contaminated titanium layers are ground away with rotary instruments so that the remaining surface retains less plaque, at the cost of a thinner implant wall.2 Laboratory protocols describe diamond or tungsten carbide burs of decreasing grit followed by finer diamonds, an Arkansas stone or silicone polishers, and sonic tips have been tested as an alternative to burs.3,4,5
In the trials of Schwarz and colleagues, implantoplasty was performed at the buccally and supracrestally exposed implant parts after access flap surgery and granulation tissue removal, while the intrabony surface was decontaminated by other means and augmented.6,7 Monje et al. compared implantoplasty limited to the supracrestal component with extension into a contained intrabony component, and Rosen described implantoplasty above and below the bone crest.8,9 In resective protocols the procedure is combined with an apically positioned flap and osteoplasty, and in combined protocols with regenerative treatment of the intrabony component.10,11 One clinical study applied 0.05% chlorhexidine gluconate and 3% hydrogen peroxide before debridement with tungsten carbide instruments, and laboratory studies applied citric acid, EDTA, hydrogen peroxide or saline to the machined surface afterwards to repassivate the titanium.12,13
Reported operating conditions
Ramel et al. tested six sequences on sandblasted and acid-etched implants: diamonds of 106, 40 and 15 µm grit followed by Brownie and Greenie silicone polishers or by an Arkansas stone, diamonds of 106, 40 and 4 µm, and complete sequences of 106, 40, 15, 8 and 4 µm, the last two each with or without a Greenie polisher.3 Treatment time ranged from 13 ± 2 min for the Arkansas stone sequence to 21 min for the longest sequences.3 Yildiz et al. used tungsten carbide sequences from two manufacturers (Komet Dental; Hager & Meisinger GmbH) and a diamond sequence of 125, 40 and 15 µm grit, with or without a Brownie polisher.14 Costa-Berenguer et al. reported a mean time of 10 min 48 s with high-speed burs and silicone polishers, and Park et al. recorded 5 min 27 s for implantoplasty against 3 min 1 s for rotating titanium brushes.15,16
Sharon et al. applied diamond, premium-line diamond, carbide and smooth burs on a high-speed handpiece with water-spray cooling for 60 s and measured removal of 59.24, 29.39, 11.35 and 0.19 mg of titanium respectively.17 Machining depth has been varied between 0.2, 0.4 and 0.6 mm of wall reduction, 0.4 mm corresponding to the thread height of the tested system.18,19 Implants treated in a phantom head were rougher and took longer than those treated on a table top, and residual threads and silicone debris were more frequent at posterior mandibular sites with adjacent teeth and a crown in place.20,21
Effects on the implant surface reported in laboratory studies
Mean Ra after the six sequences of Ramel et al. ranged from 0.32 ± 0.14 µm to 0.98 ± 0.30 µm, against 1.94 ± 0.47 µm for the untreated surface.3 Costa-Berenguer et al. measured Sa of 0.1 ± 0.02 µm after polishing against 0.75 ± 0.08 µm originally, and Camps-Font et al. reported Sa falling from 1.76 to 0.49 µm.15,22 Yildiz et al. found that tungsten carbide burs produced a roughness similar to or lower than that of turned surfaces even without polishing, whereas the diamond sequence required additional polishing.14 Toma et al. observed that implantoplasty changed the morphology, elemental composition and wettability of titanium discs, and other studies found residual titanium shavings, silicone debris, carbon and aluminium from polishers and tips.23,5,15 In situ, implantoplasty-treated surfaces accumulated less biofilm than turned or modified surfaces.24,25
Implantoplasty releases micro- and nanoparticles; Wu et al. found most particles below 100 nm, with numbers differing between implant systems.26 Toledano-Serrabona et al. characterised Ti6Al4V debris of 6–1850 µm with vanadium ion release and loss of cytocompatibility on osteoblasts and fibroblasts, and Barrak et al. reported reduced fibroblast viability from grade 5 alloy particles.27,28 Particles induced pro-inflammatory macrophage responses in vitro, and in rats debris placed in a mandibular defect produced a foreign body reaction and raised titanium ion concentrations in several organs.29,30,31 Two systematic reviews concluded that particles of 100 nm to 54 µm are detectable in peri-implant tissues without a consistent clinical association with peri-implantitis.32,33
