# 2. How this reader is made — search, sources, classification, limits

The PubMed search string, the OpenAlex supplement, the automatic classification of study type, method, product, manufacturer and chemical agent, the quoted-conclusion rule, the exclusions, the refresh cadence and the limits of the implant surface decontamination reader (819 entries).

URL: https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/ · Reader Rev. 0 · 2026-11-28 · HTML and Markdown editions are generated from the same records · updated 2026-11-28

Part of *Implant Surface Decontamination in Peri-implantitis: an evidence-based reader* (https://www.nitibrush.com/articles/literature-index/). Chapters: 1. [Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/) · 2. [How this reader is made — search, sources, classification, limits](https://www.nitibrush.com/articles/literature-index/how-this-reader-is-made/) · 3. [Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/) · 4. [Air-polishing and air-abrasive devices](https://www.nitibrush.com/articles/literature-index/air-polishing/) · 5. [Lasers](https://www.nitibrush.com/articles/literature-index/laser/) · 6. [Antimicrobial photodynamic therapy](https://www.nitibrush.com/articles/literature-index/photodynamic-therapy/) · 7. [Implantoplasty](https://www.nitibrush.com/articles/literature-index/implantoplasty/) · 8. [Ultrasonic, sonic and piezoelectric instruments](https://www.nitibrush.com/articles/literature-index/ultrasonic-instruments/) · 9. [Curettes and hand instruments](https://www.nitibrush.com/articles/literature-index/curettes-hand-instruments/) · 10. [Electrolytic cleaning](https://www.nitibrush.com/articles/literature-index/electrolytic-cleaning/) · 11. [Cold atmospheric plasma](https://www.nitibrush.com/articles/literature-index/cold-plasma/) · 12. [Rubber cups and polishing paste](https://www.nitibrush.com/articles/literature-index/rubber-cup-polishing/) · 13. [Chemical and antiseptic agents](https://www.nitibrush.com/articles/literature-index/chemical-agents/) · 14. [Synthesis — what the systematic reviews and consensus reports conclude](https://www.nitibrush.com/articles/literature-index/synthesis/) · 15. [A note from the manufacturer — where the NiTi Brush stands in this literature](https://www.nitibrush.com/articles/literature-index/manufacturer/) · 16. [Glossary](https://www.nitibrush.com/articles/literature-index/glossary/) · 17. [All entries — the searchable table](https://www.nitibrush.com/articles/literature-index/all-entries/)

Where do the entries come from, how is each one classified, and what can go wrong?


## Sources and search

1. PubMed (NCBI E-utilities), all records returned by this search, 2000 to the present: `(("peri-implantitis"[tiab] OR periimplantitis[tiab] OR "peri-implant"[tiab]) AND (decontamination[tiab] OR debridement[tiab] OR detoxification[tiab] OR implantoplasty[tiab] OR "air polishing"[tiab] OR "air-polishing"[tiab] OR "air abrasive"[tiab] OR laser[tiab] OR brush[tiab] OR brushes[tiab] OR "surface treatment"[tiab] OR electrolytic[tiab]) AND ("implant surface"[tiab] OR "implant surfaces"[tiab] OR titanium[tiab]) AND 2000:2026[dp]) OR (("titanium brush"[tiab] OR "titanium brushes"[tiab] OR "NiTi brush"[tiab] OR "Ti-brush"[tiab] OR "rotary titanium brush"[tiab] OR "rotating titanium brush"[tiab]) AND (implant*[tiab] OR peri-implant*[tiab]) AND 2000:2026[dp])`
2. OpenAlex, twelve title searches on the same terms, kept only when the title mentions implants, the implant surface or titanium brushes (282 entries not indexed in PubMed); OpenAlex also supplies the citation counts and the open-access flag for every entry.
3. Open-access full text (NCBI PMC), Methods section only, read for 181 entries to pick up product, company and agent names that abstracts omit; marked "(full text)" in the table of all entries.
4. Topic screen: a record is kept only when its title or abstract describes cleaning, decontaminating, debriding or detoxifying an implant surface and at least one method of the dictionary is found. Records about implant manufacturing surfaces, ion release, osseointegration or prevalence are dropped by this screen.


## Classification

- Study type: from the PubMed publication type first (Randomized Controlled Trial, Systematic Review, Meta-Analysis, Practice Guideline, Consensus Development Conference, Review, Case Reports), then from the abstract wording (randomisation and patients; discs, specimens, biofilm models; animal species; patients or cohorts). Definitions are in [chapter 1](https://www.nitibrush.com/articles/literature-index/introduction/).
- Method: a fixed word list of eleven classes (titanium / NiTi brush, air-polishing, laser, photodynamic therapy, implantoplasty, ultrasonic / sonic / piezo, curettes / hand instruments, electrolytic cleaning, cold plasma, rubber cup / paste, chemical / antiseptic agents) matched against title and abstract.
- Product and manufacturer: a fixed list of decontamination products and of companies, reproduced exactly as the paper writes them; a name is shown only when the paper names it.
- Chemical agent: a fixed list of agents (saline, chlorhexidine, hydrogen peroxide, citric acid, tetracycline, doxycycline, minocycline, metronidazole, amoxicillin, EDTA, phosphoric acid, sodium hypochlorite, hypochlorous acid, povidone-iodine, ozone, photosensitiser dyes, chloramine, essential oils, sterile water, enamel matrix derivative, systemic antibiotics).
- Takeaway: the CONCLUSION section of a structured abstract, or the sentences after "In conclusion" / "Within the limitations of this study", or the last two sentences of an unstructured abstract — quoted without change and cut at 420 characters at a sentence end.
- Parameters: one sentence per paper from the abstract when it states a number with a unit (rpm, W, Hz, J/cm², bar, µm, mm, %, mg/mL, s, min) in connection with the chapter's method.


