# 8. Ultrasonic, sonic and piezoelectric instruments

Chapter 8 of an evidence-based reader on implant surface decontamination in peri-implantitis: 148 entries on ultrasonic, sonic and piezoelectric instruments — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about ultrasonic and piezoelectric scalers for implant surface debridement?

**Key facts — Ultrasonic, sonic and piezoelectric instruments**

- Entries in this chapter: 148 of 819 (2005–2026): RCT 15 · clinical study 15 · case report/series 12 · systematic review 15 · review 11 · in vitro 74 · animal study 2 · not classified 4
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Figuero E et al. 2014](https://doi.org/10.1111/prd.12049) (521); [Rokaya D et al. 2020](https://doi.org/10.1055/s-0040-1715779) (293)
- Products named by the authors: Piezon (9), Air-Flow (5), AIRFLOW (4), Perisolv (3), Waterlase (3), Perio-Flow (2), GalvoSurge (2), Cavitron (2), Vector (2), PIEZON (1)
- Manufacturers named by the authors: EMS (17), Straumann (7), Geistlich (5), Biolase (4), Dentium (4), Hu-Friedy (4), Dentsply Sirona (3), Acteon (3), Fotona (3), Nobel Biocare (3)
- Chemical agents used alongside: chlorhexidine (34), saline (25), hydrogen peroxide (19), antibiotics (systemic) (11), citric acid (11), tetracycline (9), amoxicillin (7), photosensitizer dye (7)
- Often studied together with: [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (84), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (71), [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) (53), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (39)
- Entries naming the NiTi Brush: 4 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Powered scalers whose tip oscillates at ultrasonic (magnetostrictive or piezoelectric) or sonic frequency, with tips of stainless steel, titanium, plastic, carbon fibre or PEEK. They are the conventional non-surgical instruments to which newer measures are compared in many trials.


### Mechanism and use, as the papers describe it

Ultrasonic and sonic scalers in the publications in this chapter are powered instruments whose tip oscillates against the implant surface under water irrigation; Mann et al. recorded an elliptical oscillation with the maximum amplitude at the probe tip.[1,2] Tips are described as made of stainless steel, titanium, polyetheretherketone (PEEK), carbon fibre, resin, ceramic and plastic, and as metal inserts with a plastic sleeve or a PEEK fibre coating.[3,4,5,6] Piezoelectric and sonic-driven (air) scalers both appear, and the Vector system is named as a novel ultrasonic device in one trial.[7,8,9] A 2017 review of mechanical instruments noted that ultrasonic systems with different tips had been tested to enhance cleaning around implants.[10]

Clinically the instruments are used for submarginal debridement of peri-implant mucositis and peri-implantitis without flap elevation, alone or combined with curettes or air-polishing.[11,12,13] In surgical protocols ultrasonics with plastic or PEEK tips have been the mechanical step before chemical agents, grafting or titanium brushing, and ultrasonics with glycine air-polishing formed the surface decontamination in a surgical case series.[14,15,16] Ultrasonic PEEK inserts are also used in supportive peri-implant care on implants restored with ceramic crowns.[17] Tang et al. reported in vitro that ultrasonic scaling removed calcified deposits that glycine air-polishing could not, and Munakata et al. reported a titanium ultrasonic scaler removing a hydroxyapatite coating more completely in deeper parts of a circumferential defect model.[18,19] A survey of dental hygiene professionals found that most Israeli respondents used only hand and sonic or ultrasonic instruments for peri-implant cleaning.[20]


### Reported operating conditions

Laboratory abstracts state contact loads of 25 g, 30 g, 100 g and 200 g, power settings described as low and medium, as 3 of 10 at 25 to 32 kHz, and as 4 W at 20 Hz for a ceramic-tipped scaler.[21,2,3,1,22,4] Instrumentation times are reported as 10 s under continuous automatic motion, 30 scaling motions, 40 strokes with the tip angled tangentially, 20 strokes in 40 s or 100 strokes in 200 s to simulate one or five years of supportive care, 30 s, 60 s, and 120 s.[3,21,2,23,5,24,25] Unursaikhan et al. applied piezoelectric tips at 15° and 45° and concluded that surface change depended more on tip hardness than on application angle, and Mann et al. found that load and power governed the width of defects left by a metallic insert.[7,1]

