Surgical surface decontamination overall Guideline / review | Clinical practice guideline (EFP S3, 2023) | Saline-soaked gauze, curettes, titanium brushes, air-polishing, lasers, implantoplasty, chemical agents | Recommendation grades by method | Gauze and curettes as the reference; titanium brushes may be considered as an alternative or adjunct (R8.11, grade O); chlorhexidine and photodynamic therapy suggested not to be used for surface decontamination during surgery (R8.12, grade B). Overall quality of evidence low. | 10.1111/jcpe.13823 |
Non-reconstructive and combined surgery Guideline / review | Clinical practice guideline (German S3, 2022) | Titanium brush, glycine air-polishing, lasers, antiseptics | Recommendation grades by method | Evidence for a titanium brush and glycine air-polishing in non-reconstructive surgery; adjunctive antiseptics should not be used there (Rec. 18, grade B). An adjunctive titanium brush can be dispensed with in combined surgery (Rec. 20, grade 0). | AWMF 083-023 |
Mechanical and physical decontamination Guideline / review | Systematic review (Ramanauskaite et al. 2023) | Mechanical and physical methods during surgery | Five randomised trials of surgical decontamination | Data limited, clinical efficacy inconclusive; the authors state that titanium brushes may be beneficial in reducing signs of inflammation. | 10.1111/jcpe.13783 |
Reconstructive surgery + bone substitute Both arms: NiTi Brush | Multicentre RCT (Derks et al. 2022), 138 patients / 147 implants | NiTi Brush NANO, ≤1,200 rpm, saline irrigation | Bone substitute vs none | At 12 months probing depth reduced by about 3.7 mm and bone gained about 1.0 mm (whole treatment); the brush’s own effect is not isolated. | 10.1111/clr.13972 |
The same trial at 3 years Both arms: NiTi Brush | 3-year follow-up of the RCT (Alibegovic et al. 2025) | NiTi Brush NANO | Bone substitute vs none | At 3 years probing depth reduced by 3.2–3.5 mm; 14 of 127 implants (11%) lost; disease resolution 39%. Shows the limits of long-term outcomes. | 10.1111/clr.14393 |
Reconstructive surgery + membrane Both arms: NiTi Brush | RCT (Regidor et al. 2023), 43 patients | NiTi Brush NANO, ≤1,200 rpm | Resorbable membrane vs none | No implant lost at 12 months; the comparison was the membrane. | 10.1111/jcpe.13796 |
Reconstructive surgery + membrane Both arms: NiTi Brush | RCT (Monje et al. 2023), 33 patients / 48 implants | NiTi Brush, 600 rpm, about 2–3 min | Barrier membrane vs none | Mean disease resolution 77.1% at 12 months (whole treatment). | 10.1002/JPER.22-0511 |
Mechanical + adjunct (hydrogen peroxide or electrolytic cleaning) Both arms: NiTi Brush | Multicentre RCT (Monje et al. 2025), 58 patients | NiTi Brush, 600 rpm, about 2–3 min, then hydrogen peroxide or electrolytic cleaning | Adjunct: electrolytic cleaning vs hydrogen peroxide | Disease resolution at 12 months 87.5% vs 64.5%; the difference was not statistically significant (p = 0.08). Both groups used the NiTi Brush for mechanical cleaning. No major complications. | 10.1111/cid.70075 |
Mechanical alone vs mechanical + electrolytic cleaning Both arms: NiTi Brush | RCT (Regidor et al. 2026), 40 patients / 44 implants | NiTi Brush NANO, ≤1,200 rpm; electrolytic cleaning added in the test group | Brush alone (control) vs brush + electrolytic cleaning | At 12 months probing depth reduced by 4.5 and 3.8 mm and bone gained 1.9 and 2.1 mm; no significant difference between the groups. | 10.1111/clr.70152 |
Flap surgery vs laser Treatment comparison · NiTi Brush in one arm | RCT (Malmqvist et al. 2025), 26 patients / 29 implants | NiTi Brush POCKET in the flap-surgery arm; control diode laser | Flap surgery (with brush) vs diode-laser treatment | Proportion of improved patients similar at 6 months; probing-depth reduction in improved patients 1.81 vs 0.83 mm. The brush was used in one arm only; whole treatments were compared. | 10.1002/JPER.24-0683 |
