# 5. Lasers

Chapter 5 of an evidence-based reader on implant surface decontamination in peri-implantitis: 283 entries on lasers — what the randomised trials, systematic reviews and laboratory studies concluded, in the authors' own words, with products named as written. Not a ranking.

URL: https://www.nitibrush.com/articles/literature-index/laser/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

What does the literature report about laser decontamination of the implant surface (Er:YAG, Er,Cr:YSGG, diode, CO₂, Nd:YAG)?

**Key facts — Lasers**

- Entries in this chapter: 283 of 819 (2000–2026): RCT 25 · clinical study 34 · case report/series 18 · systematic review 40 · review 28 · in vitro 102 · animal study 11 · not classified 25
- Most cited: [Smeets R et al. 2014](https://doi.org/10.1186/1746-160X-10-34) (590); [Aoki A et al. 2015](https://doi.org/10.1111/prd.12080) (457); [Frank Schwarz et al. 2011](https://doi.org/10.1111/j.1600-051x.2010.01690.x) (294)
- Products named by the authors: Waterlase (6), Air-Flow (6), LightWalker (3), Piezon (3), GalvoSurge (2), Cavitron (2), TiBrush (2), Perisolv (2), Perio-Flow (1), Ti-Brush (1)
- Manufacturers named by the authors: Straumann (16), Biolase (11), EMS (7), Fotona (7), Geistlich (6), Dentsply Sirona (5), Hu-Friedy (5), Nobel Biocare (4), Dentsply (4), Sirona (4)
- Chemical agents used alongside: chlorhexidine (47), saline (41), photosensitizer dye (28), hydrogen peroxide (22), antibiotics (systemic) (18), amoxicillin (15), sterile water (13), citric acid (10)
- Often studied together with: [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) (77), [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) (61), [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) (59), [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) (54)
- Entries naming the NiTi Brush: 1 — see [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/)


## What it is

Laser light of a given wavelength applied to the implant surface to remove or inactivate biofilm, alone or after mechanical debridement. The wavelengths reported are erbium (Er:YAG, Er,Cr:YSGG), diode (various wavelengths), carbon dioxide and neodymium (Nd:YAG); power, pulse energy, frequency, water spray and exposure time vary widely and are quoted as stated.


### Mechanism and use, as the papers describe it

The publications in this chapter describe laser light directed at the implant surface from neodymium (Nd:YAG), carbon dioxide (CO2), diode, erbium (Er:YAG) and erbium-chromium (Er,Cr:YSGG) devices.[1] The wavelengths named are Nd:YAG at 1,064 nm, Er,Cr:YSGG at 2,780 nm, Er:YAG at 2,940 nm, CO2 at 9,300 nm and 10,600 nm, diodes at 445 nm and from 808 nm to 980 nm, and a 308 nm excimer laser in one laboratory study.[2,3,4,5,6,7,8] The effects ascribed to the light are a reduction of bacteria on the implant surface and surrounding tissues together with cutting and coagulation.[9] Erbium wavelengths are described as removing calculus and calcified deposits from the titanium microstructure and, at higher fluence, as stripping the contaminated oxide layer.[10,11,12,13] Low-energy Nd:YAG and 808 nm diode irradiation were also reported to attenuate the response of cultured cells to lipopolysaccharide adherent to titanium.[14,4]

In the clinical entries the laser is applied into the pocket during non-surgical treatment or onto the exposed surface after flap elevation.[15,16] Non-surgical use is described for mucositis and peri-implantitis with diode, Er:YAG and Er,Cr:YSGG devices, usually in the same session as mechanical debridement, and in one trial as repeated diode applications on days 0, 7 and 14.[5,17,18,19] Surgical use is described for Er:YAG on the intrabony surface after implantoplasty, for Er:YAG and Er,Cr:YSGG before grafting, for CO2 before augmentation, and for a combined Nd:YAG and Er:YAG approach.[20,21,22,23,24] Delivery is reported in contact or non-contact mode through fibres, sapphire or quartz tips and conical, end-firing or side-firing tips, with or without an air-water spray.[25,26,27,28]


### Reported operating conditions

Er:YAG pulse energies in the abstracts range from 30 mJ to 320 mJ at 10 Hz to 30 Hz, with 100 mJ at 10 Hz used on implants before explantation, 30 mJ to 50 mJ at 30 Hz with water spray for microstructured surfaces, and 60 mJ and 80 mJ groups in one clinical trial.[10,29,30,31] Energy densities are quoted as 3.76 J/cm2 to 14.2 J/cm2 per pulse and 20.3 J/cm2 or 38.2 J/cm2 in non-contact mode, with pulse durations of 50 µs to 600 µs, exposure of 1 to 2 minutes, and one protocol specifying an 8 mm sapphire tip, air 6 and water 4 at 2 mm/s.[32,11,13,33,34] Er,Cr:YSGG settings are given as 1.5 W, 30 Hz and 50 mJ with 40 to 50 per cent air and water, 0.75 W at 100 Hz, 2.5 W at 30 Hz for 30 s, and 0.5 W to 2 W at 20 Hz under irrigation.[22,35,28,36,37]

Diode parameters span 810 nm at 1.0 W pulsed and 3 J/cm2 for 1 minute, 970 nm at 1.2 W continuous wave, 808 nm at 2 W continuous wave or pulsed at 20 kHz through a 600 µm fibre for 1 minute, and 810 nm at an average of 3.84 W for two or three 15 s repetitions.[5,6,4,38] Laboratory series tested 1 W to 15 W, while 445 nm protocols used 0.5 W pulsed or 2 W to 3 W continuous wave at 1 mm distance and 0.8 W to 3 W at duty cycles of 10 to 100 per cent for 5 s to 20 s.[39,40,41,42,43] CO2 settings include superpulsed 7 W at 80 Hz on a wet surface, pulsed non-contact 1 W to 5 W, continuous-wave 2 W defocused, and a 9.3 µm device at 13.9 W with mist for one minute.[44,45,46,47] Nd:YAG was applied at 1 W to 6 W with 50 mJ to 350 mJ in contact, and in Q-switched mode at 0.597 J/cm2 per pulse with 6 ns pulses for 2 s at 0.5 mm from the surface.[45,41,48,49]