In clinical trials, ultrasonic debridement was repeated at 3-month intervals over 6 to 12 months, and Discepoli et al. reported in vitro that wider prosthetic emergence angles and deeper mucosal tunnels reduced the efficacy of submucosal ultrasonic debridement.[9,26,27]


### Effects on the implant surface reported in laboratory studies

Metal tips are repeatedly reported to alter titanium: a stainless steel tip caused pronounced macroscopic damage and increased roughness in the thread area, all ultrasonic scaling of SLA implants produced detectable damage to the SLA layer, and metallic devices caused scratching, gouging and material loss on titanium abutments.[28,21,29] Sahrmann et al. found that all tip materials except resin reduced the roughness of two moderately rough surfaces, while steel and titanium tips increased the roughness of untreated and machined surfaces, and that PEEK, carbon and resin tips left extensive residuals matching their own composition.[3] Plastic or PEEK remnants on the implant surface are also reported by Cha et al., Qian et al. and Mann et al., who described a polishing action of plastic-coated probes with minimal damage but plastic deposits left behind.[28,30,1] Giannelli et al. observed incomplete removal of the titanium dioxide layer and marked surface changes on anodised discs after a metal tip, and Gianfreda et al. reported that anodised surfaces tended to lose the anodising layer.[31,32] A 2026 systematic review found no consistent pattern of roughness change on machined titanium across decontamination methods.[33]

Titanium release is quantified in three studies: all scaled SLA implants produced titanium particles in the coolant water, a metal tip released 34 µg of titanium at low and medium power with particle sizes near 1 µm and PEEK tips also contained titanium, and a conventional ultrasonic insert released 0.0047 ppm whereas an insert with a plastic sleeve released none.[21,22,5] Residual biofilm results vary: ultrasonic instrumentation left no residual bacteria on shot-blasted discs but deposited foreign material on 3% to 11% of the area, a PEEK tip reduced a multispecies biofilm on SLA implants, and PEEK and stainless steel tips removed less ink than air-polishing or a titanium brush in intraosseous defect models.[34,25,35] Stein et al. reported effective biofilm inactivation, re-exposure of surface elements and favourable gingival fibroblast cytocompatibility after a stainless steel ultrasonic scaler, Giannelli et al. reported preserved osteoblast biocompatibility with disc temperature below 47 °C, and Cao et al. reported reduced fibroblast proliferation on machined discs after metal and carbon fibre tips.[36,31,37] On zirconia, a stainless steel tip significantly increased roughness and left grey metallic residue, whereas a 2021 systematic review found minimal to no damage from non-metal tips.[38,39]


### Position in treatment protocols

Ultrasonic debridement is the conventional non-surgical arm in several comparisons: Renvert et al. found no group differences between titanium hand instruments and an ultrasonic device for peri-implantitis, Karring et al. found no significant difference between the Vector system and carbon fibre curettes, and Bengtsson et al. reported effective treatment of mucositis with either an Er:YAG laser or an ultrasonic scaler.[11,9,26] The 2015 meta-analysis by Schwarz et al. defined conventional non-surgical treatment as mechanical or ultrasonic debridement, and Verket et al. found no difference between glycine air-polishing and ultrasonic cleaning and no added effect of air-polishing over ultrasonics in mucositis.[40,41] In the Cochrane review by Grusovin et al. no statistically significant difference was found between a titanium curette and an ultrasonic debridement tool for mucositis.[42]

Ultrasonics also serve as the comparator or baseline in air-polishing trials and as the control arm against which chitosan brushes with antiseptics were added.[43,17,44] In surgery, plastic ultrasonic scalers with 3% hydrogen peroxide formed the control decontamination in a regenerative trial, PEEK-coated tips with erythritol air-flow were compared with plastic scalers and chlorhexidine, and in a dog model an ultrasonic device with chlorhexidine was compared with TiBrush.[14,15,45]


### Limitations and open questions as stated by the authors

Review authors describe the trials as small with short follow-up and the evidence as low quality, and conclude that no beneficial effect of one instrumentation over another could be demonstrated for mucositis.[42,46,41] Renvert et al. observed higher total bacterial counts immediately and at one week after ultrasonic treatment and no effect on probing depth, and Selimović et al. concluded that conventional ultrasonic and curette management produced limited clinical improvement.[11,12] Harrel et al. urged great caution with ultrasonic scalers around implants because every scaled implant released titanium particles, and Kao et al. and Romanos et al. raised the possible biological consequences of released titanium.[21,22,5] Sahrmann et al. noted that all ultrasonic instruments led to microscopic alterations of every surface tested, Colombo et al. called for study of material release from non-metallic inserts, and Louropoulou et al. stated that the clinical impact of in vitro cleaning findings requires clarification.[3,47,48]