Temperature rose by about 1.5 °C under water-spray cooling, and a systematic review states that implantoplasty does not increase temperature provided proper cooling is used.17,1 Chan et al. found the bending strength of 3.75 mm implants reduced from 613.9 to 511.4 N while 4.7 mm implants were unaffected, and Costa-Berenguer et al. found no significant difference for 4.1 mm external-connection implants (896 versus 880 N).34,15 Bertl et al. and Stavropoulos et al. reported significantly reduced failure strength, with narrow tissue-level implants and advanced bone loss most affected.35,36 Fatigue limits fell from about 351 N to 185–301 N depending on machining depth, and fatigue life decreased by 30% in another study.18,37 A 2025 meta-analysis estimated a fracture-resistance difference of −232 MPa with high heterogeneity, and a 2025 systematic review found the external hexagon connection most affected and the conical connection least.38,39 Corrosion current density increased after implantoplasty with pitting at the junction between machined and rough areas, and bacterial contamination further reduced fatigue and corrosion resistance.22,40,41
Position in treatment protocols
Non-augmentative therapy including implantoplasty is described for primarily horizontal bone loss or wide defects with limited regenerative potential in aesthetically non-demanding areas, and in combined protocols for the supracrestal and buccal component while the intrabony component is augmented.42,43,44 A 2021 meta-analysis reported a weighted mean difference of −1.11 mm in probing depth favouring adjunctive implantoplasty, and a network meta-analysis reported additional probing depth improvement over hand curettes at 6 and 12 months.45,46 Baima et al. reported favourable results for titanium brushes and implantoplasty as single methods while concluding that no method showed clear evidence of superiority.47
Cruz et al. found no added benefit over mechanical debridement alone at 24 months, Ravidà et al. found survival primarily influenced by bone loss at treatment rather than by implantoplasty, and Park et al. demonstrated non-inferiority of rotating titanium brushes.48,49,16 The 2021 EAO consensus stated that implantoplasty had no influence on mucosal recession, whereas Monje et al. and Bolun et al. observed more recession where implantoplasty was more extensive or replaced titanium brushes.50,8,12 Schwarz et al. found 4- and 7-year outcomes of combined therapy unaffected by whether the remaining surface was treated with an Er:YAG laser or with plastic curettes, cotton pellets and sterile saline.51,7
Limitations and open questions as stated by the authors
Stavropoulos et al. noted no fracture among 217–291 implants followed for 3–126 months but called the evidence limited.1 Goh et al. found no clear evidence on fracture resistance because methodological differences prevented comparison between in vitro studies.52 The certainty of evidence on particle effects was rated low, and Padullés-Roig et al. pointed to the absence of agreed protocols for machining depth.33,18 Valeriani et al. concluded that no universally safe tool for preserving surface integrity could be identified, and the AAP/AO review listed implantoplasty among methods inducing significant surface alteration and thread flattening.53,54 Cruz et al. and Khayat et al. called for larger randomised trials, and a 2026 review advised judicious use because of particle release.48,55,56
Sources cited in this description (56)
- Stavropoulos A et al. (2019). Mechanical and biological complications after implantoplasty-A systematic review. Clin Oral Implants Res. doi:10.1111/clr.13499 · systematic review