Adding a brush Direct comparison Other maker's brush | RCT (de Tapia et al. 2019) and 5-year follow-up (2025) | Titanium brush of another manufacturer, with hydrogen peroxide and plastic ultrasonic tips | The same treatment with vs without a brush | At 12 months probing-depth reduction 4.87 vs 2.85 mm (p = 0.009) in favour of the brush group; at 5 years the reduction was maintained with slight progression, and the difference between the groups was not statistically significant (p = 0.159). | 10.1111/jcpe.13095 10.1002/jper.24-0673 |
Mechanical instruments compared Direct comparison Other maker's brush | RCT (Toma et al. 2019) | Titanium brush of another manufacturer, plastic curettes, air-abrasive device | The three instruments | At 6 months greater probing-depth reduction in the titanium-brush group than in the other groups (P < 0.001); successful outcome in 22% (curettes), 27% (air-abrasive) and 33% (brush) of implants — treatment success low in all groups. | 10.3390/jcm8070966 |
Brush vs implantoplasty Direct comparison Other maker's brush | RCT, non-inferiority design (Park et al. 2026) | Titanium brush of another manufacturer (a further brush added in some implants) | Titanium brush vs implantoplasty | Probing depth reduced by 3.6 and 3.3 mm; non-inferiority of the brush reported; decontamination time 3 min 1 s vs 5 min 27 s. | 10.1111/jcpe.70056 |
Several surgical protocols All protocols: NiTi Brush | Retrospective cohort (Zhou et al. 2026), 223 patients / 406 implants | NiTi Brush after removal of granulation tissue with curettes | Four surgical protocols | Mean follow-up 30.8 months; treatment success at 1 year 54.7%; no significant difference between the protocols. | 10.1111/jcpe.70115 |
Mechanical methods compared Laboratory Direct comparison | In vitro (Ichioka et al. 2023) | NiTi Brush 1,200 rpm, air-polishing, gauze and others | Protocols with each other (3D-printed defect model) | Protocols including a brush or air-polishing removed more biofilm than gauze; no protocol removed it completely. | 10.1111/clr.14136 |
Titanium particle release Laboratory Direct comparison | In vitro (Kao et al. 2024) | NiTi Brush OMEGA, ultrasonic (metal and PEEK tips), erythritol air-polishing | Particles released per method | NiTi Brush 6.45 µg per disc, metal-tip ultrasonic 34.0–34.4 µg; erythritol air-polishing and the PEEK tip released less. | 10.3390/dj12050123 |
Brush, polishing brush and agents Laboratory | In vitro (Brunello et al. 2025) | NiTi Brush NANO, diamond polishing brush, agents | Surface morphology and cell compatibility | Cell viability in the saline-stored NiTi Brush group significantly higher than in all other groups except the air-stored NiTi Brush group and the machined surface; working time shorter than with the polishing brush. | 10.1111/cid.13417 |
Contact vs non-contact cleaning Laboratory Direct comparison | Laboratory (Jazaeri et al. 2026) | NiTi Brush 1,200 rpm, titanium curette, non-contact water jet | The three methods | The brush and the titanium curette altered micro-rough surfaces and left viable bacteria; the water jet reduced viable bacteria by more than 90.9% and preserved roughness. | 10.1002/jper.11371 |
Four rotary brushes on the surface Laboratory Direct comparison | Laboratory (Alabbad et al. 2025) | NiTi Brush NANO and three other rotary brushes, 60 s | Brushes with each other, untreated control | Scratches, flattening and titanium particles with three brushes including the NiTi Brush; roughness and wettability changed. | 10.1016/j.dental.2024.12.014 |