### Sources cited in this description (48)

1. M F St J Mann et al. (2011). Effect of plastic‐covered ultrasonic scalers on titanium implant surfaces *Clinical Oral Implants Research*. https://doi.org/10.1111/j.1600-0501.2011.02186.x · in vitro
2. Francesco Faccioni et al. (2017). Ultrasonic instrument effects on different implant surfaces *ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/)*. https://doi.org/10.23805/jo.2017.09.01.06 · in vitro
3. Philipp Sahrmann et al. (2021). Assessment of implant surface and instrument insert changes due to instrumentation with different tips for ultrasonic-driven debridement *BMC Oral Health*. https://doi.org/10.1186/s12903-020-01384-0 · in vitro
4. Matys J et al. (2019). Temperature Changes and SEM Effects of Three Different Implants-Abutment Connection during Debridement with Er:YAG Laser: An Ex Vivo Study. *Materials (Basel)*. https://doi.org/10.3390/ma12223748 · in vitro
5. Romanos GE et al. (2026). Spectrometric Analysis of Titanium Particle Release Based on Various Implant Surface Detoxification Methods. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11375 · in vitro
6. Menini M et al. (2021). Efficacy of air-polishing devices without removal of implant-supported full-arch prostheses. *Int J Oral Implantol (Berl)*. https://pubmed.ncbi.nlm.nih.gov/34726849/ · RCT
7. Unursaikhan O et al. (2012). Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2012.42.3.88 · in vitro
8. Ziebolz D et al. (2017). Comparison of different maintenance strategies within supportive implant therapy for prevention of peri-implant inflammation during the first year after implant restoration. A randomized, dental hygiene practice-based multicenter study. *Am J Dent*. https://pubmed.ncbi.nlm.nih.gov/29178700/ · RCT
9. Karring ES et al. (2005). Treatment of peri-implantitis by the Vector system. *Clin Oral Implants Res*. https://doi.org/10.1111/j.1600-0501.2005.01141.x · RCT
10. Fabiana Almeida Curylofo‐Zotti et al. (2014). instrumentation of dental implants: a literature review *RSBO*. https://doi.org/10.21726/rsbo.v10i1.900 · review
11. Renvert S et al. (2009). Mechanical non-surgical treatment of peri-implantitis: a double-blind randomized longitudinal clinical study. I: clinical results. *J Clin Periodontol*. https://doi.org/10.1111/j.1600-051X.2009.01421.x · RCT
12. Armin Selimović et al. (2023). Non-surgical treatment of peri-implantitis with and without erythritol air-polishing a 12-month randomized controlled trial *BMC Oral Health*. https://doi.org/10.1186/s12903-023-02973-5 · RCT
13. Aloy-Prósper A et al. (2020). Effect of a single initial phase of non-surgical treatment of peri-implantitis: Abrasive air polishing versus ultrasounds. A prospective randomized controlled clinical study. *J Clin Exp Dent*. https://doi.org/10.4317/jced.56653 · RCT
14. de Tapia B et al. (2019). The adjunctive effect of a titanium brush in implant surface decontamination at peri-implantitis surgical regenerative interventions: A randomized controlled clinical trial. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13095 · RCT
15. Oncu Elif (2019). Comparision Effectiveness of Two Different Implant Surface Decontamination Methods by Surgical Treatment of Periimplantitis: A Clinical Trial *Journal of Surgery and Surgical Research*. https://doi.org/10.17352/jssr.000062 · RCT
16. Fernando Luengo et al. (2022). Clinical, Microbiological, and Biochemical Impact of the Surgical Treatment of Peri-Implantitis—A Prospective Case Series *Journal of Clinical Medicine*. https://doi.org/10.3390/jcm11164699 · case report/series
17. Carolina Maiorani et al. (2025). Effectiveness of Erythritol-Based Air Polishing and Ultrasonic Instrumentation with PEEK Inserts in Peri-Implant Maintenance: A Randomized Clinical Trial Including Different Prosthetic Materials *Dentistry Journal*. https://doi.org/10.3390/dj13060235 · RCT
18. Tang C et al. (2025). Combining Glycine Powder Air-Polishing and Ultrasonic Scaling for Bone Regeneration Around Infected Dental Implants. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/cid.70042 · in vitro
19. Munakata M et al. (2022). Effects of implant surface mechanical instrumentation methods on peri-implantitis: An in vitro study using a circumferential bone defect model. *J Dent Sci*. https://doi.org/10.1016/j.jds.2021.08.018 · in vitro
20. Peter Eickholz et al. (2022). Common practices of dental implants maintenance among dental hygiene professionals in Israel and Germany *International Journal of Dental Hygiene*. https://doi.org/10.1111/idh.12612 · clinical study
21. Harrel SK et al. (2019). Titanium particles generated during ultrasonic scaling of implants. *J Periodontol*. https://doi.org/10.1002/JPER.18-0230 · in vitro
22. Kao A et al. (2024). Quantity and Size of Titanium Particles Released from Different Mechanical Decontamination Procedures on Titanium Discs: An In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj12050123 · in vitro
23. Sirinirund B et al. (2019). Effects of Mechanical Instrumentation with Commercially Available Instruments Used in Supportive Peri-implant Therapy: An In Vitro Study. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.7409 · in vitro
24. Louisa Vierling et al. (2024). Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study *Dentistry Journal*. https://doi.org/10.3390/dj12050136 · in vitro