- Tsampli A et al. (2024). In vitro pilot study comparing a novel implantoplasty sonic instrumentation protocol with a conventional protocol using burs. Clin Oral Implants Res. doi:10.1111/clr.14231 · in vitro
- Ramel CF et al. (2016). Surface roughness of dental implants and treatment time using six different implantoplasty procedures. Clin Oral Implants Res. doi:10.1111/clr.12682 · in vitro
- Beheshti Maal M et al. (2020). Experimental implantoplasty outcomes correlate with fibroblast growth in vitro. BMC Oral Health. doi:10.1186/s12903-020-1012-1 · in vitro
- Sivolella S et al. (2021). Implantoplasty: Carbide burs vs diamond sonic tips. An in vitro study. Clin Oral Implants Res. doi:10.1111/clr.13702 · in vitro
- Frank Schwarz et al. (2011). Impact of the method of surface debridement and decontamination on the clinical outcome following combined surgical therapy of peri-implantitis: a randomized controlled clinical study Journal Of Clinical Periodontology. doi:10.1111/j.1600-051x.2010.01690.x · RCT
- Schwarz F et al. (2017). Combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination: a 7-year follow-up observation. J Clin Periodontol. doi:10.1111/jcpe.12648 · RCT
- Monje A et al. (2026). Extent of Implantoplasty in the Combined Surgical Therapy of Peri-Implantitis: A Quasi-Randomized Clinical Trial. Clin Implant Dent Relat Res. doi:10.1111/cid.70144 · RCT
- Rosen PS et al. (2023). Subcrestal Implantoplasty for Treating Peri-implantitis With Regenerative Care-How Deep Should Treatment Go? Compend Contin Educ Dent. PMID 37708040 · not classified
- Englezos E et al. (2018). Resective Treatment of Peri-implantitis: Clinical and Radiographic Outcomes After 2 Years. Int J Periodontics Restorative Dent. doi:10.11607/prd.3386 · clinical study
- Monje A et al. (2022). Resolution of peri-implantitis by means of implantoplasty as adjunct to surgical therapy: A retrospective study. J Periodontol. doi:10.1002/JPER.21-0103 · clinical study
- Radu Bolun et al. (2024). Mechanical modification of the implant surface as an adjunctive measure during surgical treatment of peri-implantitis Journal of Stomatological Medicine. doi:10.53530/1857-1328.24.1.09 · clinical study
- Millas L et al. (2026). Repassivation of Titanium Surface with Different Disinfectants After Implantoplasty: Effects on Corrosion, Ion Release, Cytotoxicity and Bacterial Behaviour-An In Vitro Study. Dent J (Basel). doi:10.3390/dj14090587 · in vitro
- Hulya Yildiz et al. (2022). Titanium implant surface roughness after different implantoplasty protocols: A laboratory study Clinical and Experimental Dental Research. doi:10.1002/cre2.659 · in vitro
- Costa-Berenguer X et al. (2018). Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants. Clin Oral Implants Res. doi:10.1111/clr.13037 · in vitro
- Park SH et al. (2026). Implantoplasty vs. Rotating Titanium Brushes in the Surgical Treatment of Peri-Implantitis: A 1-Year Randomised Controlled Clinical Trial. J Clin Periodontol. doi:10.1111/jcpe.70056 · RCT
- Sharon E et al. (2013). Efficiency and thermal changes during implantoplasty in relation to bur type. Clin Implant Dent Relat Res. doi:10.1111/j.1708-8208.2011.00366.x · not classified
- Padullés-Roig E et al. (2026). Mechanical Fatigue of Titanium Dental Implants After Implantoplasty: An In Vitro Study Combined with Finite Element Simulations. J Funct Biomater. doi:10.3390/jfb17050221 · in vitro
- Padullés-Roig E et al. (2026). Fatigue Behavior of Dental Implants Affected by Peri-Implantitis-Related Bone Loss: Influence of Implantoplasty Evaluated Through In Vitro Testing and Finite Element Modeling. Dent J (Basel). doi:10.3390/dj14060329 · in vitro
- Eamonn Donohoe et al. (2026). The Impact of Operator Access on Implant Surface Roughness Following Implantoplasty Procedures: A Laboratory Study Clinical and Experimental Dental Research. doi:10.1002/cre2.70336 · in vitro
- Burgueño-Barris G et al. (2023). Factors Affecting Implant Surface Roughness and Platform Alterations After Implantoplasty: An In Vitro Study Simulating Different Clinical Scenarios. Int J Oral Maxillofac Implants. doi:10.11607/jomi.10074 · in vitro