### Effects on the implant surface reported in laboratory studies

Scanning electron microscopy showed extensive melting after conventional Nd:YAG irradiation at 2 W to 6 W, damage proportional to power, and no change with a 980 nm diode at 5 W to 15 W or CO2 at 1 W or 2 W, whereas CO2 at 3.5 W to 5 W destroyed micromachined grooves.[41,45] A five-wavelength comparison found no to minimal alteration with Er,Cr:YSGG and Er:YAG, more evident alteration with Nd:YAG and diode at high power, and the most prominent damage with Nd:YAG.[50] Diode melting or flattening was reported at 4.5 W to 5.5 W and at 2 W to 3 W with 940 nm.[40,39] For erbium lasers, reduced ridge sharpness at 140 mJ to 180 mJ, cracks and melting at 100 mJ or 200 mJ, a 0.25 µm smoother surface and ready damage of anodised surfaces are described alongside reports of unchanged roughness.[34,51,52,29,53] Conical tips produced no surface effect at any setting, effects with conventional optics were dose related, and water reduced the influence of irradiation.[26] Titanium ions were not detected after CO2 or Er,Cr:YSGG irradiation.[46]

Er:YAG at 60 mJ to 120 mJ kept the implant-bone interface below 47 °C over 120 s, rises stayed below 10 °C with and without spray in another model, and contact Er:YAG produced a focal rise to 58 °C in a biofilm study.[54,55,56] Diodes at 2 W continuous wave reached a 10 °C rise within 12 s to 14 s, a 445 nm diode exceeded 10 °C at 0.8 W continuous wave for 5 s, and a 940 nm diode reached 185 °C on an RBM surface at 3 W pulsed for 60 s, while rises stayed below 10 °C up to 1 W in porcine ribs.[57,3,58,59] Residual biofilm after Er:YAG is reported as 32.8 per cent of disc area against 74.0 per cent untreated, and as a lower debridement index than mechanical methods on explanted implants, with no method leaving a pristine surface.[60,61] Cell studies report osteoblast attachment on Er:YAG-treated discs, higher fibroblast and osteoblast counts after Er:YAG or Er,Cr:YSGG than on untreated contaminated surfaces, preserved biocompatibility after 808 nm diode treatment, fewer spreading cells after CO2 at 6 W or 8 W, and a cellular response that remained below that of pristine implants.[13,62,63,64,65,66,67]


### Position in treatment protocols

In non-surgical trials the laser is an adjunct to instrumentation with curettes, ultrasonic devices or air-polishing, and in a few trials the sole decontamination measure.[15,17,19] A 2014 meta-analysis reported a weighted mean difference of 0.00 mm in probing depth reduction between laser and conventional non-surgical treatment, and a 2023 systematic review found significant probing depth reductions over control only in an Er,Cr:YSGG group at 6 months.[68,15] A 2024 meta-analysis concluded that solid-state lasers improved probing depth, bleeding and attachment level while diode lasers provided no additional effect, and diode-only meta-analyses reported no advantage over mechanical debridement alone.[69,70,71] Two randomised trials comparing non-surgical diode treatment with flap surgery reported greater pocket reduction after surgery and described the laser as a less invasive option for non-advanced defects.[19,6]

In surgical protocols the laser decontaminates the exposed surface after granulation tissue removal, with or without implantoplasty, before resective or augmentative measures.[20,72] Schwarz et al. reported that Er:YAG and plastic curettes with saline gave comparable outcomes of combined surgery at 6 months, 4 years and 7 years.[20,73,74] A 2022 meta-analysis found a lack of added effect of Er:YAG on probing depth reduction, and a 2023 review of five trials judged the evidence inconclusive.[75,76] Individual trials reported higher probing depth reduction with adjunctive Er:YAG in regenerative therapy and greater reduction in bleeding sites with combined Nd:YAG and Er:YAG, while adjunctive diode laser showed no long-term effect in non-regenerative surgery.[21,24,77] Animal studies describe new bone on Er:YAG-treated surfaces and no apparent effect of CO2 with hydrogen peroxide on re-osseointegration.[78,79,80]


### Limitations and open questions as stated by the authors

Review authors cite small samples, short follow-up and heterogeneous protocols as reasons why no firm conclusion can be drawn, and one attributes inconclusive surgical findings to non-uniform control groups and laser parameters.[1,15,76] Adjunctive benefit is described as limited to the short term, radiographic outcomes were reported without consistent statistical significance, and microbiological evidence was graded very low in certainty.[81,82,83,84] Laboratory reviews concluded that no universally safe tool for surface integrity could be identified and that laser parameters, implant material and geometry govern the temperature response.[85,3] Authors also call for trials using the 2018 classification and for uniform protocols with longer follow-up.[86,87,88]