25. Khan SN et al. (2025). The Decontamination Effect of an Oscillating Chitosan Brush Compared With an Ultrasonic PEEK-Tip: An In Vitro Study Using a Dynamic Biofilm Model. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14360 · in vitro
26. Viveca Wallin Bengtsson et al. (2025). Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-025-00591-0 · RCT
27. Discepoli N et al. (2025). Influence of Emergence Angle and Mucosal Tunnel Depth on Artificial Biofilm Removal Around Dental Implants: An In Vitro Study. *Int J Dent*. https://doi.org/10.1155/ijod/7500003 · in vitro
28. Cha JK et al. (2019). The effect of five mechanical instrumentation protocols on implant surface topography and roughness: A scanning electron microscope and confocal laser scanning microscope analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13446 · in vitro
29. Kamel MS et al. (2026). Cleaning Efficacy and Surface Alterations of Titanium and Zirconia Implant Abutments Following Mechanical Instrumentation: An In Vitro Study. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70182 · in vitro
30. Qian Y et al. (2022). Cleaning effects of decontamination methods on clinically failed TiUnite implants and their impacts on surface roughness and chemistry: An in vitro pilot study. *Int J Oral Implantol (Berl)*. https://pubmed.ncbi.nlm.nih.gov/35546724/ · in vitro
31. Giannelli M et al. (2017). Effects of an Erbium:Yttrium-Aluminum-Garnet Laser and Ultrasonic Scaler on Titanium Dioxide-Coated Titanium Surfaces Contaminated With Subgingival Plaque: An In Vitro Study to Assess Post-Treatment Biocompatibility With Osteogenic Cells. *J Periodontol*. https://doi.org/10.1902/jop.2017.170195 · clinical study
32. Gianfreda F et al. (2022). The Effects of Ultrasonic Scaling and Air-Abrasive Powders on the Decontamination of 9 Implant-Abutment Surfaces: Scanning Electron Analysis and In Vitro Study. *Dent J (Basel)*. https://doi.org/10.3390/dj10030036 · in vitro
33. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
34. Ichioka Y et al. (2022). Mechanical removal of biofilm on titanium discs: An in vitro study. *J Biomed Mater Res B Appl Biomater*. https://doi.org/10.1002/jbm.b.34978 · in vitro
35. Luengo F et al. (2022). In vitro effect of different implant decontamination methods in three intraosseous defect configurations. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13991 · in vitro
36. Stein JM et al. (2023). Antimicrobial efficiency and cytocompatibility of different decontamination methods on titanium and zirconium surfaces. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.14014 · in vitro
37. Cao J et al. (2018). Influence on proliferation and adhesion of human gingival fibroblasts from different titanium surface decontamination treatments: An in vitro study. *Arch Oral Biol*. https://doi.org/10.1016/j.archoralbio.2017.12.013 · in vitro
38. Tan NCP et al. (2022). Impact of physical decontamination methods on zirconia implant surface and subsequent bacterial adhesion: An in-vitro study. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.486 · in vitro
39. Tan NCP et al. (2021). The effects of physical decontamination methods on zirconia implant surfaces: a systematic review. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2005080254 · systematic review
40. Frank Schwarz et al. (2015). Efficacy of alternative or adjunctive measures to conventional treatment of peri-implant mucositis and peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-015-0023-1 · systematic review
41. Verket A et al. (2023). Non-surgical therapy of peri-implant mucositis-Mechanical/physical approaches: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13789 · systematic review
42. Grusovin MG et al. (2010). Interventions for replacing missing teeth: maintaining and recovering soft tissue health around dental implants. *Cochrane Database Syst Rev*. https://doi.org/10.1002/14651858.CD003069.pub4 · systematic review
43. Shiai Dai et al. (2026). Non-surgical treatment of peri-implantitis with submarginal erythritol air-polishing in severe periodontitis patients: a randomized controlled trial *BMC Oral Health*. https://doi.org/10.1186/s12903-026-07721-z · RCT
44. Mayer Y et al. (2020). A nonsurgical treatment of peri-implantitis using mechanic, antiseptic and anti-inflammatory treatment: 1 year follow-up. *Clin Exp Dent Res*. https://doi.org/10.1002/cre2.286 · clinical study
45. Carral C et al. (2016). Mechanical and chemical implant decontamination in surgical peri-implantitis treatment: preclinical "in vivo" study. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12566 · animal study
46. Esposito M et al. (2008). The efficacy of interventions to treat peri-implantitis: a Cochrane systematic review of randomised controlled clinical trials. *Eur J Oral Implantol*. https://pubmed.ncbi.nlm.nih.gov/20467649/ · systematic review
47. Jacopo Colombo et al. (2025). Impact of Professional Hygiene Instruments on the Roughness of Implant Surfaces: An In Vitro Analysis *Applied Sciences*. https://doi.org/10.3390/app152312598 · in vitro
48. Louropoulou A et al. (2014). The effects of mechanical instruments on contaminated titanium dental implant surfaces: a systematic review. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.12224 · systematic review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

