Study summary of“Defect angle as prognostic indicator in the reconstructive therapy of peri-implantitis”

Monje A, Pons R, Sculean A, Nart J, Wang H-L. Clinical Implant Dentistry and Related Research 2023;25(6):992–999. doi:10.1111/cid.13244

Summary prepared by HANS KOREA — not the original paper

Why we present this paper

This page is published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush1. We share selected peer-reviewed studies so that clinicians who use the NiTi Brush can see how it was used in published clinical protocols, with the ultimate aim of better outcomes for patients.

Independence

The study was designed, conducted and published independently by its authors. The authors and the publisher are not associated with this page and do not endorse HANS Korea or its products. According to the paper’s conflict-of-interest statement, the authors declare no conflicts of interest.

About this study

This paper investigates how the shape of the bone defect (defect angle) influences the outcome of reconstructive surgery for peri-implantitis. As part of the surgical protocol described by the authors, NiTi brushes were used for surface decontamination of the exposed implant surface.

How the NiTi Brush was used in this study

As reported by the authors.

ItemAs reported in the paper
InstrumentNiTi Brush (HANS Korea), named in the paper as “NiTi brushes” with the manufacturer given as Hans Korea Co., Gyeonggi-do, Korea
Step in the protocolSurface decontamination (the authors’ term) of the exposed implant surface, after removal of granulation tissue and, where uncontained defect components were present, implantoplasty
Speed600 rpm
Brushing timeAbout 2–3 minutes
IrrigationThe paper does not state whether irrigation was used while brushing; brushing was followed by hydrogen peroxide (3%) for 2 minutes and irrigation with saline

The study at a glance

Secondary analysis of a randomized clinical trial (NCT05282667): 33 patients with 48 implants with peri-implantitis and an intrabony component, treated by reconstructive surgery with an allograft with or without a collagen membrane and followed for 12 months. The authors conclude that the baseline defect angle of the intrabony component predicts radiographic bone gain.

The main report of the same trial is summarized separately: Monje et al. 2023, Journal of Periodontology.

Please read the original paper

For the methods, results and limitations, see the original article (open access): https://doi.org/10.1111/cid.13244

Reported study conditions are the authors’ and may differ from the Instructions for Use. Use the NiTi Brush only as described in the IFU (implant motor, 600–1,200 rpm, external saline irrigation, single use).

Source: Monje A, Pons R, Sculean A, Nart J, Wang H-L. Clin Implant Dent Relat Res 2023;25(6):992–999, © 2023 The Authors, published by Wiley Periodicals LLC, licensed under CC BY 4.0. Summary and table by HANS Korea; wording adapted.

Contact and removal. If you are an author of this paper or its publisher and would prefer this page not to appear, or if you believe it affects your rights or reputation in any way, please write to [email protected]. At the request of the authors or the publisher, we will remove the page promptly. Any other concern will be reviewed promptly and the page corrected or removed where appropriate.

1 The NiTi Brush is a rotary brush with nickel-titanium alloy bristles, developed by HANS Korea since 2010. Rotary brushes of this kind are generically called “titanium brushes” (see What is a titanium brush); the official product name is NiTi Brush for Peri-implantitis. ↩