### Sources cited in this description (88)

1. Natto ZS et al. (2015). Comparison of the efficacy of different types of lasers for the treatment of peri-implantitis: a systematic review. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.3846 · systematic review
2. Linden E et al. (2021). SEM Evaluation of the Effects of Laser-Mediated Implant Surface Decontamination: An In Situ Human Pilot Study. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.4911 · in vitro
3. Herbert Deppe et al. (2021). Thermal effect of a 445 nm diode laser on five dental implant systems: an in vitro study *Scientific Reports*. https://doi.org/10.1038/s41598-021-99709-8 · in vitro
4. Giannelli M et al. (2016). The effects of diode laser on Staphylococcus aureus biofilm and Escherichia coli lipopolysaccharide adherent to titanium oxide surface of dental implants. An in vitro study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-016-2025-5 · in vitro
5. Volkan Arısan et al. (2015). A Randomized Clinical Trial of an Adjunct Diode Laser Application for the Nonsurgical Treatment of Peri-Implantitis *Photomedicine and Laser Surgery*. https://doi.org/10.1089/pho.2015.3956 · RCT
6. Malmqvist S et al. (2025). Treatment of peri-implantitis with diode laser or mucosal flap surgery: A clinical randomized controlled trial. *J Periodontol*. https://doi.org/10.1002/JPER.24-0683 · RCT
7. Giulia Maria Mariani et al. (2020). One-year clinical outcomes following non-surgical treatment of peri-implant mucositis with adjunctive diode laser application *Minerva Dental and Oral Science*. https://doi.org/10.23736/s0026-4970.20.04340-x · clinical study
8. Deppe H et al. (2007). Effect of 308-nm excimer laser light on peri-implantitis-associated bacteria: an in vitro investigation. *Lasers Med Sci*. https://doi.org/10.1007/s10103-007-0441-2 · in vitro
9. Romanos GE et al. (2009). Laser wavelengths and oral implantology. *Lasers Med Sci*. https://doi.org/10.1007/s10103-009-0676-1 · review
10. Schwarz F et al. (2003). \[Influence of an Er:YAG laser on the surface structure of titanium implants\]. *Schweiz Monatsschr Zahnmed*. https://pubmed.ncbi.nlm.nih.gov/12872590/ · clinical study
11. Takagi T et al. (2018). Effective removal of calcified deposits on microstructured titanium fixture surfaces of dental implants with erbium lasers. *J Periodontol*. https://doi.org/10.1002/JPER.17-0389 · in vitro
12. Yamamoto A et al. (2013). Treatment of peri-implantitis around TiUnite-surface implants using Er:YAG laser microexplosions. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.1593 · animal study
13. Giannelli M et al. (2017). Effects of an Erbium:Yttrium-Aluminum-Garnet Laser and Ultrasonic Scaler on Titanium Dioxide-Coated Titanium Surfaces Contaminated With Subgingival Plaque: An In Vitro Study to Assess Post-Treatment Biocompatibility With Osteogenic Cells. *J Periodontol*. https://doi.org/10.1902/jop.2017.170195 · clinical study
14. Giannelli M et al. (2009). In vitro evaluation of the effects of low-intensity Nd:YAG laser irradiation on the inflammatory reaction elicited by bacterial lipopolysaccharide adherent to titanium dental implants. *J Periodontol*. https://doi.org/10.1902/jop.2009.080648 · in vitro
15. Cosgarea R et al. (2023). Efficacy of mechanical/physical approaches for implant surface decontamination in non-surgical submarginal instrumentation of peri-implantitis. A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13762 · systematic review
16. Ramanauskaite A et al. (2023). Photo/mechanical and physical implant surface decontamination approaches in conjunction with surgical peri-implantitis treatment: A systematic review. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.13783 · systematic review
17. Viveca Wallin Bengtsson et al. (2025). Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-025-00591-0 · RCT
18. Clementini M et al. (2026). Evaluation of the Adjunctive Use of Er:YAG Laser or Erythritol Air-Polishing in the Non-Surgical Treatment of Peri-Implantitis: A Pilot RCT. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70153 · RCT
19. Dena Hashim et al. (2025). A randomised clinical trial comparing a surgical approach for treatment of peri-implantitis to non-surgical debridement with adjunctive diode laser therapy *Clinical Oral Investigations*. https://doi.org/10.1007/s00784-025-06204-9 · RCT
20. Frank Schwarz et al. (2011). Impact of the method of surface debridement and decontamination on the clinical outcome following combined surgical therapy of peri-implantitis: a randomized controlled clinical study *Journal Of Clinical Periodontology*. https://doi.org/10.1111/j.1600-051x.2010.01690.x · RCT
21. Wang CW et al. (2021). Laser-assisted regenerative surgical therapy for peri-implantitis: A randomized controlled clinical trial. *J Periodontol*. https://doi.org/10.1002/JPER.20-0040 · RCT
22. Nevins M et al. (2020). Human Histologic Evaluations of the Use of Er,Cr:YSGG Laser to Decontaminate an Infected Dental Implant Surface in Preparation for Implant Reosseointegration. *Int J Periodontics Restorative Dent*. https://doi.org/10.11607/prd.5139 · clinical study
23. Romanos GE et al. (2008). Regenerative therapy of deep peri-implant infrabony defects after CO2 laser implant surface decontamination. *Int J Periodontics Restorative Dent*. https://pubmed.ncbi.nlm.nih.gov/18605600/ · clinical study
24. Fragkioudakis I et al. (2023). Surgical Treatment of Peri-Implantitis Using a Combined Nd: YAG and Er: YAG Laser Approach: Investigation of Clinical and Bone Loss Biomarkers. *Dent J (Basel)*. https://doi.org/10.3390/dj11030061 · clinical study
25. Chegeni E et al. (2020). Effect of an Er,Cr:YSGG Laser on the Surface of Implants: A Descriptive Comparative Study of 3 Different Tips and Pulse Energies. *Dent J (Basel)*. https://doi.org/10.3390/dj8040109 · in vitro
26. Thomas Fenelon et al. (2020). Effects of Lasers and Their Delivery Characteristics on Machined and Micro-Roughened Titanium Dental Implant Surfaces *Bioengineering*. https://doi.org/10.3390/bioengineering7030093 · in vitro
27. Walinski CJ et al. (2020). Resin cement removal from titanium dental implant surface using a novel side-firing laser fiber and Er,Cr:YSGG irradiation. *Am J Dent*. https://pubmed.ncbi.nlm.nih.gov/32794390/ · in vitro
28. Kottmann L et al. (2023). Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study. *Int J Implant Dent*. https://doi.org/10.1186/s40729-023-00469-z · in vitro
29. Taniguchi Y et al. (2013). Optimal Er:YAG laser irradiation parameters for debridement of microstructured fixture surfaces of titanium dental implants. *Lasers Med Sci*. https://doi.org/10.1007/s10103-012-1171-7 · in vitro