15 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “In patients with severe periodontitis, both non-surgical therapies were effective in improving clinical parameters of peri-implantitis. Erythritol air-polishing exhibited greater improvement in soft tissue inflammation. Adequate peri-implant keratinized mucosa and greater reduction in probing depth of adjacent teeth were identified as favorable prognostic factors for PPD.” — [Shiai Dai et al. 2026](https://doi.org/10.1186/s12903-026-07721-z), BMC Oral Health; cited 1.
- “Abrasive cleaning showed a transient increased trend in titanium concentration after non-surgical therapy, returning to baseline at 1 year after flap surgery. Overall, abrasive treatment produced inferior clinical outcomes and progressive bone loss in several cases, suggesting that abrasive cleaning is an adverse factor for regenerative treatment.” — [Kotsakis GA et al. 2026](https://doi.org/10.1002/jper.70158), J Periodontol; cited 0.
- “Treatment of peri-implant mucositis was effective regardless of whether the treatment was performed with an Er:YAG laser or an ultrasonic scaler. Fewer diseased sites were diagnosed at six months following laser treatment. TRIAL REGISTRATION: Registered at www. CLINICALTRIALS: gov : study no, NCT05772299.” — [Viveca Wallin Bengtsson et al. 2025](https://doi.org/10.1186/s40729-025-00591-0), International Journal of Implant Dentistry; cited 6.
- “Both erythritol-based air polishing and ultrasonic instrumentation with PEEK inserts are effective and comparable in the maintenance of peri-implant health. As treatment outcomes were independent of crown composition, the choice between modalities should be tailored to patient-specific needs and clinical conditions.” — [Carolina Maiorani et al. 2025](https://doi.org/10.3390/dj13060235), Dentistry Journal; cited 3.
- “Air polishing proved to be the most effective peri-implant mucosa cleaning protocol for reducing microbial biofilm formation, followed by ultrasonic cleaning. Manual brushing alone showed limited efficacy in controlling biofilm. Implementing efficient cleaning protocols is crucial for preventing peri-implant diseases and enhancing implant success.” — [Mukesh Soni et al. 2025](https://doi.org/10.4103/jpbs.jpbs_1923_24), Journal of Pharmacy And Bioallied Sciences; cited 0.
- “This study confirms that conventional non-surgical management of peri-implantitis produces limited clinical improvement. It is shown that an erythritol air-polishing system may not produce added clinical benefits when used adjunctive to conventional non-surgical management. In other words, neither approach effectively resolved peri-implantitis.” — [Armin Selimović et al. 2023](https://doi.org/10.1186/s12903-023-02973-5), BMC Oral Health; cited 28.
- “Glycine powder air polishing is a highly effective and comfortable treatment to maintain good oral hygiene in clinical practice, and could be used as an alternative to manual and mechanical instrumentation when dealing with implant-supported restorations.” — [Menini M et al. 2021](https://pubmed.ncbi.nlm.nih.gov/34726849/), Int J Oral Implantol (Berl).
- “An initial phase of non-surgical treatment achieves an improvement of the peri-implant clinical parameters, thought the method of debridement used seems not to influence. Key words:Peri-implantitis, peri-implant disease, non-surgical treatment, air-abrasive device, mechanical debridement.” — [Aloy-Prósper A et al. 2020](https://doi.org/10.4317/jced.56653), J Clin Exp Dent; cited 11.
- “The additional use of a titanium brush during regenerative treatment of peri-implantitis resulted in statistically significant benefits in terms of PPD reduction after 12 months.” — [de Tapia B et al. 2019](https://doi.org/10.1111/jcpe.13095), J Clin Periodontol; cited 118.
- “Modifying the contour of the prostheses to improve access for oral hygiene significantly improved the clinical outcomes after standard mechanical treatment of peri-implant mucositis.” — [de Tapia B et al. 2019](https://doi.org/10.1111/jcpe.13169), J Clin Periodontol; cited 92.