- Octavi Camps‐Font et al. (2023). Effect of Implantoplasty on Roughness, Fatigue and Corrosion Behavior of Narrow Diameter Dental Implants Journal of Functional Biomaterials. doi:10.3390/jfb14020061 · in vitro
- Toma S et al. (2016). In vitro evaluation of peri-implantitis treatment modalities on Saos-2osteoblasts. Clin Oral Implants Res. doi:10.1111/clr.12686 · in vitro
- Bertl K et al. (2024). Reduced Biofilm Accumulation on Implants Treated With Implantoplasty-An In Situ Trial With a Within-Subject Comparison. Clin Exp Dent Res. doi:10.1002/cre2.70043 · RCT
- Azzola F et al. (2020). Biofilm Formation on Dental Implant Surface Treated by Implantoplasty: An In Situ Study. Dent J (Basel). doi:10.3390/dj8020040 · in vitro
- Wu X et al. (2022). Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. Materials (Basel). doi:10.3390/ma15020602 · in vitro
- Toledano-Serrabona J et al. (2021). Physicochemical and Biological Characterization of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part I. Materials (Basel). doi:10.3390/ma14216507 · in vitro
- Barrak FN et al. (2020). Particle release from implantoplasty of dental implants and impact on cells. Int J Implant Dent. doi:10.1186/s40729-020-00247-1 · in vitro
- Gil J et al. (2026). Immunological and tissue reactions to titanium particles generated by the mechanical decontamination of dental implants: In vitro and in vivo study. Med Oral Patol Oral Cir Bucal. doi:10.4317/medoral.27171 · in vitro
- Toledano-Serrabona J et al. (2023). Ion release and local effects of titanium metal particles from dental implants: An experimental study in rats. J Periodontol. doi:10.1002/JPER.22-0091 · animal study
- Diogo Pompéu de Moraes et al. (2023). Tracking soluble and nanoparticulated titanium released in vivo from metal dental implant debris using (single-particle)-ICP-MS Journal of Trace Elements in Medicine and Biology. doi:10.1016/j.jtemb.2023.127143 · animal study
- Suárez-López Del Amo F et al. (2018). Dental implants-associated release of titanium particles: A systematic review. Clin Oral Implants Res. doi:10.1111/clr.13372 · systematic review
- Rodríguez Alvarez MB et al. (2025). Release of Titanium Particles After Implantoplasty in the Treatment of Peri-Implantitis: Local and Systemic Implications-An Integrative Systematic Review. J Clin Med. doi:10.3390/jcm14248661 · systematic review
- Chan HL et al. (2013). Impact of implantoplasty on strength of the implant-abutment complex. Int J Oral Maxillofac Implants. doi:10.11607/jomi.3227 · in vitro
- Bertl K et al. (2021). Does implantoplasty affect the failure strength of narrow and regular diameter implants? A laboratory study. Clin Oral Investig. doi:10.1007/s00784-020-03534-8 · in vitro
- Stavropoulos A et al. (2023). Implantoplasty and the risk of fracture of narrow implants with advanced bone loss: A laboratory study. Clin Oral Implants Res. doi:10.1111/clr.14132 · in vitro
- Fonseca D et al. (2024). The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants. Materials (Basel). doi:10.3390/ma17122944 · in vitro
- Giovanni Pissu et al. (2025). Effect of the implantoplasty techniques on the fracture resistance of dental implants. Systematic review and meta-analysis Frontiers in Dental Medicine. doi:10.3389/fdmed.2025.1568465 · systematic review
- Manuel Alejandro León Velastegui et al. (2025). Influence of Different Implantoplasty Designs on the Fatigue Resistance of Dental Implants: A Systematic Review Journal of Clinical Medicine. doi:10.3390/jcm14176103 · systematic review
- Pablo Lozano et al. (2022). Corrosion Behavior of Titanium Dental Implants with Implantoplasty Materials. doi:10.3390/ma15041563 · not classified
- Vegas-Bustamante E et al. (2025). Effect of Tribocorrosion on Mechanical Behavior of Titanium Dental Implants: An In Vitro Study. Materials (Basel). doi:10.3390/ma18051136 · in vitro
- Kristina Bertl et al. (2021). A Mini Review on Non-augmentative Surgical Therapy of Peri-Implantitis—What Is Known and What Are the Future Challenges? Frontiers in Dental Medicine. doi:10.3389/fdmed.2021.659361 · review