30. Sobierajska P et al. (2026). The Effect of the Er3+:YAG Laser Decontamination Process on the Surface of Titanium Alloys, Depending on the Exposure Parameters. *Materials (Basel)*. https://doi.org/10.3390/ma19040775 · in vitro
31. Xiaoying Dai et al. (2025). Evaluation of the therapeutic effects of Er:YAG laser with different parameters on peri-implantitis *Medicine*. https://doi.org/10.1097/md.0000000000044061 · RCT
32. Nejem Wakim R et al. (2018). Decontamination of Dental Implant Surfaces by the Er:YAG Laser Beam: A Comparative in Vitro Study of Various Protocols. *Dent J (Basel)*. https://doi.org/10.3390/dj6040066 · in vitro
33. Secgin-Atar A et al. (2021). Evaluation of Surface Change and Roughness in Implants Lost Due to Peri-Implantitis Using Erbium Laser and Various Methods: An In Vitro Study. *Nanomaterials (Basel)*. https://doi.org/10.3390/nano11102602 · in vitro
34. Kim JH et al. (2011). The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2011.41.5.234 · in vitro
35. Hashim A et al. (2024). Comparison of the efficacy of Er,Cr:YSGG laser on oral biofilm removal from implant surfaces with various application times for the treatment of peri-implantitis defects: ex vivo study. *BMC Oral Health*. https://doi.org/10.1186/s12903-024-04698-5 · RCT
36. Chedid C et al. (2026). Comparative Efficacy of Er,Cr:YSGG Laser, Electrolytic Cleaning, and Chlorhexidine for the Decontamination of Sandblasted, Large-Grit, Acid-Etched (SLA) Implant Surfaces: An In Vitro Controlled Study. *Cureus*. https://doi.org/10.7759/cureus.113294 · in vitro
37. Lin CJ et al. (2022). The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study. *J Funct Biomater*. https://doi.org/10.3390/jfb13030133 · in vitro
38. Wawrzyk A et al. (2022). Analysis of the Microbiome on the Surface of Corroded Titanium Dental Implants in Patients with Periimplantitis and Diode Laser Irradiation as an Aid in the Implant Prosthetic Treatment: An Ex Vivo Study. *Materials (Basel)*. https://doi.org/10.3390/ma15175890 · clinical study
39. Mostafa Ahmed Rezeka et al. (2024). Evaluation of the effect of diode laser application on the hydrophilicity, surface topography, and chemical composition of titanium dental implant surface *Journal of Prosthodontics*. https://doi.org/10.1111/jopr.13823 · in vitro
40. Faramarzi M et al. (2018). Evaluation of surface changes of dental implants after irradiation with diode laser beams with different energies: A SEM study. *J Adv Periodontol Implant Dent*. https://doi.org/10.15171/japid.2018.013 · in vitro
41. Romanos GE et al. (2000). Effects of diode and Nd:YAG laser irradiation on titanium discs: a scanning electron microscope examination. *J Periodontol*. https://doi.org/10.1902/jop.2000.71.5.810 · in vitro
42. Pergolini D et al. (2023). SEM Evaluation of Thermal Effects Produced by a 445 nm Laser on Implant Surfaces. *Dent J (Basel)*. https://doi.org/10.3390/dj11060148 · in vitro
43. Ahrens M et al. (2024). Bacterial reduction and temperature increase of titanium dental implant models treated with a 445 nm diode laser: an in vitro study. *Sci Rep*. https://doi.org/10.1038/s41598-024-68780-2 · in vitro
44. Mouhyi J et al. (2000). Re-establishment of the atomic composition and the oxide structure of contaminated titanium surfaces by means of carbon dioxide laser and hydrogen peroxide: an in vitro study. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/j.1708-8208.2000.tb00117.x · clinical study
45. Park CY et al. (2005). Surface properties of endosseous dental implants after NdYAG and CO2 laser treatment at various energies. *J Oral Maxillofac Surg*. https://doi.org/10.1016/j.joms.2005.06.015 · in vitro
46. Romanos GE et al. (2026). Spectrometric Analysis of Titanium Particle Release Based on Various Implant Surface Detoxification Methods. *Int J Oral Maxillofac Implants*. https://doi.org/10.11607/jomi.11375 · in vitro
47. Scott H. Froum et al. (2025). Periimplantitis Surface Decontamination and Integrity Following Use of Co2 Laser or Water Irrigation and Mechanical Therapy: A Comparison Study **. https://doi.org/10.61440/jsdr.2025.v3.26 · in vitro
48. Namour M et al. (2019). Q-Switch Nd:YAG Laser-Assisted Decontamination of Implant Surface. *Dent J (Basel)*. https://doi.org/10.3390/dj7040099 · in vitro
49. Namour M et al. (2021). Assessment of Disinfection Potential of Q-Switch Nd: YAG Laser on Contaminated Titanium Implant Surfaces. *Materials (Basel)*. https://doi.org/10.3390/ma14206078 · in vitro
50. Sedrak PA et al. (2025). Effect of different wavelengths and powers of laser on surface topography and biofilm removal from titanium implants: an in vitro study. *BMC Oral Health*. https://doi.org/10.1186/s12903-025-07212-7 · in vitro
51. Matys J et al. (2019). Temperature Changes and SEM Effects of Three Different Implants-Abutment Connection during Debridement with Er:YAG Laser: An Ex Vivo Study. *Materials (Basel)*. https://doi.org/10.3390/ma12223748 · in vitro
52. Yao WL et al. (2020). Er,Cr:YSGG Laser Performance Improves Biological Response on Titanium Surfaces. *Materials (Basel)*. https://doi.org/10.3390/ma13030756 · in vitro
53. Assery N et al. (2023). The effect of Er:YAG laser treatment on biofilm formation on titanium and zirconia disc surfaces. *J Periodontol*. https://doi.org/10.1002/JPER.22-0243 · in vitro
54. Kreisler M et al. (2002). Temperature changes at the implant-bone interface during simulated surface decontamination with an Er:YAG laser. *Int J Prosthodont*. https://pubmed.ncbi.nlm.nih.gov/12475166/ · animal study
55. Monzavi A et al. (2014). Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems. *J Dent (Tehran)*. https://pubmed.ncbi.nlm.nih.gov/24910697/ · animal study
56. Ulu M et al. (2018). Antibiofilm efficacies of cold plasma and er: YAG laser on Staphylococcus aureus biofilm on titanium for nonsurgical treatment of peri-implantitis. *Niger J Clin Pract*. https://doi.org/10.4103/njcp.njcp_261_17 · in vitro
57. Geminiani A et al. (2012). Temperature change during non-contact diode laser irradiation of implant surfaces. *Lasers Med Sci*. https://doi.org/10.1007/s10103-010-0876-8 · in vitro
58. Sarac Atagun O et al. (2025). Effects of diode laser parameters on thermal response of RBM, SLA, and additively manufactured titanium surfaces. *Lasers Med Sci*. https://doi.org/10.1007/s10103-025-04759-3 · in vitro
59. Matys J et al. (2016). Thermodynamic effects after Diode and Er:YAG laser irradiation of grade IV and V titanium implants placed in bone - an ex vivo study. Preliminary report. *Biomed Tech (Berl)*. https://doi.org/10.1515/bmt-2015-0135 · in vitro