5 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

15 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Chitosan and titanium brushes are safe and effective tools for implant surface decontamination in peri-implant disease management but do not exhibit clear clinical superiority. The current evidence supports their use as adjunctive devices within standardized treatment protocols.” — [Pappolla Sessa C et al. 2025](https://doi.org/10.3390/jcm14238306), J Clin Med; cited 2.
- “Implant reosseointegration is possible following appropriate surface decontamination. Application of Er:YAG laser, electrolytic cleaning, and APA stand out as the methods that most closely embody the ideal characteristics of an effective decontamination protocol.” — [Ravidà A et al. 2025](https://pubmed.ncbi.nlm.nih.gov/40476898/), Int J Oral Maxillofac Implants.
- “Leave-one-out analysis confirmed the stability of the results. The findings highlight the need for future research with longer-term follow-up and high-quality, multi-center, large-sample RCTs.” — [Nengwen Huang et al. 2024](https://doi.org/10.1016/j.jdsr.2024.05.003), Japanese Dental Science Review; cited 18.
- “Available evidence on the efficacy of non-surgical submarginal peri-implant instrumentation with mechanical/physical decontamination is limited by the small number of controlled studies and the high heterogeneity of study protocols. Clinical and patient-reported benefits remain to be demonstrated.” — [Cosgarea R et al. 2023](https://doi.org/10.1111/jcpe.13762), J Clin Periodontol; cited 103.
- “Several mechanical/physical instrumentation procedures including curettes, ultrasonics, lasers, rotating brushes and air-polishing are documented; however, a beneficial effect over oral hygiene instructions alone or superiority over other procedures could not be demonstrated. Moreover, it remains unclear whether combinations of different procedures or their repetition over time may provide additional benefits.” — [Verket A et al. 2023](https://doi.org/10.1111/jcpe.13789), J Clin Periodontol; cited 62.
- “The standardized mean difference with a 95% confidence interval of the studied parameters was estimated using the random effect model; however, statistical differences were not detected between air polishing and comparative modalities in the treatment of peri-implantitis.” — [Bi J et al. 2023](https://doi.org/10.1563/aaid-joi-D-23-00114), J Oral Implantol; cited 7.

7 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

15 non-randomised clinical studies and 12 case reports or series.