## What is not done

- No ranking, grading, weighting or recommendation. No pooled statistics. No risk-of-bias assessment.
- No comparison between products or manufacturers; results obtained with one instrument are not transferred to another instrument of the same class.
- No paraphrase of results: the quoted conclusion is the paper's own sentence, and the reader's own text describes the methods only.
- Nothing is written by hand into an entry. A wrongly retrieved paper is removed by listing its PubMed identifier in an exclusion file, never by editing its row.


## Refresh and corrections

The search, the supplement and the full-text pass are re-run every two to three weeks at first and monthly thereafter; the whole reader, including every count and quotation, is regenerated from the records each time. Last refresh: 2026-11-28. Corrections — a misclassified study type, a missed product name, an off-topic record — can be sent to info@nitibrush.com with the PMID or DOI; they are applied through the classification rules or the exclusion list, so that the next refresh keeps them.


## Limits

- Coverage depends on the search string: a paper that describes decontamination without one of the search terms in its title or abstract is not retrieved.
- Automatic classification misreads some abstracts; the "Not classified from the abstract" group holds the entries whose record gave no usable publication type or wording.
- A method appears for a paper when the abstract mentions it, which includes comparators and background mentions.
- Citation counts are OpenAlex counts at the time of the refresh and depend on OpenAlex coverage.
- Conclusion sentences are quoted for identification and remain the copyright of their authors and publishers; this reader hosts no paper and links only to DOI landing pages or PubMed.


## Version history of the reader

The reader has its own version number, separate from the revision of the [Published studies](https://www.nitibrush.com/articles/#versions) list: Rev. 0 is the first published edition and each released refresh of the records adds one. A refresh is recorded automatically, with the number of entries added and removed, as an entry in preparation until the update is complete and approved.


### Rev. 0 · 2026-11-28 · 819 entries, 36 name the NiTi Brush · Published studies Rev. 3

- First published edition of the reader: overview, introduction, methods chapter, 11 method chapters with sourced descriptions (every sentence footnoted to an entry), synthesis of all systematic reviews and consensus reports, manufacturer note, glossary, searchable table; each chapter also as Markdown.
- Sources: PubMed topic search, OpenAlex supplement, and the publications of the Published studies list fetched by DOI — 816 entries after merging records that both sources held (same DOI); open-access full text read for 181; all 36 publications of the Published studies list are entries.
- Hand-checked: the 50 most-cited entries (14 corrections of study type, conclusion sentence or method tags); Aoki 2015 reclassified as a review.
- Supersedes the single-table working versions of 28 November 2026 (511 and 793 entries), which were never released.
- Chapter 3: published clinical evidence by named brush (table + reading notes, 6 products); three papers added as a hand-listed supplement (Hwang 2023, Rakašević 2023, Ghaffar 2024); I.C.T. / De Ore wording counted as the NiTi Brush; availability notes for TiBrush and PeriBrush; overview FAQ on published evidence by brush; chapter 15 company statement on the evidence as a whole. (added to Rev. 0 on 2026-11-28 by the CEO's decision; no new number)

Reader Rev. 0 · 2026-11-28 · 819 entries, 2000–2026. Sources: PubMed (bibliographic data, publication type, abstract) and OpenAlex (282 entries not indexed in PubMed; citation counts); open-access full text read for product, company and agent names in 181 entries. Data: [JSON](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.json) / [CSV](https://www.nitibrush.com/assets/data/implant-surface-decontamination-literature.csv) (CC BY 4.0). Updated 2026-11-28.

> This reader is compiled and published by HANS KOREA CO.,Ltd., the manufacturer of the NiTi Brush, one of the instruments that appear in it. The method chapters report every instrument as its authors did and make no comparison; what the company states about its own instrument is confined to [chapter 15](https://www.nitibrush.com/articles/literature-index/manufacturer/). Entries, counts and quotations are generated from the PubMed and OpenAlex records on each refresh (last: 2026-11-28).

- Previous: [1. Introduction — the problem, the scope and how to read this reader](https://www.nitibrush.com/articles/literature-index/introduction/)
- Next: [3. Titanium and nickel-titanium brushes](https://www.nitibrush.com/articles/literature-index/titanium-brush/)