60. AlMoharib HS et al. (2021). Efficacy of an Er:YAG laser in the decontamination of dental implant surfaces: An in vitro study. *J Periodontol*. https://doi.org/10.1002/JPER.20-0765 · RCT
61. Yurdakul B et al. (2026). Mechanical Versus Laser Debridement of SLA Titanium Implants: An In Vitro Morphological and Elemental Analysis of Debris Removal and Surface Preservation. *Nanomaterials (Basel)*. https://doi.org/10.3390/nano16120703 · in vitro
62. Eick S et al. (2017). In Vitro-Activity of Er:YAG Laser in Comparison with other Treatment Modalities on Biofilm Ablation from Implant and Tooth Surfaces. *PLoS One*. https://doi.org/10.1371/journal.pone.0171086 · in vitro
63. Shiba T et al. (2024). Effect of Er,Cr:YSGG Laser Irradiation on the Surface Modification and Cell Adhesion on Titanium Discs: An In Vitro Study. *Materials (Basel)*. https://doi.org/10.3390/ma17194899 · in vitro
64. Chellini F et al. (2017). Mesenchymal stromal cell and osteoblast responses to oxidized titanium surfaces pre-treated with λ = 808 nm GaAlAs diode laser or chlorhexidine: in vitro study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-017-2243-5 · in vitro
65. Ayubianmarkazi N et al. (2015). An in vitro evaluation of the responses of human osteoblast-like SaOs-2 cells on SLA titanium surfaces irradiated by different powers of CO2 lasers. *Lasers Med Sci*. https://doi.org/10.1007/s10103-015-1756-z · in vitro
66. Hashim A et al. (2026). Influence of peri-implantitis defect angles on morphology and the biocompatibility of the implant surfaces after Er, Cr: YSGG laser therapy: an ex vivo study. *BMC Oral Health*. https://doi.org/10.1186/s12903-026-09278-3 · clinical study
67. Jin SH et al. (2019). Decontamination methods to restore the biocompatibility of contaminated titanium surfaces. *J Periodontal Implant Sci*. https://doi.org/10.5051/jpis.2019.49.3.193 · in vitro
68. Mailoa J et al. (2014). Clinical outcomes of using lasers for peri-implantitis surface detoxification: a systematic review and meta-analysis. *J Periodontol*. https://doi.org/10.1902/jop.2014.130620 · systematic review
69. Nengwen Huang et al. (2024). The clinical efficacy of laser in the nonsurgical treatment of peri-implantitis: a systematic review and meta-analysis *International Journal of Implant Dentistry*. https://doi.org/10.1186/s40729-024-00570-x · systematic review
70. Amit Kumar et al. (2026). Efficacy of Diode Lasers in Non-surgical Management of Peri-Implantitis: A Systematic Review and Meta-analysis *Asian Journal of Oral Health and Allied Sciences*. https://doi.org/10.18231/j.ajohas.32321.1791449240 · systematic review
71. Momen A. Atieh et al. (2022). Diode Laser as an Adjunctive Treatment for Peri-implant Mucositis: A Systematic Review and Meta-analysis *International Dental Journal*. https://doi.org/10.1016/j.identj.2022.06.026 · systematic review
72. Noelken R et al. (2020). A modified surgical approach for hard and soft tissue reconstruction of severe periimplantitis defects: laser-assisted periimplant defect regeneration (LAPIDER). *Int J Implant Dent*. https://doi.org/10.1186/s40729-020-00218-6 · clinical study
73. Schwarz F et al. (2013). Four-year follow-up of combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12143 · RCT
74. Schwarz F et al. (2017). Combined surgical therapy of advanced peri-implantitis evaluating two methods of surface decontamination: a 7-year follow-up observation. *J Clin Periodontol*. https://doi.org/10.1111/jcpe.12648 · RCT
75. Baima G et al. (2022). Surface decontamination protocols for surgical treatment of peri-implantitis: A systematic review with meta-analysis. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.13992 · systematic review
76. Lei Li et al. (2023). Efficacy of Er:YAG Laser as a Debridement Method in Surgical Treatment for Peri-Implantitis: A Systematic Review. *PubMed Central*. https://doi.org/10.3290/j.ohpd.b3818041 · systematic review
77. Philip Leander Keeve et al. (2018). Surgical Treatment of Periimplantitis With Non–Augmentative Techniques *Implant Dentistry*. https://doi.org/10.1097/id.0000000000000838 · clinical study
78. Takasaki AA et al. (2007). Er:YAG laser therapy for peri-implant infection: a histological study. *Lasers Med Sci*. https://doi.org/10.1007/s10103-006-0430-x · animal study
79. Persson LG et al. (2004). Carbon dioxide laser and hydrogen peroxide conditioning in the treatment of periimplantitis: an experimental study in the dog. *Clin Implant Dent Relat Res*. https://doi.org/10.1111/j.1708-8208.2004.tb00039.x · in vitro
80. Patil S et al. (2023). Efficacy of laser in re-osseointegration of dental implants-a systematic review. *Lasers Med Sci*. https://doi.org/10.1007/s10103-023-03860-9 · systematic review
81. Marianna Chala et al. (2020). Adjunctive Use of Lasers in Peri-Implant Mucositis and Peri-Implantitis Treatment: A Systematic Review *Dentistry Journal*. https://doi.org/10.3390/dj8030068 · systematic review
82. Miriam Ting et al. (2022). Laser Treatment of Peri-Implantitis: A Systematic Review of Radiographic Outcomes *Dentistry Journal*. https://doi.org/10.3390/dj10020020 · systematic review
83. Zhe Wang et al. (2026). Comparative effectiveness of novel laser-assisted technologies for treating peri-implantitis: A network meta-analysis of randomized controlled trials *Medicine*. https://doi.org/10.1097/md.0000000000051256 · systematic review
84. Neophytou C et al. (2026). Microbiological Effects of Laser-Assisted Non-Surgical Treatment of Peri-Implantitis: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. *Dent J (Basel)*. https://doi.org/10.3390/dj14010049 · systematic review
85. Valeriani L et al. (2026). Impact of Biofilm Decontamination Methods on Implant-Abutment Surface Integrity: A Systematic Review of Quantitative Studies. *Clin Oral Implants Res*. https://doi.org/10.1111/clr.70077 · systematic review
86. Amna Mohamed Abdulla AlMarzooqi et al. (2023). Treatment of Peri-implant Diseases using Lasers: A Systematic Review *The Open Dentistry Journal*. https://doi.org/10.2174/18742106-v17-e230517-2022-143 · systematic review
87. Glaucia Valias Filgueiras et al. (2026). Laser Therapy in the Prevention and Treatment of Peri-Implantitis: A Critical Integrative Review *Revista Multidisciplinar do Nordeste Mineiro*. https://doi.org/10.66104/e25tcs21 · review
88. \*Dr. Shrirup Jogdand, Dr. Roshani Thakur, Dr. Motilal Jangid, Dr. Sakshi Jaiswal, Dr. Vaishnavi Dighe, Dr.Kalpana Jangid (2026). LASERS IN THE MANAGEMENT AND PREVENTION OF PERI-IMPLANTITIS: A NARRATIVE REVIEW OF CURRENT EVIDENCE AND FUTURE DIRECTIONS *Zenodo (CERN European Organization for Nuclear Research)*. https://doi.org/10.5281/zenodo.21021706 · review