- “Therapy reduced mucositis from 70% to 23%. Overall, while TNF-α levels alone may not conclusively differentiate between healthy and mucositis-affected sites in every context, they do appear to correlate with improvements in peri-implant health following therapeutic intervention.” — [Juliana Prazeres Gonçalves de Castro et al. 2025](https://doi.org/10.1590/0103-644020256205), Brazilian Dental Journal; cited 0.
- “The choice of decontamination method for the treatment of peri-implantitis should take into account the surface type and characteristics of the dental implant. The Er, Cr:YSGG laser proved to be a universal and effective method, while Air Flow and Vector Paro were more efficient when used for specific surface types.” — [Maksim V. Sokolov et al. 2025](https://doi.org/10.17116/rosstomat20251803126), Russian Journal of Stomatology; cited 0.
- “The obtained results underscore the necessity of selecting the surface treatment method according to the implant surface type to preserve its functional properties and ensure successful re-osseointegration.” — [Maksim V. Sokolov et al. 2025](https://doi.org/10.17116/rosstomat20251804132), Russian Journal of Stomatology; cited 0.
- “PDT as an adjunct to conventional peri-implantitis treatment with GBR resulted in statistically significantly lower PPD values. However, no additional benefits were observed for infection resolution, maintenance of infection-free status, MBL or BOP. Initial improvements in both groups followed by gradual recurrences in clinical parameters over 18 months.” — [Arısan V et al. 2025](https://doi.org/10.3290/j.ohpd.c_2078), Oral Health Prev Dent.
- “Thirty implants were enrolled and randomly assigned to test (GPAP) and control (ultrasonic device) groups. Significant differences were found in the mean of the clinical outcome evaluation but further observations of larger sample size of patients are needed.” — [Lucia Memè et al. 2024](https://doi.org/10.11138/oi16267-78), Oral & Implantology; cited 20.
- “: For the surgical treatment of peri-implantitis, reconstructive treatment involving mechanical debridement with ultrasonics and chemical decontamination, in addition to resolving peri-implant inflammation, allows for bone reconstruction around the implant. The use of multiple aids, both chemical and mechanical, for decontaminating the implant threads is key to achieving greater predictability in the procedure.” — [Giovanni Barbagallo et al. 2024](https://doi.org/10.29011/2575-9760.001984), Journal of Surgery; cited 2.

9 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

74 in vitro / ex vivo and 2 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “From this study, air polishing devices should be used with caution with titanium, PEEK, and zirconia; Prophy paste should be used with caution with titanium and lithium disilicate; and P5 scaler should be used with caution with zirconia. Further studies are required to study the clinical outcomes.” — [Pujarern P et al. 2026](https://doi.org/10.1055/s-0046-1818622), Eur J Dent; cited 1.
- “Ti ions and particles were found after instrumentation using SS curettes, Ti curettes, and CV ultrasonic inserts, which may affect the disease etiology and outcomes of peri-implantitis therapy more prominently compared to irradiation methods such as CS ultrasonic inserts, CO2 lasers, or ECY lasers.” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375), Int J Oral Maxillofac Implants; cited 1.
- “Er:YAG best preserved SLA microtopography but exhibited a lower debridement efficacy (3.27 ± 0.83) than mechanical methods. No method resulted in a pristine surface.” — [Yurdakul B et al. 2026](https://doi.org/10.3390/nano16120703), Nanomaterials (Basel); cited 1.
- “All mechanical instrumentation modalities altered titanium and zirconia surfaces to varying degrees. On titanium, EPAP was associated with a favourable combination of high cleaning efficacy and preserved native surface morphology. On zirconia, both air-polishing modalities achieved high cleaning efficacy with minimal topographical alteration.” — [Kamel MS et al. 2026](https://doi.org/10.1111/clr.70182), Clin Oral Implants Res; cited 0.
- “This difference was independent of defect type (p > 0.05). These findings indicate that electrochemical cleaning via galvanic current may be more effective, under in vitro conditions, for stain removal and surface decontamination; however, they also demonstrate that residual contamination could not be completely eliminated irrespective of the method.” — [Özay F et al. 2026](https://doi.org/10.3390/jfb17040166), J Funct Biomater; cited 0.
- “HIFU acoustic waves were uniquely able to penetrate a solid (glass) barrier and create localised biofilm-free regions. HIFU shows potential as a physical method for biofilm disruption; however, further studies - including multispecies, in vivo, and pre-clinical models - are required to evaluate its clinical applicability.” — [Tran MD et al. 2025](https://doi.org/10.1016/j.identj.2025.103905), Int Dent J; cited 4.