- Aušra Ramanauskaitė et al. (2020). Surgical Management of Peri-implantitis Current Oral Health Reports. doi:10.1007/s40496-020-00278-y · not classified
- Galarraga-Vinueza ME et al. (2020). Volumetric assessment of tissue changes following combined surgical therapy of peri-implantitis: A pilot study. J Clin Periodontol. doi:10.1111/jcpe.13335 · clinical study
- Aušra Ramanauskaitė et al. (2021). Efficacy of alternative or adjunctive measures to conventional non-surgical and surgical treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis International Journal of Implant Dentistry. doi:10.1186/s40729-021-00388-x · systematic review
- Zhi-Bang Li et al. (2022). The Effect of Nonaugmentative Approaches in the Surgical Treatment of Peri-implantitis: A Systematic Review and Network Meta-analysis The International Journal of Oral & Maxillofacial Implants. doi:10.11607/jomi.9211 · systematic review
- Baima G et al. (2022). Surface decontamination protocols for surgical treatment of peri-implantitis: A systematic review with meta-analysis. Clin Oral Implants Res. doi:10.1111/clr.13992 · systematic review
- Cruz RKS et al. (2025). Efficacy of implantoplasty in the treatment of peri-implantitis: A 24-month randomized controlled clinical trial. J Dent. doi:10.1016/j.jdent.2025.105844 · RCT
- Ravidà A et al. (2020). Lack of Clinical Benefit of Implantoplasty to Improve Implant Survival Rate. J Dent Res. doi:10.1177/0022034520944158 · clinical study
- Schwarz F et al. (2021). Peri-implantitis: Summary and consensus statements of group 3. The 6th EAO Consensus Conference 2021. Clin Oral Implants Res. doi:10.1111/clr.13827 · consensus
- Schwarz F et al. (2013). Four-year follow-up of combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination. J Clin Periodontol. doi:10.1111/jcpe.12143 · RCT
- Rayner Goh et al. (2022). The effect of implantoplasty on dental implant fracture resistance: a systematic review International Journal of Orofacial and Health Sciences. doi:10.31436/ijohs.v3i1.113 · systematic review
- Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. Clin Oral Implants Res. doi:10.1111/clr.70077 · systematic review
- Ravidà A et al. (2025). Efficacy of Decontamination Methods for Biofilm Removal from Dental Implant Surfaces and Reosseointegration: An AAP/AO Systematic Review on Peri-implant Diseases and Conditions. Int J Oral Maxillofac Implants. PMID 40476898 · systematic review
- Khayat P et al. (2026). Bone Regeneration Following Implantoplasty: A Retrospective Cohort Study with Long-Term Radiographic Assessment. Int J Periodontics Restorative Dent. doi:10.11607/prd.7422 · RCT
- Lee K et al. (2026). Overview of Treatment Modalities for Peri-Implantitis (Part 2). Compend Contin Educ Dent. PMID 42848526 · review
The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.
What the randomised clinical trials concluded
11 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.
Both groups showed favourable outcomes, demonstrating non-inferiority of titanium brushes to implantoplasty.
— Park SH et al. 2026, J Clin Periodontol; cited 8.Implantoplasty alone without osseous surgery, flap repositioning, or use of a graft material or membrane may be a viable option for managing peri-implantitis defects. However, future randomized clinical trials with larger sample sizes are necessary to validate current findings.
— Khayat P et al. 2026, Int J Periodontics Restorative Dent; cited 2.BIS enabled the accurate identification of mature biofilm and facilitated site‑specific, conservative decontamination. This selective approach, which targets infected surfaces while preserving implant structure, may be clinically advantageous for peri‑implantitis management. Further randomized controlled trials are warranted to validate these findings.
— Seo-Jun Lee et al. 2026, BMC Oral Health; cited 1.Combined surgical therapy for peri-implantitis, including implantoplasty and regeneration of the intrabony component, is effective in arresting disease progression and restoring peri-implant health. Extending implantoplasty to the contained intrabony compartment appears to provide additional clinical and radiographic benefits.