*The description above was written by HANS Korea from the abstracts of the cited publications; each statement carries its sources. Everything below the sources list is generated from the published records on each refresh.*


## What the randomised clinical trials concluded

25 randomised trials in this chapter. Each sentence is the authors' own conclusion, quoted from the abstract; the method of this chapter may be the test arm, the control arm or one step common to all arms — read the paper before transferring a result to any instrument.

- “Irrespective of the adjunctive treatment modality, achievement of peri-implantitis therapeutic endpoint was limited across groups. Possible associations with treatment outcomes were observed; these findings require confirmation in larger studies.” — [Clementini M et al. 2026](https://doi.org/10.1111/clr.70153), Clin Oral Implants Res; cited 2.
- “SOP positivity (12.5% vs. 6.58%, P = 0.191) and implant survival (98.08% vs. 100%, P = 0.509) did not differ significantly between groups. Conclusion Adjunctive ECL therapy may improve clinical parameters, reduced bacterial load, and slowed marginal bone loss compared to MD alone in patients with peri-implantitis at 6-month follow-up, but further prospective studies are necessary to validate these findings and …” — [Jiaojie Li et al. 2026](https://doi.org/10.1016/j.jrras.2026.102723), Journal of Radiation Research and Applied Sciences; cited 0.
- “The study concluded that Mechanical debridement combined with photodynamic therapy (MD + PDT) improves peri-implant health and reduces inflammation significantly better than mechanical debridement alone.” — [Pallavi Goswami 2026](https://doi.org/10.5281/zenodo.23053610), Journal of chemical health risks; cited 0.
- “Surgical approaches for management of peri-implantitis demonstrated significant benefits over laser therapy in terms of treatment success and PD reduction. Nevertheless, diode laser therapy, as described in this study, could represent a minimally invasive alternative for treatment of non-advanced peri-implantitis defects.” — [Dena Hashim et al. 2025](https://doi.org/10.1007/s00784-025-06204-9), Clinical Oral Investigations; cited 12.
- “Within the limitations of this feasibility study, the present data concluded that plasma spray and Erbium: YAG laser can be used for abutment surface treatment to achieve better peri-implant soft tissue healing.” — [Yossri D et al. 2025](https://doi.org/10.1111/cid.13373), Clin Implant Dent Relat Res; cited 7.
- “Treatment of peri-implant mucositis was effective regardless of whether the treatment was performed with an Er:YAG laser or an ultrasonic scaler. Fewer diseased sites were diagnosed at six months following laser treatment. TRIAL REGISTRATION: Registered at www. CLINICALTRIALS: gov : study no, NCT05772299.” — [Viveca Wallin Bengtsson et al. 2025](https://doi.org/10.1186/s40729-025-00591-0), International Journal of Implant Dentistry; cited 6.
- “Er:YAG laser therapy, particularly at higher energy levels (80 mJ), enhances clinical outcomes in peri-implantitis treatment by effectively reducing plaque biofilm, inflammation, and pain. These findings underscore the importance of optimizing laser energy parameters for improved peri-implantitis management.” — [Xiaoying Dai et al. 2025](https://doi.org/10.1097/md.0000000000044061), Medicine; cited 5.
- “Clinical parameters were measured before and after treatment at baseline, 1 month, 3 months and 6 months. Both DLAD and PDT are effective in treating peri-implant mucositis around platform-switch implants, with no significant difference in clinical outcomes.” — [Randhir Kumar et al. 2025](https://doi.org/10.6026/973206300211103), Bioinformation; cited 1.
- “The proportion of patients with improved clinical outcomes was similar between the 2 treatment groups, albeit surgical treatment yielded greater pocket reduction. No differences were found in immunological or microbial outcomes.” — [Malmqvist S et al. 2025](https://doi.org/10.1002/JPER.24-0683), J Periodontol.
- “Diode laser seems to be a reliable tool as an adjunct for supporting the nonsurgical mechanical treatment during the early stages of peri-implantitis. Furthermore, the findings suggest that IL-17, sclerostin and IL-1β may serve as promising biomarkers for assessing efficacy of peri-implantitis treatment.” — [Nazan Ece Erduran et al. 2024](https://doi.org/10.1007/s00784-024-05855-4), Clinical Oral Investigations; cited 10.

15 further RCT entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## What the systematic reviews and meta-analyses concluded

40 systematic reviews or meta-analyses mention this method; most cover several methods at once (the [synthesis chapter](https://www.nitibrush.com/articles/literature-index/synthesis/) lists all of them).

- “Laser-assisted therapies, especially PDT, may provide targeted microbiological benefit in selected patient groups, supporting their adjunctive use within personalized treatment planning rather than as replacements for mechanical debridement, which remains the gold standard.” — [Neophytou C et al. 2026](https://doi.org/10.3390/dj14010049), Dent J (Basel); cited 5.
- “The inconclusive and heterogeneous nature of the findings suggests that surface alterations should be considered alongside other factors, rather than as a stand-alone determinant, when selecting implant surface decontamination methods. Clinical trials are suggested to assess the impact of these alterations on clinical outcomes, such as bacterial growth and biological complications.” — [Valeriani L et al. 2026](https://doi.org/10.1111/clr.70077), Clin Oral Implants Res; cited 3.
- “Diode laser along with the nonsurgical management of peri-implantitis demonstrated no advantage compared to non-surgical treatment alone. Long term researches with considerable sample size will only enable us to appropriately assess this treatment modality.” — [Amit Kumar et al. 2026](https://doi.org/10.18231/j.ajohas.32321.1791449240), Asian Journal of Oral Health and Allied Sciences; cited 0.
- “Despite some positive findings, overall success rates for nonsurgical methods remain variable, highlighting the need for standardized treatment protocols and further research to individualize treatment.” — [Giovanni Battista Menchini-Fabris et al. 2026](https://doi.org/10.1016/j.jdip.2026.100004), Journal of Dental Implants and Prosthodontics; cited 0.
- “PDT exerted the most stable short-term efficacy for peri-implantitis. DL and Er:YAG had limited valid benefits. Due to insufficient long-term data, the sustained effects of these treatments and their roles in preventing lesion recurrence and maintaining implant survival are still undetermined.” — [Zhe Wang et al. 2026](https://doi.org/10.1097/md.0000000000051256), Medicine; cited 0.
- “High heterogeneity, diagnostic variability, and the low number of included studies increase the need of well-designed RCTs on the topic. Despite no conclusive evidence could be found, adjunctive aPDT showed a promising trend to improve MD results.” — [Nastri L et al. 2025](https://doi.org/10.3390/dj13120567), Dent J (Basel); cited 4.
- “This approach shows promise in reducing inflammation and promoting healing. Nonetheless, further high-quality research is necessary to confirm long-term benefits and establish clear clinical guidelines for its use.” — [Narjiss Akerzoul et al. 2025](https://doi.org/10.2174/0118742106400224250724113341), The Open Dentistry Journal; cited 3.
- “Both PDT and laser therapy are effective in reducing the microbial load. Additionally, laser causes the least surface alterations, with some studies reporting minor improvements in implant surface properties.” — [Maedeh Masoumzadeh et al. 2025](https://doi.org/10.18502/fid.v22i49.20330), Frontiers in Dentistry; cited 0.