68 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “The results suggest that PDT and OFD have significant benefits in peri-implantitis treatment by reducing bacterial count. The presence of bacterial complex with different response to therapeutic modality suggests the use of combined decontamination methods for peri-implantitis treatment.” — [Madi M et al. 2018](https://doi.org/10.1155/2018/7570105), Biomed Res Int; cited 28.
- “Resolution of peri-implantitis after access surgery and decontamination of peri-implant surfaces with TiBrush(™) with or without sodium hypochlorite is possible. However, the concomitant use of sodium hypochlorite has minor effect on treatment outcomes.” — [Carral C et al. 2016](https://doi.org/10.1111/jcpe.12566), J Clin Periodontol; cited 42.


## Parameters as stated in the abstracts

- “Mechanical decontamination was performed for 120 s using either an OCB or a US-PEEK.” — [Khan SN et al. 2025](https://doi.org/10.1111/clr.14360) (in vitro).
- “Erythritol powder, PEEK ultrasonic tips, and titanium curettes were applied for 2 min in Class 1A defects and 3 minutes in Class 1B defects.” — [Ozgu I et al. 2025](https://doi.org/10.3791/67778) (in vitro).
- “All underwent clinical and radiographic exams and received non-invasive therapy (mechanical debridement, with ultrasonic scalers to remove calculus and sodium air-abrasive polishing to eliminate soft debris from the implant and prosthetic components + 0.12% chlorhexidine).” — [Juliana Prazeres Gonçalves de Castro et al. 2025](https://doi.org/10.1590/0103-644020256205) (clinical study).
- “The Er,Cr:YSGG laser irradiation with the 40 Hz group showed a significantly higher attached fibroblast cell numbers than the titanium scaler group at 72 h after treatment (p = 0.023).” — [Shiba T et al. 2024](https://doi.org/10.3390/ma17194899) (in vitro).
- “Decontamination of implant threads, was carried out using ultrasonic instruments and 24% EDTA.” — [Giovanni Barbagallo et al. 2024](https://doi.org/10.29011/2575-9760.001984) (clinical study).
- “Decontaminations were performed using titanium curette, stainless steel ultrasonic scaler (US), glycine (GPAP) and erythritol (EPAP) powder air-polishing, Er:YAG laser, 1% chlorhexidine (CHX), 10% povidone-iodine (PVI), 14% doxycycline (doxy), and 0.95% NaOCl solution.” — [Stein JM et al. 2023](https://doi.org/10.1111/clr.14014) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Piezon** — 9 entries
- **Air-Flow** — 5 entries
- **AIRFLOW** — 4 entries
- **Perisolv** — 3 entries
- **Waterlase** — 3 entries
- **Perio-Flow** — 2 entries
- **GalvoSurge** — 2 entries
- **Cavitron** — 2 entries
- **Vector** — 2 entries
- **PIEZON** — 1 entry
- **LightWalker** — 1 entry
- **AirFlow** — 1 entry
- **EMS Air-Flow** — 1 entry
- **TiBrush** — 1 entry

Manufacturers: EMS (17), Straumann (7), Geistlich (5), Biolase (4), Dentium (4), Hu-Friedy (4), Dentsply Sirona (3), Acteon (3), Fotona (3), Nobel Biocare (3), Dentsply (3), Satelec (3), Neobiotech (2), KaVo (2), Zimmer Biomet (2), Sirona (2), Zimmer (2), Astra Tech (1), Thommen (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (19 different): chlorhexidine (34), saline (25), hydrogen peroxide (19), antibiotics (systemic) (11), citric acid (11), tetracycline (9), amoxicillin (7), photosensitizer dye (7), sodium hypochlorite (7), sterile water (6), minocycline (5), metronidazole (4), doxycycline (4), Perisolv (3), EDTA (3), chloramine (2), enamel matrix derivative (2), povidone-iodine (2), phosphoric acid / etching gel (2). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (148)

The 148 entries of this chapter are listed in the table on the web page (https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/#entries), in the searchable table of all entries (https://www.nitibrush.com/articles/literature-index/all-entries/) and in the CSV/JSON data.


## Related chapters

- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [5. Lasers](https://www.nitibrush.com/articles/literature-index/laser/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [7. Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/)
- Next: [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)