— Monje A et al. 2026, Clin Implant Dent Relat Res.Evidence is insufficient to suggest that incorporation of implantoplasty improves clinical parameters during the surgical treatment of peri‑implantitis, compared to mechanical debridement alone.
— Cruz RKS et al. 2025, J Dent; cited 6.Implantoplasty can generate a surface significantly less conducive to biofilm accumulation in the short term compared to pristine implants with turned or modified surfaces.
— Bertl K et al. 2024, Clin Exp Dent Res; cited 4.This pilot study indicated using laser irradiation during peri-implantitis regenerative therapy may aid in better probing PD reduction. Nonetheless, a larger sample size and longer follow-up is needed to confirm if Er:YAG laser irradiation provides additional clinical benefits for peri-implantitis regenerative therapy (Clinicaltrials.gov: NCT03127228).
— Wang CW et al. 2021, J Periodontol; cited 129.Within the limitations of this 6-month follow-up study, implantoplasty is as effective as glycine air polishing for the surgical treatment of peri-implantitis.
— Jérôme Frédéric Lasserre et al. 2020, The International Journal of Oral & Maxillofacial Implants; cited 70.Combined surgical resective/regenerative therapy of advanced peri-implantitis was effective on the long-term, but not influenced by the initial method of surface decontamination.
— Schwarz F et al. 2017, J Clin Periodontol; cited 185.The 4-year clinical outcomes obtained following combined surgical resective/regenerative therapy of advanced peri-implantitis were not influenced by the method of surface decontamination.
— Schwarz F et al. 2013, J Clin Periodontol; cited 148.
1 further RCT entry of this chapter are in the table below and in all entries.
What the systematic reviews and meta-analyses concluded
23 systematic reviews or meta-analyses mention this method; most cover several methods at once (the synthesis chapter lists all of them).
The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.
— Valeriani L et al. 2026, Clin Oral Implants Res; cited 3.Titanium particles generated during implantoplasty are detectable but show no consistent clinical association with peri-implantitis or significant inflammation. Implantoplasty may be applied selectively, although robust long-term clinical studies are still required. No protocol was registered.
— Rodríguez Alvarez MB et al. 2025, J Clin Med; cited 8.the tungsten carbide drills resulted in less fracture resistance loss than the diamond and tungsten carbide drills for the dental implants submitted to implantoplasty procedures. Systematic Review Registration: [http://www.prisma-statement.org], identifier [INPLASY202460018].
— Giovanni Pissu et al. 2025, Frontiers in Dental Medicine; cited 2.Implantoplasty reduces the mechanical strength of dental implants. Increased implantoplasty length correlates with decreased resistance, particularly affecting narrow implants. The prosthetic connection most affected by this procedure is the external hexagon, followed by the internal hexagon, with the conical connection being the most resistant.
— Manuel Alejandro León Velastegui et al. 2025, Journal of Clinical Medicine; cited 2.Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.
— Pappolla Sessa C et al. 2025, J Clin Med; cited 2.Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.
— Ravidà A et al. 2025, Int J Oral Maxillofac Implants.Owing to the limited available data, clinical efficacy of photo/mechanical and physical implant surface decontamination in conjunction with surgical peri-implantitis therapy is inconclusive. However, titanium brushes may be beneficial in reducing signs of inflammation.
— Ramanauskaite A et al. 2023, J Clin Periodontol; cited 44.Surgical regenerative treatment was a predictable option in the management of PI and in improving the clinical parameters of peri-implant tissues in the short term, mainly when using porous titanium granules, alloplastic bone grafts, and xenografts.
— Castro F et al. 2023, Saudi Dent J; cited 32.
15 further systematic review entries of this chapter are in the table below and in all entries.
Guideline and consensus mentions
Prosthesis overcontouring and impaired access to oral hygiene procedures increases risk for peri-implantitis. When indicated, reconstructive peri-implantitis treatment may facilitate the maintenance of post-operative peri-implant soft-tissue levels.
— Schwarz F et al. 2021, Clin Oral Implants Res; cited 163.
Clinical studies and case reports
22 non-randomised clinical studies and 19 case reports or series.