32 further systematic review entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Guideline and consensus mentions

Neither of the two consensus reports in the index names this method in its abstract.


## Clinical studies and case reports

34 non-randomised clinical studies and 18 case reports or series.

- “Er, Cr: YSGG laser therapy in the decontamination procedure of previously contaminated implants in peri-implantitis therapy is successful in preserving the implant surface integrity in diverse peri-implantitis defects without major surface roughness alterations; it shows favorable biocompatibility with an appropriate osteogenic response in the four studied groups.” — [Hashim A et al. 2026](https://doi.org/10.1186/s12903-026-09278-3), BMC Oral Health; cited 1.
- “The combined use of mechanical debridement and a diode laser in the treatment of peri-implantitis is more effective at reducing clinical signs of inflammation than either method used alone. However, the lack of correlation between S100A8 levels and clinical improvement suggests that this biomarker may not be sensitive in short-term follow-up of treatment.” — [Akif Nalbant et al. 2026](https://doi.org/10.1007/s10103-026-04925-1), Lasers in Medical Science; cited 0.
- “The adjunctive use of the Er,Cr:YSGG laser significantly enhanced clinical outcomes and reduced inflammatory markers in peri-implantitis treatment. This approach holds promise as an effective adjunctive therapy in clinical practice.” — [Arvina Rajasekar et al. 2026](https://doi.org/10.32782/2226-2008-2026-2-4), ; cited 0.
- “The 970 nm diode laser at 1 W provides effective bactericidal action with minimal implant surface damage and can be recommended for clinical use in peri-implantitis treatment. The Nd:YAG laser at equivalent parameters is not recommended due to significant structural surface damage.” — [Ekaterina Yu. Diachkova et al. 2026](https://doi.org/10.65324/dtp007), Dentistry Theory and Practice; cited 0.
- “Purpose This pilot randomized controlled clinical trial evaluated the potential clinical benefits of adjunctive erbium-doped yttrium aluminum garnet (Er:YAG) laser therapy combined with mechanical and chemical implant surface decontamination. Specifically, it assessed 1-year clinical and radiographic outcomes after regenerative treatment for peri-implantitis with infrabony defects.” — [Hae-Won Park et al. 2026](https://doi.org/10.5051/jpis.2600540027), Journal of Periodontal & Implant Science; cited 0.
- “Er:YAG laser therapy appears to be effective in reducing probing depth and improving clinical parameters in the management of peri-implantitis, particularly when used as an adjunct to surgical regenerative therapy. Further studies with larger sample sizes and standardized protocols are necessary to confirm its efficacy for oral bacterial decontamination.” — [Salma Adnane et al. 2026](https://doi.org/10.5281/zenodo.21870265), Zenodo (CERN European Organization for Nuclear Research); cited 0.

28 further clinical study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Laboratory and animal findings

102 in vitro / ex vivo and 11 animal studies. Laboratory results describe discs, specimens or removed implants under test conditions and are not clinical outcomes.

- “To determine the changes induced by the laser, the following techniques were used: X-ray diffraction (XRD), Rietveld refinement method, scanning electron microscopy (SEM) with EDS (Energy-dispersive X-ray Spectroscopy), and thermography. The results show that the proposed Ti6Al4V and Ti6Al7Nb scaffolds can be exposed to an Er3+:YAG laser without damage when the power is limited to 0.5 W.” — [Sobierajska P et al. 2026](https://doi.org/10.3390/ma19040775), Materials (Basel); cited 2.
- “Ti ions and particles were found after instrumentation using SS curettes, Ti curettes, and CV ultrasonic inserts, which may affect the disease etiology and outcomes of peri-implantitis therapy more prominently compared to irradiation methods such as CS ultrasonic inserts, CO2 lasers, or ECY lasers.” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375), Int J Oral Maxillofac Implants; cited 1.
- “Er:YAG best preserved SLA microtopography but exhibited a lower debridement efficacy (3.27 ± 0.83) than mechanical methods. No method resulted in a pristine surface.” — [Yurdakul B et al. 2026](https://doi.org/10.3390/nano16120703), Nanomaterials (Basel); cited 1.
- “All active protocols reduced viable Staphylococcus aureus counts compared with untreated implants. Within the limitations of this single-species in vitro model, Er,Cr:YSGG laser irradiation achieved the greatest reduction, whereas GalvoSurge and CHX resulted in moderate and comparable decreases.” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294), Cureus; cited 0.
- “Laser treatment did not result in significant changes in implant surface roughness, suggesting its safety for use in surface decontamination without compromising implant integrity. This technology may represent a safer, more effective approach to implant surface decontamination than traditional methods.” — [Thuy Vo et al. 2026](https://doi.org/10.3934/bioeng.2026013), AIMS bioengineering; cited 0.
- “Laser plus ICG-loaded CNPs and CHX had comparably the highest decontamination efficacy. This study demonstrated that aPDT with ICG-loaded CNPs significantly reduced the A. actinomycetemcomitans colony count on dental implants, showing comparable efficacy to CHX.” — [Sayar F et al. 2025](https://doi.org/10.1038/s41598-025-15871-3), Sci Rep; cited 9.

96 further in vitro entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).