, including the small sample size, short follow-up period, and heterogeneity in implant-related factors such as prosthetic design, peri-implant soft tissue, implant systems, and surface characteristics, combined surgical therapy was associated with improvements in clinical and radiographic parameters in implants affected by peri-implantitis with complex bone defects.
— SunHo Ahn et al. 2026, Journal of Oral Implantology; cited 0.Surgical peri-implantitis outcome was associated with systemic antibiotic, surgeon, molar site, overdenture, baseline suppuration and PD.
— Zhou W et al. 2026, J Clin Periodontol.PDT as an adjunct to conventional peri-implantitis treatment with GBR resulted in statistically significantly lower PPD values. However, no additional benefits were observed for infection resolution, maintenance of infection-free status, MBL or BOP. Initial improvements in both groups followed by gradual recurrences in clinical parameters over 18 months.
— Arısan V et al. 2025, Oral Health Prev Dent.Individualized treatment plans are essential for managing peri-implant conditions effectively. Non-surgical therapies are effective for early-stage disease, while surgical interventions are necessary for advanced cases. Long-term success depends on integrating these approaches with regular follow-up care and patient education.
— Adnan Saeed Siddiqui et al. 2024, Insights-Journal of Health and Rehabilitation; cited 1.The absence of KM does not seem to have a negative effect on healing after therapy for the studied period of 3 years. The authors conclude that resective surgery combined with implantoplasty seems to be a reliable method for arresting the progression of peri-implantitis.
— Emmanuel Englezos et al. 2024, The International Journal of Periodontics & Restorative Dentistry; cited 0.Implantoplasty is more suitable for lateral areas. Implant surface polishing is indicated at implant sites where no bone regeneration is expected.
— Radu Bolun et al. 2024, Journal of Stomatological Medicine; cited 0.
16 further clinical study entries of this chapter are in the table below and in all entries.
Laboratory and animal findings
43 in vitro / ex vivo and 7 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.
Although a good agreement between numerical and experimental results was observed, these findings should be interpreted with caution due to the in vitro testing conditions and the assumptions inherent to the finite element simulations.
— Padullés-Roig E et al. 2026, J Funct Biomater; cited 3.Titanium particles released during implantoplasty induce pro-inflammatory responses.
— Gil J et al. 2026, Med Oral Patol Oral Cir Bucal; cited 1.Excessive marginal resection significantly decreases the fatigue resistance and long-term mechanical reliability of dental implants, particularly when combined with implantoplasty. The main limitations of this study include is in vitro design, the assumptions inherent to the numerical models, and the variability associated with implantoplasty procedures.
— Padullés-Roig E et al. 2026, Dent J (Basel); cited 1.Implants treated with IP in the phantom-head set-up exhibited significantly greater surface roughness and required longer procedural time compared to those treated in the table-top model, but did not influence material loss.
— Eamonn Donohoe et al. 2026, Clinical and Experimental Dental Research; cited 0.CA and H2O2 improved surface properties after implantoplasty, with CA providing the most favorable combination of corrosion resistance, minimal ion release and antibacterial effect.
— Millas L et al. 2026, Dent J (Basel); cited 0., the wettability and surface roughness of dental implant material surfaces were greatly impacted by all surface treatment techniques.By generating the lowest contact angle values, chemical cleaning with citric acid demonstrated the greatest increase in wettability.While glycine powder air-abrasion produced enhanced surface roughness with favorable wettability, mechanical implantoplasty/ polishing produced the …
— Naman Awasthi et al. 2026, The Journal of Contemporary Dental Practice; cited 0.
37 further in vitro entries of this chapter are in the table below and in all entries.
The surgical treatment of peri-implantitis lesions remains challenging. Soft tissue grafting showed clinical benefits by reducing changes in the peri-implant mucosa. The effect of hard tissue grafting on bone regeneration was very limited.
— Young Woo Song et al. 2026, Journal of Periodontal & Implant Science; cited 2.When applying DexNPs, bone bridging processes were located surrounding the CaP biomaterial. The presence of Tid reduces the bone healing and DexNPs doped on CaP produced an increase in the osteogenic potential, improving the bone defect closure.