- “The results suggest that PDT and OFD have significant benefits in peri-implantitis treatment by reducing bacterial count. The presence of bacterial complex with different response to therapeutic modality suggests the use of combined decontamination methods for peri-implantitis treatment.” — [Madi M et al. 2018](https://doi.org/10.1155/2018/7570105), Biomed Res Int; cited 28.
- “Within the limits of the study, the combination of mechanical and chemical treatment proved to be the most effective treatment for disinfection of the anodized implant surface.” — [Htet M et al. 2016](https://doi.org/10.1902/jop.2016.150615), J Periodontol; cited 56.
- “Based on the results, no thermal damage was observed during implant surface decontamination by Er:YAG laser with and without refrigeration. Thus, Er:YAG laser irradiation can be a safe method for treatment of periimplantitis.” — [Monzavi A et al. 2014](https://pubmed.ncbi.nlm.nih.gov/24910697/), J Dent (Tehran).
- “Group aPDT showed more favorable results in parameter area of reactive tissue than the other methods after day 7, but over longer time periods all methods produced outcomes equivalent to sterile implants.” — [Salmeron S et al. 2013](https://doi.org/10.1902/jop.2012.120166), J Periodontol; cited 130.

7 further animal study entries of this chapter are in the table below and in [all entries](https://www.nitibrush.com/articles/literature-index/all-entries/).


## Parameters as stated in the abstracts

- “These alloys, commonly used in implantology, here in the form of Ti block scaffolds, have been exposed to an Er3+:YAG laser under various parameters (energy range of 50-320 mJ, exposure times of 20 or 30 s), and their effects have been further observed.” — [Sobierajska P et al. 2026](https://doi.org/10.3390/ma19040775) (in vitro).
- “For the laser groups, a CO2 laser (no contact, defocused beam, continuous wave, 2-W power) and an ECY laser tip were used (in contact with the implant; power of 2 W; 75 Hz; 40% water: 2% air).” — [Romanos GE et al. 2026](https://doi.org/10.11607/jomi.11375) (in vitro).
- “Implants were randomly assigned to four groups (n = 12/group): untreated control, CHX immersion for 60 s, GalvoSurge electrolytic cleaning for 120 s, or Er,Cr:YSGG laser treatment (2780 nm; 2.5 W; 30 Hz; 70% water; 60% air; 30 s).” — [Chedid C et al. 2026](https://doi.org/10.7759/cureus.113294) (in vitro).
- “An in vitro experimental study was conducted using scanning electron microscopy (SEM) of dental implant surfaces (Straumann, Astra Tech, Osstem, Alpha Bio) following exposure to a diode laser «LSP-IRE-Polyus» (970 nm) and a Nd:YAG laser at power settings of 1 W and 2 W.” — [Ekaterina Yu. Diachkova et al. 2026](https://doi.org/10.65324/dtp007) (clinical study).
- “The control group received mechanical debridement with a sham laser, while the test group received mechanical debridement followed by aPDT (Toluidine or Methylene Blue photosensitizer incubated for 1–3 minutes and irradiated with a 660/680 nm diode laser for 60–120 seconds).” — [Pallavi Goswami 2026](https://doi.org/10.5281/zenodo.23053610) (RCT).
- “The 2.5 W settings proved most effective in decontamination, although none of the laser settings completely eradicated the bacteria.” — [Thuy Vo et al. 2026](https://doi.org/10.3934/bioeng.2026013) (in vitro).

One sentence per paper, taken from the abstract where it names a speed, power, time, pressure, concentration or distance. Abstracts rarely carry the full protocol; the Methods section of each paper does.


## Products and manufacturers named

Names exactly as the authors wrote them in the abstract or, for open-access papers, in the Methods section. A name appears here because a paper used or discussed the product; it is not an endorsement, and the absence of a name means only that the paper did not state one.

- **Waterlase** — 6 entries
- **Air-Flow** — 6 entries
- **LightWalker** — 3 entries
- **Piezon** — 3 entries
- **GalvoSurge** — 2 entries
- **Cavitron** — 2 entries
- **TiBrush** — 2 entries
- **Perisolv** — 2 entries
- **Perio-Flow** — 1 entry
- **Ti-Brush** — 1 entry
- **i-Brush** — 1 entry
- **Vector** — 1 entry

Manufacturers: Straumann (16), Biolase (11), EMS (7), Fotona (7), Geistlich (6), Dentsply Sirona (5), Hu-Friedy (5), Nobel Biocare (4), Dentsply (4), Sirona (4), Astra Tech (3), Zimmer Biomet (3), Zimmer (3), Dentium (3), Osstem (2), KaVo (2), BioHorizons (2), Camlog (2), Acteon (1), NSK (1).


### Availability of named products, as far as public company information shows

Some products named in the papers are no longer offered by their original maker. The notes below record what public company information showed on the date given; they say nothing about the product or the studies performed with it, which remain studies of that device.

- **TiBrush (Straumann)** — The product name remains on Straumann's website; the Straumann Switzerland online shop describes the Labrida BioClean brush as replacing the Straumann TiBrush. An end of production or sale was not confirmed for every country. The clinical trials performed with the TiBrush remain studies of that device and are listed as such. Checked 2026-11-28; source: Straumann Switzerland online shop, Labrida BioClean product page.


## Chemical agents used alongside

Agents named in the same papers (20 different): chlorhexidine (47), saline (41), photosensitizer dye (28), hydrogen peroxide (22), antibiotics (systemic) (18), amoxicillin (15), sterile water (13), citric acid (10), sodium hypochlorite (7), metronidazole (6), tetracycline (6), minocycline (5), doxycycline (4), EDTA (3), povidone-iodine (3), ozone (2), phosphoric acid / etching gel (2), Perisolv (2), chloramine (1), enamel matrix derivative (1). Chapter 13 collects the chemical literature.


## Limitations of this chapter

- The entries are the publications a fixed PubMed search and an OpenAlex supplement return; relevant papers can be missing and a few retrieved ones may be off-topic. The search string is on the [how this reader is made](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) page.
- Study type, method, product, manufacturer and agent are assigned automatically from the title, abstract and — for open-access papers — the Methods section. A method listed for a paper may be a comparator, not the paper's subject.
- Quotations are the authors' conclusions about their whole protocol or comparison; they are not statements about this method in isolation, and this reader does not rank, grade or compare methods or products.
- Results obtained with one instrument are not transferred to another instrument of the same class, including those of different manufacturers.


## Entries in this chapter (283)

The 283 entries of this chapter are too many for this page to stay readable in one request; they are listed in the [table of all entries, filtered on this method](https://www.nitibrush.com/articles/literature-index/all-entries/#method=laser), and in the CSV/JSON data.


## Related chapters

- [6. Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/)
- [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- [9. Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/)
- [13. Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/)
- [14. Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/)
- [17. All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [4. Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/)
- Next: [6. Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/)