— Toledano M et al. 2026, Dent Mater; cited 1.Tid tended to increase the M1/M2 ratio, leading to a pro-inflammatory cellular profile. Dex-NPs with CaP prompted the M1/M2 ratio decrease in the presence of Tid. Hence, reducing Tid-induced inflammation and osteolysis and thus gaining both osteoconductivity and neovascularization within the bone defect.
— Toledano M et al. 2026, J Dent; cited 0.Although further studies are required to confirm the clinical relevance of these results, Ti metal particles in the jaw might increase the concentration of metal ions in vital organs and induce a foreign body reaction.
— Toledano-Serrabona J et al. 2023, J Periodontol; cited 43.
3 further animal study entries of this chapter are in the table below and in all entries.
Parameters as stated in the abstracts
Three surfaces were analyzed: physiological saline (Ctr), 25% citric acid (AC), and citric acid with collagen and magnesium nitrate hexahydrate (AC500/Mg).
— Oliván S et al. 2026 (in vitro).There was a large heterogeneity of methods for treating PI: (1) resective surgery with osteoplasty and surface debridement (implantoplasty, IP); (2) the use of medications/antiseptic (0.12% chlorhexidine + 0.05% cetylpyridinium chlorine) or acids (phosphoric acid 35%); and (3) adjunctive use of laser.
— Smail Belasla et al. 2025 (review).They were treated with four different solutions: 25% citric acid, 25% citric acid with the addition of collagen 0.25 g/L, 25% citric acid with the addition of 0.50 g/L and the latter with the addition of 1% Mg (NO3)2.
— Pilar Fernández-Garrido et al. 2024 (in vitro).Subsequently, a minimum of four series of cyclic loads were applied with a servo-hydraulic mechanical testing machine (5 × 106 cycles at 15 Hz, between a maximal nominal value-starting at 529 N in the IP group and 735 N in the control group-and 10% of that force).
— Octavi Camps‐Font et al. 2023 (in vitro).The other microimplants were divided into seven different decontamination protocols (12 S/R per group): 24% EDTA, 2% chlorhexidine (CHL), gauze soaked in 2% chlorhexidine (GCHL), gauze soaked in ultrapure water (GMQ), scaling (SC), titanium brush (TiB), and implantoplasty (IP).
— Stuani VT et al. 2021 (in vitro).The shortest treatment time was recorded for group AS (13 ± 2 min) and the longest for CDG (21 ± 2 min) and BG (21 ± 4 min).
— Ramel CF et al. 2016 (in vitro).
One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.
Products and manufacturers named
Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.
- Perio-Flow — 3 entries
- Air-Flow — 3 entries
- Ti-Brush — 2 entries
- i-Brush — 2 entries
- TiBrush — 1 entry
- Cavitron — 1 entry
- Vector — 1 entry
Manufacturers: Straumann (7), Komet (6), Geistlich (5), KaVo (5), EMS (4), Hu-Friedy (3), Nobel Biocare (2), Zimmer (2), Dentsply (2), Neobiotech (1), Dentium (1), BioHorizons (1), W&H (1), Zimmer Biomet (1), Sirona (1).
Availability of named products, as far as public company information shows
Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.
- TiBrush (Straumann) — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.
Chemical agents used alongside
Agents named in the same papers (18 different): chlorhexidine (19), saline (19), antibiotics (systemic) (12), hydrogen peroxide (12), citric acid (11), amoxicillin (8), EDTA (3), sterile water (3), phosphoric acid / etching gel (3), tetracycline (3), minocycline (3), metronidazole (3), hypochlorous acid (2), doxycycline (2), enamel matrix derivative (2), povidone-iodine (2), photosensitizer dye (2), chloramine (1). Chapter 13 collects the chemical literature.
Limitations of this chapter
- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the how this reader is made page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.
Entries in this chapter (154)
Related chapters
- 13. Chemical and antiseptic agents
- 5. Lasers
- 4. Air-polishing and air-abrasive devices
- 3. Titanium and nickel-titanium brushes
- 14. Synthesis — what the systematic reviews and consensus reports conclude
- 17. All entries — the searchable table
This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to chapter 15. Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).
